Sales : +91-777 804 8217
| Sl. No. | Item Description |
| 1 | BLDG WORK |
| 2 | Chipping off existing loose, damaged Concrete from RCC members of all affected RCC Columns, Beams, Slabs and Chajjas on External and internal facades, etc beyond main reinforcement carefully with chisel and hammer providing and applying ‘Rusticide SS’ Rust passivator to existing reinforcement bars Including wire brushing of reinforcement , cleaning washing of concrete etc complete as directed.Providing and applying two coats of rust preventor slurry made out of “Polyalk Fixoprime” or equivalent as specified in the Brand Names and cement in proportion 1:1.5 to existing reinforcement bars as directed complete. Providing and applying bonding coat of slurry made out of “Polyalk EP” or equivalent as specified in the Brand Names and cement in proportion 1:1 to concrete and reinforcement substrates complete as directed Providing and applying “Polyalk EP” or equivalent as specified in the Brand Names.Polymer modified cement mortar in Required proportions(1:5:15) to RCC members Including Hand packing, curing and making the surface rough for plastering complete all as specified and directed by Engr-in-Charge. |
| 3 | Providing and laying Super fluid Microconcrete -Roffe crete repairs (or equivalent as specified in the List of Brand names) in beam bottoms, columns, slabs etc. including chipping off loose concrete from RCC members of all affected RCC Columns, Beams, Slabs and Chajjas on External and internal facades, etc beyond main reinforcement carefully with chisel and hammer, Providing and applying ‘Rusticide SS’ Rust passivator or equivalent as specified in the Brand Names to existing reinforcement. bars Including wire brushing of reinforcement , cleaning washing of concrete etc complete as directed, Providing and applying two coats of rust preventor slurry made out of “Polyalk Fixoprime” , bond coat of polymer & cement in ration 1:1, providing waterproof ply wood/ steel plate shuttering, pouring, temping, Consolidating, curing etc complete as per Manufacturer’s specification complete all as specified and directed by Engr-in-Charge. |
| 4 | Providing & fixing epoxy dipped shear keys of 10mm dia and 4\\" to 6\\" length in columns before jacketing, Micro concreting complete all as specified and directed by Engr-in-Charge. |
| 5 | Providing, cutting, bending and fixing Additional Reinforcement in position steel reinforcement of specified/required sizes and shapes in the form or main rebars, stirrups & rings, distribution rebars etc., and tying them to shear connectors using GI binding wire. The additional rebars shall be coated with TWO coats of Anti Corrosive protective coating & dry sand to be sprinkled on second coat including tying with Annealed Binding wires, providing cover blocks of appropriate sizes etc complete all as specified and directed by Engr-in-Charge. |
| 6 | GLASS FIBER WRAPPING SYSTEM:.Providing & laying applying glass fiber sheet wrap of minimum 600 gsm over structural members including.surface preparation: grinding / moulding concrete substrate, cleaning it with wire brush, removing oil, laitance if present, rounding sharp edges to min 25 mm radius etc., complete.profiling: applying primer on prepared substrate, filling holes and uneven surface with putty etc., complete.wrapping: wrapping the glass fibre wrap to structural element at desired orientation using tamping roller to avoid any air voids etc., repeat the same procedure for multiple layer with interval of 8 hours.sand pasting: applying saturant, rectify air voids if any, paste the river sand on it to make surface rough to take any further finishes.(mode of measurement: per sq.mt of fiber consume and not application of surface area) complete all as specified and directed by Engr-in-Charge. |
| 7 | Providing and laying in position plain cement concrete of specified grade cement with /granite/quartzite/gneiss metal mixing in concrete mixer including bailing out water,compacting, finishing surface, curing and including the cost of centering and shuttering at all level Nominal Mix of 1:1:2 (1 cement OPC: 1 coarse sand : 2 graded stone aggregate 20 mm nominal size) complete all as specified and directed by Engr-in-Charge. |
| 8 | Supplying, Drilling/Cleaning hole and injecting Hilti make ETA Approved HY-200-R chemical. Application to be designed separately for Rebars as Simply Supported, Moment or Splice Connection as per EC2/TR 023 or relevant tested and accepted rebar guidelines. The chemical should have ETA approval for seismic rebar as a minimum qualifying criterion. Drilling hole with double flute type drill bits or hollow drill bits to the required depth by rotary hammer drill, cleaning with brush and jet of clean air, filling resin and hardener using serrated nozzle to eliminate mixing error with standard HDE A22 battery dispenser along with piston plug. The installation and the setting instructions should be strictly followed as per the manufacturer’s recommendations. The adequate diameter and embedment of rebars to be decided as per PROFIS Rebar Software & the report to be submitted to the GE for approval. Scanning before drilling to be done to avoid hitting existing rebars. HY200 -10 mm dia 200mm depth.(Including required scaffolding) |
| 9 | RELIEVING STRUCTURAL MEMBERSRelieving Structural members such as column, beam and slabs of their superimposed loads partially or fully by provision of adjustable steel props, frames etc. including providing necessary timber runners, bracing, jacking up arrangement complete all as specified and directed by Engr-in-Charge. (Removing and redoing of brickwork, if required, shall be paid separately) |
| 10 | FILLING AND REINSTATING OF SEPARATION CRACKSOpening the Separation Cracks at the Junction of RCC and Masonry where ever directed and instructed into ‘’V’’ Grooves 2’’ to 3’’ from the either side of the cracks and 20-25mm wide and 15-20mm in depth by carefully marking the areas to be opened up using a Cutting machine and skillfully /carefully Chiseling with a well sharpened chisel and hammer as directed including Wire brushing and washing of concrete Substrata and masonry walls with water jet to the surfaces thus prepared to the entire satisfaction complete all as specified and directed by Engr-in-Charge. |
| 11 | Moistening the Cracks, Providing and applying priming/bonding coat of slurry made out of “Polyalk EP”and cement (or equivalent as specified in the List of Brand names) in proportion 1:1 to surfaces prepared as instructed and directed. Filling the Cracks /Grooves by Providing and applying “Polyalk EP” Polymer modified cement mortar in Proportion of 1: 5: 15 (Polyalk EP: Cement: Graded sand/quartz sand) on the prepared surfaces and finishing it in level with the existing plaster Including Hand packing, curing and making the surface similar to the external plastering using wooden floats/punch complete all as specified and directed by Engr-in-Charge. |
| 12 | Drilling holes of required size upto 16 mm Diameter and up to 50mm depth in concrete and cleaning the same as directed. |
| 13 | Providing and fixing 12 mm diameter aluminum /PVC injection nipples and securing the same as directed & Providing and injecting cementitious grout using CEBEX-112 additive of ‘Fosroc’ or equivalent material of Asian Paints (Dr Fixit/STP/Thermax) at the rate of 225 grams per bag of cement and using suitable mechanical gun/pump including mixing etc complete. |
| 14 | Demolition brick work in lime or cement mortar including plaster, paint, etc. manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge. |
| 15 | Taking down cement or cement lime plaster on brick walls incl racking out joints hacking for key scrubbing down with water etc complete all as specified and as directed |
| 16 | M&L for rendering 15mm thick (In two coats 10mm + 5mm) in CM 1:4 on fair faces of brick work or concrete surfaces finished even and fair with out using extra cement upto four storey complete all as specified and directed |
| 17 | M&L for rendering 10mm thick in CM 1:6 on other than fair faces of brick work or concrete surfaces finished even and smooth without using extra cement up to four storey height bldg complete all as specified and directed |
| 18 | M&L for rendering 5mm thick in CM 1:3 on ceiling surfaces finished fair and even smooth without using extra cement complete all as specified and directed |
| 19 | M&L for complete removal of existing treatment on external & internal wall surfaces (old plastered surfaces) complete all as specified and directed |
| 20 | M&L for Providing and applying 1 to 2 mm thick wall care putty on wall plastered surface/concrete surface and prepare the surface even and smooth complete all as specified and directed |
| 21 | M&L for preparation of new surfaces of walls, and applying Two of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces. to four storey bldgs complete all as specified and as directed. |
| 22 | M&L for preparation of old plastered surface of walls, and applying Two of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces. to four story bldgs complete all as specified and as directed. |
| 23 | M&L for preparation of new surfaces of walls, and applying two coats of distemper oil emulsion over a coat of alkali resistant primer on wall surface complete all as specified and directed |
| 24 | M&L for preparation of new plastered or unplastered surface and applying three coats of white wash on wall complete all as specified and directed. |
| 25 | M&L for preparation of new plastered surface and applying two coats of white wash on ceiling surfaces complete all as specified and directed |
| 26 | Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off thepremises complete all as specified and directed |
| 27 | M&L for Vitrified Ceramic tiles 9mm to 10mm thick light shade (square/ rectangular) polished, area of each tiles not exceeding 0.36 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match and including 15mm thick screed bed in cement mortar (1:4) complete all as specified and directed |
| 28 | All as per above item on vertical surface such as skirting/dado, including Rendering/backing coat 10mm thick in CM 1:4 |
| 29 | M&L for Non-skid Ceramic coloured tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 15 mm thick screed bed in cement mortar (1:4) complete all as specified and directed |
| 30 | M&L for Glazed ceramic coloured tiles in vertical surface 450X 350X 6mm to 7mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match including backing/rendering 10 mm thick in cm 1:4 complete all as specified and directed |
| 31 | M&L for Rubber moulded chequered tile glossy finished (Size 30cm x 30cm) x 22mm to 25mm thick, machine pressed; set jointed and pointed in neat cement slurry in floors, with grey cement and color pigment and cut and polished laid over including 15 mm Screed bed or bedding layer of CM 1:4, complete all as specified and directed |
| 32 | Demolition to stone slab and granite laid bedded and pointed in any mortar of any description or thickness in floors/pavings/cladding etc and removing the debries outside the MOD land complete all as specified and directed |
| 33 | M&L for 18-20mm thick Granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window cills, cooking platforms and like laid over and including 15mm thick screed of cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite and incl providing edge moulding complete all as specified and directed |
| 34 | Taking down Chowkats or frames with shutters (without taking off shutters from the frame) area n exc 1.5 sqm each complete all as specified and directed |
| 35 | Taking down Chowkats or frames with shutters (without taking off shutters from the frame) area exc 1.5 sqm and not n.exc 4.0 sqm each complete all as specified and directed |
| 36 | Providing and fixing factory made uPVC white colour casement (Openable) Door made of extruded profile wilh wall thickness of 2.3mm ( + -0.2mm). Windowprofile with hollow section with mitlti chamber, frame (60mm x 58mm), sash (60mm x 78mm). T profile (One vertical length in between two shutters) (60mm x74mm). Glazing bead (35mm x 20mm) will be mitered cut and fusion welded at all corners, including drilling ol holes for fixing hardware and drainage of water etc., making arrangement for fixing of hardware.EPDM gasket 1.2 + -0.2mm thick galvanized steel Frame (28mm x 21.5mm), sash (31mm x 27mm), T profile (27mm x 17mm) to be inserted in required profile, frame will be fixed to the wall wilh 8mm x 100mm long fasteners. Hardware: [casement door handle made of zinc alloyed (white powder coated). Corner striker. Secondary Strikers. Cylinder. Door transmission gear made of mild sleel with multi point locking system with strikes. 3D Hinges of zinc alloyed (white powder coated) [and 5mm thick glazing with selected quality glass.(Note: The unit rate quoted by contractor excludes cost of glass and includes all other connected accessories. Net opening will be measured for payment purpose.) |
| 37 | S&F aluminium powder coated any colour (minimum thickness of powder coating 50 micron) frame (sliding and shutter type) for doors, windows, partician, ventilators with one or more rebates including joining cleat for fixing etc. complete all as specified and directed |
| 38 | S&F for powder coated aluminium doors , (thickness of powder coating not less than 50 micron) alumonium section weighing 0.55 kg/m incl necessary joining cleats, glazing clips, rubber neoprene packing, handels 2 Nos in each door, anodised aluminium snap beading screws etc. complete all aspecified and directed |
| 39 | Supply and fix powder coated aluminium anodised aluminium window and ventilator shutters, side hung/top hung type without sash bars, aluminium sections weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws,nodised aluminium fittings such as peg stays 150mm long (1 no.). hinges type B-21 100mm long (2 no.) suitable handle(1) complete all as specified and directed. |
| 40 | Supply and fix powder coated aluminium anodised window sliding fixed type without sash bar, aluminium section weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws and handlesetc complete all as specified. Note:-(i) Sheet glass/wire gauge panels will be measured and paid separately. (ii)The rate quoted shall be deemed to be included cost of provn of hold fasts, PCC for fixing hold fasts, making good the disturbed surfaces in CM 1:4 and finishing work as per existing. |
| 41 | S&F for powder coated anodised aluminium grill (anodised transparent or dyed to required shade according to IS: 1868 with minimum anodic coating of grade AC 15) of approved design/pattern, with approved standard section and fixed to the existing window frame with C.P. brass/ stainless steel screws @ 200 mm centre to centre, including cutting the grill to proper opening size for fixing and operation of handles and fixing approved anodised aluminium standard section around the opening, complete all as per requirement and direction of Engineer |
| 42 | S&F 12mm thick interior grade particle board prelaminated on both sides as in panel of door shutters partition wall, work stations including beading etc complete all as specified and directed |
| 43 | S & F sheet glass 5.5 mm thick of selected quality (tinted glass) n exc. 0.5 sqm each fixed to aluminium frame work with necessary rubber beading complete all as specified and directed by Engineer in Charge,. |
| 44 | S & F sheet glass 5.5 mm thick of selected quality (tinted glass) exc. 0.5 sqm each fixed to aluminium frame work with necessary rubber beading complete all as specified and directed by Engineer in Charge,. |
| 45 | S&F for Factory made single extruded WPC (Wood Polymer Composite) solid door/ window/ Ceosetory windows & other Frames/ Chowkhat of size 45 x 70 mm comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/ cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2, modules of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/ moisture proof and fire retardant and fixed in position with MS hold fast/ lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-in-Charge. (M.S. hold fast/ lugs or SS dash fasteners shall be paid for separately). Note: For WPC solid door/window frames, minus 5mm tolerance in dimension i.e. depth and width of profile shall be acceptable. Variation in profile dimensions on plus side shall be acceptable but no extra payment on this account shall be made. |
| 46 | S&F for Factory made single extruded WPC (Wood Polymer Composite) solid plain flush door shutter of 30mm size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2, modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixing with stainless steel butt hinges of required size withnecessary full body threaded star headed counter sunk S.S screws, all as per direction of Engineer-In-Charge. (Note: stainless steel butt hinges and necessary S S screws shall be paid separately) complete all as specified and directed |
| 47 | S&F for 100mm long butt hinges medium weight, mild steel, and fixed complete all as specified and directed |
| 48 | S&F aluminium body mortice lock vertical type size 100mm 4 lever, including escutcheon plate and two No keys fixed complete all as specified and directed by Engr-in-Charge. Make : Godrej/Harison/Dorset/Europa |
| 49 | S&F for 125mm long aluminium anodised, barrel tower bolts of ex-truded section and fixed complete all as specified and directed |
| 50 | S&F for 125mm long Extruded aluminium alloy handles, fabricated type,anodised complete all as specified and directed |
| 51 | S&F for 250mm long aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixed complete and specified and as directed |
| 52 | S&F Aluminium (extruded section body) Door closer hydraulically regulated, designation No. 3, universal type, suitable for door shutters of 851 to 1000 mm in width and of weight between 61 to 80 kg and fixed complete all as specified and directed |
| 53 | Dismantling of ceiling /wall panelling including frame work and board complete all as specified and directed |
| 54 | S&F false ceiling at all heights with GRG (Glass Fibre Reinforced Gypsum) false ceiling tiles of Size 595 x 595 mm of approved texture,design and patterns with semi perforated 12mm thick micro tegular edged GRG false ceiling tiles having moisture content less than 2%, humidity resistance of 99%, NRC0.50 to 0.75 as per IS 8225:1987, Noncombustible as per BS 476 (part 4 )-1970 and light reflectance of 85% (minimum) to be laid in true horizontal level suspended on inter locking metal T-Grid of hot dipped galvanized iron section of 0.33mm thick (galvanized @ 120 grams per sqm including both sides) comprising of main T runners of size 15 x 32 mm of length 3000mm,cross-T of size 15x 32mm of length 1200mm and secondary intermediate cross-T of size 15 x 32 mm of length 600mm to form grid module of s1ze 600x 600mm ,suspended from ceiling using galvanized mild steel items (galvanizing @ 80 grams per sqm) i.e 50mm long, 8mm outer diameter M-6 dash fasteners, 6mm dia fully threaded hanger rod upto 1000mm length and L shape level adjuster of size 85x25x2mm. Galvanised iron perimeter wall angle of size 24x 24x0.40mm of length 3000 mm to be fixed on periphery wall I partition with the help of plastic rawl plugs at 450 mm center to center and 40mm long dry wall wood screws. The work shall be carried out as per specifications, drawing and as per directions by GE, Everest ceiling and grid system Regular T-2430 or its equivalent Make of \\"Ramco/Charminar/Armstrong\\" |
| 55 | S&F false ceiling with lay in Tegular bevelled edge powder coated galvanised steel ceiling tiles having zinc coating of 120 gsm and white powder coating of 60-80 microns in size 600x600x0.5 mm plain in white colour, with a backing of factory pressed black glass tissue, to be laid on exposed grid system 15/24 mm comprising of main runner, cross tees and wall angle.Main Runners And Cross Tees shall conform to the requirements of a heavy-duty classification in accordance with ASTM C-635. They shall be rolled with a double web and a rectangular bulb from Hot Dipped Galvanized steel, minimum .020\\" thick, to an overall height of 1-1/2\\" with a flange width of 15/16\\".Supporting the main runners shall be 12 gauge galvanized steel wire hung on minimum 48\\" centers from the structure above the ceiling.Compression Struts shall be composed of telescoping 1/2\\" diameter and 3/4\\" diameter steel galvanized tubing. The 1/2\\" diameter tube shall be notched on one end to fit over the bulb of the main runner. At the other end, a length of 3/4\\" diameter tube is to be telescoped over the top portion of the 1/2\\" diameter tube and screw fastened to it with two (2) 3/8\\" long TEK screws so that the top of the 3/4\\" diameter tube bears on the structure above and the bottom of the 1/2\\" diameter tube fits snugly over the bulb of the main runner. A compression strut is required at each hanger wire and shall be tied to the hanger wire at the top and bottom. |
| 56 | M &L for PVC profile for wall panelling colour / shade as approved size 250mm wide, 08 mm over all thick with 1 mm wall thickness fixed with screw to mild steel square ( size 20mmx 20mmx 1mm thick) tubler frame work including one coat of red oxide primer, fixed to walls complete all as specified and directed by Engr-in-Charge. |
| 57 | M&L for PVC profile corner beading L/T profile for wall panelling, colour/shade matching with wall panelling complete all as specified and as directed |
| 58 | Dismantling of existing water tank and removing from site and S&F for Rotational moulded PVC water storage tanks of 1000 Ltr capacity, cylindrical vertical with closed top hoisted three layred, white colour as per IS and fixed in postion including necessary fittings complete all as specified and as directed |
| 59 | S&F for 20 mm dia Ball brass valves, high pressure, with polythene float and flynut complete, screwed for iron pipe orr brass ferrule and fixed complete all as specified and directed |
| 60 | Taking down eaves gutters and rainwater pipes (any size or pattern), including all fittings,heads, shoes, bends, swan-necks, etc., including cleaning or refixing or removal to Store (measured overall as fixed along the centre line over fittings and accessories) |
| 61 | S&F for PVC (SWR) pipes 110mm single socketed, ISI marked in any length with solvent cement joints fixed to walls/laid in floors complete all as specified and directed |
| 62 | S&F for PVC SWR bends 110mm bore, ISI marked complete all as specified and directed |
| 63 | S&F for 110 mm dia pvc pipe Stack clamps out of 50 mm by 5mm flat iron and 16mm dia round iron stays, inlcuding bolts and nuts and securing ends of stays to wall or roof as per complete all as specified and directed by Engr In Charge. |
| 64 | S&F in repair modular partition workstation single seating in 45mm thick with prelaminated top of 25mm thick as per color approved. Workstation having glass/fabric/white board pratition above the top of the table, with three drower mobile pedestal, keyboard and CPU trolley. Overall size for per seat 1200x600x1200mm. (single seat) Make Royal Koas, Model No ESC/WS/009 or equivalent model of Godrej/Featherlite/Methodox/Durian. |
| 65 | S&F in repair modular partition workstation Double Seating in 45mm thick with Prelaminated top of 25mm thick as per color approved. Workstation having glass/fabric / white board partition on the top of the table.With Mobile pedestal, keyboard and CPU trolley . Overall Size for per seat : 1200x600x1200mm. Make Royal Koas/Godrej/Featherlite/Methodox/Durian. |
| 66 | Demolition and complete removal of existing roof treatment with brick tiles or terracing tiles, single layer on roofs including bedding layer in cement mortar/plastreing/leeping (whether full thickness removed or only a part thereof) complete all as specified and directed |
| 67 | M&L for cement concrete type B0 1:2:4 using 12.5mm graded stone aggregate in roof kerbs or mud stops, padding, rounded or chamfered on edges without using extra cement complete all as specified and directed |
| 68 | Supply only liquid water proofing compound complete all as specified and directed |
| 69 | (i) Providing and laying/fixing TPO (Thermoplastic Polyolefin ) waterproofing membrane on prepared surface of roof and upto 300mm of parapets and crumple joint including junction of roof and parapet.Method : Cleaning the surface and laying FOSROC Proofex ORG (minimum 1.2mm thick for in-accessible roof/2mm for accessible roofs) over a min 200 GSM Geo textile or Asian Paints TPO or equivalent product of M/s MC Bauchemie / CIPY / SIKA / Pidilite Dr Fixit TPO membrane, applied as per manufacturer's instructions.(ii) The work shall be carried out complete as per manufacture's instructions and application methodology. Execution to be done with authorized trained/skilled applicator of manufacturer as per the technical guidelines laid by manufacturer 10 years Company back guarantee to be given by contractor after completion of water proofing work before payment. |
| 70 | S&F Heat Resistant Terrace Tiles (300 mm x 300 mm x 18mm to 20 mm) with SRI (solar refractive index) > 78, solar reflection > 0.70 and initial emittance > 0.75 on waterproof and sloped surface of terrace, laid on 20 mm thick cement sand mortar in the ratio of 1:4 (1 cement : 4 coarse sand) and grouting the joints with mix of white cement & marble powder in ratio of 1:1, including rubbing and polishing of the surface upto 3 cuts complete, including providing skirting upto 150 mm height along the parapet walls in the same manner. |
| 71 | S&F for expansion/crumple joint treatment of EPDM/polymer polyband water proofing membrane of 1.5mm thick and width of 200mm affixed with epoxy resin adhesive on crumple gaps and including over top surface finished of 2mm thick aluminium cover plate width of 250mm duly holed and capsule slotted on either side and fixed with ss screw etc complete all as specified and directed |
| 72 | S&F for expansion/crumple joint treatment of EPDM/polymer polyband water proofing membrane of 1.5mm thick and width of 200mm affixed with epoxy resin adhesive on crumple gaps and including over top surface finished of 2mm thick ss cover plate (304 grade) width of 250mm duly holed and capsule slotted on either side and fixed with ss screw etc complete all as specified and directed |
| 73 | S&F for plain galvanised steel sheeting 1mm thick and 250mm wide to covering the crumple/expansion joint/gaps on vertical/horizontal surface, steeped flashing or by fixing screws etc complete all as specified and directed |
| 74 | S&F 20mm bore medium grade galvanising steel water tubing ISI marked with all fittings and fixed to walls and ceiling or laid in floors complete all as specified and directed |
| 75 | S&F 15mm bore medium grade galvanising steel water tubing ISI marked with all fittings and fixed to walls and ceiling or laid in floors complete all as specified and directed |
| 76 | S&F in repairs Wash basins, Vitreous China (flat back or angle back type)any size, including cutting for and pinning in ends of brackets or erecting stand butexclusive of fixing of supply and waste pipe complete all as specified and directed |
| 77 | S&F in repair PVC SWR floor trap with grating including jointing with solvent cement 75 mm dia complete all as specified and directed |
| 78 | S&F in repair for Vitreous China bowl urinal flat back, size of 465 x 355 x 265 mm half stall type white (minimum), with grating and union for discharge pipe complete all as specificed and directed |
| 79 | M&L for Vitreous china urinal partition white of size 310x700 mm complete as specified as directed |
| 80 | S&F in repair for vitreous china wash down water closet pan, white (pedestal pattern), including plastic water closet seat, white, closed pattern with recessed bottom and cover and mild steel chromium plated or aluminised hinging device, excluding fixing bolts, flushing cistern and flush pipe) complete all as specified and directed |
| 81 | S&F 10 ltr capacity PVC valveless, syphonic action type, flushing cistern,low level, white, with inlet, ball valve, float and handle including brackets Flush pipe of polyethylene of low or high density or PVC. 32 mm dia, for low level cistern complete all as specified and directed |
| 82 | S&F in repair 15mm dia PVC Connection 600mm long with nuts complete all as specified and directed |
| 83 | S&F for health faucet (ABS Body) mild steel chromium plated suitable for 15 mm dia pipe with 1.25 metre long flexible tube and ABS wall hook including makingconnections and fixed in position complete all as specified and directed |
| 84 | S&F in repairs 15 mm bore bib taps chromium plated and fancy type quarter turn with crutch or butter fly handle high pressure screwed down for pipes etc complete all as specified and directed |
| 85 | S&F in repairs 15mm Pillar taps, cast copper alloy, with capstan heads,chromium plated, quater turn screwed down high pressure, with or without lettered 'Hot' or 'Cold' with long screwed shanks and fly-nuts, screwed for iron pipe etc complete all as specified and directed |
| 86 | S&F in repairs angle valve ,stop valve, cast copper alloy, chromium plated with crutch or butterfly handle, fancy type, quarter turn screwed both ends for iron pipe of 15mm bore. complete all as specified and directed |
| 87 | S&F 600mmx450mm bevelled edge mirror of selected quality glass, mounted on 6mm thick AC building board or commercial plywood and fixed to wooden plugs with chromium plated brass screws and cup washers complete all as specified and as directed |
| 88 | Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and directed |
| 89 | S&F for framed work such as grills, gratings, etc. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars;barred iron doors; ladders; drain cover grating, framed balusters; walk ways; railings; cooler stand, framework of water tanks and similar work con- forming to Fe.290.Gde-E-165 complete all as specified and directed |
| 90 | M&L Preparation of new steel surfaces of any description, over 10 cm in width or girth, not otherwise described and applying two coats of synthetic enamel paint over a coat of red oxide/ zinc chrome primer up to four storey height building chromate complete all as specified and directed |
| 91 | M&L for 2mm Fibre glass reinforced translucent corrugated sheeting with two corrugations side lap fixed with L-type or J-type or cranked hook bolts in roof, wall etc.complete all as specified and directed |
| 92 | M&L for 25 mm thick PCC 1:2:4, type B-0 using 12.50 mm graded crushed stone aggregates as in floor surfaces, complete all as specified and directed. |
| 93 | M&L for brick work with subclass 'B' bricks, straight or curved on plan exc 6 M mean radius built in CM 1:6 complete all as specified and directed |
| 94 | Material & Labour for providing and fixing stainless steel (Grade 304) railing made of hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (where ever required) and fitting the same with necessarystainless steel nuts and bolts complete, including taking down and fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of floor or the side of waist slab with suitable arrangement complete all as specified and directed. |
| 95 | S&F 10mm plain toughned glass for stair case hand rail covering with complete fittings of SS nut bolts and clamps all as specified and as per manufacturer's instructions. |
| 96 | Excavation in trenches in n.exc 1.5m wide and n.exc 1.5m in depth for foundations etc or for shafts wells, cesspits, manholes, pier holes,n.exc 10 sqm on plan and n.exc 1.5m in depth and getting out in any type of soil. |
| 97 | M&L for cement concrete 1:4:8 type D-2 200 mm thick concrete bed to drain pipe including packing under and haunching against the side of pipes after they are laid and tested, complete all as specified and directed. |
| 98 | S&F 200mm bore/Inner Dia double wall corrugated HDPE pipes (SN8) in any length , laid in trenches or in floors complete all as specified and directed. |
| 99 | Returning, filling in, including spreading, levelling, watering and well ramming in layers n.exc 25 cm thick complete all as specified |
| 100 | Removal of excavated (soil) and bldg material (stone/cement mortar/concrete/etc) and depositing outside the defence premises on desecration of Contractor of any lead, complete all as specified and directed |
| 101 | Demolition and breaking of 200mm dia drain pipes (salt glazed ware, AC or reinforcement concrete) set in cement mortar all as specified and directed. |
| 102 | S&F factory made SFRC manhole / drain cover (Grade M-25) heavy duty cover slab in rectangular shape of size as required, 80 mm thick incl MS sheet 2 mm thick and 80 mm wide all around the cover inclu demolition of old manhole cover slab complete all as spefcified and directed |
| 103 | M&L for brick work with subclass 'B' bricks, straight or curved on plan exc 6 M mean radius built in CM 1:6 complete all as specified and directed |
| 104 | INTERNAL ELECTRIFICATION |
| 105 | Taking down carefully copper/aluminium point wiring light ,fan, light fittings,socket or power complete, such as switches, ceiling roses, pendents, regulators, sockets etc.removing materials to store for keeping in safe costudy or for taking credit (credit for above items should be made as per conditioned separately) and making good disturbed surface of walls, floors etc. complete all as specified and directed by Engineer-in-Charge. Please Enable Macros to View BoQ information |
| 106 | Taking down carefully copper/aluminium point wiring light ,fan, light fittings,socket or power complete, such as switches, ceiling roses, pendents, regulators, sockets etc.removing materials to store for keeping in safe costudy or for taking credit (credit for above items should be made as per conditioned separately) and making good disturbed surface of walls, floors etc. complete all as specified and directed by Engineer-in-Charge. Please Enable Macros to View BoQ information |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |