| 1 | Taking down roof trusses, coupled rafters or trussed beams of clear span upto 4m including for renewal of any defective members (timber renewed to be measured separately) and reassembling complete all as specified and directed. |
| 2 | Taking down roof trusses, coupled rafters or trussed beams of clear span above 4m and upto 8m including for renewal of any defective members (timber renewed to be measured separately) and reassembling complete all as specified and directed. |
| 3 | Dismantling wrought iron or mild steel work of any description complete all as specified and directed. |
| 4 | Dismantling timber scantlings 40 sq. cm and over in section, unframed, in any position at roofs complete all as directed by Engr-in-Charge. |
| 5 | S&F Roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc complete conforming to FE 410 W( Gde-E-250) quality A all as specified and directed. |
| 6 | Dismantling of steel sheeting (corrugated, semicorrugated, etc.) sheets in roof coverings incl ridges hips valleys complete all as specified and directed. |
| 7 | M & L for pre-painted hot-dip aluminium-zinc alloy metallic coated of any profile steel sheet corresponding to IS 15965:2012 of durability class 3, atmospheric classification category 3, coating class AZ150, 0.50 mm thick, of an approved colour and having yield strength of 550 MPa as in roof covering fixed with self tapping screws as specified up to anyheight including all necessary scaffolding and safety measures complete all as specified and directed. |
| 8 | M & L for pre-painted hot-dip aluminium-zinc alloy metallic coated plain steel sheet as per IS 15965:2012 of durability class 3, atmospheric classification category 3, coating class AZ150, 0.50 mm thick, of an approved colour and having yield strength of 550 MPa as in ridge/ valley/ gutter fixed with self tapping screws as specified any height Mtr height including all necessary scaffolding and safety measures complete all as specified and directed. |
| 9 | S&F wind ties for roof including securing bolts, flat iron fillets(for securing weather boarding with screw bolts and nuts) including all necessary drilling or riveting etc and similar work conforming to Fe 410-O or Fe-310-O including painted with one soap coat of zinc cromate primer paint (including preparation of surfaces at contractor's workshop before fabrication) complete all as specified and directed. |
| 10 | Dismantling wall and ceiling board of any descrition complete all as specified and directed. |
| 11 | S & F Hangers 6 mm dia. G.I. (upto 1200mm length) adjusting level fixed to roof slabs by means of ceilling cleats made out of G.I. flat 40 x 3 mm size 60mm long complete all as specified and directed. |
| 12 | S & F Anodised powder coated aluminium snap grid frame work for false ceiling ( size of grid 605x605 mm ) complete all as specified and directed. |
| 13 | S & F Non asbestos fibre cement designer building boards 6 mm thick fixed or laid/ inserted to timber/GI/Aluminium framework with screws in ceiling complete all as specified. |
| 14 | Demolition of cement concrete (un reinforced) in ground floors and paving n.exc 15cm thickness (below or above ground (level) and lowering if necessary, removal of the rubbish off the premises all as specified and directed. |
| 15 | Demolition of brick work built in CM including all quions, arches, pillars etc, but excluding ashlar facings, dressed stonework and precast concrete articles including removal of the rubbish off the premises all as specified and directed. |
| 16 | M&L brick work with fly ash ‘ B’ bricks straight or curved on plan exc 6 m mean radius build in CM 1:6 all as specified as directed. |
| 17 | Taking down cement plaster of any description on concrete surfaces such as soffit of RCC slab, chajjas, ceiling and brick walls etc incl raking out joints, hecking for key scrubbing down with water and removal of rubbish off the premises complete all as specified and directed. |
| 18 | M&L for Rendering 10mm thick in CM 1:6 on fair faces of brick work or concrete surfaces of wall finsihed fair and even complete all as specified and directed. |
| 19 | M&L for Rendering 15 mm thick cement plaster in CM 1:4 on fair faces of brick/concrete surfaces finished fair and even, mixed wth water proofing compound admixture (if directed) as per manufacturer's instruction, complete all as specified and directed.Note :- WPC will measuered and paid separatly under relevant item of schedule. |
| 20 | S & F chicken wire mesh for plaster at junctions with brick wall,cutting the grooves in wall , embedding 20 mm dia iron nut bolts across the wall ,plastering 15mm thick in CM 1:3 and finally to match the surface with adjacent surfaces by applying white wash/OBD or cement base paint as applicable complete all as specified and directed by Engineer in Charge. |
| 21 | M & L for crack portion with jacketting technique, taking down the existing plaster up to the brick wall surface of min 200mm wide, cleaning the loose particles on surface of brick work along the length of the crack and filling the gap/crack area with PCC 1:1.5:3 type A0 using 12.5mm aggregate up to brick surface and inserting the welded mesh of size 25X25X2mm along the crack on both sides of the wall surface fixed with, drilling holes 10mm dia on either side of the crack by means of drilling mechanism through the full width of the wall @25cm c/c and insert 8/10mm dia rod in the drilled holes, welded with horizontal rod to with-hold the welded mesh and applying grit plaster 1:1:2 using 4mm and down aggregate finished even and smooth without using extra cement. Note: reinforcement and welded mesh will be measured and paid separately. |
| 22 | M & L for PCC 1:3:6 type C2 using 40mm graded stone aggregate as in walls or retaining walls, any thickness, size or shape including plaster, buttresses, columns, pillars, boundary pillars and posts ( including cap and bases) including necessary formwork complete all as specified and directed by Engr-in-Charge. |
| 23 | Material & Labour for preparation of new surfaces of plastered walls and applying Two coats of Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gms/litre, of approved manufacturer, of required shade and colour complete, as per manufacturer's specification. over and including a coat of primer and 1.0 mm thick white wall care putty (premium quality) over plastered surfaces of walls to prepare the surface even and smooth complete all as specified and directed. |
| 24 | Material & Labour for preparation of new surfaces of plastered walls and applying Two coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm ) over plastered surfaces of walls to prepare the surface even and smooth complete all as specified and directed. |
| 25 | Supply only Liquid water proofing compound complete all as specified and directed. |
| 26 | M&L for preparing of new steel & iron surfaces of any description, not otherwise described, over 10cm width or girth and applying two coats of synthetic enameled paint over a coat of Red oxide zinc chrome primer zinc chrome complete all as specified and as directed. |
| 27 | M&L for RCC 1:1.5:3 type A1 (20 mm graded crushed stone aggregate) nominal mix in beams, cantilevers, bressummers, lintels over1.5 m span complete all as specified and directed. |
| 28 | S&F Mild Steel TMT bars 10mm and over, cut to lenghth, bent to shape requird, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.90mm dia or securing with clip all as directed by Engineer in Charge. |
| 29 | Use and waste form work to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including sup- ports, overhangs, etc. also splays between floors and beams, at flat surfaces etc. complete all as specified & directed by Engineer in Charge. |
| 30 | Dismantling floor hearth or wall tiling including cement mortar bedding (but not backing) removing to low lying area and rubbish off the premises complete all as specified and directed. |
| 31 | M&L for 25mm thick Cement concrete type B- 1, 1:2:4 (using 20mm graded stone aggregate) as in floors, finished even and fair complete all as specified and directed. |
| 32 | M&L Non Skid coloured ceramic tiles 10 mm thick (Square/rectangular) area of each tile exceeding 0.42 sqm but not exceeding 1.00 sqm in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cemeent to match and including over screed bed or bedding layer of mortar 15 mm thick laying floor finished in CM 1:6 complete all as specified and directed. |
| 33 | M&L for Glazed ceramic tiles in vertical surface 350x 250x 7 mm thick set and jointed in neat cement slurry over back coat of layer of 10 mm thick with cement mortar 1:4 and pointed in white or colour cement to match the colour of tiles complete all as speciified and directed. |
| 34 | M&L for 18-20mm thick Granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window-cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to matchwith shade of granite complete all as specified and directed. |
| 35 | Taking up or down 15mm dia bore steel/UPVC tubing and connection including cleaning for refixing or remove to store complete all as specified and directed. |
| 36 | S&F 16 mm outer dia medium grade CPVC, SDR 11 & plain CPVC SDR 11 with all fittings (brass inside the fittings) and fixed complete to walls and ceiling or laid in floors complete all as specified and directed. |
| 37 | Taking up or down 20 mm dia bore steel/UPVC tubing and connection including cleaning for refixing or remove to store complete all as specified and directed. |
| 38 | S&F 20 mm outer dia medium grade CPVC, SDR 11 & plain CPVC SDR 11 with all fittings (brass inside the fittings) and fixed complete to walls and ceiling or laid in floors complete all as specified and directed. |
| 39 | S&F in repair bib taps of 15mm bore fancy type, chromium plated cast copper alloy, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for brass ferrule complete all as specified and directed. |
| 40 | S&F in repair 15 mm bore stop valve cast copper alloy screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe of for unions complete all as specified and directed. |
| 41 | S&F in repair PVC connection 15 mm size PTMT nuts of length length 600 mm complete all as specified and directed |
| 42 | Supply & fix vitreous china wash basin, white, flat back, size, 550X400mm including bracket for fixing 32 mm waste coupling, waste pipe etc complete all as specified and directed. |
| 43 | S&F in repairs Pillar taps, 15mm bore, fancy type cast copper alloy, with capstan heads, chromium plated, screwed down high pressure, with or without lettered 'HOT or COLD' with long screwed shanks and fly-nuts, screwed for iron pipe or for connection pipe complete all as specified and directed. |
| 44 | S&F Harrison rails, anodised alluminium body, chromium plated with fixing brackets, stops, rollers etc complete all as specified and directed. |
| 45 | S&F in repair 32 mm bore Waste coupling of PTMT (half or full threaded) suitable for urinal . (Minimum weight 32mm45gms/40mm-60 gms complete all as specified and directed. |
| 46 | S&F in repair 600mmx450mm bevelled edge mirror of selected quality glass, mounted on 6mm thick AC building board or commercial plywood and fixed to wooden plugs with chromium plated brass screws and cup washers complete all as specified and directed. |
| 47 | S&F in repairs CP tubular towel rail 20mm dia D type 60cm between two flanges complete all as specified and directed by Engineer -in-Charge. |
| 48 | Taking down chowkhat or frame with shutters n.exe 1.50 Sqm (without taking of shutter from frame) each complete all as specified and directed. |
| 49 | Taking down chowkhat or frame with shutters exe 1.50 Sqm and not 4 sqm (without taking of shutter from frame) each complete all as specified and directed. |
| 50 | S&F for factory made single extruded WPC (Wood Polymer Composite) solid door/window/ceosetory windows and other frames/chowkhat of size 50x100 mm comprising of virgin PVC polymer of K value 58-60 (suspension grade ), calcium carbonate and natural fibers (wood powder/rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS scews having minimum frame density of 750 kg/cum, screw withdrawal strength of 2200N (face) and 1100N (Edge), minimum compressive strength of 58 N/mm2 and resistance to spread of flame of class A category with property of being termite /borer proof, water/moisture proof and fire retardant and fixed in position with MS hold fast/lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-in -Charge. (M.S. hold fast/lugs or SS dash fasteners shall be paid for separately) Note :- For WPC solid door/window frames, minus 5mm tolerance in dimension i.e depth and width of profile shall be acceptable. Variation in profile demension on plus side shall be acceptable but no extra payment on this account shall be made. |
| 51 | S&F for factory made single extruded WPC (Wood Polymer Composite) solid door/window/ceosetory windows and other frames/chowkhat of size 50x125 mm comprising of virgin PVC polymer of K value 58-60 (suspension grade ), calcium carbonate and natural fibers (wood powder/rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS scews having minimum frame density of 750 kg/cum, screw withdrawal strength of 2200N (face) and 1100N (Edge), minimum compressive strength of 58 N/mm2 and resistance to spread of flame of class A category with property of being termite /borer proof, water/moisture proof and fire retardant and fixed in position with MS hold fast/lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-in -Charge. (M.S. hold fast/lugs or SS dash fasteners shall be paid for separately) Note :- For WPC solid door/window frames, minus 5mm tolerance in dimension i.e depth and width of profile shall be acceptable. Variation in profile demension on plus side shall be acceptable but no extra payment on this account shall be made. |
| 52 | S&F for factory made single extruded WPC (wood polymer composite) solid plain flush door shutter of 30mm size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum frame density of 650 kg/cum, screw withdrawal strength of 1800N (face) and 900N (Edge), minimum compressive strength of 50 N/mm2, modulus of elasticity 850N/mm2 and resistance to spread of flame of class A category with property of being termite /borer proof, water/moisture proof and fire retardant and fixing with stainless steel butt hings of required size with necessary full body threaded star headed counter sunk S.S screws , all as per direction of Engineer-in -Charge. Note :- Stainless steel butt hinges and necessary SS Screws shall be paid separately) |
| 53 | S&F for 35mm thick factory made single extruded WPC (wood polymer composite) solid wire gauzed i.e. panel will be of wire gauze in lieu of panel. The comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum frame density of 650 kg/cum, screw withdrawal strength of 1800N (face) and 900N (Edge), minimum compressive strength of 50 N/mm2, modulus of elasticity 850N/mm2 and resistance to spread of flame of class A category with property of being termite /borer proof, water/moisture proof and fire retardant and fixing with stainless steel butt hings of required size with necessary full body threaded star headed counter sunk S.S screws , all as per direction of Engineer-in -Charge. Note :- Stainless steel butt hinges and necessary SS Screws shall be paid separately) |
| 54 | S&F 18/19 mm thick, lead free PVC board Superior quality of density not less than 0.55 g/cm3 as in moduler shutters/cabimet drawer cupboard cabinet shutter including all frame work as specified and directed by Engr-in-Charge |
| 55 | S & F Continuous (piano) hinges,width of flaps 40mm stainless steel, bright finish or electro galvanised complete all as specified and directed. |
| 56 | Supply and fixing factory made uPVC white colour Three track three panels sliding window with fly proof S.S wire mesh (Two nos. glazed & one no. wire mesh panels) upto 1.50m height made of (big series) frame 122 x 54 mm & sash 47 x 64 mm both having wall thickness of 2.3 ± 0.2 mm and single glazing bead / double glazing bead of appropriate dimension. (Area of window above 1.75 sqm) comprising of uPVC multichambered frame, with inbuilt roller track and sash extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), appropriate dimension of uPVC extruded glazing beads and uPVC extruded interlocks, EPDM gasket, wool pile, zinc alloy (white powder coated) touch locks with hook, zinc alloy body with single nylon rollers (weight bearing capacity to be 40 kg), G.I fasteners 100 x 8 mm size for fixing frame to finished wall and necessary stainless steel screws etc. Profile of frame & sash shall be mitred cut and fusion welded at all corners, including drilling of holes for fixing hardware's and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealent over backer rod of required size and of approved quality, complete all as specified and directed by Engineer-in-Charge. (Glass or wiremesh shall be paid separately). Note: For uPVC frame and sash extruded profiles minus 5% tolerance in dimension i.e. in depth & width of profile shall be acceptable. Variation in profile dimension in higher side shall be accepted but no extra payment on this account shall be made. |
| 57 | M&L sheet glass 4.8 mm thick ordinary quality and glazing with oil putty and pin in square n. exc 0.50 sqm in each pan complete as directed. |
| 58 | S&F butt hinges 100mm, medium weight, stainless steel all as specified and directed complete all as specified and directed. |
| 59 | S&F butt hinges 75mm size medium weight mild steel cold rolled complete all as specified and directed. |
| 60 | S&F mild steel ordinary rat tail rod pattern spring 300mm including roller and roller plate on wooden/steel choukhat including welding, riveting etc complete all as specified and directed by Engr-in-Charge. |
| 61 | S&F 150 mm aluminium handle cast type, anodised, complete all as specified and directed |
| 62 | S&F150 mm long aluminium anodised barrel tower bolt of extruded section and fixed complete all as specified and directed. |
| 63 | S&F 300 mm Aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixed complete all as specified and directed. |
| 64 | S&F stainless steel wire cloth of 0.36 mm nominal dia of wire and averaging of width of aperture 1.40mm, fixed with stainless steel wire staples complete all as specified and directed. |
| 65 | M&L for framed work such as grills etc with ends of bars shouldered and or riveted or forged into spike, framed guard bars and similar work conforming to Fe 290 Gde-E-165 complete all as specified and directed. |
| 66 | S&F for Powder coated aluminium (minimum thickness of powder coating 50 micron) work for doors, windows, ventilators and partitions (Fixed portions) with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasketetc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including Aluminium snap beading for glazing/ paneling, all complete as per architectural drawings and the directions of Engineer-in-Charge. |
| 67 | S&F for Providing and fixing Powder coated aluminium (minimum thickness of powder coating 50 micron) for shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber/neoprene gasket required (Fittings shall be paid for separately) with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/paneling, C.P. brass/ stainless steel screws all complete as per architectural drawings and the directions of Engineer-in-Charge. |
| 68 | M&L for 4mm thick glass selected quality & glazing with glazing clip & neoprene packing exc 0.50 Sqm in each pane complete all as specified and directed by Engr-In-Charge . |
| 69 | S&F in repairs, door closer aluminium body, hydraulically regulated, designation No.2, universal type, suitable for door shutters and weight between 36 to 60 kg and fixed complete all as specified and directed. |
| 70 | S&F in repair 110mm bore PVC (SWR) bends any radius with access door complete all as specified and as directed by EIC. |
| 71 | S&F in repairs 110mm bore PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors complete all as specified and as directed by Engineer-in-Charge. |
| 72 | M&L for cement concrete type C-1, 1:3:6 (using 20 mm graded stone aggregate) in sub base of floors etc complete all as specified and directed. |
| 73 | M&L for 100mm thick PCC type D2, 1:4:8 using 40mm graded aggregate in foundations, filling and mass concrete complete all as specified and directed. |
| 74 | M&L for Sand filling under floors or in foundations including watering and consolidation complete all as specified and directed. |
| 75 | M&L for Machine pressed precast concrete interlocking paver block any shape and size confirming to IS 15658-2006 of 60 mm thickness M-35 Grade with grey cement and pigment complete as specified. |
| 76 | M&L for 75 mm thick cement concrete M10 (Nominal Mix) with 40mm graded crushed aggregate finished even and fair laid to a slope of 1 in 12, laid in alternate bays, each bay not exceeding 3 m length with joint filled with bituminous mastic filling comprising a mixture of 1 part of heated Industrial bitumen 85/25 grade and two parts of heated sand as in plinth protection complete all as specified |
| 77 | Taking down carefully aluminium conductor point wiring (light,fan,socket or power) complete including fittings such as switches,ceiling roses, pendants, regulators ,sockets etc. and removing (except those to be reused shall be kept in safe custody at the site ) and making good disturbed surfaces of walls, floors etc.to match with the existing complete all as specified. Please Enable Macros to View BoQ information |
| 78 | Taking down carefully aluminium conductor point wiring (light,fan,socket or power) complete including fittings such as switches,ceiling roses, pendants, regulators ,sockets etc. and removing (except those to be reused shall be kept in safe custody at the site ) and making good disturbed surfaces of walls, floors etc.to match with the existing complete all as specified. Please Enable Macros to View BoQ information |