Sales : +91-777 804 8217
| Sl. No. | Item Description |
| 1 | Clearing grass and removal of the rubbish up to a distance of 50 m outside the periphery of the area cleared. (DSR Ch-1 sl 2.32 Page No. -95) |
| 2 | Earth work in excavation by mechanical means (Hydraulic excavator)/manual means in foundation trenches or drain over areas (not exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottom, for all lifts, including getting out the excavated soil and dispose of surplus excavated soil as directed within a lead of 50 m. All kinds of soil as per ( DSR Ch-1 S.No.- 2.8.1, Page No. 91 ) |
| 3 | Diluting and injecting chemical emulsion for POST-CONSTRUCTIONAL anti-termite treatment (excluding the cost of chemical emulsion) Treatment of soil under existing floors using chemical emulsion @ one litre per hole, 300 mm apart including drilling 12 mm diameter holes and plugging with cement mortar 1 :2 (1 cement : 2 Coarse sand) to match the existing floor: With Chlorpyriphos/Lindane E.C. 20 percent with 1 percent concentration as per DSR 2023 S.I. No. 2.35.3 ,Page No. 95 |
| 4 | Excavating, supplying, stacking and filling of local earth (including royalty) by mechanical transport upto a lead of 5km also including ramming and watering of the earth in layers not exceeding 20 cm in foundation trenches, plinth, sides of foundation etc.complete for all lift.(Under Floor) ( DSR S.No.- 2.25 (a), Page No. 94 ) |
| 5 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:4:8 (1 cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources) ( DSR ch-4 S.No.- 4.1.8, Page No. 103 ) |
| 6 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in: Cement mortar 1:6 (1 cement : 6 coarse sand) ( DSR S.No.- 6.1.2, Page No. 127 ) |
| 7 | Providing and laying in position ready mixed or site batched design mixM-25 cement concrete for reinforced cement concrete work, using coarse aggregate and fine aggregate derived from natural sources, cement, admixtures in recommended proportions as per IS: 9103, in all works up to plinth level, including pumping of concrete to site of laying, laying, vibrating, curing etc. complete but excluding the cost of centering, shuttering and reinforcemen all complete as per DSR 2023 item no. 5.33.1.1, Page No. 120 |
| 8 | Providing and laying in position ready mixed or site batched design mix M-25 cement concrete for reinforced cement concrete work, using coarse aggregate and fine aggregate derived from natural sources, cement, admixtures in recommended proportions as per IS: 9103, in all works above plinth level, including pumping of concrete to site of laying, laying, vibrating, curing etc. complete but excluding the cost of centering, shuttering and reinforcemen all complete as per DSR 2023 item no. 5.33.2.1, Page No. 120 |
| 9 | Add for using extra cement in the items of design mix over and above the specified cement content there in as per DSR 2023 Item No. 5.35, Page No. 121 |
| 10 | Steel reinforcement for R.C.C. work ready to use \\" cut and bend\\" rebars of approved make from factory/ wrkshop to construction site including placing in position and binding all complete in Thermo-Mechanically Treated bars of grade Fe-500D or more.( DSR S.No.- 5.22C.1, Page No. 119 ) |
| 11 | Providing and laying damp-proof course 50 mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources).( DSR S.No.- 4.11, Page No. 107 ) |
| 12 | Providing & applying a coat of residual petroleum bitumen of grade of VG-10 of approved quality using 1.7kg per square metre on damp proof course after cleaning the surface with brushes and finally with apiece of cloth lightly soaked in kerosene oil.( DSR S.No.- 4.13, Page No. 107 ) |
| 13 | Providing and fixing angle iron frames for doors , windows and ventilatorsof mild steel angle sections of size 40 x 40 x 5 mm, joints mitred and welded by angle iron 40 x 40 x5 mm or 35 x5 mm flat pieces to the existing T- iron frame or to the wall with dash fastners, including fixing of neccessary butt hinges and screws and applying a priming coat of approved steel primer , all complete as per the direction of Engineer - in - charge ( DSR S.No.- 10.31, Page No. 186 ) |
| 14 | Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters. 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws. ( DSR S.No.- 9.20.1, Page No. 150 ) |
| 15 | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete.Fixed to steel windows by welding ( DSR S.No.- 9.48.1, Page No. 153 ) |
| 16 | Brick work with common burnt clay bricks of M-150 class in super structure above plinth level upto floor V level in all shapes and sizes in proportion Cement mortar 1:6 (1 cement : 6 coarse sand) ( DSR S.No.- 6.4.2, Page No. 127 ) |
| 17 | Two track two panels sliding door with Aluminium channel for roller track, wool pile, zinc alloy (zamak) powder coated handle on every panel along with multi-point locking system, adjustable nylon rollers with SS 304 body.Using R3 series with frame (55mm & above) x (40mm & above) & sash (30mm & above) x (74mm & above). (Height upto 2.5 metre). ( DSR S.No.- 9.147.B1.1, Page No. 171 ) |
| 18 | 15 mm cement plaster of mix : 1:6 (1 cement: 6 coarse sand) ( DSR S.No.- 13.5.2, Page No. 217 ) |
| 19 | 12 mm cement plaster of mix : 1:6 (1 cement: 6 coarse sand) ( DSR S.No.- 13.4.2, Page No. 217) |
| 20 | Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement, including cement slurry, but excluding the cost of nosing of steps etc. complete. 40 mm thick with 20 mm nominal size stone aggregate( DSR S.No.- 11.3.1, Page No. 189) |
| 21 | Providing and fixing 1st quality ceramic glazed floor tiles conforming to IS : 15622 (thickness to be specified by the manufacturer ) of approved make in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge in skirting, risers of steps and dados over 12 mm thick bed of cement Mortar 1:3 (1 cement: 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm including pointing in white cement mixed with pigment of matching shade complete. (DSR S.No.- 11.37A, Page No. 193) |
| 22 | Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. (DSR S.No.- 8.31, Page No. 143) |
| 23 | Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete.Size of Tile 600x600 mm(DSR S.No.- 11.41.2, Page No. 194) |
| 24 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even andsmooth complete. ( DSR S.No.- 13.80, Page No.223 ) |
| 25 | Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gram/litre, of approved manufacturer and of required shade and colour all complete to achieve even shade and colour :New work (two or more coats) over and including water thinnable priming coat with cement primer having VOC content less than 50 gram/litre ( DSR S.No.- 13.41.1, Page No. 220 ) |
| 26 | Finishing walls with Acrylic Smooth exterior paint of required shade :New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/10 sqm.( DSR S.No.- 13.46.1, Page No. 220 ) |
| 27 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade :One or more coats on old work .( DSR S.No.- 13.99, Page No. 224 ) |
| 28 | Centering and shuttering including stutting, propping etc and removal of form in Foundation & Column ( DSR S.No.- 5.9.1 ) |
| 29 | Centering and shuttering including stutting, propping etc and removal of form in Lintel Beam , Plinth Beam & Main beam ( DSR S.No.- 5.9.5 ) |
| 30 | Centering and shuttering including stutting, propping etc and removal of form in Suspended Floor, Roof, Landing etc (DSR S.No. 5.9.3) |
| 31 | Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.).( DSR S.No.- 10.28, Page No. 186 ) |
| 32 | Providing and fixing in position collapsible steel shutters with vertical channels 20x10x2 mm and braced with flat iron diagonals 20x5 mm size, with top and bottom rail of T-iron 40x40x6 mm, with 40 mm dia steel pulleys, complete with bolts, nuts, locking arrangement, stoppers, handles, including applying a priming coat of approved steel primer. ( DSR S.No.- 10.3, Page No. 183 ) |
| 33 | Chequerred precast cement concrete tiles 22 mm thick in footpath & courtyard, jointed with neat cement slurry mixed with pigment to match the shade of tiles, including rubbing and cleaning etc. complete, on 20 mm thick bed of cement mortar 1:4 (1 cement: 4 coarse sand). Light shade pigment using white cement ( DSR S.No.- 11.20.1, Page No. 191) |
| 34 | Providing & fixing false ceiling at all height including providing & fixing of framework made of special section, power pressed from M.S. sheets and galvanised with zinc coating of 120 gms/ sqm (both side inclusive) as per IS : 277 and consisting of angle cleat of size 25mm wide x 1.6mm thick with flanges of 27mm and 37mm, at 1200mm c/c, one flange fixed to the ceiling with dash fastener 12.5mm dia x 50mm long with 6mm dia bolts, other flange of cleat fixed to the angle hangers of 25 x10 x0.50mm of required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate G.I chanels 45 x15 x 0.90mm running at the spacing of 1200 mm c/c, to which the ceiling section 0.5mm thick bottom wedge of 80mm with tapered flanges of 26 mm each having lips of 10.5mm, at 450mm c/c, shall be fixed in a direction perpendicular to G.I intermediate channel with connecting clip made out of 2.64mm dia x 230mm long G.I wire at every junction, including fixing perimeter channels 0.50mm thick 27mm high having flanges of 20mm and 30mm long, the perimeter of ceiling fixed to wall/ partitions with the help of Rawl plugs at 450mm centre, with 25mm long dry wall screws @ 230mm interval, including fixing of Calcium Silicate Board to ceiling section and perimeter channels with the help of dry wall screws of size 3.5 x25mm at 230mm c/c, including jointing & finishing to a flush finish of tapered and square edges of the board with recommended jointing compounds, jointing tapes,finishing with jointing compounds in three layers covering up to 150mm on both sides of joints and two coats of primer suitable for boards, all as per manufacture's specification and also including the cost of making opening for light fittings, grills, diffusers, cut outs made with frame of perimeter channels suitably fixed, all complete as per drawings, specificaton and direction of the Engineer in charge but excluding the cost of painting with: ( DSR S.No.- 12.59.1, Page No. 211) |
| 35 | Laying of 20 mm. Thick Black Granite (Polished) in Big Slab Flooring / Skirting over Previously Prepared Base / Wall with 2 cm. Thick 1:3 Cement and Approved Sand Mortar Including Filling of Joints with Cement Mixed with Pigment Required for Matching the Shade of Floor Including Cutting Polishing with Wax Including supply of all materials, labour, T&P etc. required for proper completion of work ( D.S.R. Code 11.56.1) |
| 36 | Supply and fixing on roof pressed clay tile (Mangalore tile)of 20 mm nominal thickness and of approved size and as per approved pattern etc all complete work as per DSR 2023 item no. 12.48, page no. 207 |
| 37 | Supply and fixing of Sign Board. |
| 38 | Providing and laying integral cement based water proofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces etc consisting of following operations: (a) Applying a slurry coat of neat cement using 2.75 kg/sqm of cement admixed with water proofing compound conforming to IS. 2645 and approved by Engineer-in-charge over the RCC slab including adjoining walls upto 300 mm height including cleaning the surface before treatment. (b) Laying brick bats with mortar using broken bricks/brick bats 25 mm to 115 mm size with 50% of cement mortar 1:5 (1 cement : 5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge over 20 mm thick layer of cement mortar of mix 1:5 (1 cement :5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge to required slope and treating similarly the adjoining walls upto 300 mm height including rounding of junctions of walls and slabs. (c) After two days of proper curing applying a second coat of cement slurry using 2.75 kg/ sqm of cement admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge. (d) Finishing the surface with 20 mm thick jointless cement mortar of mix 1:4 (1 cement :4 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge including laying glass fibre cloth of approved quality in top layer of plaster and finally finishing the surface with trowel with neat cement slurry and making pattern of 300x300 mm square 3 mm deep. (e) The whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing and for final test. “All above operations to be done in order and as directed and specified by the Engineer-in-Charge”: With average thickness of 120 mm and minimum thickness at khurra as 65 mm. as per SI no. -22.7.1 |
| 39 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in: Cement mortar 1:4 (1 cement : 4 coarse sand) ( DSR S.No.- 6.1.1, Page No. 127 ) |
| 40 | 20 mm cement plaster of mix : 1:3 (1 cement: 3 coarse sand) ( DSR S.No.- 13.9.2, Page No. 217 ) |
| 41 | Providing and fixing in position pre-cast R.C.C. manhole cover and frame of required shape and approved quality EHD - 35 Circular shape 560 mm internal dia( DSR S.No.- 19.19.4, Page No. 313) |
| 42 | Making soak pit 2.5 m diameter 3.0 metre deep with 45 x 45 cm dry brick honey comb shaft with bricks and S.W. drain pipe 100 mm diameter, 1.8 m long complete as per standard design. With common burnt clay F.P.S. (non modular) bricks of class designation 7.5( DSR S.No.- 19.32.1, Page No. 316) |
| 43 | Supplying, filling, spreading & leveling coarse sand of size range 1.5 mm to 2 mm in recharge pit, in required thickness over gravel layer,for all leads & lifts, all complete as per direction of Engineer -incharge. (DSR sl 23.7 page 340) |
| 44 | Supplying, filling, spreading & leveling gravels of size range 5 mm to 10 mm, in the recharge pit, over the existing layer of boulders, in required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge. (DSR sl 23.6 page 340) |
| 45 | Supplying, filling, spreading & leveling stone boulders of size range 5 cm to 20 cm, in recharge pit, in the required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge. (DSR sl 23.5 page 339) |
| 46 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources) ( DSR S.No.- 4.1.3, Page No. 103 ) |
| 47 | Cement Concrete in 1:6:12 with Cement,C/Sand 2.20 F.M and 4cm gauge stone ballast in foundation & under floor i/c all etc. complete in all respects as per S.I.No. 281(a)+ new (Rate as per S.O.R.-Rampur Circle) |
| 48 | \\"Providing and laying factory made chamfered edge Cement Concrete paver blocks in footpath, parks, lawns, drive ways or light traffic parking etc, of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over 50mm thick compacted bed of sand, compacting and proper embedding/laying of interlocking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand complete all as per direction of Engineer-in-Charge. 80 mm thick C.C. paver block of M-35 grade with approved color design and pattern\\". as per DSR 2023 item no. 16.91.1 |
| 49 | Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required: White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests ( DSR S.No. 17.1.1, Page No. 265 ) |
| 50 | Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required : W.C. pan with ISI marked white solid plastic seat and lid ( DSR S.No. 17.2.1, Page No. 265 ) |
| 51 | Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350 mm and 340x410x265 mm sizes respectively with automatic flushing cistern with standard flush pipe and C.P. brass spreaders with brass unions and G.I clamps complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required :One urinal basin with 5 litre white P.V.C. automatic flushing cistern ( DSR S.No. 17.4.1, Page No. 265 ) |
| 52 | Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: White Vitreous China Flat back wash basin size 550x 400 mm with single 15 mm C.P. brass pillar tap ( DSR S.No. 17.7.4, Page No. 266 ) |
| 53 | Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete.Semi rigid pipe: 32 mm dia ( DSR S.No. 17.28.1.1, Page No. 269 ) |
| 54 | Providing and fixing 8 mm dia C.P. / S.S. Jet with flexible tube upto 1 metre long with S.S. triangular plate to Eureopean type W.C. of quality and make as approved by Engineer - in - charge.( DSR S.No. 17.16A, Page No. 268) |
| 55 | Providing and fixing on wall face unplasticised-Rigid PVC rain water pipes conforming to IS: 13592 Type A including jointing with seal ring conforming to IS: 5382 leaving 10mm gap for thermal expansion. 110 mm dia ( DSR sl. 12.41.2 Page No 205) |
| 56 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply and all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge.: Internal work - Exposed on wall, 25 mm dia Nominal dia Pipes ( DSR 18.7.3 Page No 281) |
| 57 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge Concealed work, including cutting chases and making good the walls etc. 15 mm dia Nominal dia Pipes (DSR Sl 18.8.1) |
| 58 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge Concealed work, including cutting chases and making good the walls etc. 20 mm dia Nominal dia Pipes (Sl 18.8.2) |
| 59 | Providing and fixing uplasticised PVC connection pipe with brass unions :45 cm length,15 mm nominal bore. ( DSR 18.21.2.1 Page No 283) |
| 60 | Providing and fixing brass stop cock of approved quality :15 mm dia Nominal bore (Sl 18.16.1) |
| 61 | Providing and fixing brass stop cock of approved quality :20 mm dia Nominal bore (Sl 18.16.2) |
| 62 | Providing and fixing C.P. brass bib cock of approved quality conforming to IS:893115 mm dia Nominal bore (Sl 18.49.1) |
| 63 | Providing and fixing C.P. brass long nose bib cock of approved quality conforming to IS standards and weighing not less than 810 gms.15 mm dia Nominal bore (Sl 18.50.1) |
| 64 | Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:893115 mm dia Nominal bore (Sl 18.53.1) |
| 65 | Providing and fixing C.P. brass shower rose with 15 or 20 mm inlet :150 mm dia Nominal (Sl 18.22.2) |
| 66 | Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS:13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required : Kitchen sink with drain board: 510x1040 mm bowl depth 250 mm (Sl 17.10.1.1) |
| 67 | Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. ( DSR S.No. 18.48, Page No. 288 ) |
| 68 | Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. ( DSR S.No. 17.31, Page No. 269 ) |
| 69 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge.( Concealed work, including cutting chases and making good the walls etc.- Exposed on wall) :20 mm nominal dia (Sl 18.8.2) |
| 70 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work : 25 mm nominal dia (Sl 18.9.3) |
| 71 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work : 32 mm nominal dia (Sl 18.9.4) |
| 72 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work : 40 mm nominal dia (Sl 18.9.5) |
| 73 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work :50 mm nominal dia (Sl 18.9.6) |
| 74 | Provide, fixing and testing 25 mm brass ball valve with nuts and bolts as per D.S.R. 2023 item no. 18.18.3 |
| 75 | Providing and fixing gun metal non- return valve of approved quality (screwed end) : 50 mm vertical (Sl 18.19.4.1) |
| 76 | Providing and fixing on wall face unplasticised-Rigid PVC rain water pipes conforming to IS: 13592 Type A including jointing with seal ring conforming to IS: 5382 leaving 10mm gap for thermal expansion: 75 mm dia (Sl 12.41.1) |
| 77 | Providing and fixing on wall face unplasticised-Rigid PVC rain water pipes conforming to IS: 13592 Type A including jointing with seal ring conforming to IS: 5382 leaving 10mm gap for thermal expansion: 110 mm dia (Sl 12.41.1) |
| 78 | Providing and fixing on wall face unplasticised-Rigid PVC rain water pipes conforming to IS: 13592 Type A including jointing with seal ring conforming to IS: 5382 leaving 10mm gap for thermal expansion: Coupler 75 mm dia (Sl 12.42.1.1) |
| 79 | Providing and fixing on wall face unplasticised-Rigid PVC rain water pipes conforming to IS: 13592 Type A including jointing with seal ring conforming to IS: 5382 leaving 10mm gap for thermal expansion: Coupler 110 mm dia (Sl 12.42.1.2) |
| 80 | Providing and fixing on wall face unplasticised-Rigid PVC rain water pipes conforming to IS: 13592 Type A including jointing with seal ring conforming to IS: 5382 leaving 10mm gap for thermal expansion: Single tee with door 75 x 75 x 75 mm (Sl 12.42.3.1) |
| 81 | Providing and fixing on wall face unplasticised-Rigid PVC rain water pipes conforming to IS: 13592 Type A including jointing with seal ring conforming to IS: 5382 leaving 10mm gap for thermal expansion: Single tee with door 110 x 110 x 110 mm (Sl 12.42.3.2) |
| 82 | Providing and fixing on wall face unplasticised-Rigid PVC rain water pipes conforming to IS: 13592 Type A including jointing with seal ring conforming to IS: 5382 leaving 10mm gap for thermal expansion: Single tee without door75 x 75 x 75 mm (Sl 12.42.4.1) |
| 83 | Providing and fixing on wall face unplasticised-Rigid PVC rain water pipes conforming to IS: 13592 Type A including jointing with seal ring conforming to IS: 5382 leaving 10mm gap for thermal expansion: Single tee without door 110 x 110 x 110 mm (Sl 12.42.4.2) |
| 84 | Providing and fixing on wall face unplasticised-Rigid PVC rain water pipes conforming to IS: 13592 Type A including jointing with seal ring conforming to IS: 5382 leaving 10mm gap for thermal expansion: Bend 87.5° 75 mm dia (Sl 12.42.5.1) |
| 85 | Providing and fixing on wall face unplasticised-Rigid PVC rain water pipes conforming to IS: 13592 Type A including jointing with seal ring conforming to IS: 5382 leaving 10mm gap for thermal expansion: Bend 87.5° 110 mm dia (Sl 12.42.5.2) |
| 86 | Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with M.S. screws of required length, including cutting brick work and fixing in cement mortar 1:4 (1 cement :4coarse sand) and making good the wall etc. complete : 75 mm dia (Sl 12.43.1) |
| 87 | Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with M.S. screws of required length, including cutting brick work and fixing in cement mortar 1:4 (1 cement :4coarse sand) and making good the wall etc. complete : 110 mm dia (Sl 12.43.2) |
| 88 | Boring 150 dia bore hole i/c labour T&P etc required for proper completion of the work. |
| 89 | Lowerng 110 mm dia mm PVC pipe in bore hole i/c labour , T&P etc required for proper completion of the work. |
| 90 | Providing and fixing 110 mm dia PVC pipe 6 kg/cm2 |
| 91 | Sorrounding and packing graded coarse sand in between bore wall & the strainer i/c supply of coarse sand , labour , T&P etc. required for proper completion of work. |
| 92 | Providing and fixing G.I. pipes 32 mm dia nominal bore complete with G.I. fiting. |
| 93 | Submersible pump kirlosker/crompton or equivalent 2.0 H.P. I.S.I. marked. |
| 94 | Single phase starter for submersible of ISI marked. |
| 95 | 2.5 mm sq. mm cable for submersible motor pump. |
| 96 | 4 Inch dia M.S. clamp made with 32X5 mm flate iron with nut and bolt. |
| 97 | 100 mm dia and P.V.C. end cap. |
| 98 | Solution for joining P.V.C. pipe 250 gm. |
| 99 | 32 mm C.P.V.C. Pipe. |
| 100 | Developing of bore well by over pumping and back washing till the discahrge is free from turbidity not greater then 20. p.p.m after 20 minutes of starting of pump i/c hiring cahrges of pump set, labour, T&P etc. require for proper completion of work. |
| 101 | Nylon cloth for strainer i/c plastic rope/cutting holes in pvc pipe etc complete. |
| 102 | Excavating trenches in all kind of soil of required width for pipes, cables etc. including excavation for sockets and dressing of sides, ramming of bottoms, depth upto 1.5 m. including getting out the excavated soil & then returning the soil as required in layers not exceeding 20 cm in depth including consolidating each deposited layer by ramming, watering, etc & disposing of surplus excavated soil as directed with in alead of 50 cm. (DSR S.No. 2.10.1.2 page 92) (a) Pipes 80mm to 300mm diameter. |
| 103 | Providing & laying cement concrete 1:5:10 (1 cement : 5 coarse sand :10 graded stoneaggregate 40mm nominal size) alround PVC pipes including bed concrete as per standard design.(DSR S.No. 19.2.2 page 309) (b)150mm diameter PVC Pipe. |
| 104 | Constructing brick massonary manhole with 75 class designation F.P.S.bricks in cement mortar 1:4 (1 cement : 4 coarse stand) R.C.C top slab with 1:2:4 mix (1 cement : 2 coarse sand : 4 grade stone aggregate 20mm nominal size) foundation concrete 1:4:8 mix (1 cement: 4 coarse sand : 8 grade stone aggregate 40mm nominal size) inside plastering 12mm thick with cement mortar 1:3 (1 cement : 3 coarse sand )finished with a floating coat of neat cement and making channels in cement concrete 1:2:4 (1 cement: 2coarse : 4 grade stone aggregate 20mm nominal size) neat cement complete as per standard design.Inside size 90x80 cm and 45 cm deep including C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover and frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg) :With common burnt clayF.P.S. (non modular) (DSR SNo. 19.7.1.1 page 310) |
| 105 | Earth work in excavation by mechanical means (Hydraulic excavator)/manual means in foundation trenches or drain over areas (not exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottom, for all lifts, including getting out the excavated soil and dispose of surplus excavated soil as directed within a lead of 50 m. All kinds of soil as per ( DSR Ch-1 S.No.- 2.8.1, Page No. 91 ) Upto 1.50 mt |
| 106 | Earth work in excavation by mechanical means (Hydraulic excavator)/manual means in foundation trenches or drain over areas (not exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottom, for all lifts, including getting out the excavated soil and dispose of surplus excavated soil as directed within a lead of 50 m. All kinds of soil as per ( DSR Ch-1 S.No.- 2.8.1+2.1.1, Page No. 91 ) above 1.50 mt Up to 3.00 mt depth |
| 107 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:5:10 (1 cement : 5 coarse sand (zone-III) derived from natural sources : 10 graded stone aggregate 40 mm nominal size derived from natural sources) ( DSR S.No.- 4.1.10, Page No. 103 ) |
| 108 | Boring/drilling bore well of required dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/ bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer-in- charge, upto 90 metre depth below ground level: 300 mm size nominal dia (DSR sl 23.1.1.1 page 339) |
| 109 | Supplying, assembling, lowering and fixing in vertical position in bore well unplasticized PVC medium well screen (RMS) pipes with ribs, conforming to IS: 12818, including hire & labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer-in-charge: 100 mm size nominal dia (DSR sl 23.4.1 page 339) |
| 110 | Wiring point for light/ Fan Point/ Exhaust Fan point / call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor Single core cable in surface / Recessed medium class PVC conduit , with piano type switch , phenolic laminated sheet suitable size MS box and earthing the point with 1.5 sqmm FRLS PVC insulated copper conductor single core cable etc . as per required Group A ( E&M 2025 DSR No 1.8.1, Page no. 3) |
| 111 | Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, 2 way modular switch, modular plate, suitable Gl box and earthing the point with 1.5 sq.mm FRLS PVC Insulated copper conductor single core cable etc. as required. ( E&M 2025 DSR No 1.11, Page no. 3) |
| 112 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cale in surface/ recessed medium class PVC conduit as required: 2 X 1.5 sq. mm + 1 x 1.5 sq. mm earth wire (Item no. 1.14.1) |
| 113 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cale in surface/ recessed medium class PVC conduit as required: 2 X 2.5 sq. mm + 1 x 2.5 sq. mm earth wire (Item No. 1.14.2) |
| 114 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cale in surface/ recessed medium class PVC conduit as required: 2 X 4.0 sq. mm + 1 x 4.0 sq. mm earth wire (Item No. 1.14.3) |
| 115 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cale in surface/ recessed medium class PVC conduit as required: 2 X 6.0 sq. mm + 1 x 6.0 sq. mm earth wire (Item No. 1.14.4) |
| 116 | Supply and fixing following Modular Switch / socket on the existing switch box / cover in cluding connection etc as required : 5/6 amps Switch (Item no. 1.24.1) |
| 117 | Supply and fixing following Modular Switch / socket on the existing switch box / cover in cluding connection etc as required : 2 way 5/6 amps Switch (Item No. 1.24.2) |
| 118 | Supply and fixing following Modular Switch / socket on the existing switch box / cover in cluding connection etc as required : 15/16 amps Switch (Item No. 1.24.3) |
| 119 | Supply and fixing following Modular Switch / socket on the existing switch box / cover in cluding connection etc as required : 3 pin 5/6 amps Socket outlet (Item No. 1.24.4) |
| 120 | Supply and fixing following Modular Switch / socket on the existing switch box / cover in cluding connection etc as required : 6 pin 15/16 amps Socket outlet (Item No. 1.24.5) |
| 121 | Supply and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc as per required . (E&M 2025 DSR No 1.25, Page no 9) |
| 122 | Supply and fixing following size / module base & cover plate for modular switches in recess etc as required: 3 Module (100 mm x 75 mm) (Item No. 1.27.2) |
| 123 | Supply and fixing following size / module base & cover plate for modular switches in recess etc as required: 6 Module (200 mm x 75 mm) (Item No. 1.27.4) |
| 124 | Supply and fixing following size / module base & cover plate for modular switches in recess etc as required: 8 Module (125 mm x 125 mm) (Item No. 1.27.5) |
| 125 | Supply and fixing following size / module base & cover plate for modular switches in recess etc as required: 12 Module (200 mm x 150 mm) (Item No. 1.27.6) |
| 126 | Supply and fixing following modular base & cover plate on existing modular metal box etc as required: 3 Module (Item No. 1.28.2) |
| 127 | Supply and fixing following modular base & cover plate on existing modular metal box etc as required: |
| 128 | Supply and fixing following modular base & cover plate on existing modular metal box etc as required: 8 Module (Item No. 1.28.5) |
| 129 | Supply and fixing following modular base & cover plate on existing modular metal box etc as required: 12 Module (Item No. 1.28.6) |
| 130 | Supplying & fixing suitable size Gi box wih modular plate and cover in front on surface or in recess including providing and fixing 25 A modular socket outlet and 25 A modular SP. MCB, \\"C\\" curve including connections, painting etc. as required. ( E&M 2025 DSR No 1.57, Page no. 13) |
| 131 | Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, 6 way (4+18), Double door (TPN) MCB distribution board, 415 V, on surface/recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, Interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/isolator) ( E&M 2025 DSR No 2.4.2, Page no. 15)6 way (4+18), Double door (TPN) |
| 132 | Supplying and fixing 5A to 32A rating, 240/415V , 10kA \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections , testing and commissioning etc as per required : Single pole (E&M 2025 DSR No 2.10.1, Page no 16) |
| 133 | Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required. (E&M 2025 DSR No 2.11, Page no 16) |
| 134 | Supplying and fixing following rating, 4 pole, (3 phase and neutral), 415 volts, residual current circuit breaker (RCCB)41 A, having a sensitivity current upto 30 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required. (E&M 2025 DSR No 2.15.2, Page no 17) |
| 135 | Installation, testing and conunissioning of prewired, flourescent Being/ compact fluorescent fitting of all types, complete with all accessories and tubes etc. directly on celling/wall, including connection with 1.5 sq mm. PVC insulated, copper conductor, single core cable etc. as required installation of exhaust fan in the existing opening, including making good the damage,(E&M 2025 DSR No 1.41, Page no 11) |
| 136 | Installation of exhaust fan in the existing opening, including making good the damage,connections, testing, commissioning etc. as required upto 450 mm sweep. (E&M 2025 DSR No 1.50.1, Page no 12) |
| 137 | Extra for fising the louvers/shutters complete with frame for exhaust fans of all size (E&M 2025 DSR No 1.51, Page no 12) |
| 138 | Supply, Installation, Testing and Commissioning of 1200 men sweep, BETS star rated, ceiling fan with Brush Less Direct Current (BLDC) Motos, class of insulation: 8, 3 nos, blades, 30 cm long down rod, 2 nom. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CM/M/W) minimum 600, Air delivery minanum 210 Cum/Min, 150 RPM (tolerance as per 15 374-2019), THO less than 10% remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature me-75 degree C (max.), Insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz. single phase AC Supply, earthing etc. complete as required. (E&M 2025 DSR No 9.1.3, Page no 64) |
| 139 | LED Batten light (System lumen efficacy ≥105 <120 lm/Watt)Supplying, installation, Testing & Commissioning of LED surfacemounted Batten light of following body material etc all complete as per E/M D.S.R. 2025 item No. 8.9.4 ,Page No. 47 |
| 140 | LED Down lighter 22 Watt (SMD Type) (System lumen efficacy ≥ 105 <120lm/Watt)Supplying, installation, Testing & Commissioning of LEDRecessed / surface Down lighter (Round/ square/ Rectangular)SMD type of following body material etc. all complete as per E/M D.S.R. 2025 item no. 8.1.5, Page No. 38 |
| 141 | Supply Installation Testing and Commissioning of 2 MP IP IRDome Camera with 25/30fps@1080P (1920×1080)) IP IR Dome Camera etc all complete .(E&M 2025 DSR No. 40.1.1, Page no 279 |
| 142 | Supplying Installation Testing and Commissioning of 2MPFixed Lens IP IR Outdoor Bullet Camera with 2MP @ 25/30fps@1080P (1920×1080) Outdoor Bullet Camerawith 2.8/ 3.6mm fixed lens (E&M 2025 DSR No. 40.2.1, Page no 280 |
| 143 | Supplying Installation Testing and Commissioning of followingChannel Network Video Recorder (NVR) with camera licensesto record for all channels having spcifications with 08 Channel Network Video Recorder (NVR) having display split:- Main screen: 1/4/8/9, 2nd screen: 1/4/8/9 (E&M 2025 DSR No. 40.10.1, Page no 296) |
| 144 | Supplying, Installation, Testing and Commissioning followingcapacity Serveillance grade Hard Disk with upto 256MB/sTransfer Rate, 256 MB Cache, 7200 RPM Disk Speed, 3.5 inchform factor, SATA Interface, BSMI, ICES-003/NNB-003, CE,FCC, KC, Maghreb, RCM, UKCA, VCCI, CB-Scheme, TUV, ULCertifications.40.12.1 4TB (Terabytes) (E&M 2025 DSR No. 40.12.1, Page no 299) |
| 145 | Supplying, Installation, Testing and Commissioning of followingsize LED display (LED monitor) industrial grade with3840x2160 resolution or better, USB playback, bluetooth andmiracast connectivity, 4X HDMI 2.0, DP 1.2, HDR 10/10+,brightness: 500-nits or better, Video wall mode should beavailable, contrast ratio: 1200:1, OPS slot, viewing angle (H/V):170°/ 170°, response time less than 12ms, Display control shallbe on monitor screen and programmable with remote (remoteshall be supplied with system), Key Board, Optical Mouse, etc.as required.42.4.1 32 inch or larger (E&M 2025 DSR No. 42.4.1, Page no 303) |
| 146 | S/Laying of aluminum conductor PVC insulated armoured served sheathed cables 1100 volts grade at a depth of 750 mm below ground level over a cushion of 75 mm. thick sand all around and protected with burnts bricks on sides and on top. On surface the cable run shall be fixed on M.S. clamps etc of suiabtle size or as directed by the Engineer-incharge , complete in all respects. the armouring of the cable shall be properly connected with the earth conductor bu clamps etc. all complete. (E/M SOR 2018 irem No. 501) - (k) 3.5CX 35 Sqmm Armoured Al. Cable |
| 147 | S/Laying of aluminum conductor PVC insulated armoured served sheathed cables 1100 volts grade at a depth of 750 mm below ground level over a cushion of 75 mm. thick sand all around and protected with burnts bricks on sides and on top. On surface the cable run shall be fixed on M.S. clamps etc of suiabtle size or as directed by the Engineer-incharge , complete in all respects. the armouring of the cable shall be properly connected with the earth conductor bu clamps etc. all complete. (E/M SOR 2018 irem No. 501) -(i) 4.0C X 16 Sqmm Armoured Al. Cable |
| 148 | S/Laying of aluminum conductor PVC insulated armoured served sheathed cables 1100 volts grade at a depth of 750 mm below ground level over a cushion of 75 mm. thick sand all around and protected with burnts bricks on sides and on top. On surface the cable run shall be fixed on M.S. clamps etc of suiabtle size or as directed by the Engineer-incharge , complete in all respects. the armouring of the cable shall be properly connected with the earth conductor bu clamps etc. all complete. (E/M SOR 2018 irem No. 501) -(h) 4.0C X 10 Sqmm Armoured Al. Cable |
| 149 | S/Laying of aluminum conductor PVC insulated armoured served sheathed cables 1100 volts grade at a depth of 750 mm below ground level over a cushion of 75 mm. thick sand all around and protected with burnts bricks on sides and on top. On surface the cable run shall be fixed on M.S. clamps etc of suiabtle size or as directed by the Engineer-incharge , complete in all respects. the armouring of the cable shall be properly connected with the earth conductor bu clamps etc. all complete. (E/M SOR 2018 irem No. 501) -(f) 4.OCX 4 Sqmm Armoured Al. Cable (EXTERNAL LIGHTING) |
| 150 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required. UPTO 35 sqmm (E&M 2025 DSR No 10.1.1, Page no 66) |
| 151 | Supplying and making end termination with brass compression glandlagid aluminium lugs for following size of PVC insulated and PVC sheathed/XLPE aluminium conductor cable of 1.1 KV 45 grade as required: 4 X 10 sq. mm (25 mm) (Item No. 11.1.32) |
| 152 | Supplying and making end termination with brass compression glandlagid aluminium lugs for following size of PVC insulated and PVC sheathed/XLPE aluminium conductor cable of 1.1 KV 45 grade as required: 4 X 16 sq. mm (28 mm) (Item No. 11.1.33) |
| 153 | Supplying and making end termination with brass compression glandlagid aluminium lugs for following size of PVC insulated and PVC sheathed/XLPE aluminium conductor cable of 1.1 KV 45 grade as required: 3.5 X 35 sq. mm (32 mm) (Item no. 11.1.21) |
| 154 | Earthing with Gi earth pipe, 4.5mtr long, 40mm dia including accessories and providing masonary enclosure with cover plate having locking arrangement etc. (with charcoal and salt) as required. (E&M 2025 DSR No 5.2, Page no 34) |
| 155 | Supplying and laying 6 SWG G.I. wire at 0.50 metre below ground level for conductor earth electrode, including connection/termination with Gi thimble etc. as required (E&M 2025 DSR No. 5.7 Page No. 34) |
| 156 | Supplying and laying 25 mm x 5 mm G.1 strip at 0.50 metre below ground as strip earth electrode, including connection/terminating with G.1. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of Gl. nut bolt & spring washer spaced at 50mm)(E&M 2025 DSR No. 5.9 Page No. 35) |
| 157 | Providing and fixing 25 mm. X5 mm G.I. strip on surface or in recess for connection etc as required. (E&M 2025 DSR No. 5.15 Page No. 35) |
| 158 | Providing and faing 6 SWG dia G.. wire on surface or in recess for loop earthing as required. (E&M 2025 DSR No. 5.16 Page No. 35) |
| 159 | Providing and fising of lightning conductor finial, made of 25 mm dia 1200 mm long, copper tube, having single prong at top, with 15 mmm dia 3 mm thick copper base plate including holes with insulation etc. complete as required (E&M 2025 DSR No. 6.2 Page No. 36) |
| 160 | Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or on surface of wall for lightning conductor complete as required. (For Vertical run) (E&M 2025 DSR No. 6.8 Page No. 36) |
| 161 | Providing and fixing testing joint, made of 20 mm X 3 mm thick G.1. strip, 125 mm long, with 4 nos. of G.1. bolts, nuts, chucknnuts and spring washers etc. complete as required. (E&M 2025 DSR No. 6.12 Page No. 36) |
| 162 | Supply, installation, Testing & Commissioning of ‘Silent Type25 KVA Diesel Generating set as per CPCB IV + or better norms alongwith having Prime Power Rating of KVA as below, 415 volts at1500 RPM, 0.8 lagging power factor at 415 V suitable for 50 Hz,3 phase system & for 0.85 Load Factor, including testing atfactory and site with fuel, load for test and other necessaryarrangements Complete as per CPWD specifications, shouldhave QR code which should contain drawing, test report OEMmanual,Geo- Tag of manufacturing location, rating plate as perrelevant IS Code etc. ( E/M 2025 DSR item No. 29.1.1),Page no. 214 |
| 163 | Supply , Installation, Testing and Comissioning of Air Cooled HiWall split type Air conditioners Ratingcomplete with Indoor unit(IDU),Out door unit (ODU), surface / concealed copper Refrigerantpiping with insulation (closed cell elastomeric nitrile rubbertubular pipe section) upto 3 Mtr (IDU to ODU), copper powercable upto 3.5 Mtr (IDU to ODU) i/c drain pipe R-32/R-410/ R-407 Green Refrigerant, wireless Remote control, suitable forworking between 180-260V with low & high voltage cutoff and50 hz ,1 phase AC supply capable of performing cooling,dehumidification, air circulation of following capacity with Scroll /rotary compressor. The system shall be able to deliver 100% ofthe rated capacity upto 42 Degree Celcius. Min 5 year OriginalEquipment Manufacturer (OEM) warranty both compressor and Printed Circuit Board (PCB). Must comply : Electrical cable IS694 or IS 9968 temperature sensing control IS /InternationalElectrotechnical Commission (IEC) 60730, hermetic compressorIS 10617, heat exchanger IS 11329, capacitor IS 2993 andmotor IS 12615. Complete as per CPWD specification and IS :1391 Part II 2023. The system shall be able to operate up to 500C (out door ambient temperature).Inverter Type : 2.0 TR with 5 Star BEE Rating (E&M 2025 DSR Item No. 32.2.4), Page No. 241 |
| 164 | Supply , Installation, Testing and Comissioning of Air Cooled HiWall split type Air conditioners Ratingcomplete with Indoor unit(IDU),Out door unit (ODU), surface / concealed copper Refrigerantpiping with insulation (closed cell elastomeric nitrile rubbertubular pipe section) upto 3 Mtr (IDU to ODU), copper powercable upto 3.5 Mtr (IDU to ODU) i/c drain pipe R-32/R-410/ R-407 Green Refrigerant, wireless Remote control, suitable forworking between 180-260V with low & high voltage cutoff and50 hz ,1 phase AC supply capable of performing cooling,dehumidification, air circulation of following capacity with Scroll /rotary compressor. The system shall be able to deliver 100% ofthe rated capacity upto 42 Degree Celcius. Min 5 year OriginalEquipment Manufacturer (OEM) warranty both compressor and Printed Circuit Board (PCB). Must comply : Electrical cable IS694 or IS 9968 temperature sensing control IS /InternationalElectrotechnical Commission (IEC) 60730, hermetic compressorIS 10617, heat exchanger IS 11329, capacitor IS 2993 andmotor IS 12615. Complete as per CPWD specification and IS :1391 Part II 2023. The system shall be able to operate up to 500C (out door ambient temperature).Inverter Type : 1.50 TR with 5 Star BEE Rating (E&M 2025 DSR Item No. 32.2.3), page no. 241 |
| 165 | S/F of the Fire Extinguisher, ABC Type 6.00 Kg. capacity ( ISI MARKED IS : 15683 & TAC Approved ) complete with initial charge and wall Bracket, Along with supply of all Materials and Labour for Proper Completion of Work. PWD SOR 2018 SI NO. 1131 |
| 166 | Suply and fixing of fire extinguisher, CO2 type 4.5 kg capacity (ISI marked IS 2878 & TAC approved (complete with initial charge and wall bracket along with supply of all materials and labour for proper completion of work ) PWD SOR 2018 SI NO. 1132 |
| 167 | S/F of Fire Bucket, Round Bottom made of G.I. Sheet 9-11 Liters capacity duly Painted as per Fire Brigade Design, supported on Hanging Bracket Chained and Locked, initially filled with Fine River Sand, Water as per Directions of Engineer-In-Charge etc. PWD SOR 2018 SI NO. 1133 Please Enable Macros to View BoQ information |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail