Sales : +91-777 804 8217
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 20-05-2026 | Corrigendum No-3 | Date | 04-06-2026 |
| 2 | 07-05-2026 | Corrigendum No-1 | Financial Bid | 28-05-2026 |
| 3 | 07-05-2026 | Corrigendum No-1 | Financial Bid | 04-06-2026 |
| Sl. No. | Item Description |
| 1 | Surface preparation by dressing (cut & fill) and undesired top soil removed including removal of shurbs & vegetation if any, and maximum depth not to exceed 15 cm deep and disposing them away from the site up to 500 m lead (all kinds of soil) all complete as per direction of Engineer-in -charge. |
| 2 | Felling trees (soft wood) of the girth ranging upto 2.4 m (measured at a height of 1m above ground level) including labour for cutting of trunks and branches, excavation and removing the roots and stacking of wooden logs and other serviceable material and disposal of unserviceable material lead upto 500 m as per direction of Engineer-in -charge. |
| 3 | Beyond 30 cm girth upto and including 60 cm girth- Coconut tree |
| 4 | Beyond 60 cm girth upto and including 120 cm girth - Rain tree |
| 5 | Beyond 120 cm girth upto and including 240 cm girth - Rain tree |
| 6 | Demolishing brick work / block work / stone rubble masonry / concrete work manually or by mechanical means including disposal of material within 500 metres lead as per direction of Engineer-in -charge. |
| 7 | Demolishing R.C.C. work manually / by mechanical means including stacking of steel bars and disposal of unserviceable material within 500 metres lead as per direction of Engineer-in-charge. |
| 8 | Relocating the existing fencing to new location after dismantling and using the availabe dismantled departmental materials of trafford sheet, ISA 75x75x6mm verticals & ISA 50x50x6mm horiozntals. Verticals shall be fixed in ground using concrete of PCC 1:2:4 mix to the required size and rate include labour for dismantling, cutting, drilling holes, welding, fixing of fencing, hire for tools, other incidentals etc. complete as per direction of Engineer-in -charge. (Excluding PCC which will be measured separately). |
| 9 | Providing and fixing temporary fencing the site boundary using verticals of MS tubular section RHS 80x40x3mm at 2m centre to centre and horizontls 4 Nos using RHS 25x25x3 mm and covering with 0.30mm thick coloured Galvalume trafford sheet to a height of 3m and removal of the same after the completion of work. The vertical and strut members shall be encased in PCC (1:2:4) of size 0.25x0.25x0.30m, PCC (1:4:8) shall be provided at the base.The encasement shall be backfill and compacted. The Galvalume sheets shall be given 0.15m overlap at longitudinal joints. All structural steel members shall be mechanically cleaned with power brushing before using and the members shall be painted with two coats of synthetic enamel paint over two coats of zinc chromite primer. The rate shall include cost of all materials, welding, cost of painting the structural members, labour, tools and plants and all other incidentals etc. complete. |
| 10 | Boring, providing, and installing cast-in-situ reinforced cement concrete piles of specified diameter and average depth 55 m to 65 m, to carry a safe working load not less than specified as per approved drawing, using tractor-mounted rotary rig with Direct Mud Circulation (DMC) method, with minimum cement content of 400 kg/m³ of M30 grade concrete as per approved mix design. The rate is inclusive of the length of the pile to be embedded in the pile cap, boring through all strata including boulders/ soft rock using bentonite slurry for bore stabilization, removing the bored muck from site, temporary casing of minimum length 2m to 3m for setting out and removal of same, costs of cement etc. complete but excluding the cost of steel reinforcement. The rotary rig is to be replaced with percussion chisel, using tripod and mechanical winch machine, for clearing and flushing, including removal of excavated earth with all its lifts and leads and ensuring proper cleaning of the bore hole and concreting of the pile up to the required level. (Length of pile for payment shall be measured up to bottom of pile cap). |
| 11 | Pile - 50 cm dia |
| 12 | Pile - 60 cm dia |
| 13 | Pile -70 cm dia |
| 14 | Pile - 80 cm dia |
| 15 | Pile - 90 cm dia |
| 16 | Conducting in-situ Standard Penetration Test at the pile terminating point inside the pile bore hole to ascertain the N value, all complete and as directed by the Engineer-in-Charge. Rate is inclusive of hire charges of tools and plants, all labour, other incidentals etc. complete. |
| 17 | Conducting routine static load test upto 1.5 times the design load as directed and preparing reports there-on providing all equipment load personnel including construction of loading platform for kentledge with required reaction load etc., including and removal on direction thereafter from site conforming to IS-2911 (part-4) 1985 and amendments thereof and relevant clauses of tender specifications. The charges for providing RCC Bored. Cast-in-situ test pile of required length is already covered in specification. The charges shall include removing loose concrete, preparing the pile cap top for load test etc., all complete and inclusive as per design, drawing and as directed by Engineer-in -charge |
| 18 | Pile - 50 cm dia (82 MT capacity) |
| 19 | Pile - 60 cm dia (117 MT capacity) |
| 20 | Pile - 70 cm dia (160 MT capacity) |
| 21 | Pile - 80 cm dia (208 MT capacity) |
| 22 | Pile - 90 cm dia (236 MT capacity) |
| 23 | Integrity testing of pile using Low Strain / Sonic Integrity Test / Sonic Echo Test method in accordance with IS 14893 including surface preparation of pile top by removing soil, mud, dust & chipping lean concrete lumps etc. and use of computerised equipment and high skill trained personal for conducting the test & submission of results, all complete as per direction of Engineer-in-charge. |
| 24 | Chipping, cutting and removing excess length of RCC pile to line and level carefully without damaging the remaining portion, exposing and cleaning the reinforcement with wire brush for embedding in concrete as per drawing and gas cutting or sawing the excess reinforcement and removal of debris within a lead of 1km etc complete and as directed by Engineer-in-Charge. |
| 25 | Earthwork excavation in all classes of soils lift upto 1.50 m, except hard rock requiring blasting and breaking clods, watering, ramming and sectioning soil banks etc complete including loading and unloading, disposal of surplus earth within a lead of 500m. The rate quoted shall also including cost for shoring and structing , bailing out water etc. without disturbing the existing piles while excavating as directed by the Engineer-in-Charge. |
| 26 | Earthwork excavation in all classes of soils, except hard rock requiring blasting and breaking clods, watering, ramming and sectioning soil banks etc complete including loading and unloading, disposal of surplus earth within a lead of 500m. The rate quoted shall also including bailing out water etc. without disturbing the existing piles while excavating as directed by the Engineer-in-Charge. (area of sheet pile will be measured and paid seperately) |
| 27 | Lift 1.5m to 3m |
| 28 | Lift 3m to 4.5m |
| 29 | Lift 4.5m to 6m |
| 30 | Supplying and backfilling the pavement area with red earth including royalty in first layer not exceeding 200mm in depth and second layer not exceeding 100mm in depth, consolidating each deposited layer by ramming and watering including bailing out water, top most layer must be compacted with power roller of 8 tonnes capacity including all labour charges, cost and conveyance of all materials etc complete as per direction of Engineer-in-charge. (Measurement will be taken only for depth compacted layers.) |
| 31 | Supplying and filling the basement with quarry dust of compacted thick 200 mm, spraying water and compacting by ramming in layers of 50 mm thick and dressing up neatly including cost and conveyance of all materials, watering charges, labour charges etc complete. |
| 32 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering including bailing out water, all labour charges, cost and conveyance of plants and transporting earth from CSL permises within a lead of 500 m complete as per the direction of the Engineer-in-charge. |
| 33 | Providing sheet piling using profile steel sheets hammered to soil using excavator and jet water pumps interlocking with one by one for retaining the soil upto 5 mtr depth for the excavation, including supporting the sheets with steel channel / ISMB vertically and horizontally and securing using welding where ever required at 80cms interval or closer as per site conditions including additional ISMB at corner of each side and top of the sheet and welded for securing including boxing for additional safety if required and removal of all sections and driving our sheet piles after the completion of foundation / under ground construction including mobilization, installation charges, labour charges, loading, unloading, transportation, removing the sheet and demobilize after completion of work as per direction of Engineer-in-charge. (Only clear vertical area retaining the earth will be measured and considered for payment). |
| 34 | Disposal of surplus excavated earth, moorum/malba, building rubbish, similar unserviceable, dismantled or waste material by mechanical transport including loading, unloading and stacking upto 10Km lead as per direction of Engineer-in -charge. |
| 35 | Providing and laying coarse granular sub base using crusher run of having the composition of blue granite metals 40mm-50%, 20mm-15%, 12mm-10% ,6mm-10%, dust-15%, laid in layers not exceeding 300 mm thick and spreading to level, gradient and camber using motor grader, rolling at OMC using vibratory power roller of 8-10 tonne static weight to acheive not less than 98% proctor density complete as per specifications and directions of Engineer-in-charge. |
| 36 | Providing and laying in position plain cement concrete 1:4:8 (one cement, four quarry sand and eight 40mm nominal size hard granite broken stone) including centering, shuttering mixing, laying, compacting, all labour charges, cost and conveyance and delivery, handling, unloading, storing of all materials, cement etc. complete as directed by Engineer-in-Charge. |
| 37 | Providing and laying in position plain cement concrete 1:3:6 (one cement, three quarry sand and six 20 mm nominal size hard granite broken stone) including mixing, laying, compacting,shuttering & centering, all labour charges, cost and conveyance and delivery, handling, unloading, storing of all materials, cement etc. complete as directed by Engineer-in-Charge. |
| 38 | Providing and laying in position plain cement concrete 1:2:4 (one cement, two quarry sand and four 20mm nominal size hard granite broken stone) including centering, shuttering, mixing, laying, compacting, all labour charges, cost and conveyance and delivery, handling, unloading, storing of all materials, cement etc. complete as directed by Engineer-in-Charge. |
| 39 | Dry rubble packing and filling the voids of rubble packing with stone dust in foundations of sump tank and STP including all labour charges, cost, conveyance, delivery, handling, unloading, storage of all materials etc complete as per the direction of Engineer-in-Charge. |
| 40 | Providing and laying in position machine batched and machine mixed, design mix M30 grade cement concrete for Reinforced Cement Concrete work, using minimum cement content of 380 kg/m3, including cost of pumping of concrete to site of laying, compaction with needle vibrator, other required machineries and equipments, centering, shuttering, deshuttering and also providing polyfoam sheet (for slab shuttering), dewatering, finishing, curing, cost for precast concrete cover blocks admixtures in recommended proportions & approved mix design, delivery, handling, unloading, storing of all materials, labour, costs of cement etc. complate as per direction of Engineer-in-charge (excluding cost of reinforcement). |
| 41 | Pile cap |
| 42 | Grade Beam |
| 43 | Vertical wall of Lift pit, STP tanks, Sump tank, OHT, Cable trench, Drain etc |
| 44 | Base slab of Lift pit, STP tanks, Sump tank, OHT, Drain, cable trench, etc. |
| 45 | Floor slab |
| 46 | Belt over Basement and compound wall |
| 47 | Raft foundation for DG |
| 48 | Columns - Above floor II level upto floor V level |
| 49 | Columns - Above floor V level to floor IX level |
| 50 | Columns - Above floor IX level to above terrace level |
| 51 | Shear walls - Above floor II level upto floor V level |
| 52 | Shear walls - Above floor V level to floor IX level |
| 53 | Shear walls - Above floor IX level to above terrace level |
| 54 | Beam - Above plinth level upto floor V level |
| 55 | Beam - Above floor V level to floor IX level |
| 56 | Beam - Above floor IX level to above terrace level |
| 57 | Roof slab - Above plinth level upto floor V level |
| 58 | Roof slab - Above floor V level to floor IX level |
| 59 | Roof slab - Above floor IX level to above terrace level |
| 60 | Lintels - Above plinth level upto floor V level |
| 61 | Lintels - Above floor V level to floor IX level |
| 62 | Lintels - Above floor IX level to above terrace level |
| 63 | Staircase including landing slab - Above plinth level upto floor V level |
| 64 | Staircase including landing slab - Above floor V level to floor IX level |
| 65 | Staircase including landing slab - Above floor IX level to head room level |
| 66 | Counter slab - Above plinth level upto floor V level (Up to 100 mm thick) |
| 67 | Counter slab - Above floor V level to floor IX level (Up to 100 mm thick) |
| 68 | Counter slab - Above floor IX level to Terrace level (Up to 100 mm thick) |
| 69 | Drop slab - Above plinth level upto floor V level (Up to 100 mm thick) |
| 70 | Drop slab - Above floor V level to floor IX level (Up to 100 mm thick) |
| 71 | Drop slab - Above floor IX level to Terrace level (Up to 100 mm thick) |
| 72 | Precast cover slab -Above plinth level upto floor V level (above 100mm thick) |
| 73 | Precast cover slab - Above Terrace level (upto 100mm thick) |
| 74 | Providing and laying in position machine batched and machine mixed, design mix M40 grade cement concrete for Reinforced Cement Concrete work, using minimum cement content of 400 kg/m3, including cost of pumping of concrete to site of laying, compaction with needle vibrator, other required machineries and equipments, centering, shuttering, deshuttering, dewatering, finishing, curing, cost for precast concrete cover blocks admixtures in recommended proportions & approved mix design, delivery, handling, unloading, storing of all materials, labour, costs of cement etc. complete as per direction of Engineer-in-charge (excluding cost of reinforcement). |
| 75 | Column -Above plinth level upto floor 2 level |
| 76 | Shear wall -Above plinth level upto floor 2 level |
| 77 | Providing and laying Solid block masonry using precast cement concrete block of 20cm size, as per requirement having compressive strength not less than 4N/mm2 in cement mortar 1:6 (1 cement : 6 coarse sand) including hacking the concrete surface and applying cement grout, raking out joint, curing, scaffolding, including all labour charges, cost of all materials, conveyance, delivery, handling, unloading, storage of all materials, cement etc. complete as per direction of Engineer-in-charge. |
| 78 | Up to plinth level |
| 79 | From plinth level to floor V level |
| 80 | Above floor V level to floor IX level |
| 81 | Above floor IX level to terrace level |
| 82 | Providing and laying Solid block masonry using precast cement concrete block of 10cm size, in cement mortar 1:4 (1 cement : 4 coarse sand) having compressive strength not less than 4N/mm2 including hacking the concrete surface and applying cement grout, scoffolding raking out joint curing, including all labour charges, cost of all materials, conveyance, delivery, handling, unloading, storage of all materials, cement etc. complete as per direction of Engineer-in-charge. |
| 83 | Up to plinth level |
| 84 | Above plinth level up to floor V level |
| 85 | Above floor V level to floor IX level |
| 86 | Above floor IX level to above terrace level |
| 87 | Providing and laying Brick masonry with common burned modular brick of class designation 7.5 in cement mortar 1:6 (1 cement : 6 coarse sand) including applying cement grout, raking out joint, curing, scaffolding, including all labour charges, cost of all materials, conveyance, delivery, handling, unloading, storage of all materials, cement etc. complete as per direction of Engineer-in-charge. |
| 88 | Supplying and fixing Fiber mesh with nails on joints of columns, beams and brick walls before plastering including cost of drilling, scaffolding, cost and conveyance of all materials, labour, other incidentals etc. complete. Fixed mesh should be flush to joints to receive mortar as per direction of Engineer-in-charge. |
| 89 | Plastering the internal walls with Cement Mortar 1:4 (1 cement: 4 plastering sand), 12mm thk. in one coat floated hard and trowelled smooth finish including hacking the concrete surface, plastering in all chasing made in the walls for electrical and plumbing lines, finishing the top of skirting with cement screed, curing, scaffolding, cost and conveyance of all materials, labour, costs of cement, other incidentals etc. complete as per direction of Engineer-in-charge. |
| 90 | Plastering the external walls with Cement Mortar 1:4 (1 cement: 4 plastering sand), 15mm thk in one coat floated hard and trowelled smooth finish including hacking the concrete surface, plastering in all chasing made in the walls for electrical and plumbing lines, finishing the top of skirting with cement screed, curing, scaffolding, cost and conveyance of all materials, labour, costs of cement, other incidentals etc. complete as per direction of Engineer-in-charge. |
| 91 | All works above plinth level upto floor 3 level |
| 92 | All works above floor 3 level upto floor 6 level |
| 93 | All works above floor 6 level upto floor 9 level |
| 94 | All works above floor 9 level upto floor 12 level |
| 95 | All works above Terrace level |
| 96 | Plastering the ceiling, underside of RCC slabs, sides and soffits of beams, RCC walls, canopy, balcony slabs, staircases, sump tank, STP etc with Cement Mortar 1:3, 6mm thick in all lifts and leads including necessary scaffolding and removing the same after the work, chipping of RCC surfaces, curing, scaffolding, cost and conveyance of all materials, labour, costs of cement, other incidentals etc. complete, as per direction of Engineer-in-charge. |
| 97 | Roof top plastering with Cement Mortar 1:4, 12mm thick one coat floated hard and trowelled smooth including mixing, laying, compacting, curing, scaffolding, cost and conveyance of all materials, labour, cement, other incidentals etc. complete as per direction of Engineer-in-charge. (Plastering work shall be done after waterproofing the concrete surface) |
| 98 | Plaster drip course / groove/ band in plastered surface or moulding to RCC projections including necessry scaffolding, hacking concrete surface, curing, cost and conveyance of all materials and tools, labour, other incidentals etc. complete, including cost of cement as per direction of Engineer-in-charge. |
| 99 | Providing and fixing 12 mm thick laminated frameless toughened (6mm toughend glass + 1.5mm clear PVB + 6mm toughend glass) door shutter of approved brand and manufacture, including providing and fixing top & bottom pivot & double acting hydraulic floor spring type fixing arrangement and making necessary holes etc. for fixing required door fittings: (1) SS Door Handle H type of length 300 mm and 25 dia. (4 Nos.), (2) SS PT Standard lock with strike plate & EPC for patch fitting (3) SS Half dome door stopper - floor mounted. all complete as per direction of Engineer-in-charge |
| 100 | Supply and installing fixed glass partition of full height using 12mm thick toughened glass using SS glass patches of approved make at top and bottom. The glass to glass joints, glass to wall shall be filled with silicon sealant on both side. Rate shall include costs of all materials, conveyance, handling, loading and unloading, installation, providing cut out / holes on glass wherever required for the fittings, protecting the module and glass till handing over, all necessary hardware's wastage etc. complete and all as per the direction of Engineer incharge. |
| 101 | Providing and fixing in position partly glazed aluminium door using powder coated aluminium section of size not less than 101.6x44.45x1.6mm for door frames, shutter top and vertical styles of size not less than 50x44.5x2.0 mm, 100x44.45x2.0 mm or greater for shutter bottom including glazing clip with 8mm plain glass at top and ACP sheet of thickness not less than 4 mm at bottom, brass mortice latch 6 lever, Aluminium handle, tower bolt and all necessary fittings including cost and conveyance of all materials etc. complete as per drawing and direction of Engineer incharge. (Size of aluminium sections shall not be less than mentioned in the above specification) |
| 102 | Providing and fixing both side veneered flush door for internal doors of all flats with matching veneer wrapped engineered wood jamb (frame) of size 100x40 mm with one side 50mm architraves other side tackers, all with specialised lacquer polish. Door shall be of 32 mm thick with four side PVC lipping / lock hole boring (mortise lock) / hinge rebate cutting (4 Nos.) / extruded Sauerland core filling including cost of fixtures such as stainless steel butt hinges 4nos, oxidized MS tower bolt black finish (barrel type) 2 nos- 250x10mm at top and mid portion, 1No. 6 lever best quality mortise latch and lock with handle and necessary screws, nails, labour and other incidentals etc complete as per drawings and directions of Engineer in-charge. |
| 103 | Supply and installation of Steel Single Doors to main doors having single rebate architrave frame 100x78 of 12 mm sheet thick with puff infill with treshold, 46 mm shutter of 0.80 mm sheet thick with honey comb infill, fabricated using 120 GSM zinc coated steel, powder coated & sublimated to approved wood finish colour including all fixtures and fastners such as lever lock with handle, 4 Nos SS 304 hinges, 2 Nos SS tower bolts, 1 No. eye viewer and door stopper of approved make with necessary screws nails, labour and other incidentals etc complete as per approved drawings and design by Engineer in-charge. |
| 104 | Providing and fixing factory-made uPVC casement door of size 900 mm × 2010 mm fabricated from SCL 60 mm Casement Series multi-chambered, UV-resistant, lead-free white uPVC profiles consisting of 60 mm × 60 mm outer frame reinforced with 1.5 mm thick GI/Al section and 60 mm × 104 mm outward opening sash with 1.5 mm thick reinforcement, fitted with 6 mm thick clear toughened glass fixed using internal glazing bead and EPDM weather seal gaskets for airtightness and watertightness. The shutter shall be provided with double side handle with key (S1 type), standard lockable cylinder, and 3D adjustable heavy-duty hinges, all in matching white finish. All joints shall be fusion welded, smooth and finished with non-staining, neutral-cure silicone sealant at frame and masonry junctions for proper sealing. The complete unit shall have a smooth, factory-finished, UV-stabilized white surface, maintenance-free and corrosion-resistant, fixed to the wall using approved stainless steel anchor fasteners and sealed all around, all complete & as per direction of Engineer-in-Charge. |
| 105 | Providing and fixing PVC door frame (for all toilet doors) with shutter, door frame of size 50mm x 60mm having single rebate of 32mm x15mm. Door shutter shall be 30 mm thick PVC shutter of required colour and approved brand and manufacture including fixing of frames,mortice latch or fab locks, SS hinges-4Nos including cost and conveyance of all materials, all lead, lift and labour charges for erection etc.complete as per drawing and as directed by Engineer-in-Charge. |
| 106 | Providing and fixing FRP door frame with shutter, door frame of size 90mm x45mm having single rebate of 32mm x15mm. Door shutter shall be 30 mm thick Glass Fiber Reinforced Plastic (FRP) panelled shutter of required colour and approved brand and manufacture including fixing of frames, stainless steel cylindrical knob lock with pushbutton and coin release, Stainless steel hinges- 4Nos including cost and conveyance of all materials, all lead, lift and labour charges for erection etc. complete as per drawing and as directed by Engineer-in-Charge. |
| 107 | Providing and fixing powder coated aluminium sliding door to handicapped toilet (top hung rail) with 30mm thick FRP panel of required colour and approved brand and manufacture, including all necessary fittings such as foot closer-1No, handle -2Nos, tower bolt, aldrop -1No and lock etc complete as per directed by Engineer-in-Charge. |
| 108 | DUCT DOOR (FIRE RESISTANT): Supply & Installation of Fire Resistant steel Door 2 Hrs Rated without Panic bar with frame. Door frame shall made out of minimum 1 mm thick GI steel sheet, pressed to single rebate profile. Door shutters are made with minimum 1 mm thick GI steel sheet pressed formed to provide a 46mm thick fully flushed double skin panel. Joints and edges are filled with fire resistant grade ceramic wool and high temperature honey comb structure with reinforcement at top including locks and hinges etc complete as per direction of Engineer-in-Charge. |
| 109 | INTERNAL FIRE DUCT DOOR: Supply & Fixing of Internal Fire Duct door having the size of 1000 x 1700mm made of 2mm thick MS sheet, powder coated, double door 6mm glazed glass with water proof rubber beeding indoor type wall mounted lockable type. It shall be in Fire red colour. Cost shall include the cost of break glass box containing the key of the door, handles, locks, and hinges, all materials, labour, etc, all complete as per direction of Engineer-in-charge. |
| 110 | Supplying and fixing powder coated extruded aluminium 27 mm series 3 -track sliding window consisting of two sliding aluminium shutter on two track and one intermediate track fitted with stainless steel mosquitto net. sliding shutter glazed with 4mm anealed plain glass fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitered and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, sliding lock etc. complete as per architectural drawings and the directions of Engineer-in-charge. |
| 111 | Providing and fixing powder coated aluminium ventilators with fixed glass and provision for exhaust fan to all toilets with using extruded built up standard tubular sections/ appropriate Z sections and other sections of approved shade and make, fixing with dash fasteners of required dia and size. Aluminium sections shall be rust free, straight, mitered and jointed mechanically wherever required including Lovered profile,channels,stopper, C.P. brass / stainless steel screws, anodized aluminum casement stay etc. complete as per architectural drawings and the directions of Engineer-in-charge. |
| 112 | Providing and fixing 60 mm thick glazed fire resistant door shutters of 120 minutes fire rating conforming to IS:3614 (Part II) or EN1634-1:1999, tested and certified as per laboratory approved by Engineer-in-Charge, with suitable mounting on door frame of section 50 x 60 mm on horizontal side & 35 x 60 mm on vertical sides having built in rebate made out of 1.6 mm thick. GI sheet ( Zinc coating not less than 120gm/sqm). The shutters consisting of vertical styles, top rail & side rail 60mm x 60 mm wide and bottom rail of 110 mm x 60 mm made out of 1.6mm thick G.I. sheet (zinc coating not less than 120gm/sqm) duly filled mineral wool insulation having density minimum 96 kg/cum and fixing with necessary stainless steel ball bearing hinges of size 100x89x3mm of approved make. The frame shall be filled with mineral wool Insulation having density minimum 96Kg/cum. The frame will have a provision of G.I. anchor fastners 14 nos (5 each on vertical style & 4 on horizontal style of size M10 x 80) suitable for fixing in the opening along with factory made template for SS ball bearing hinges. Cost including providing and Fixing of fire rated Mortice lock with with handle, Hydraulic door closer, panic bar of desired finish as per EN 1 125 of and applying a coat of approved fire resistant primer or powder coating not less than 30 micron etc. all complete as per direction of Engineer-in-Charge |
| 113 | Supplying and laying Fully vitrified premium quality floor tiles of size 1200 X 600 mm in light colours and shades of approved make, set in 20mm thick C.M 1:4 plastering and adding necessary cement slurry to the back of the tiles for the proper binding of the tiles in lines and levels including epoxy grouting the joint with 3mm width, nosing the edges of the tile wherever required including cost / conveyance, delivery, handling, unloading, storing of all materials, lowering, hoisting, all labour for finishing to required shape and size, setting, fitting and fixing in position, straight cutting and waste disposal, disposal of packings, costs of cement other incidentals etc complete as per direction of Engineer-in-Charge for all floors except toilet, kitchen and balcony. (Take basic rate of Tile as Rs.650/m2) |
| 114 | Supplying and laying stain & scratch resistant vitrified floor tiles of size 600x600mm mat finish in light colours and shades, set in 20mm thick C.M 1:4 plastering and adding necessary cement slurry to the back of the tiles for the proper binding of the tiles in lines and levels and Grouting the joints of tiles having joints of 3mm width, using epoxy grout mix of 0.70 kg of organic coated filler of desired shade (0.10 kg of hardenerand 0.20 kg of resin per kg) including nosing the edges of the tile wherever required including labour charges, curing, cost and conveyance of all materials, cement etc complete as per the directions of Engineer-in-Charge (Take basic rate of tile as Rs. 560/m2). |
| 115 | Supplying, providing and fixing premium 1st quality Vitrified wall tiles of size 600x600mm (thickness to be specified by the manufacturer) and water absorption less than 0.08%, of make, colour and shade as approved by Engineer-in-Charge, over a cement-based, high polymer-modified, quick-set tile adhesive (water-based) in an average thickness of 6mm.Joints shall be maintained at 3mm width and grouted using an epoxy-based grout comprising 0.70 kg of organic-coated filler of approved shade (0.20 kg of resin and 0.10 kg of hardener). The work includes thorough surface preparation,cutting, laying, joint alignment, grouting, cleaning, curing and finishing to achieve a neat and uniform surface. The rate quoted shall include the cost and conveyance of all materials, cement, labour, tools, equipment, disposal of packings, finishing with coloured corner trim at corners & where ever necessary and all incidental charges required for completing the work in all respects complete as per direction of Engineer-in-charge. (Take basic rate of tile as Rs.560/m2) |
| 116 | Supplying, providing and laying premium 1st quality Vitrified anti skid floor tiles,of size 600x600mm (thickness to be specified by the manufacturer) and water absorption less than 0.08%, of make, colour and shade as approved by Engineer-in-Charge, over a cement mortar bed of 20mm thickness in the ratio 1:4 (1 cement: 4 coarse sand).Joints shall be maintained at 3mm width and grouted using an epoxy-based grout comprising 0.70 kg of organic-coated filler of approved shade (0.20 kg of resin and 0.10 kg of hardener). The work includes thorough surface preparation, cutting, laying, joint alignment, grouting, cleaning, curing and finishing to achieve a neat and uniform surface. The rate quoted shall include the cost and conveyance of all materials, cement, labour, tools, equipment, disposal of packings and all incidental charges required for completing the work in all respects for all toilets. (Basic rate (without tax) for tile- ₹ 600/m2) |
| 117 | Supplying and laying with 22 mm thick cement concrete tiles for ramp, porch and parking area set in 20mm thick C.M 1:4 thick plastering and adding necessary cement slurry to the back of the tiles for the proper binding of the tiles in lines and levels including cost, conveyance, delivery, handling, unloading, storing of all materials, lowering, hoisting, all labour for finishing to required shape and size, setting, fitting and fixing in position, straight cutting and waste, disposal of packings, pointing the tile joint with matching colour joint filler including curing, finishing acid washing, cement other incidentals etc as per the directions of Engineer-in-Charge. (Take basic rate of tile as Rs.550/m2 ) |
| 118 | Supplying and laying 80 mm thick factory made cement concrete interlocking paver block of M30 grade of approved size, design & shape, laid in required colour and pattern approved by Engineer-in-Charge including 50mm thick compacted bed of 6mm metal, filling the joints with fine sand including cost, conveyance, delivery, handling, unloading, storing of all materials, all labour for finishing to required shape and size, setting, fitting and fixing in position, straight cutting and remove waste, etc. all complete. (Take basic rate of tile as Rs.750/m2) |
| 119 | Providing and fixing 18mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut Granite slab over cement mortar 1:4 (1 cement : 4 coarse sand), for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture, joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. including charges for labour, conveyance, delivery, handling, unloading, storage of materials, cost of all materials, cement etc. complete at all levels as per direction of Engineer-in-charge. Provisions for PVC pipe holes/ gas line holes to be maid on slab without any extra cost. Only single-piece granite will be allowed for slab lengths upto 3 meters. Basic rate (without tax) for Granite- Rs.2500/m2. |
| 120 | Providing opening of required size & shape for wash basin/ kitchen sink in kitchen platform, vanity counter and similar location in marble/ Granite/ stone work, including cost of necessary holes for pillar taps, moulding, rubbing and polishing of cut edges etc. complete. |
| 121 | Supplying, providing and fixing on to stair case steps of premium Vitrified step tiles of size 300x1200mm (with grip and edge moulding) combinations of different colours as directed by the Engineer in charge over 20mm thick cement mortar base with cement mortar 1:4 (1cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc. The rate is inclusive of cost and conveyance of all materials, labour, curing, cement, other incidentals, etc complete (Take basic rate of vitrified step tile as Rs.950/m2) |
| 122 | Cement plaster floor finishing with 20 mm thick cement plaster 1:4 (1 cement : 4 sand) finished with floating coat of neat cement at all levels including cost and conveyance of all materials, cement, charges of providing joints in plastered surface at 60cm intervals, curing and labour charges etc as per the instructions of Engineer-in-Charge. |
| 123 | Tile work in skirting, risers of steps, 0.1m height using following tiles with cement based high polymer modified quick set tile addessive with an average thickness 6 mm at all levels and grouting the joints with epoxy grout 3mm thick to match with the tiles in line and level including cost and conveyance of all materials, labour charges, curing etc complete except cost of cement as per the directions of Engineer-in-charge. |
| 124 | Supplying and fixing lift wall cladding Stone tile (polished) work for wall lining over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and cement slurry @ 3.3 kg/sqm including pointing in white cement complete, including cement (Granite of approved colour and shade) |
| 125 | Providing and applying single coats of white cement based putty of average thickness 1mm of approved brand and manufacturer over the plastered wall surface to prepare the surface even and smooth including cost and conveyance of all materials, scaffolding charges and labour etc. complete. |
| 126 | Providing and applying one coat of water based cement primer for interiors of approved brand and manufacture including cost and conveyance, delivery, handling, unloading, storing of all materials and labour, waste, return of packings, necessary scaffoldings, protective cover, cleaning stains from floors, walls, glass panes etc. complete. |
| 127 | Providing and applying one coat of water based cement primer for exterior surface of approved brand and manufacture including cost and conveyance of all materials and labour, waste, return of packings, protective cover, cleaning stains from floors, walls, glass panes etc. complete for lift from ground floor to terrace floor including staging / rope access ( european standard ). |
| 128 | Painting on inner walls and ceiling two coats of premium acrylic emulsion paint of interior grade having VOC (Volatile Organic Compoud) content less than 50 grams/lit. of approved brand and colour including cost and conveyance, delivery, handling, unloading, storing of all materials and labour, waste, return of packings, necessary scaffoldings, protective cover, cleaning stains from floors, walls, glass panes etc. complete. |
| 129 | Painting on external walls two coats of weather shield coat paint of suitable colour of approved brand and colour including cost and conveyance of all materials and labour, other incidentals, waste, return of packings, protective cover, cleaning stains from floors, walls, glass panes etc. complete for lift from ground floor to terrace floor including staging / rope access ( european standard ). etc. complete for lift from ground floor to terrace floor including staging / rope access ( European standard ) |
| 130 | Painting with two coats of enamel paint of suitable colour of approved brand and colour on all steel works including cost and conveyance, conveyance, delivery, handling, unloading, storing of all materials and labour, waste, return of packings, necessary scaffoldings, protective cover, cleaning stains from floors, walls, glass panes etc. complete. |
| 131 | Finishing walls with premium textured exterior paint of required shade and colour on new work (Two coats applied @ 3.28 ltr/10 sqm) over the wall surface must be cleared from dust, mill scales and filling the cracks with crack filler etc. |
| 132 | Supply, fabrication and fixing M S grill for Windows, ventilators as per approved design drawing MS including all labour & hire charges for fabricating and cost of all materials and applying a coat of zinchromite primer etc complete as per the approval of Engineer-in-Charge. |
| 133 | Supply, fabrication and fixing M S gate as per approved design drawing including all labour & hire charges for fabricating and cost of all materials and applying a coat of zinchromite primer etc complete as per the approval of Engineer-in-Charge. |
| 134 | Supply, fabrication and fixing MS handrails to staircases, steel ladder with MS tube/box sections as per approved design drawings by welding etc. and similar works, including applying zinc chromate priming coat of approved steel primer, welding, grinding, buffing and making curvatures and closing the ends of pipes wherever required and fixing the same with necessary nuts and bolts of required size, fasteners etc complete as per the approval of Engineer-in-Charge. (Measurement will be taken in Kg.) |
| 135 | Supplying, fabricating and fixing SS handrails (304 Grade) to entrance lobby as per approved design drawings using pipes, hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required), closing the ends of pipes and fixing the same with necessary stainless steel nuts and bolts of required size, stainless steel dash fasteners etc. of required size and suitable arrangement as per approval of Engineer-in-charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.) |
| 136 | Supplying, fabricating and fixing chequered plates of 4 mm thick over angles of size 25x25x4mm, with two coats of synthetic enamel paint over one coat zinc chromate primer, in ducts including cost & conveyance, delivery, handling, unloading, storage of materials and all other necessary accessories, labour charges, etc. complete as per direction of Engineer-in-charge. |
| 137 | Supplying, providing and fixing SS fan clamp of SS round bar, bent to shape with hooked ends in RCC slabs or beams during laying of concrete, all as per standard design and drawing. The rate is inclusive of cost of material and labour for fabrication and fixing etc. complete as per direction of Engineer-in-charge. |
| 138 | Supply, fabrication and fixing M S grill for Cable trench cover as per approved design drawing using MS flat/square rod including all labour & hire charges for fabricating and cost of all materials and applying a coat of zinchromite primer etc. complete as per direction of Engineer-in-charge. |
| 139 | Supply, fabrication and tying in position various sizes of Fe 500D or more TMT reinforcement bars of following grades to size and shape for all R.C.C. items of work at all levels including straightening, cutting, cold bending, lapping, welding the reinforcement, hire charges of welding equipments, tools and plants, welding electrode, placing in position and binding with 22gauge G.I bending wire including cost of all materials, cost of binding wire, conveyance, and all labour charges etc complete as directed by Engineer-in-Charge. The rate is includive of wastage. No wastage will be payable by CSL. The scrap can be taken by the contractor. |
| 140 | Providing and fixing suspended GYPSUM board false ceiling, which includes providing and fixing of G.I perimeter channels of size 27mm, 0.5mm thk, having one flange of 20mm & another flange of 30mm along the perimeter of the ceiling fixed to brickwork/ partitions with help of raw plugs and screws. Suspending G.I Intermediate channel of size 45mm , 0.9mm thk having two flange of 15mm each suspended from the soffit with GI wire of 12mm to 38mm thk with GI cleat and expansion fasteners at 1200mm c/c. Ceiling section of 0.5mm thk having knurled wedge of 51.5mm and two flange of 26mm each with two leafs of 10.5mm each are fixed to intermediate channel with (Gypsteel Ultra) help of connecting clips and in direction perpendicular to the intermediate channel at 1220mm centre length and bolt it at two places by 7.5mm and 12.5mm , to get the rigid. 12.5mm thk tapered edge of GYPBOARD of approved make is screwed fixed to ceiling section with 25mm dry wall screws at 1200mm centers .screws fixing will be done mechanically either with screw driven or drilling machine. A Gap of 1.5mm to 2.5mm is provided all around, in between boards and then screws should be 15mm away from the edge of the boards are joined by jointing tape to give flushed finish. Cost should include cutouts for the lights and services as indicated in the drawing and as per instruction. Cost should include the Jointing compound, Putty & primer suitable for Gyp board and also finished with two coats of acrylic emulsion paint of approved make and shade, etc., complete |
| 141 | Providing & installing to true line and level commercial type Suspended PVC Modular Ceiling suspended using suitable support system at every 1200mm intervals. Grids width: 24 mm finished in approved shade. The main runners & cross Tees to have \\"stab\\" installation system made of corrosion protected galvanized steel or approved equivalent. Ceiling tiles are tegular edged Poly Vinyl Chloride ceiling tile of size 595 x 595 x 7 mm thk. GI sections for use as Main Runners are 24 x 38 x 0.33mm, Cross Tees are 24 x 25 x 0.33mm and Wall Angles are 24 x 24 x 0.4mm and GI supports (GI sections can be changed to higher sections having same or greater thickness to suit the site conditions). False Ceiling will be measured on horizontal Plane only. Horizontal Plane measurements are to be inclusive of vertical drops, edge mouldings, fascias etc. Rate quoted to include cost and conveyance of all materials, all cut outs required for light fixtures, labour cost, hire charges of equipments, consumables, scaffolding cost, other incidentals etc. complete. |
| 142 | Providing and fixing bulkhead with 12mm MR gypsum board for conceiling water supply line inside building, upto 30cm depth, with necessary GI metal sections supports, anchors, bolts. Rate is inclusive of cost for putty, painting and jointless surface inside the building etc. complete as per the direction of Engineer-in-Charge. |
| 143 | Supplying and fixing green garden net having 50% transperancy from top to bottom floor of the construction including costs of materials, labour, fixing charges etc. complete as per direction of Engineer-in-charge. |
| 144 | Supply, providing and fixing aluminium single wall ladder, with side C section 65mmx38mm, steps 25.4mm dia., nonslip corrugated tubing, permanent punching in machine, solid rubber shoes and caps at terrace floor. The ladder should be fixed to the wall using clamps and foot of ladder to be encased in concrete (115x88mm and depth 120mm). The rate of concrete will be paid separately. Rate shall be including all materials, labour, lead, fabrication charges, cost of all consumables, scaffoldings, etc. |
| 145 | Diluting & injecting chemical emulsion of IMIDA CHLOPRID (30.5% SC) for pre-constructional Anti-termite treatment to the entire basement floor, sides of plinth beam, columns, footings, expansion joints, external perimeter etc.at 0.5 Ltr/hole 60cm apart up to a depth of 45cm and 2cm diameter holes with suitable tool, spraying the chemical through the hole 3 times in an interval of 15 minutes, so as to ensure saturation of chemical emulsion thoroughly through to the soil beneath the total plinth area at the required level including all material and labour etc. complete. |
| 146 | Providing and laying at or near ground level factory made kerb stone of M-25 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement: 3 coarsesand), including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5mm), including making drainage opening wherever required complete etc. as per direction of Engineer-in-charge (length of finished kerb edging shall be measured for payment). (Precast C.C. kerb stone shall be approved by Engineer-in-charge). |
| 147 | Providing and fixing 20mm stainless steel 304 curtain rod having wall thickness of 1.20 mm with two SS brackets fixed with C.P brass screws and PVC sleeves as per direction of Engineer-in-Charge. |
| 148 | Providing & fixing wall mounted Aluminium Kitchen Cabinet using powder coated aluminium section of size not less than 38mm x 25mm x 1.5mm for outer frame, cabinet door shutter frame. HPL PVC sheet 3mm thickness used for the cabinet. Magnet catcher, 4\\" SS backscrew handle, auto closed hinges and other necessary fittings including cost and conveyance of all material, all lead, lift, and labour charges for erection etc. complete as per drawing and direction of Engineer-in-Charge. |
| 149 | Supply, erection and commissioning of community FRP Bio bin system (1m3-3 bins) with proper rain guard covers, rat guards on the sides, removable cross bars and detachable doors for removal of compost (Brackets and hinges in Stainless Steel) for processing bio degradable rejections as per the conditions of Kerala polution controll board. |
| 150 | Supplying and fixing SS engraving name plates of marking floor number, quarter number and coomon facilities of approved size and shape including cost of material, designing, engraving and fixing in position as per the direction of engineer in charge. |
| 151 | 6 inch x 4 inch for flat number |
| 152 | 18 inch x 4 inch for floor number |
| 153 | 20 inch x 7 inch for other boards |
| 154 | Providing and placing in position suitable PVC water stops 225 mm wide, 8-11 mm thick for construction of RCC tanks and fixed to the reinforcement with binding wire before pouring concrete etc. complete serrated with central bulb. Rate is inclusive of cost and conveyance of all material, labour charge for erection, cost of fixtures etc. complete as per the directio of Engineer-in-Charge. |
| 155 | Toilet Sunken Waterproofing |
| 156 | Bore Packing upto 4.5\\" dia: Preparing the inside surface of core by roughening using suitable file to get better adhesion prior to packing works. Cleaning the surface by wire brushing followed water jet to remove any laitance or loose flaky particles. Applying a coat of styrene- butadiene based polymer coating to enhance adhesion between the packing material and other surfaces. Packing the gap using non-shrink cement polymer based grout upto the surface of the bore whilst the polymer additive in tacky state. Rate is inclusive of cost and conveyance of all material, labour charge, cost of consumables etc. complete as per the direction of Engineer-in-Charge. |
| 157 | COATING : The floor surface to be fine chipped and all dust cleared and ensured free from dust. The surface wire brushed and fine cleaned and corners haunched with Polymer mortar (Adding polymer latex 10% by weight of cement to cement sand mortar in CM 1:4). A Bond coat of the same to be applied prior to placing of Polymer mortar. The surface to be coated with a Bond coat of polymer latex mixed with water and cement in the ratio 1:4:7. It is followed by coating of 2 component cementitious elastometric waterproofing coating @ 1.5kg/sqm per 2 coats. The surface air cured for 72 hours. The floor to be coated and raised on the wall 0’9’’ from finished floor level. Water ponding to be done again on the sunken/flat toilet RCC floor and checked for leakages after the waterproofing has been done including of cost and conveyance of all material, labour charge, cost of consumable etc. complete as per the direction of Engineer-in-Charge. |
| 158 | PROTECTIVE PLASTERING: The waterproof surface done with a protective plastering of 15mm thick in CM 1:3 with adding Waterproofing admixture of dosage 125ml/per bag of cement and finished the surface including of cost and conveyance of all material, labour charge for erection, cost of fixtures etc. complete as per the direction of Engineer-in-Charge. |
| 159 | Lift Pit Water Proofing |
| 160 | Providing pressure grouting on the RCC wall surface to be checked for voids / honeycombs and marked for pressure grouting. Also the cold joints (Construction joints) to be marked and pvc nozzles fixed every 1m c/c or as required as per site conditions with polymer mortar and pressure grouted with cement slurry @ 40 Psi or 2 kg/sqcm pressure admixer (Admixture 225 gms/per bag of cement) and finished. The holes filled with Polymer mortar mixed 10% by weight of cement (cement mortar 1:3) and finished. Rate is inclusive of cost and conveyance of all material, labour charge, cost of consumables etc. complete as per the direction of Engineer-in-Charge. |
| 161 | WATERPROOFING OF LIFT PIT COATING: The surface to be wire brushed and cleaned and cracks if any to be filled and corners to be haunched with polymer mortar. The surface is coated with one Bondcoat followed by 3 coats of cementitious flexible (2 component acrylic cementatious waterproof coating (@ 2KG/Sqm) with required time intervals between coats and finished. Corners to be kept 45 GSM Geotextile mesh sandwidched between layers. Rate is inclusive of cost and conveyance of all material, labour charge, cost of consumables etc. complete as per the direction of Engineer-in-Charge. |
| 162 | Providing protecting plastering of 20mm thick in CM 1:3 adding Waterproofing admixture, dosage as per manufacturers specification to be done over the coating and finished the surface including of cost and conveyance of all material, labour charge for erection, cost of fixtures etc. complete as per the direction of Engineer-in-Charge. |
| 163 | STP Tank Waterproofing |
| 164 | PRESSURE GROUTING : The RCC wall surface to be checked for voids / honeycombs and marked for pressure grouting. Also, the cold joints (Construction joints) to be marked and pvc nozzles fixed every 1m c/c or as required as per site conditions with polymer mortar and pressure grouted with cement slurry @ 40Psi or 2 kg/sq.cm pressure admixer (Admixture-225 gms/per bag of cement) and finished. The holes filled with Polymer mortar (mixed 10% by weight of cement in cement mortar 1:3) and finished the surface including of cost and conveyance of all material, labour charge, cost of consumables etc. complete as per the direction of Engineer-in-Charge. |
| 165 | WATERPROOFING OF STP TANK : The surface to be wire brushed and cleaned and cracks if any to be filled and corners to be haunched with polymer mortar. The surface is coated with one Bond coat polymer followed by 3 coats of two component acrylic cementatious system @ 2 KG/Sqm with required time intervals between coats and finished. The Corners to be kept 45 gsm Geotextile mesh sandwiched between layers including of cost and conveyance of all material, labour charge, cost of consumables etc. complete as per the direction of Engineer-in-Charge. |
| 166 | PROTECTIVE PLASTERING: 20mm thick in CM 1:3 adding Waterproofing admixture, dosage as per manufacturers specification to be done over the coating and finished the surface including of cost and conveyance of all material, labour charge, cost of consumables etc. complete as per the direction of Engineer-in-Charge. |
| 167 | PROTECTIVE COATING FOR UG STP TANK: The RCC surface to be wire brushed and cleaned and all cracks, loose joints, honeycombs to be sealed with Polymer mortar (Adding polymer 10% by weight of cement with cement sand mortar 1:4). The corners to be haunched with Polymer mortar. The surface is then to be coated with 2 Component Coal Tar Epoxy @ 3 sqm /kg in single coat to form 300 micron wet film thickness and finished the surface including of cost and conveyance of all material, labour charge, cost of consumables etc. complete as per the direction of Engineer-in-Charge. |
| 168 | U.G Sump & Overhead Tanks Waterproofing |
| 169 | PRESSURE GROUTING: The cold joints/honeycomb areas to be fixed with pvc nozzles 1m c/c approx or as required with Polymer mortar as per site conditions after drilling of holes of dia 14mm. The nozzles are pressure grouted with cement slurry admixed with Expansive grout admixture as per manufacturers specification at 40psi pressure and finished.The nozzles removed and holes sealed with Polymer mortar and finished the surface complete as per the direction of Engineer-in-Charge. |
| 170 | COATING (Inner): The inner surface to be wire brushed and cleaned and cracks/ construction joints repaired with Polymer mortar (Adding SBR latex to cement mortar) or crack fillers. One coat of polymer admixed with cement applied as bond coat followed by 2 coats of 2 component waterproof cementious coating and finished the surface complete as per the direction of Engineer-in-Charge. |
| 171 | PROTECTIVE PLASTERING: 20mm thick in CM 1:4 adding waterproofing admixture, dosage as per manufacturers specification to be done over the coating and finished and including of cost and conveyance of all material, labour charge for erection, cost of fixtures, cement etc. complete as per the direction of Engineer-in-Charge. |
| 172 | Terrace Waterproofing |
| 173 | The RCC SLAB surface to be wire brushed and cleaned, all loose dead mortar removed and concrete RCC Slab exposed. Cracks on the slab if found, to be V groove and filled with Polymer mortar @10 % by weight of cement to cement sand mortar in CM 1:3.The corners to be haunched 75mm by 75mm with Polymer mortar. The RCC slab surface coated with 2 coats of cementitious flexible 2 component waterproof coating with required time intervals between coats and finished. The floor to be coated and raised on the side wall 1 feet. The surface to be air/moist cured for 48 hours as per manufacturers specifications. The waterproofed surface to be done with a protective plastering of 15mm thick in CM 1:4 adding waterproofing admixture, dosage as per manufacturer's specification. Water ponding to be done for 48 hours and checked for leakages. Rates are inclusive of all materials, labour, cost of consumable etc. complete as per the direction of Engineer-in-Charge. |
| 174 | Supply and application of 145 Gsm Geotextile cloth for protection and as separation layer. It should be laid on the complete terrace and finishing the surface including all materials, labour, cost of consumable etc. complete as per the direction of Engineer-in-Charge. |
| 175 | LAYING OF SCREED CONCRETE: Providing 50mm thick (average) OR as required at site screed concrete M20 grade to proper gradient in 1:100 admixed with liquid waterproofing compound dosage as per manufacturers specification, power troweled, curing, and finished. Grooves of size 3m by 3m to be saw cut 5mm width by 10mm depth and filled with Polysulphide sealant neatly and finished. Rate all inclusive of material and labour, supply of concrete, lifting, laying till finish and others complete as per the direction of Engineer-in-Charge. |
| 176 | Supplying and erecting in position uPVC water pipes of 60 mm dia OD of 10 Kg/cm2 grade with PN-16 fittings including all specials such as bends, elbows, reducers, etc for Sewage water Treatment plant. Rate including cost and conveyance of all materials, all accessories, labour etc. complete as per direction of Engineer in Charge. |
| 177 | Providing and fixing uPVC water pipes of 168 mm dia OD & 6 Kg/cm2 working pressure including all specials such as bends, elbows, reducers, non return valves etc. including cost and conveyance of all materials, all accessories, labour. This includes jointing of pipes & fittings with one step uPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. |
| 178 | Supplying and erecting in position uPVC water pipes of following dia including all specials such as bends, elbows, reducers, etc. including cost and conveyance of all materials, all accessories, labour etc. complete. |
| 179 | 20 mm OD |
| 180 | 48 mm OD |
| 181 | 60 mm OD |
| 182 | Supplying and fixing medium duty FRP manhole cover 600x600 mm size with frame, conveyance of all materials, all labour, other incidentals, etc. complete. |
| 183 | Supplying and erecting in position UG cable including cost and conveyance of all materials, all accessories, labour etc. complete. Specification: 4-core, 10 sqmm, armed cable with Aluminium wire. For blower within plant room, 2.5 Sqmm Copper UG cable to be used and rate including conveyance of all materials, all labour, other incidentals, etc. complete. |
| 184 | Supplying and installing of lift pump in position including cost and conveyance of all materials, all accessories, labour etc. complete at all levels as per the direction of Engineer-in-charge. Make/Brand: Kirloskar/ CRI/ LubiType/Model: Self priming sludge pumpMaterial of Construction: Cast Iron (CI)HP/KW Ratings: 1 HPPipe Size: 2 inchesCapacity: 3 m3/hour at 25 m |
| 185 | Supplying and installing of centrifugal type filter feed pump in position including cost and conveyance of all materials, all accessories, labour etc. complete at all levels as per the direction of Engineer-in-charge. Make/Brand: Kirloskar/ Johnson/ WiloType/Model: CentrifugalMaterial of Construction: Cast Iron (CI)HP/KW Ratings: 1 HPPipe Size: 1.5 inchesCapacity: 3 m3/hour at 25 m |
| 186 | Supplying and installing of blowers along with common header including cost and conveyance of all materials, all accessories, labour etc. complete at all levels as per the direction of Engineer-in-charge. Make/ Brand: A1/Everest/ Akas. Model: Twin lobe blowersMaterial of Construction: CIMotor Make: Siemens/ KirloskarHP/KW ratings: 5 HPPipe size: 1.5 inchCapacity: 80 m2/hour at 3 m water depth |
| 187 | Supplying and installing MBBR media in position including cost and conveyance of all materials, all accessories, labour etc. complete at all levels as per the direction of Engineer-in-charge. Model: K3 (Khaldanes) Material of Construction: HDPE (White) Make: Aquatech International/ Cooldeck |
| 188 | Supplying and installing of fine bubble tubular diffuser in position including cost and conveyance of all materials, all accessories, labour etc. complete at all levels as per the direction of Engineer-in-charge. Model: Fine Bubble tubulara diffusers 65 dia x1000 mm Make: Anjaneya International / Cooldeck. |
| 189 | Supplying and installing of dosing pump in position including cost and conveyance of all materials, all accessories (storage tank 50 liters), labour etc. complete at all levels as per the direction of Engineer-in-charge.Make/ Brand: Aqua/ E doseType/ Model: Diaphram pumpsMaterial of Construction: Liquid contact is with PPCapacity: 0-5 LPH |
| 190 | Supplying and installing of pressure sand filter in position including cost and conveyance of all materials, all accessories, labour etc. complete at all levels as per the direction of Engineer-in-charge.Dimensions: dia 600 & Ht.>1600 mmMaterial of Construction: FRP - woovenMake: Pentair/ TataMedia: Graded Quartz sand |
| 191 | Supplying and installing of activated carbon filter in position including cost and conveyance of all materials, all accessories, labour etc. complete at all levels as per the direction of Engineer-in-charge.Dimensions: dia 600 & Ht >1600 mmMaterial of Construction: FRPMake: Pentair/ TataMedia: Activated carbon IV-1000 |
| 192 | Supplying and installing of control panel in the pump room for two lift pumps with manual changeover switch and float control, Two filter feed pumps along with float control and manual change over switch, two blower with timer controlled automatic operation , dry run protection, TOD type energy meter earthing, including cost and conveyance of all materials, all accessories, labour etc. complete at all levels as per the direction of Engineer-in-charge.Make/ Brand: L&T FittingsMaterial of Construction: MS powder coated CRCA 16 gauge sheet |
| 193 | Supplying and installing of 1.5\\" water meter (brass type) in the filter outlet including cost and conveyance of all materials, all accessories, labour etc. complete at all levels as per the direction of Engineer-in-charge. |
| 194 | Supplying and installing of ultrafiltration unit including cost and conveyance of all materials, all accessories, labour etc. complete at all levels as per the direction of Engineer-in-charge.Capacity: 4m3/hourNo. of membranes: 4No of skid: 1 (fabricated on MS)No of streams: 1Feed pump: 1 (SS - Centrifugal)Backwash Pump: 1 (Centrifugal)Make: Membrane: Hitec, Pumps: KirloskarControl panel: PLC based automatic |
| 195 | Supplying and fixing bar screen 600X600 mm size with frame, including cost and conveyance of all materials, all labour, other incidentals, etc. complete. Material of construction: SS 304, Place 8 mm SS Rods at 12 mm aprt in vertical direction. |
| 196 | Supplying, providing and fixing floor mounted white vitreous china single piece, close coupled type European water closet of approved brand / make, shape, size, pattern including all fittings and fixtures like integrated white vitreous china cistern of capacity 10 ltrs, with dual flushing system, ISI marked white solid plastic soft close seat cover and lid, cistern fitting, nuts, bolts, gaskets, SS foundation screws, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design etc. complete and cutting and making good the walls and floors wherever required, complete as per direction of Engineer-in-charge. Basic rate (without tax) for EWC- Rs. 5576/E. |
| 197 | Supplying, providing and fixing approved quality and shade vitreous Flat back Wash Basin 515x400x155 mm or nearest size, with necessary SS rack bolts one pair, 15mm CP brass pillar tap, 32mm brass waste coupling of standard pattern, 15 mm angle valve with CP inlet connection tube, CP wall flange including cutting and making good the walls & painting the brackets, cost and conveyance of all materials, labour, other incidentals etc. complete. Basic rate (without tax) for wash basin Rs. 1453/- |
| 198 | Supplying, providing and fixing approved quality and shade vitreous Counter Top Wash Basin 520x450x200 mm or nearest size with 15mm CP brass long nose pillar tap, 32 mm CP brass waste coupling of standard pattern, 15 mm angle cock including making good the walls & counter top, painting the brackets, cost and conveyance of all materials, labour, other incidentals etc. complete. Basic rate (without tax) for wash basin Rs. 2676/- |
| 199 | Supplying and fixing approved quality CP brass shower rose with 15mm or 20mm inlet and 150mm dia and 200 mm long shower arm of approved quality with all required fixtures and fittings including cost and conveyance of all materials, labour other incidentals etc. |
| 200 | Supplying, providing and fixing CP brass towel ring with concealed screws, wall flange and fitting arrangement of approved quality and brand. The rate is inclusive of cost and conveyance of all materials, labour, making good the walls wherever required and other incidentals etc. complete. |
| 201 | Supplying & fixing at site in position towel rod of approved make /quality C.P brass towel rod 600 mm size with concealed screws with all required fixtures and fittings including cost and conveyance of all materials, labour other incidentals etc. |
| 202 | Supplying & fixing at site in position C.P ablution spray health faucet with eye hook, one metre long S.S flexible tube, angle cock with wall flange all complete including cutting and making good the walls wherever required including cost and conveyance of all materials, labour other incidentals etc. |
| 203 | Supplying & fixing at site in position CP soap tray by means of screws and rawl plug embedded in the walls complete including cutting and making good the walls wherever required including cost and conveyance of all materials, labour other incidentals etc. |
| 204 | Supplying, providing and fixing in position 15mm dia CP brass long body bib cocks for tolilet with wall flange of approved quality and make, including cutting and making good the walls wherever requiredincluding cost and conveyance of all materials, labour other incidentals etc. |
| 205 | Supplying, providing and fixing in position 15mm dia CP brass Sink Cock with regular swinging spout (Wall Mounted Model), wall plate and aerator of approved quality and make, including cutting and making good the walls wherever required including cost and conveyance of all materials, labour other incidentals etc. |
| 206 | Supplying, providing and fixing Stainless Steel ISI 304 kitchen sink of size 20x17 inches with 1 mm thickness, matt finish, stainless steel waste coupling & plug 40mm with necessary fitting and sealing the joints including cost and conveyance of all materials, labour, fixing charges other incidentals etc. |
| 207 | Supplying & fixing in position CP 20 mm concealed stop cock including cost of all materials, labour, conveyance and other incidentals including cutting and making good the walls wherever required including cost and conveyance of all materials, labour other incidentals etc. |
| 208 | Supplying & fixing at site in position approved quality 15 mm dia CP angle valve with CP wall plate etc complete (For Geysers & Water Purifiers) including cost and conveyance of all materials, labour other incidentals etc. |
| 209 | Supplying and fixing bevelled edged plane edged coppered black mirror 600x450 mm or nearest available size Indian made glass and fixing the same in position with necessary plugs ans SS screws including cost and conveyance of all materials, labour, other incidentals etc. complete. |
| 210 | Supplying, providing and fixing complete set of sanitary fixtures of approved quality, brand, shape, colour and pattern for handicapped toilet, comprising of EWC, cistern with twin flush fittings, soft close seat cover, wall hung wash basin 665 x 545 x 190mm or nearest available size, one clinical faucet with spatula lever, one wall mounted hinged rail 750x100mmn and two wall mounted grab bars 600mm long. The rate is inclusive of cost and conveyance of all materials, labour and other incidentals etc. complete as per the directions of Engineer in charge. Basic rate (without tax) for wash basin - Rs. 10,759/- and for EWC- Rs. 9,611/-. |
| 211 | Supplying, installing & testing at site in position uPVC pressure pipe as per IS-4985 with solvent type joints together with uPVC pipe specials of approved quality and make. The pipes shall be duly fixed at site, with necessary cutting & jointing of pipe with approved quality jointing lubricant. The pipes shall be fixed properly aligned and suspended below toilet slabs using approved galvanized factory made pipe suspenders. Work to include supply & fixing of approved anchor Fasteners, installation of pipe suspenders to achieve necessary pipe slope, making necessary holes in the masonary walls etc. and making good the damaged portions with mortar filling with 1:4 mix. Before handing over, leak test shall be carried out and any defects found shall be rectified as per direction of Enginner -in -charge. (For Soil & waste pipes -Inside Toilet) |
| 212 | 160mm OD (6kg/cm2) |
| 213 | 110mm OD (6kg/cm2) |
| 214 | 75 mm OD (6kg/cm2) |
| 215 | 50 mm OD (6kg/cm2) |
| 216 | 40 mm OD (6kg/cm2) |
| 217 | 32 mm OD (10kg/cm2)- for sunken drain |
| 218 | Supplying, installing & testing at site in position uPVC pipe (SWR) of type B (IS-13592) with SWR rubber ring fittings of approved make. The pipes shall be duly fixed at site with necessary cutting & jointing of pipe with approved quality jointing lubricant. The pipes shall be fixed properly aligned vertical with suitable Galvanised steel slotted rail, threaded rods, clamps, hangers etc. Work to include making necessary holes in the masonary walls and making good the damaged portions with mortar filling with 1:4 mix. Before handing over, leak test shall be carried out and any defects found shall be rectified as per direction of Enginner -in -charge.(For Vertical & Horizontal Shaft piping). |
| 219 | 160mm OD |
| 220 | 110mm OD |
| 221 | 75 mm OD |
| 222 | Supplying, installing & testing at site in position uPVC pipe for rain water & vent system conforming to IS : 13592 Type A with rubber ring jointed ends and fittings (moulded as well as fabricated) including cutting the pipes to size, jointing the pipes and fittings, erection of the pipes plumb in shafts and elsewhere, making end connections at both the gratings and gutters / channels at ground level etc., The work shall include supply and fixing of necessary angles/channels for supports, chasing of walls, grouting of supports, painting of supports etc., complete. |
| 223 | 160mm OD |
| 224 | 110mm OD |
| 225 | 75 mm OD |
| 226 | Supplying, providing and fixing uPVC type of 110x75 mm dia SWR trap (Multi trap) of self cleaning design including cost of cutting and making good the cutouts in walls and floors etc. wherever required complete.110 mm inlet and 75 mm outlet (Deep Seal trap) |
| 227 | Supplying, providing and fixing Heavy Class SS grating of size 125x125 mm of approved design including setting in floor with cement motor to match with floor finish as per architect requirement includes cost and conveyance of all materials, labour and other incidentals etc. complete. |
| 228 | Supplying & Installing at site in position 125x125 mm square cast SS (304 grade) cleanout with Teflon gasket & SS key for opening, complete in all respects. The rate includes cost and conveyance of all materials, labour and other incidentals etc. complete. |
| 229 | Supplying, installing, testing and commissioning at site in position PVC Cleanout (6 kg/cm2) for soil & waste pipes including all necessary fittings and specials such as Ys/ 45 Bend etc. complete for ceiling/ wall suspended lines. The rate includes cost and conveyance of all materials, labour and other incidentals etc. complete. |
| 230 | 160 mm |
| 231 | 110 mm |
| 232 | 75 mm |
| 233 | Providing, fixing, jointing and testing schedule 40 high pressure uPVC pipes pasting type conforming to ASTM-D-1785 (sizes in ID) of approved make for flushing, domestic and drinking water supply cut to required lengths with all necessary fittings and schedule 40 specials for cold water supply, by cutting, threading and fixing in/on walls, ceiling, under floor etc. as per drawing with clamps at 1.00 m spacing including all uPVC plain & brass threaded fittings. The rate includes jointing of pipes & fittings with one step uPVC solvent cement and testing of joints complete as per direction of Engineer in Charge.( Exposed on wall, shafts and terrace) |
| 234 | 15mm dia |
| 235 | 20 mm dia |
| 236 | 25 mm dia |
| 237 | 32 mm dia |
| 238 | 40 mm dia |
| 239 | 50 mm dia |
| 240 | 65 mm dia |
| 241 | 80 mm dia |
| 242 | 100 mm dia |
| 243 | Providing, fixing, jointing and testing Chlorinated Polyvinyl Chloride (CPVC) pipes as per ASTM D-2846, SDR 11 having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00m spacing. The rate includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases using mechanized cutter tools, and making good the walls and testing of joints complete as per direction of Engineer in Charge.(Concealed work.) |
| 244 | 15 mm dia |
| 245 | 20 mm dia |
| 246 | 25 mm dia |
| 247 | Supplying, Installing and Testing of full way lever operated bronze body chromium plated / stainless steel Ball valve of approved make with necessary fittings in position as per drawings. |
| 248 | 20 mm dia |
| 249 | 25 mm dia |
| 250 | 32 mm dia |
| 251 | 40 mm dia |
| 252 | 50 mm dia |
| 253 | Supplying, installing, testing & commissioning at site in position Butterfly valve (PN 10) wafer type of approved make with necessary PVC flanges, gaskets, nuts and bolts etc complete within position as per drawings. |
| 254 | 65 mm |
| 255 | Supplying, installing & testing at site in position spring loaded vertically mounted 20 mm brass Air Release Valves of approved quality and make on the top of the vertical water supply pipes as per specification and drawings. |
| 256 | Supplying, installing, testing & commissioning at site in position 50 mm dia gun metal / bronze body Pressure Reducing Valve suitable for a maximum inlet pressure of upto 25 bars reduce to anywhere between 1 to 1.5 bars, the valve incorporate inherent design advantage like reversible double reinforced food grade EPDM rubber diaphragm, pressure gauge connections on both sides of valves etc complete. |
| 257 | Supplying, installing, testing & commissioning at site in position 50 mm dia Bronze Non - Return Valve screw type. Rate including cost and conveyance of all materials, labour, other incidentals etc. complete. |
| 258 | Supplying, installing & testing at site in position 25 mm dia MultiJet watermeter of removable mechanism type, magnetically coupled, having dry dial, hermetically sealed totaliser, retrofitable for pulse output and Class B type. Rate including cost and conveyance of all materials, labour, other incidentals etc. complete. |
| 259 | Supplying, installing & testing at site in position uPVC pressure pipe as per IS-4985 (class-III) with solvent type joints together with uPVC pipe specials of approved quality and make, the pipes shall be duly fixed at site, with necessary cutting & jointing of pipe with approved quality jointing lubricant. The pipes shall be fixed properly aligned. Work to include laying the pipe to the designed slope and joining into inspection chambers including making holes in the masonary walls etc. and making good the damaged portions with mortar filling with 1:4 mix. Before handing over, leak test shall be carried out and any defects found shall be rectified. Work shall also include necessary excavation and back filling with compaction etc.complete. |
| 260 | 200 mm OD (6kg/cm2) |
| 261 | 160mm OD (6kg/cm2) |
| 262 | 110mm OD (6kg/cm2) |
| 263 | 75mm OD (6kg/cm2) |
| 264 | Supplying and fixing best quality PVC vent cowl of approved brand with mosquito proof net covering at all height including cost and conveyance of all materials, labour, other incidentals, etc. complete |
| 265 | 160 mm |
| 266 | 110 mm |
| 267 | Supplying, installing, testing & commissioning at site in position brick masonry manholes with 75 class designation bricks in cement mortar 1:4 and plastering the inside and outside the chamber with cement plaster 12 mm thick 1:3 ratio and inside with a floating coat of neat cement. 15cm thick R.C.C provided at the top of 1:1.5:3 mix for fixing manhole frame; foundation concrete 1:4:8 mix (1cement: 4 coarse sand: 8 graded stone aggregate 40mm nominal size) and making channels in cement concrete 1:2:4 mix. Rate including cost of all material incl cost of cement, all labour charges, excavation, back filling and disposal of surplus complete as per direction of Engineer-in-charge. |
| 268 | 60x60 cm internal dimension and 75 cm deep |
| 269 | 90x90 cm internal dimension and depth upto 90cm |
| 270 | 90x120 cm internal dimension and depth upto 120 cm |
| 271 | Construction of catch basin of size 450mm x 450mm (clear internal dimension) for external storm water drainage with 200 mm thick walls in solid block in cement mortar 1:4 over a bed of 100 mm thick PCC 1:4:8 grade internal walls plastered smooth in cement mortar 1:3 and external walls plastered in flushed to the finished floor level with including fixing MS/Ductile fabricated grating as shown the drawing necessary excavation, back filling to selected excavated with all leads and lifts etc. complete including including cost of all material incl cost of cement, all labour charges and disposal of surplus complete as per direction of Engineer-in-charge. (Depth upto 1000 mm) |
| 272 | Laying in position PVC gully trap size 150 x 100 mm with 100 mm outlet including embedding trap in cement concrete 1:3:6 and constructing chamber of size 300 x 300 mm (inside clear) in brick masonry, 15 mm thick plaster with cement mortar (1:3) on both internal and external surfaces, inside finished with floating coat of neat cement. Fixing C.I frame and cover 300 x 300 mm (clear opening) weight of cover not less than 4.50 kg and frame not less than 2.7 kg painted with 2 coats of anti-corrosive black bitumastic paint etc., complete. The work shall include necessary excavation and backfilling. |
| 273 | Supply, installation, testing and commissioning of water transfer pumps monoblock type of adequate HP, capable of giving a required discharge at suitable head to work on 3Ph 50Hz, '400/440V with necessary unions, flanges, with necessary cabling, DOL (upto 7.5 kw) / stardelta starter panel, all material cost, labour charges for fixing and other incidental charges etc. complete as per direction of Engineer-In-Charge. (1 Set = 1 Working + 1 Standby) Material of Construction; Impeller : Cast Iron, Delivery Casing : Cast Iron, Shaft : SS. Duty Conditions; Discharge: 6 LPS, Total Head: 65 m. |
| 274 | Supplying and fixing at site in position fabricated uPVC Puddle flanges of SCH 40 in the underground and overhead water tanks as per the drawings and the requirement of the Engineer-In-Charge. |
| 275 | 200 mm OD |
| 276 | 150mm OD |
| 277 | 100 mm OD |
| 278 | 80mm OD |
| 279 | 63 mm OD |
| 280 | 50 mm OD |
| 281 | 32 mm OD |
| 282 | 25 mm OD |
| 283 | Supplying and fixing in position self pigmented type double seal (air & water tight) FRP manhole cover and frame with closed bottom, lifting key holes & load tested for under ground sump and over head tank. Rate including cost and conveyance of all materials, labour, other incidentals etc. complete. |
| 284 | 600x600mm -Light Duty for OHT (5 MT) |
| 285 | 600x600mm -Heavy Duty for UGS & drainages (25 MT) |
| 286 | 900x900mm -Heavy Duty for UGS (25 MT) |
| 287 | Core cutting in RCC floor slabs using diamond core cutting machines of required diameter and necessary skilled labours. The core drilling shall be executed only after necessary approval of shop drawings. The drill diameter shall be suitable over-sized to take in the below specified sewer pipes. the cutting of reinforcement bars shall not be permitted without prior approval. Rate including labour, tools, equipments, water supply protection of surrounding surfaces, collection and disposal of debris and makinfg good the surface, complete as per drawing, specification, and instruction of Engineer in Charge. |
| 288 | 160 mm |
| 289 | 110 mm |
| 290 | 75 mm |
| 291 | 50 mm |
| 292 | 32 mm Please Enable Macros to View BoQ information |
| 293 | 32 mm Please Enable Macros to View BoQ information |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
| 5 | Click here to download tender document | Tender Documents |
| 6 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail