| 1 | Earth work in excavation in all kinds of soil (excluding soil containing 50% or more of shingle or small size boulders upto 30 cm size, saturated soil and rock) including banking in 20 cm layers and breaking clods, ramming and dressing up for the purpose of making embankments or filling up ground depressions, lead upto 50 m and lift upto 1.50 m. |
| 2 | Clearing and Grubbing Road Land . (Clearing and grubbing road land including uprooting rank vegetation, grass, bushes, shrubs, saplings and trees girth up to 300 mm, removal of stumps of trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned up to a lead of 1000 metres including removal and disposal of top organic soil not exceeding 150 mm in thickness.), a) In an area of light jungle |
| 3 | b) In a area of thorny jungle |
| 4 | Earth work in excavation in foundation and trenches etc. in all kinds of soil (excluding soil containing 50% or more of shingle or small size boulders upto 30 cm size, saturated soil and rock), lift upto 1.50 m and stacking the excavated soil not more than 3 m clear from the edge of the excavation and returning the stacked soil in 15 cm layers, when required, into plinth sides of foundation etc consolidating each deposited layer by ramming and watering and then disposing of all surplus soil as directed within a lead of 50m. |
| 5 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. |
| 6 | Filling in plinth with sand under floors including watering, ramming, consolidating and dressing complete. |
| 7 | Cementconcreteflooring1:2:4(1cement :2coarsesand:4gradedstoneaggregate 20 mm nominal size) finished with a floating coat of neat cement. b) 50 mm thick |
| 8 | Extra for marble stone flooring in treads of steps and risers using single length up to 2.00 metre. |
| 9 | Providing and laying cement concrete 1 : 2 : 4 (1 cement : 2 coarse sand : 4 graded stone aggregate 40 mm nominal size) excluding the cost of centring and shuttering in : a) Foundations and plinth |
| 10 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : (a) 1:1½:3 (1 Cement: 1½ coarse sand derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 11 | Reinforced cement concrete in walls (any thickness) including attached pillasters, buttresses, plinth and string course, fillets etc from top of foundation up to floor two level including finishing and plastering the exposed surfaces with cement mortar 1 : 3 (1 cement : 3 fine sand) of thickness not exceeding 6 mm to give a smooth and even surface excluding cost of centring, shuttering and reinforcement in : a) M20 (1 cement : 1.5 corase sand : 3 stone aggregate 20 mm nominal size) |
| 12 | Reinforced cement concrete in suspended floors, roofs, landings and balconies upto floor two level including finishing and plastering the exposed surface with cement mortar 1 : 3 (1 cement : 3 fine sand) of thickness not exceeding 6 mm to give a smooth and even surface but excluding cost of centring and shuttering and reinforcement with M20 (1 cement : 1.5 coarse sand : 3 stone aggregate 20 mm nominal size). |
| 13 | Centring and shuttering including strutting, propping etc and removal of form work for : a) Foundation, footings, bases of columns etc. and mass concrete.RCC , Foundation , Footing |
| 14 | Centring and shuttering including strutting, propping etc and removal of form work for d) Lintels, beams, girders, bressumers and cantilevers etc. |
| 15 | Centering and shuttering including strutting, propping etc. and removal of form for : Suspended floors, roofs, landings, balconies and access platform |
| 16 | Extraforbrickworkwithbestavailablelocalbricks insuperstructureaboveplinthlevel up to floor two level. |
| 17 | 12 mm cement plaster 1 : 6 (1 cement : 6 fine sand). |
| 18 | Painting two or more coats with synthetic enamel paint of approved brand and manufacture in black or chocolate shade on new work over and including an under coat of suitable shade with ordinary paint of approved quality to give an even shade. |
| 19 | Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) : : 21.1.1 For fixed portion :21.1.1.1 Anodised aluminium (anodised transparentor dyed to required shade according to IS: 1868, Minimum anodic coating of gradeAC 15) |
| 20 | Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge. (Cost of aluminium snap beading shall be paid in basic item):With float glass panes of 5.50 mm thickness |
| 21 | ProvidingandfixingMSgrillsof requiredpatterninwoodenframesofwindowsetcwith MS flat, square or round bars with round headed bolts and nuts or by screws. a) Plain grill. |
| 22 | Supplyingandfixingrollingshuttersofapprovedmake,madeof80x1.25mmMSlaths interlocked together through theirentire lengthand jointed togetherat theendbyend locks mounted on specially designed pipe shaft with brackets, side guides and arrangements for insideandoutside lockingwithpushandpulloperationcompletebut excluding the cost of the top cover and spring. |
| 23 | Providing and fixing hand rail of approved size by welding etc. to steel ladder railing, balcony railing, staircase railing and similar works, including applying priming coat of approved steel primer. a) M.S. tube |
| 24 | Providing and fixing 44 mm thick best available local wood Class- B I (19 mm batten and 25 mm bracing) battened and braced doors and windows shutters including providing and fixing necessary bright finished or black enamelled T-hinges, butt hinges, sliding door bolts, tower bolts and handles with necessary bolts and nuts and screws complete. |
| 25 | Providingandfixingchromiumplatedbright finished100mmmorticelatchandlockwith 6 leversandapairofCPhandleswithnecessaryscrewsetccomplete(bestmakeof approved quality). |
| 26 | Steel work in built up tubular trusses including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer welded and bolted including special shaped washers etc complete (welding to be paid separately). |
| 27 | Providing corrugated G.S. sheet roofing including vertical / curved surface fixed with polymer coated J or L hooks, bolts and nuts 8 mm diameter with bitumen and G.I. limpet washers or with G.I. limpet washers filled with white lead, including a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete (up to any pitch in horizontal/ vertical or curved surfaces), excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required.1.00 mm thick with zinc coating not less than 275 gm/m2 |
| 28 | SH:SEEDS/LIVESTOCK, Gir |
| 29 | Sahiwal |
| 30 | Rathi |
| 31 | Kankrej |
| 32 | bull calf |
| 33 | heifer calf |
| 34 | SH:Machinery, Hand-Operated Milking Machine |
| 35 | Single Bucket Electric Milking Machine (0.5 HP) |
| 36 | Double Bucket Milking Machine with 5.5 HP |
| 37 | 60 LPH Hand-Operated Milk Cream Separator |
| 38 | 60 LPH Electric Milk Cream Separator |
| 39 | Hand-Operated Chaff Cutter |
| 40 | Chaff Cutter with 1 HP Motor |
| 41 | Shaktiman TMR Wagon |
| 42 | Cow Brush |
| 43 | Calf Puller |
| 44 | SUB-HEAD-(WIRING) Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed steel conduit, with piano type switch, phenolic laminated sheet, suitable size MS box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required (Light Points) Group A |
| 45 | Group B |
| 46 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed steel conduit, with piano type switch, phenolic laminated sheet, suitable size MS box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required, (Fan points) Group B |
| 47 | Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed steel conduit alongwith 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required. |
| 48 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required, 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire |
| 49 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required., 2 X 6 sq. mm + 1 X 6 sq. mm earth wire |
| 50 | Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required., 2 x 1.5 sq. mm |
| 51 | 2 x 6 sq. mm |
| 52 | Supplying and fixing metal box of 150mm X 75mm X 60mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 3 pin 5/6 A socket outlet and 5/6 A piano type switch, connections, painting etc. as required. |
| 53 | Supplying and fixing metal box of 180mm X 100mm X 60mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 6 pin 5/6 & 15/16 A socket outlet and 15/16 A piano type switch, connections, painting etc. as required. |
| 54 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required., 15/16 A switch |
| 55 | Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. |
| 56 | SUB-HEAD-II (FITTINGS & ACCESSORIES), Supply and fixing circular/ hexagonal M.S. sheet ceiling fan box with clamp of internal dia 140mm, 73 mm height, 3mm thick rim top lid of 1.5mm thick M.S sheet lidss shall be screwed into M.S. box by means of 3mm round headed screws, clamps shall be made of 12 mm dia M.S bar bent to be shape as per standard drawing with over all length as 80 cm |
| 57 | Installation, testing and commissioning of pre-wired, fluorescent fitting / compact fluorescent fitting of all types, complete with all accessories and tube/lamp etc. directly on ceiling/ wall, including connections with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required. |
| 58 | Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable, including providing and fixing phenolic laminated sheet cover on the fan box etc. as required. |
| 59 | Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required, Upto 450 mm sweep |
| 60 | Extra for fixing the louvers/ shutters complete with frame for a exhaust fan of all sizes. |
| 61 | Supplying and fixing 3 pin, 5 A ceiling rose on the existing junction box/ wooden block including connections etc. as required |
| 62 | Supplying and fixing PVC batten/ angle holder including connections etc. as required |
| 63 | Supplying and fixing call bell/ buzzer suitable for single phase, 230 V, complete as required. |
| 64 | Installation ,Testing, Commissioning of wall bracket /ceiling fittings of all sizes and shapes containing upto two GLS/CFL/LED lamps per fitting, complete with all accessories including connections etc. as required. |
| 65 | SUPPLY OF FANS & LIGHT FIXTURES, Supply and of following type fluorescent/CFL fixtures shall be complete with Electronic Ballast, PF improvement capacitor, Control gear box. Bipin Rotor type lamp holder, starter, starter base, all pre wired upto the terminal block. All fixtures shall be supplied with lamps.(make Philips or equivalent/Wipro/Thron). 1 x 18 W FTL, Wall mounted type indoor light fixture |
| 66 | Supplying and of 1200 mm sweep ceiling fan with 300/600 mm standard down rod and electrical connection as required etc. |
| 67 | Supply of heavy duty type exhaust fans of following size sweep with gravity louvers shutters including all accessories/installation materials required make HAVELS/USHA., 450 mm sweep 900 rpm |
| 68 | Providing and supplying of Cashing bit of size 50mm thick |
| 69 | SUB-HEAD-III (DB's AND MAIN SWITCH), Providing and fixing following capacity TP&N disconnector fuse switch unit inside the existing panel board with ISI marked HRC fuses including drilling holes in cubicle panel, making connections, etc. as required. |
| 70 | Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator). 6 way , Double door |
| 71 | supplying and fixing 5A to 32 A rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker, Single pole and neutral |
| 72 | Supplying and fixing following rating, double pole, 240 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. 40 A |
| 73 | SUB-HEAD-IV (EARTHING), Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. |
| 74 | Supplying and laying 25 mm X 5 mm copper strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of brass nut bolt & spring washer spaced at 50mm) |
| 75 | Providing and fixing 4.00 mm dia copper wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable as required. |
| 76 | LIGHTENING PROTECTION,, Providing and fixing of lightning conductor finial, made of 25 mm dia 300 mm long, G.I. tube, having single prong at top, with 85 mm dia 6 mm thick G.I. base plate including holes etc. complete as required. |
| 77 | Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or surface of wall for lightning conductor complete as required.(For horizontal run) |
| 78 | Providing and fixing GI-tape 20 mm x 3 mm thick on parapet or surface of wall for lightning conductor as required.(for vertical run) |
| 79 | Providing and fixing testing joint, made of 20 mm x 3 mm thick gi strip, 125 mm long with 4 Nos. brass bolts, nuts check nuts and spring washers etc. complete as required. |
| 80 | Providing and laying GI tape, 32 mm x 6 mm thick from earth electrode directly in ground as required. |
| 81 | BUBASR BOX-WALL MOUNTED as described above |
| 82 | Meter Box Connection |
| 83 | SH:Water Tank , Providing and laying in foundations and plinth cement concrete 1 : 4 : 8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size) excluding the cost of centring and shuttering. |
| 84 | Reinforced concrete work in foundations, footings, bases of columns etc. and mass concrete excluding cost of centring, shuttering and reinforcement in : b) M20 (1 cement : 1.5 coarse sand : 3 stone aggregate 20 mm nominal size). |
| 85 | Reinforced cement concrete in suspended floors, roofs, landings and balconies upto floor two level including finishing and plastering the exposed surface with cement mortar 1 : 3 (1 cement : 3 fine sand) of thickness not exceeding 6 mm to give a smooth and even surface but excluding cost of centring and shuttering and reinforcement with 1 : 1.5 : 3 (1 cement : 1.5 coarse sand : 3 stone aggregate 20 mm nominal size). |
| 86 | Reinforced cement concrete in retaining wall (any thickness) including attached pillasters, buttresses, plinth and string courses, fillets etc from top of foundation up to floor two level excluding cost of centring,shuttering and reinforcement in :a) M20 (1 cement: 1.5 Coarse Sand : 3 stone aggregate 20 mm nominal size). |
| 87 | Centring and shuttering including strutting, propping etc and removal of form work for :, a) Foundation, footings, bases of columns etc. and mass concrete. |
| 88 | b) Walls (any thickness) including attached pilasters, buttresses, plinth and string courses etc |
| 89 | c) Suspended floors, roofs, landings shelves and their supports, balconies and chajjas (3.5 m height). |
| 90 | Reinforcement of RCC work including straightening, cutting, bending, placing in position and binding all complete., a) Tar/TMT steel |
| 91 | 12 mm cement plaster 1 : 4 (1 cement : 4 fine sand). |
| 92 | 15 mm cement plaster 1 : 3(1 cement : 4 fine sand) on the rough side of single or half brick wall |
| 93 | Distempering with dry distemper of approved brand and manufacture (two or more coats) and of required shade on new work including priming coat of whiting to give an even shade |
| 94 | Supplying and laying under layer of bitumen saturated felt type-I. |
| 95 | Providing and laying four courses water proofing treatment with bitumen felt over roofs consisting of first and third courses of blown or/and residual bitumen applied hot @ 1.45 Kg. per Sq.m. of area for each courses, second course of roofing felt type-3 grade-I (hessian base self finished bitumen felt) and fourth and final course of stone grit 6 mm and down size or pea size gravel spread at 6 Cu.dm. per sqm. including preparation of surface excluding grading complete. |
| 96 | Providing and Placing in position suitable PVC water stops conforming to IS:12200 for construction/ expansion joints between two RCC members and fixed to the reinforcement with binding wire before pouring concrete etc. complete : Serrated with central bulb ( 225mm wide, 8-11mm thick). |
| 97 | Supplying & Fixing CI Covers for manholes w/o frames, 560 mm dia (Heavy Duty), the weight of the cover to be not less then 108 kg. Please Enable Macros to View BoQ information |