| 1 | Sub Head - I (Conduit laying)Supplying and fixing of following sizes of steel conduit along with accessories in surface/recess including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required 20 mm(DSR 2025 - Item no.1.20.1) |
| 2 | 25 mm(DSR 2025 - Item no.1.20.2) |
| 3 | Sub Head - II (Wiring)Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire (DSR 2025 - Item no.1.14.2) |
| 4 | Supplying and drawing of following sizes of FRLS PVC insulated copper conductor ISI marked single core cable in the existing surface/recessed steel/PVC conduit as required. 3 X 1.5 sq mm (DSR 2025 - Item no.1.17.3) |
| 5 | 6 X 1.5 sq mm (DSR 2025 - Item no.1.17.6) |
| 6 | 3 X 2.5 sq mm (DSR 2025 Item no.1.17.12) |
| 7 | 3 X 4 sq mm (DSR 2025 - Item no.1.17.21) |
| 8 | Sub Head - III (Switch Gear)Supplying and fixing metal box of following sizes (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including painting etc. as required. 100 mm X 100 mm X 60 mm deep (DSR 2025 - Item no.1.22.2) |
| 9 | 250 mm X 300 mm X 60 mm deep (DSR 2025 - Item no.1.22.15) |
| 10 | Supplying and fixing following piano type switch/ socket on the existing switch box/ cover including connections etc. as required. 3 pin 5/6 A socket outlet (DSR 2025 - Item no.1.23.4) |
| 11 | Supplying and fixing metal box of 180mm X 100mm X 60mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 6 pin 5/6 & 15/16 A socket outlet and 15/16 A piano type switch, connections, painting etc. as required. (DSR 2025 - Item no.1.30) |
| 12 | Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 6 way , Double door (DSR 2025 - Item 2.3.1) |
| 13 | Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole (DSR 2025 - Item no.2.10.1) |
| 14 | Single pole and neutral (DSR 2025 - Item no.2.10.2) Please Enable Macros to View BoQ information |