| 1 | Taking down shutters of any description exc 1.0 Sqm and nexc 2 sqm refixing in same opening complete all as specified and as directed. |
| 2 | Taking down shutters of any description exc 1.0 Sqm and nexc 2 sqm complete all as specified and as directed. |
| 3 | Demolition of cement concrete of any description and in any position not otherwise specifically provided for complete all as specified and as directed. |
| 4 | Demolition of brick work or stone masonry built in cement mortar including all quoins arches, pillar etc but excluding ashlar facing , dressed stone work and precast concrete articles, complete all as specified and as directed. |
| 5 | Material and labour for providing plain cement concrete with Nano filler 1: cement 1; sand 2: agregate 4 type B1 using 20mm graded stone aggregate as in roof padding laid in slope as per requirement mixed with integral water proofing liquid admixture as per manufacturer's instructions complete all as specified and as directed.Note : (i) Minimum thickness of PCC shall be 30mm. (ii) Integral water proofing liquid admixture shall be measured and paid separately under appropriate item here in after(ii) PCC shall be laid to acheive true slope towards the drain/weep holes.1) Material and labour for applying a coat of Nano technology based water proofing compound (1 part powder : 1 part liquid), of desired consistency with nylon brush1 @ 5 sqm/kg coverage over vertical/horizantal surface of RCC roof and parapet complete all as specified and as directed.2) M&L Water Proofing:a) Surface Preparation - Mild Chipping of the surface, Clean the Surface with Nano Bio wash.b) Providing and applying Nano Water Base Water Proof compound one coats after surface preparation using brush, not containing toxic materials like Pb, Cr, Zn; having defect-free nano-particles with inhibiting characteristics having bacteria killing rate above 98% and anti-fungal properties, with super-hydrophobic properties with contact angle of water more than 75degree , permeable type with elongation (stretch ability) of more than 300%, in a nano-structured self assembled dispersion system with VOC level of less than 1% , 60 micron DFT.c) If ant crack found open and fill the crack with nano carbon base nano plymer Plaster d) If online leackage found seal with Nano magic and apply nano Bond coat. Open the cracks by making ‘V’ groove, filling cracks with Nano Crack Filler.e) Aplly Nano carbon baesed shorter chain Nano Bond Coat f) Use nano wall Plymer high stregth filler to reduce the undulation.g) Apply Nano high penetration Bond coat two coat.h) Providing and applying Nano Barrier Coat Paint/ Nano Water Base Water Proof Paints 2 coats over screed concrete using brush, not containing toxic materials like Pb, Cr, Zn; having defect-free nano-particles with inhibiting characteristics having bacteria killing and anti-fungal properties, with super-hydrophobic properties with contact angle of water more than 750 , with elongation (stretch ability) of more than 300%, in a nano-structured self assembled dispersion system with VOC level of less than 1% , 60 micron DFT per coat.(g) The entire item to be executed through certified specialist firm/expert person with warranty of 5 yrs. |
| 6 | M&L for repair to damaged roof after complete removal existing treatment including padding, cleaning. the surface using wire brush brooming down and applying the following treatment all as directed in order of precedence as stated:-(a) Applying one coat of bituminious primer. (Note:- Bituminous primer shall be 'TANK MASTIC' manufactured by M/S STP Ltd or \\"EMUFALTE\\" Manufactured by M/s Texsa India Ltd)(b) Supply and laying 3 mm thick APP based polymeric membrane of approved manufactured with weight not less than 3.00 Kg/Sqm reinforced with non-woven polyester febric weight not less than 150 gms per Sqm. Polymeric membrance shall be taken to a height of 75mm (minimum) and than inserted inside the groove of parapet wall and shall be finished by a membrance flashing. Note:- Laying APP based polymeric membrane shall be done torch on method as per manufacturers instructions. |
| 7 | Taking down cement plaster on brick or stone walls etc including raking out joints, hacking for key, scrubbing down with water etc complete all as specified and as directed. |
| 8 | M&L for 5mm thick plastering in CM with nano filler 1: Cement 1: Sand 3 on concrete surfaces as in sides of column, lintel, beam, chajja, facia railing, RCC, wardrobe etc including finish the surface even and fair without using extra cement complete all as specified and as directed.Note: Nano material shall be measured and paid separately. |
| 9 | M&L for 20mm thick plastering in CM with nano wall filler 1: Cement 1: Sand 4 in two layers, top layer mixed with integral water proofing liquid admixture as per manufacturers instruction on brick or concrete surfaces of wall finished the surface fair and even complete all as specified and as directed.Note: WPC& Nano material shall be measured and paid separately. |
| 10 | M&L for 15mm thick plastering in CM with nano wall filler 1: Cement 1: Sand 6 on fair face of brick or concrete surfaces, finished the surface fair and even and smooth without using extra cement complete all as specified and as directed.Note: Nano material shall be measured and paid separately. |
| 11 | Supply only nanotechnology based elastomeric hydrophobic powder/admixture(EHP) powder for cement plaster and concrete complete all as specified and as directed. |
| 12 | M&L for exposing cracks more than 1mm wide with tile cutter and forming V groves nex 10mm wide and 10mm deep in inside RCC roof and filling nanotechnology based anti-corrosive with higher strength carbon fiber based shorter chain epoxy coating process:a) Clean the surface and open the crack and apply nano base bond coat.b) Mix with nano wall filler with bond coat and fill the crack.c) Apply final bond coat in the cracked surface.Note: 1. Note: Nano material shall be measured and paid separately.2. Rate shall be include for making surface clean, dustfree, dry, and free of wax grease, oil, loose or peeling particle, and other foreign material. |
| 13 | M&L for PCC 1:2:4 Type B0 using 12.5 mm graded aggregate as in levelling course, haunching, coping and similar works of over RCC roof surface including rounded or chamferred on edges etc complete all as specified and as directed. |
| 14 | S&F and applying/laying normal treatment using glass fibre base bitumen felt, grade 2 on roof sheets or roofs complete all as specified and directed. |
| 15 | M&L Water Proofing:a) Surface Preparation - Mild Chipping of the surface, Clean the Surface with Nano Bio wash.b) If onlinr leackage found seal with Nano magic and apply nano Bond coat.Open the cracks by making ‘V’ groove, filling cracks with Nano Crack Filler.c) Aplly Nano carbon baesed shorter chain Nano Bond Coat d) Providing and applying Nano Water Base Water Proof compound one coats after surface preparation using brush, not containing toxic materials like Pb, Cr, Zn; having defect-free nano-particles with inhibiting characteristics having bacteria killing rate above 98% and anti-fungal properties, with super-hydrophobic properties with contact angle of water more than 75degree , permeable type with elongation (stretch ability) of more than 300%, in a nano-structured self assembled dispersion system with VOC level of less than 1% , 60 micron DFT.e) If ant crack found open and fill the crack with nano carbon base filler and bond coat.and use nano wall filler to reduce the undulation.f) Apply Nano high penetration Bond coat two coat.g) Providing and applying Nano Barrier Coat Paint/ Nano Water Base Water Proof Paints 2 coats over screed concrete using brush, not containing toxic materials like Pb, Cr, Zn; having defect-free nano-particles with inhibiting characteristics having bacteria killing and anti-fungal properties, with super-hydrophobic properties with contact angle of water more than 750 , with elongation (stretch ability) of more than 300%, in a nano-structured self assembled dispersion system with VOC level of less than 1% , 60 micron DFT per coat.(h) The entire item to be executed through certified specialist firm/expert person with warranty of 5 yrs. |
| 16 | M & L for PCC (1:5:10) type E2 using 40mm graded stone aggregate in foundations, filling and mass concrete, sunken floors complete all as specified and directed. |
| 17 | Material and labour for appplying NANO magic in sealing floor traps, waste pipes outlets from wall, etc complete all as specified and directed. |
| 18 | Repair to sunken per 1 sqm area including taking down plater/rendering, cleaning, sweeping removing dust and mud, or water, scoring sunken surfaces of bathroom/toilet etc and filling or levelling of roof surface by using concrete (1:2:4, with WPC over 0.90mm polythene sheet) CM 1:3 rendering and neeru finish to plastering as specified and make sure sunken is water proof by ponding of 48hrs. |
| 19 | Taking up or down steel tubing and disconnection, for 15mm bore of pipescomplete all as specified and directed. |
| 20 | Taking up or down steel tubing and disconnection, for 20mm bore of pipes complete all as specified and directed. |
| 21 | Taking up or down steel tubing and disconnection, for 25mm bore of pipes complete all as specified and directed. |
| 22 | Dismantling floor, hearth , wall tiling including cement mortor bedding (but not backing) removing serviceable tiles to store and rubbish off the premises complete all as specified and directed. |
| 23 | Excavation in post holes (or similar holes) each in any type of soil n. exc. 0.5 cum, getting out, returning filling in an ramming earth or broken rubble mixed with earth around, in layers n. exc. 25 cm, watering and removing surplus soil to a distance not exc. 50 M and making good complete all as specified and directed. |
| 24 | M&L plain cement concrete Type C2 1:3: 6 (40mm graded aggregates) in foundations, filling in post of fencing, pcc sub-base and mass concrete complete all as specified and directed. |
| 25 | M&L for PCC (1:4:8) type D2 using 40mm graded stone aggregate as in foundation , filling and mass concrete complete all as specified and directed. |
| 26 | S&F framed work as in doors or gates or tank staging of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing complete Fe.290.Gde-E-165 complete all as specified and directed. |
| 27 | M&L for pre-cast PCC solid block walling with cement concrete type C1 (1:3:6, using 20 mm graded crushed stone aggregrates) exc.10cm in width and setting in cement mortar 1:6, complete including demolition at old precast cement concrete block walling complete all as specified and as directed. |
| 28 | M&L Providing precast cement concrete solid building blocks (C1 1:3:6 using 20mm graded stone aggregates) 10cm thick (with plain or interlocking joints as directed) setting in 1:6 cement mortar, complete, in walls complete all as specified and directed. |
| 29 | S & F Vitreous China EWC with P or S Trap including seat cover closed pattern with flat bottom and cover and MS CP hinging device, PVC flush bend pipe incl PVC Flushing Cistern 10 LITRE capacity, Low Level Valve Less, Symphonic Action type, White, with Inlet, Ball Valve, Float and Handle including 32mm dia PVC Flush Pipe, a Pair of Cast Iron Brackets duly Painted/ Erecting Stand including Cutting and Pinning in Ends, Making Good Disturbed Surfaces in Cement Mortar 1:3 including taking down unserviceable Flushing Cistern and connected Items of any description, complete all as specified and as directed. |
| 30 | S&F vitreous China squatting pan, ‘Orissa’ pattern, size 580 x 440 mm white, with integral foot rests (including flushing cistern and flush pipe) complete all as specified and directed. |
| 31 | S&F in repair PVC valveless, 10 ltrs, syphonic action type, flushing cistern, low level, white, with inlet, ball valve, float and handle including brackets complete all as specified and directed. |
| 32 | S&F in repair Bib tap standard of PTMT any colour high pressure screwed for iron pipe bore dia 15mm and fixed. (Minimum weight 15mm-90gms/20mm-125gms) complete all as specified and directed. |
| 33 | S&F brass CP mixer (sink, wash basin and wall) for mixing hot & cold water screwed down for iron pipe and fixed complete all as specified and directed. |
| 34 | S&F vitreous China clay WHB flat back size 550x400 mm without pedastal but inc PVC waste pipe 32 mm dia, waste coupling brackets etc complete all as specified and directed. |
| 35 | S&F vitreous China clay wash hand basin of size 550x400mm with pedastal incl brackets for fixing complete all as specified and as directed. |
| 36 | M&L for non skid ceremic white tiles 7 to 8mm thk area of each tile exc 0.06 sqm but n exc 0.11 sqm in floor etc set and jointed in neat cement slurry and pointed in white or coloured cement to mortar.Laid over and including15 mm thick cement screed bed in CM 1:6 complete all as specified and directed. |
| 37 | M&L for non skid ceremic white tiles 7 to 8mm thk area of each tile exc 0.11 sqm but n exc 0.18 sqm in floor etc set and jointed in neat cement slurry and pointed in white or coloured cement to mortar.Laid over and including15 mm thick cement screed bed in CM 1:6 complete all as specified and directed. |
| 38 | M&L for non skid ceremic white tiles 7 to 8mm thk area of each tile exc 0.18 sqm but n exc 0.36 sqm in floor etc set and jointed in neat cement slurry and pointed in white or coloured cement to mortar.Laid over and including15 mm thick cement screed bed in CM 1:6 complete all as specified and directed. |
| 39 | M & L Glazed ceramic Coloured Tile 300x450x7mm/300x600x7 mm thick in Skirting, Dados, etc., Set and Jointed in Neat Cement Slurry and Pointed in White or Colour Cement to match laid over a backing coat of 10mm thick CM 1:4 screed, complete all as specified and as directed. |
| 40 | S&F in repairs Brass CP angular stop cock fancy type with Capstan heads complete all as specified and directed. |
| 41 | S&F in 15mm Gun metal, globe or gate vavles, with iron wheel head, screwed both ends for iron pipe complete all as specified and directed. |
| 42 | S&F in 20mm Gun metal, globe or gate vavles, with iron wheel head, screwed both ends for iron pipe complete all as specified and directed. |
| 43 | S&F in repairs Brass chromium plated bottle traps 32 mm dia for wash basins with inlet and outlet screwed for pipe or connections incl necessary packing uniun and cap and fixed in repairs complete all as specified and directed. |
| 44 | S&F in repairs pillar tap 15 mm, chromium plated, fancy type complete all as specified and directed. |
| 45 | M&L for 110 mm PVC (SWR) pipes single socketed in any length with rubber ring joints ,laid in trenches or in floors complete all as specified and directed. |
| 46 | M&L for 75 mm PVC (SWR) pipes single socketed in any length with rubber ring joints ,laid in trenches or in floors complete all as specified and directed. |
| 47 | S&F PVC (SWR) bends 110mm dia complete all as specified and as directed. |
| 48 | S&F PVC (SWR) bends 75mm dia complete all as specified and as directed. |
| 49 | S&F PVC(SWR) 75mm dia vent cowls complete all as specified and directed. |
| 50 | Supply and Laying Steel Water Tubing 15mm dia (Bore), Galvanised, ‘Medium Grade’ with all Fittings, fixed on Walls, Ceiling or laid in Floors or any other Situation, complete as all specified and as directed. |
| 51 | Supply and Laying Steel Water Tubing 20mm dia (Bore), Galvanised, ‘Medium Grade’ with all Fittings, fixed on Walls, Ceiling or laid in Floors or any other Situation, complete as all specified and as directed. |
| 52 | Supply and Laying Steel Water Tubing 25mm dia (Bore), Galvanised, ‘Medium Grade’ with all Fittings, fixed on Walls, Ceiling or laid in Floors or any other Situation, complete as all specified and as directed. |
| 53 | Supplying and laying of 16mm bore CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings in trenches complete all as specified and directed. |
| 54 | S&F cutting chases, pinning in concrete block workmaking good to facing where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades shelves, lintels etc, and cutting chases for concealed water tubing or concealed conduit wiring etc and making good, cutting not exc 10cm girth complete all as specified and directed. |
| 55 | S&F Stack clamps out of 50mm by 5mm flat iron and 16mm dia round iron stays ,incl bolts and nuts and securing ends of stays to wall or roof complete all as specified and directed. |
| 56 | S&F PVC Connections 15mm size with PTMT Nuts of length 450mm and fixed, complete all as specified and as directed. |
| 57 | S&F steel connections 15mm size with CP Nuts of length 450mm and fixed, complete all as specified and as directed. |
| 58 | Supply hoisting and fixing rotational moulded HDPE water storage tank after disconnecting of old tank,double layer ,ISI marked (cylendrical vertical type with closed top) of capacity 1000 ltrs in position incl float valve high pressure of PTMT with epoxy coated aluminium rod & high-density plastic ball screwed for iron pipe and fixed incl dismantling of tank all as specified and directed. |
| 59 | Supply hoisting and fixing rotational moulded HDPE water storage tank after disconnecting of old tank,double layer ,ISI marked (cylendrical vertical type with closed top) of capacity 500 ltrs in position incl float valve high pressure of PTMT with epoxy coated aluminium rod & high-density plastic ball screwed for iron pipe and fixed incl dismantling of tank all as specified and directed. |
| 60 | S&F float valve of size 15mm, high pressure, with polyethylene float and fly nut complete, screwed for iron pipe all as specified and directed |
| 61 | S&F float valve of size 20mm, high pressure, with polyethylene float and fly nut complete, screwed for iron pipe all as specified and directed. |
| 62 | Disconnecting existing tanks setting aside (or lowering if required) for repairs , cleaning and removing all scale and dirt etc from tanks and mouths of circulating pipes etc and hoisting if required reconnecting and refixing in position complete exc 250 and nexc 500 ltrs all as specified, pasting sticker of computer printed pvc sheets of size (200x200mm) writing date of cleaning complete all as specified and directed. |
| 63 | Disconnecting existing tanks setting aside (or lowering if required) for repairs , cleaning and removing all scale and dirt etc from tanks and mouths of circulating pipes etc and hoisting if required reconnecting and refixing in position complete exc 500 and nexc 1000 ltrs all as specified, pasting sticker of computer printed pvc sheets of size (200x200mm) writing date of cleaning complete all as specified and directed. |
| 64 | S&F PVC water tank (exc 250 and nexc 500 ltrs) lids complete all as specified and directed. |
| 65 | S&F PVC water tank (exc 500 and nexc 1000 ltrs) lids complete all as specified and directed. |
| 66 | M&L for 75 mm thick PCC (1:3:6 ) type C -2 as in Plinth protection finished even and smooth without using extra cement complete all as specified and as directed. |
| 67 | S&F Bib taps cast copper alloy with crutch or butterfly handle , screwed down for iron pipe fancy type chromium plated complete all as specified and directed. |
| 68 | S&F Self-closing taps, cast copper alloy, chro-mium plated, screwed for iron pipe 15mm bore and fixed complete all as specified and directed. |
| 69 | M&L 75mm dia PVC(SWR) floor trap, plain with grating including jointing with solvent cement complete all as specified and directed. |
| 70 | M&L for rendering 15m thick on fair faces of brick or concrete work in CM 1:4 finished even and smooth without using extra cement complete and two coat of cement base paint over a coat of alkali resistant primer complete all as specified and directed. |
| 71 | Supply only Integral waterproofing compound complete all as specified and directed. |
| 72 | S&F 600mmx450mm bevelled edge mirror of selected quality glass, mounted on 6mm thick AC building board or commercial plywood and fixed to wooden plugs with chromium plated brass screws and cup washers complete all as specified and as directed. |
| 73 | S&F factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails. M.S. frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of plain colour PVC sheet to be fitted in the M.S. frame welded / sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement, suppling & fixing in the frame at site as per specification & drawing complete all as specified and directed. |
| 74 | S&F solid PVC Door Frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with M.S. Square tube, suppling & fixing in opening as per specification & drawing complete all as specified and directed. |
| 75 | S&F Seat cover for pedestal pan or EWC complete all as specified and directed. |
| 76 | S&F single piece EWC seat cover any type complete all as specified and directed. |
| 77 | S&F WHB and sink waste 32mm bore pipe complete all as specified and directed. |
| 78 | S&F Health faucet (ABS Body) mild steel chromium plated suitable for 15 mm dia pipe with 1.25 metre long flexible tube and ABS wall hook including making connections and fixed in position complete all as specified and directed. |
| 79 | Taking up or down 15mm bore steel tubing including cleaning and removing all scale and dirt etc and connections in new or old position (Walls, ceiling, floors, etc.) complete all as specified and directed. |
| 80 | Taking up or down 20mm bore steel tubing including cleaning and removing all scale and dirt etc and connections in new or old position (Walls, ceiling, floors, etc.) complete all as specified and directed. Please Enable Macros to View BoQ information |