| 1 | Dismantling floor , hearth or wall tiling including cement mortar bedding (but including backing ) , rubbish off the premises complete all as specified and directed by engr-in-Charge |
| 2 | Demolition of cement concrete (un reinforced ) in ground floors and pavings n.exc 15cm thick (below or above ground level ) all as specified and removing debris ouside MD land. |
| 3 | Material & Labour 25mm thick PCC 1:2:4 type B-0 using12.5mm graded stone aggregate as in flooring and finished surface as in received tiles complete all as specified and as directed. |
| 4 | M&L for Vitrified tiles (light shade) 8 mm thick in size of 600mmx600mm as in floors/skirting/dados set and jointed in neat cement slurry and pointed in white or coloured cement to match and laid over 15mm thick cement slurry in CM 1:4 complete all as specified and/or as directed by Engr-in-Charge. |
| 5 | Taking down chowkhat or frame with shutters (without taking of shutters from the frame) exc 1.5 sqm each but not exc 4 sqm each any type of door (wooden, aluminium & steel etc) complete all as specified and/or as directed by Engr-in-Charge. |
| 6 | Taking down chowkhat or frame with shutters (without taking of shutters from the frame) not exc 1.5 sqm each any type of door (wooden, aluminium & steel etc) complete all as specified and/or as directed by Engr-in-Charge. |
| 7 | M&L for plain sheet glass 4.80mm thick ordinalry quality and glazing with oil putty or wooden beads in square or fixed with aluminium section including rubber beads not exc 0.50 sqm in each pane including hacking out complete all as specified and as directed by Engr-in-Charge. |
| 8 | S&F Door closer hydraulically regulated designation No 3 universal type, aluminium body suitable for door shutters of 851 to 1000 mm in width and of weight between 61 to 80 kg and fixed and fixed complete all as specified and directed. |
| 9 | S&F 2nd hard wood as in plain solid straight chowkhats wrought framed rebated on the solid put together on with glue pinned at joints, complete all as specified and/or as directed by Engr-in-Charge. |
| 10 | S & F 30mm thick 2nd class hardwood, plain, framed, panelled shutters (any number of panels), with panels of timber flat on both sides (feather edged), or of veneered particle board medium density, wood particle board with commercial face veneers: supplied and fitted to chowkhats, complete all as specified and/or as directed by Engr-in-Charge. |
| 11 | M&L for two coats of synthetic enamel paint over one coat of pink primer on new decorated wooden surfaces including preperation |
| 12 | S&F 200 mm long aluminium anodised barrel tower bolt of extruded section. |
| 13 | S&F 150mm Aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixed |
| 14 | S&F in 150mm long anodized aluminum door handle cast type. |
| 15 | S&F 100mm long mild steel medium weight but hinges cold rolled. |
| 16 | Taking down cement plaster on brick/pcc block or concrete surfaces including racking out joints hacking for key, scrubbing down with water etc., complete all as specified and/or as directed by Engr-in-Charge. |
| 17 | M&L rendering 15mm thick in CM 1:4 on fair faces of concrete or brick surfaces as in wall finishes even and smooth w/o using extra cement complete all as specified and/or as directed by Engr-in-Charge. |
| 18 | M&L rendering 15mm thick in CM 1:6 on other than fair faces of concrete or brick surfaces as in wall finishes even and smooth w/o using extra cement complete all as specified and/or as directed by Engr-in-Charge. |
| 19 | M&L for Preparing newly plastered surfaces of walls and applying two coats of acrylic emulsion paint over a coat of primer over a coat of wall care putty applied till the surface is smooth etc. complete all as specified and/or as directed by Engr-in-Charge. |
| 20 | M & L for Preparing newly plastered surfaces of walls and applying two coats of distemper oil emulsion over a coat of primer including 1mm thick birla wall care putty complete all as specified and directed |
| 21 | S&F Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws including dismantling all as specified and directed. |
| 22 | S&F Pre- painted galvalume aluminum zinc coating GI based plain steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws including dismantling all as specified and directed. |
| 23 | S&F rolled section as in main and cross beams ,hip and jack rafters , purelins where connected to common rafters and running rails and guides for sliding doors fixed with angle cleats or other connecting plates Fe -410 Gde E-250 |
| 24 | Dismantling structural steel work including doors and gates of any description. |
| 25 | Demolition brick work / block masonry or stone/ boulder masonry, built in built in cement mortar or cement lime mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stonework and precast concrete articles |
| 26 | Material and Labour precast cement concrete(20mm graded crushed stone aggregate) 1:3:6 type C-1 as in block masonry with solid blocks,exc.10cm in width and setting in cement mortar 1:6, complete all as specified and/or directed. |
| 27 | S&F 100mm long extruded brass handles, fabricated type polished complete all as specified and directed . |
| 28 | S&F 30mm width of flaps(when open) continous (piano) hinges, brass complete all as specified and directed. |
| 29 | S&F magnetic catcher with 8mm dia ball and brass body and stricking plate complete all as specified and directed. |
| 30 | Dismantling wall and ceiling boards (Fiber, pulp, insulation, blankets) any thickness including covered fillets and supporting members. |
| 31 | M & L Prelaminated particle board 9mm thk fix in walls interior grade, prelaminated one side with decorative choice lamination & other side balancing white lamination, fixed with screws to timber frame work |
| 32 | S&F in repairs for 2nd class soft wood clean sawn as in scantling fixed with nails including dismantling. |
| 33 | S&F in repairs 2nd class softwood clean sawn as in scantling fixed with nails exceeding 06 Sqcm and n.exc 13 Sqcm in section including dismantling. |
| 34 | M & L for providing and fixing Gypsum boards 9 mm thick PVC film on the face side and other side metalised polyster flim as in ceilings fixed with screws as per manufacturers instructions including anodised aluminium powder coated snap grid frame work of size 605 x 605 mm with anodised aluminium channel supports/ angles/ 'T' (Main tee 35 x 25 x 1.5 mm, cross tee 25 x 25 x 1.4 mm and wall angle 32 x 32 x 2 mm) fixed with screws/ plugs etc including GI suspenders of 6mm dia upto 1200 mm length adjusting level fixed to roof slabs by means of ceiling cleats made out of GI flat 40 x 3 mm size as per approved pattern and design complete all as specified and directed by Engr-in-Charge. |
| 35 | Material & Labour 75mm thick PCC 1:3:6 type C1 (using 20mm graded stone aggregate) as in plinth protection and finished concrete surface even and smooth without using extra cement including making proper joints with bitumen mastic with sand as per specification at an interval of 3m complete all as specified and as directed. |
| 36 | Taking down carefully copper/aluminium point wiring (light, fan, socket and power point) complete fittings such as switches, ceiling rose, regulators, socket etc and removing material from site and making good disturbed surfaces of walls, floors/ceiling to match the existing surface complete all as spd and directed. |
| 37 | Point wiring complete with 1.5 Sq.mm nominal area of copper conductor multi stranded PVC insulated and unsheathed 1100 volts cable drawn through & including PVC Casing & caping with standard accessories such as elbows, tees, junctions etc. and PVC moulded terminal box with top cover of including PVC insulated unsheathed solid 1.5Sqmm copper conductor cable as continuous earth lead all as specified and directed for the followings:- |
| 38 | One light/exhaust fan point controlled by one way switch |
| 39 | One 3 pin switch socket combination 6 Amp on independent board complete all as specified and directed. |
| 40 | One 3 pin socket out let 6 Amp on the same board with other switches complete all as specified and directed. |
| 41 | All as item No 37 above, but using cables 2.5 Sq mm size |
| 42 | Supply and replacement of lamp holder insulated body with back plate. |
| 43 | Supply and fixing of Switch piano flush button single pole 6 Amps 230 volts one way complete all as directed. |
| 44 | Supply and fixing of switch socket combination 5 amp-2/3 pin complete all as specified and directed. |
| 45 | Supply and fixing of Socket outlet 3 pin, 5A, flush type complete all as directed. |
| 46 | Supply and fixing of switch Socket combination 5 pin 6 & 15 Amps flush type.230 volts complete all as spd and directed. |
| 47 | Supply and fixing of Ceiling rose, surface Bakelite three terminals complete all as directed. |
| 48 | Supply and fix in replacement of sheet metal enclosure for DBs double door when MCB's to be used single pole & neutral 240 Volts 8 Ways all as specified and directed by Engr-in-Charge. |
| 49 | Supply and fix in replacement of sheet metal enclosure for DBs double door when MCB's to be used single pole & neutral 240 Volts 12 Ways complete all as spd and directed. |
| 50 | Supply and fix in replacement of sheet metal enclosure for DBs double door with MCCB 125 Amps and MCBs single pole 6-32 Amps tripple pole & neutral 415 Volt 8 Ways complete all as spd and directed. |
| 51 | Supply and fix in replacement of MCB SPN 63 Amp 240 Volts AC ISI marked complete all as spd and directed. |
| 52 | Supply and fix in replacement of MCB SP 6-32 Amps. 240 Volts AC ISI marked complete all as spd and directed. |
| 53 | M & L for submain wiring alongwith earth wire with the following sizes of FRLSH PVC insulated copper conductor, single core cable in surface/recessed as required in PVC casing Caping wire size 2x4.0 sq. mm + 1x4 sq. mm earth wire incl taking down existing complete all as spd and directed. |
| 54 | M & L for submain wiring alongwith earth wire with the following sizes of FRLSH PVC insulated copper conductor, single core cable in surface/recessed as required in PVC casing Caping wire size 2x6.0 sq. mm + 1x6.0 sq. mm earth wire incl taking down existing complete all as spd and directed. |
| 55 | Supply and fixing LED luminaire 600 mm x 600 mm, 35/36 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size incl taking down existingcomplete all as spd and directed.. |
| 56 | Supply and fixing in replacement LED lights fitting 1x 18W, 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete. |
| 57 | Supply and fixing in replacement LED light fitting mirror type with high out put diffuser 2 feet, 10 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete. |
| 58 | S&F in replacement of Old U/S Lamp LED 7/9 Watt, 230 volts 50 Hz AC complete all as specified. |
| 59 | Supply and fixing in replacement Air circulator made of sturdy Engineering plastic complete with louvers, shutter, voltage 230 volt, 50 Htz RPM 1200, copper winding of sweep 250 mm complete all as specified and directed by Engr-in-Charge. Please Enable Macros to View BoQ information |
| 60 | Supply and fixing in replacement Air circulator made of sturdy Engineering plastic complete with louvers, shutter, voltage 230 volt, 50 Htz RPM 1200, copper winding of sweep 250 mm complete all as specified and directed by Engr-in-Charge. Please Enable Macros to View BoQ information |