Name of Work:- Remaining False Ceiling and Other Work in Seventh Floor at Court Complex Building at Jodhpur Metropolitan, Jodhpur
Sl. No.
Item Description
1
Providing and fixing Granite stone slab mirror polished and machine edge cut in Walls, Pillars, Steps, Shelves, Sills, Counters. Floors etc. laid on 12mm (Av.) thick base of cement mortar 1:3 jointing with white cement mortar 1:2 (1 white cement: 2 marble dust) with pigment to match the shade of the marble slab complete including grinding, rubbing and polishing of IS 3316-1974 :Jhunjhunu / Jalore (Red / Choclate Colour)Size 1501 to 3600 Cm2
2
Providing and fixing Granite stone slab mirror polished and machine edge cut in Walls, Pillars, Steps, Shelves, Sills, Counters. Floors etc. laid on 12mm (Av.) thick base of cement mortar 1:3 jointing with white cement mortar 1:2 (1 white cement: 2 marble dust) with pigment to match the shade of the marble slab complete including grinding, rubbing and polishing of IS 3316-1974 :Jhunjhunu / Jalore (Red / Choclate Colour)Above 3601 Cm2 Slab
3
Extra for providing edge moulding to 18 mm thick marble stone counters, vantities etc. over item No. 7.1 & 7.2 including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-Charge.Granite work. Please Enable Macros to View BoQ information
4
Providing & fixing 12 mm thick Bevelled edge Micro looking Glass Fibre Reinforced Gypsum False ceiling tiles (Diamond or equivalent) of size 595 x 595 mm in true horizontal level suspended on inter locking metal grid of hot dipped galvanised steel sections GRID.The tile shall be laid on Silhouette profile grid system with 15 mm white/black flanges incorporating a 6 mm central reveal in white/black colour and with a web height of 45mm and a load carrying capacity of minimum 15.68 Kgs/Sqm minimum pull out strength of 100 kgs. Silhouette, Main Runners & Cross Tees to have mitred ends & \\"birdsmouth\\" notches to provide mitred cruciform junctions. The T Sections have a Galvanizing of 90 grams per sqm and need to be installed with suspension system of make. The Tile & Grid system used together should carry a 30 year warranty. INSTALLATION :- To comprise main runner spaced at 1200 mm centres securely fixed to the structural soffit using suspension system (Specifications below) at 1200mm maximum centre. The First/Last suspension system at the end of each main runner should not be greater than 450 mm from the adjacent wall. Flush fitting 1200 mm long cross tees to be interlocked between main runners at 600 mm centre to form 1200 x 600 mm module. Cut cross tees longer 600 mm module to be formed by fitting 600 mm long flush fitting cross tees centrally between the 1200 mm cross tees. Perimeter trim to be wall angles of size 3000 x 19 x 19mm, secured to walls at 450 mm maximum centers. SUSPENSION SYSTEM consisting of galvanised M6 dash,8mm outer dia Anchor Fasteners 50mm long with Vertical Hangers rod of galvanised MS 6mm dia fully threaded upto 1000mm long and made of Galvanised MS L-type level adjuster of size 85x25x25x2mm with a minimum pull strength of 110 kg. All complete at all heights as per specifications, drawings and as directed by Engineer-in-Charge.
We takes all possible care for accurate & authentic tender information, however Users
are requested to refer Original source of Tender Notice / Tender Document published by
Tender Issuing Agency before taking any call regarding this tender.