| 1 | Earth work in excavation in foundation trenches in ordinary soil ( vide classification of soil item A) and disposal of excavated earth as obtained to a distance upto 50M including all lifts leveling ramming the foundation treanches, removing roots of trees, and shrubs all complete as per approved design, building specification and direction of E/I. |
| 2 | Providing coarse clean sand in filling in foundation trenches or in plinth including ramming and watering in layers not exceeding 150mm thick with all leads and lifts including cost of all materials, labour, royalty and taxes all complete as per building specification and direction of E/I. (Mode of measurement compacted volume). |
| 3 | Providing designation 75A one brick flat soling joints filled with local sand including cost of watering taxes royalty all complete as per building specification and direction of E/I. |
| 4 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinthlevel : 1:1½:3 (1 Cement: 1½ coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 5 | Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level. 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III): 3 graded stone aggregate 20 mm nominal size) |
| 6 | Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement : 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mmnominal size) |
| 7 | Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement, with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size). |
| 8 | Centering and shuttering including strutting, propping etc. and removal of form for Lintels, beams, plinth beams, girders, bressumers and cantilevers |
| 9 | Centering and shuttering including strutting, propping etc. and removal of form for Columns, Pillars, Piers, Abutments, Posts and Struts |
| 10 | Providing Tor steel reinforcement of 8mm. dia rods as per approved design and drawing -do- -do- TMT Fe 500 (Only valid for SAIL & TATA Steel, JSPL, and Vizag Steel) |
| 11 | Providing Tor steel reinforcement of 10mm,12mm & 16 mm dia bars as per approved design and drawing -do- -do 10 mm (TMT coil Fe 500) (Only valid for SAIL & TATA Steel, JSPL, and Vizag Steel) |
| 12 | Providing Tor steel reinforcement of 10mm,12mm & 16 mm dia bars as per approved design and drawing -do- -do 12mm (TMT coil Fe 500) (only valid for Tata (Tiscon), SAIL, JSPL,Electrosteel Steels Ltd. Bokaro and Vizag (RINL)}) |
| 13 | Providing Tor steel reinforcement of 10mm,12mm & 16 mm dia bars as per approved design and drawing -do- -do 16mm (TMT coil Fe 500) (only valid for Tata (Tiscon), SAIL, JSPL,Electrosteel Steels Ltd. Bokaro and Vizag (RINL)}) |
| 14 | Providing designation 100 A brick work with fly ash lime brick (FLAG) confirming to IS 12894-1990 (9\\"x4.5\\"x3\\") in C.M. (1:6) in foundation and plinth with approved uality of clean coarse sand of F.M. 2 to 2.5 including providing 10mm thick mortar joints, cost of screening materials, raking out joints to 15mm depth, curing, taxes and royalty all complete as per building specification and direction of E/I. |
| 15 | Providing designation 100 A brick work with fly ash lime brick (FLAG) confirming to IS 12894-1990 (9\\"x4.5\\"x3\\") in C.M. (1:6) in superstructure and plinth with approved uality of clean coarse sand of F.M. 2 to 2.5 including providing 10mm thick mortar joints, cost of screening materials, raking out joints to 15mm depth, curing, taxes and royalty all complete as per building specification and direction of E/I. |
| 16 | Providing 12mm cement plaster (1:6) with clean coarse sand of F.M. 1.5 including screening, curing with all leads and lifts of water, scaffolding taxes and royalty all complete as per building specification and direction of E/I. |
| 17 | Finishing walls with Acrylic Smooth exterior paint of required shade : all complete as per building specification and direction of E/I. New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) |
| 18 | Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. 100x100x6 mm pipe |
| 19 | Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+ 0.05 %) total coated thickness with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineerin- charge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. |
| 20 | Providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm (+0.05 %) total coated thickness, Zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/ self tapping screws complete : Ridge |
| 21 | Providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm (+0.05 %) total coated thickness, Zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/ self tapping screws complete : Gutter (600 mm over all girth) |
| 22 | Stainless steel Turbo Air Ventilator for Roof, Wind Power Roof Exhaust Fan as required. |
| 23 | Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS: 4454 - part 1 and M.S. top cover of required thickness for rolling shutters. |
| 24 | Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS:13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required : |
| 25 | Supplying, fitting and fixing 20 guage G.C.I. Sheet gate fitted on M.S. Angle frame of size 60X60X6mm. Including cost of fabrication, providing necessary locking arrangement with haskal and domny duly fixed in P.C.C. (1:2:4) blocks of required size applying a priming red lead paint over steel work, taxes all complete as per drawing specification and direction of E/I. |
| 26 | Supply, fitting and fixing M.S. grill made of 20x6mm M.S. flat as per approved design and drawing, properly fabricated with joints continuous fillet welded and finished smooth, carriage of grill to work site, hoisting as per building specification and direction of E/I |
| 27 | Providing and laying Doublecharge vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622 / ISO 13006 of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete. Size of Tile 600x600 mm . |
| 28 | Providing and laying gang saw cut 18 mm thick, mirror polished pre moulded and pre polished machine cut granite stone of required size and shape of approved shade, colour and texture in footpath, flooring cut granite stone of required size and shape of approved shade, colour and texture in footpath, flooring in road side plazas and similar locations, laid over 20mm thick base of cement mortar 1:4 (1cement : 4 coarse sand) including grouting the joints with white cement mixed with matching pigment, epoxy touch ups etc. complete as per direction of Engineer-in-Charge. |
| 29 | Providing two coats of synthetic enamel paint & primer one coat of red lead paint approved shade and made over steel surface including cleaning the surface thoroughly, scaffolding and taxes all complete as per building specification and direction of E/I |
| 30 | Filling in foundation trenches and plinth in layers. Not exceeding 150 mm thick well watered, rammed fully compacted and fine dressed with earth obtained after cutting within a lead of 50 M and lift of 1.5 M all complete as per building specification and direction of E/I (Mode of measurement compacted volume) |
| 31 | Providing and fixing mineral fibre false ceiling tiles at all heights of size 595X595mm of approved texture, design and pattern. The tiles should have Humidity Resistance (RH) of 99%, Light Reflectance ? 85%, Thermal Conductivity k = 0.052 - 0.057 w/m K, Fire Performance as per (BS 476 pt - 6 &7)in true horizontal level suspended on interlocking T-Grid of hot dipped all round galvanized iron section of 0.33 mm thick (galvanized @120 gsm) comprising of main T runners of 15x32 mm of length 3000 mm, cross T of size 15x32mm of length 1200 mm and secondary intermediate cross T of size 15x32 mm of length 600 mm to form grid module of size 600x600 mm suspended from ceiling using galvanized mild steel item (galvanised@80gsm) 50 mm long 8mm outer diameter M-6 dash fasteners, 6 mm diameter fully threaded hanger rod up to 1000 mm length and L-shape level adjuster of size 85x25x2 mm, spaced at 1200 mm centre to centre along main ‘T’. The system should rest on periphery walls /partitions with the help of GI perimeter wall angle of size24x24X3000 mm made of 0.40 mm thick sheet, to be fixed to the wall with help of plastic rawl plug at 450 mm centre to centre & 40 mm long dry wall S.S. screws. The exposed bottom portion of all T-sections used in false ceiling support system shall be pre-painted with polyester baked paint, for all heights. The work shall be carried out as per specifications, drawings and as per directions of the engineer-in-charge. |
| 32 | Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth. |
| 33 | Providing 150mm. Wide brick drain in cement mortar (1:6) with av. 150mm clear depth and 125mm apron including cost of eartwork involved with 75mm cement concrete (1:4:3) over one brick designation 75A flat soling in proper grade and slope at the base the drain duly plastered in C.M. (1:3) with punning over exposed surface all complete as per building specification and direction of E/I. |
| 34 | Providing and laying 6mm precast white glazed tiles in walls over 12mm cement mortar (1:3) and jointed with grey cement slurry flush pointing with white cement including rubbing, polishing and cost of curring taxes and royalty all complete as per building specification and direction and E/I. |
| 35 | Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank |
| 36 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement ,trenching ,refilling & testing of joints complete as per direction of Engineer in Charge. eXTERNAL WORK 25 mm dia |
| 37 | Wiring for light point/fan point/ Exhaust fan point with 1.5 sq. mm FR PVC insulated copper conductor single core cable in surface/recessed PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq. mm FR PVC insulated copper conductor single core cable etc. as required. Group A |
| 38 | Wiring for circuit/submain wiring along with earthwire with the following sizes of PVC insulated copper conductor single core cable in surface/recessed PVC conduit as required. 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire |
| 39 | Wiring for circuit/submain wiring along with earthwire with the following sizes of PVC insulated copper conductor single core cable in surface/recessed PVC conduit as required. 2 X 4.0 sq. mm + 1 X 2.5 sq. mm earth wire |
| 40 | Wiring for circuit/submain wiring along with earthwire with the following sizes of PVC insulated copper conductor single core cable in surface/recessed PVC conduit as required. 4 X 6.0 sq. mm + 2 X 6.0 sq. mm earth wire |
| 41 | Supplying and fixing following size /module ,GI box along with modular base & cover plate for modular switches in recess etc as required 6 module |
| 42 | a)Supplying & fixing of following modular type switch/socket on the existing modular plate and switchbox including connection etc as required 5/6 Amp one way switch |
| 43 | Supplying & fixing of following modular type switch/socket on the existing modular plate and switchbox including connection etc as required 5/6 Amp 3 pin socket |
| 44 | Supplying & fixing of following modular type switch/socket on the existing modular plate and switchbox including connection etc as required 15/16 amps ,one way switch |
| 45 | Supplying & fixing of following modular type switch/socket on the existing modular plate and switchbox including connection etc as required 15/16 amps ,6 pin socket outlet |
| 46 | Supplying & fixing of following modular type switch/socket on the existing modular plate and switchbox including connection etc as required electronic fan regulator |
| 47 | Providing and fixing following rating and breaking capacity MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel ,making connections etc as required 150/160 amps ,35 ka ,fixed thermal setting |
| 48 | Supplying and fixing following way single pole and neutral,sheet steel ,MCB distribution board ,240 volt on surface/recess ,complete with tinned copper bus bar ,neutral bus bar ,earth bar ,din bar,interconnection ,powder painted including earthing etc as required(but without MCB/RCCB/ISOLATOR) 4 Way ,single door |
| 49 | Supplying and fixing following ways surface/recess mounting vertical type ,TPN MCB distribution board of sheet steel,dust protected ,duly powder painted ,inclusive of 200 amps tinnedcopper bus bar ,common neutral link ,earth bar ,din bar for mountingMCB’s (but without MCB’S and incommer) as required. 8 way(8+24),Double door,vertical type |
| 50 | Supplying and fixing 6 amp to 32 amp rating ,240 volt 10 KA ‘C’ curve miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connection ,testing and commissioning etc as required. 6/32 amp ,Single pole |
| 51 | Supplying and fixing 6 amp to 32 amp rating ,240 volt 10 KA ‘C’ curve miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connection ,testing and commissioning etc as required. 50/63 amp,TPN |
| 52 | Earthing with copper earth plate 600mmX 600mm X 3mm thick including accessories and providing masonary enclosure with cover plate having locking arrangement and watering pipe etc (with charcoal or coke and salt) as required |
| 53 | Supply and laying 8 SWG copper wire at 0.50 metre below ground level for conductor earth electrode, including soldering etc as required. |
| 54 | Supply, installation testing and commissioning of following size ceiling fan 3 blades confirming to IS :374:2019 including wiring the down rod of standard length (upto30cm) with 1.5 sq.mm FR PVC insulated copper wire suitable for 230 V 50Hz, single phase supply complete as required. 1200mm(48”)Ceiling fan |
| 55 | FR PVC insulated 3 core 4 sq.mm copper wire (for Service connection ) |
| 56 | Supply and fixing of 15/16 watt LED bulb |
| 57 | SITC of following rating LED FLOOD lighting luminarie with pressure die cast housing and toughned glass cover (ip 66 protection) in existing pole/pipe for supply voltage 100-270 V AC ,50Hz 50/60 W LED FLOOD LIGHT |
| 58 | Supply of PVC /XLPE insulated PVC sheated heavy duty ,armouredelectrical cable with alluminium conductor for working voltage upto and including 1100 volts. 35 sq.mm,3.5 core (M.line) |
| 59 | Laying of one number PVC insulated and PVC sheated /XLPE power cable of 1.1 KV grade of size not exceeding 35 sq.mm direct in ground including excavation and refilling the trench etc as required,but excluding sand cushioning and protective covering. |
| 60 | a)Carriage of constructional materials from nearest source to work site Sand lead 30 Km |
| 61 | Carriage of constructional materials from nearest source to work site Stone chips lead 30 KM |
| 62 | Carriage of constructional materials from nearest source to work site brick lead 8 km |
| 63 | Carriage of constructional materials from nearest source to work site EARTH (LEAD 1 K.M) |
| 64 | Add GST @ 18% |
| 65 | Add LWF @1 % Please Enable Macros to View BoQ information |