| 1 | Providing,erecting and giving test of 150mm diameter submercible pumps set confirming to IS 8043 and IS 9283 pump shall be sutaible for various delivery head and discharge with stainless steel pumps shafts and bronze impellars. Motor suitable for working on 415 volts +10% 3 ph,50 hz AC supply. suplly cable guards, thrust carbon/ fiber bearing to accept entire hydraulic thrust, waterproof winding shall be provided. The pump sets shall be suitable for 7.5 Hp |
| 2 | Providing,erecting and giving test of 150mm diameter submercible pumps set confirming to IS 8043 and IS 9283 pump shall be sutaible for various delivery head and discharge with stainless steel pumps shafts and bronze impellars. Motor suitable for working on 415 volts +10% 3 ph,50 hz AC supply. suplly cable guards, thrust carbon/ fiber bearing to accept entire hydraulic thrust, waterproof winding shall be provided. The pump sets shall be suitable for 20 HP |
| 3 | Supplying and erecting, flat flexible submersible cable with, copper conducter, PVC insulated,and PVC sheathed 3 core x6 sqm |
| 4 | Providing erecting multi programmable automatic control unit suitable for submersible pump sets with test and trial with 2 years guarantee and also five visits for periodical maintenance during the guaranteed period. The control unit shall be suitable for programming independently for 2 shifts, shall incorporate running time compensation arrangement for loss of time due to power failure and shall have protections against under voltage over voltage, single phasing, wrong phase sequence and low water level with time delay to prevent nuisance tripping suitable for single pump set for single pump. up to 7.5 HP |
| 5 | Providing erecting multi programmable automatic control unit suitable for submersible pump sets with test and trial with 2 years guarantee and also five visits for periodical maintenance during the guaranteed period. The control unit shall be suitable for programming independently for 2 shifts, shall incorporate running time compensation arrangement for loss of time due to power failure and shall have protections against under voltage over voltage, single phasing, wrong phase sequence and low water level with time delay to prevent nuisance tripping suitable for single pump set for single pump. up to 20 HP |
| 6 | Excavation for foundation/pipe trenches in hard murum & boulder including excavated materials including normal dewtering etc complete. |
| 7 | Excavation for foundation / pipe trenches insoft rock by chiselling where necessary & removing the excavated material & stacking it in measurable heaps within a distance of 50 m from the area & lifts as below, normal dewatering, excluding the backfilling etc complete. |
| 8 | Excavation for foundation / pipe trenches in hard rock by chiselling where necessary & removing the excavated material & stacking it in measurable heaps within a distance of 50 m from the area & lifts as below, normal dewatering, excluding the backfilling etc complete. |
| 9 | DismantlingdeadpipelineofM.S./R.C.C./ C.I./P.S.C. andG .I./A.C./P.V.C./S.W./H.D.P.E.pipeincludingcostofnecessary excavation and refilling of trenches, breaking the joints, lifting thepipesand stacking to the place as directed by Engineer-in-chargewithall leadsand lifts including cleaning the surface, etc. complete.50 mm dia |
| 10 | Providing and supplying ISI mark GI pipe of following class and dia including all taxes,loading and unloading, octri,transportation including etc complete 80 mm dia GI Pipe B class |
| 11 | Lowering and laying, jointing of ISI mark GI pipe of following class and dia including hydraulic testing etc complete.80 mm dia GI Pipe B class |
| 12 | Hydraulic testing of G. I. pipe line to specified pressure including cost of all materials and labour and water for testing for the length upto 1km usingreciprocating type pumps which should be able to provide specified test pressure gauges and other necessary equipments, labour operation charges etc.required for testing, The rates under this item shall also include cost of retesting if necessary and reinstatingtooriginalpostion.80 mm dia GI Pipe B class |
| 13 | Providing ISI mark CI double short body type manually operated sluice valve of following dia including all taxes ,loading and unloading ,transportation etc complete. 150 mm dia Sluice valve PN1.6 |
| 14 | 100 mm dia Sluice valve PN1. |
| 15 | 80mm dia Sluice valve PN1 |
| 16 | Providing ISI mark CI double short body type manually operated Non return valve of following dia including all taxes ,loading and unloading ,transportation etc complete. 150 mm dia NRV |
| 17 | Lowering and laying ,jointing of MJP standard Sluice valve,NRV of following class and dia including testing etc complete. 150 mm dia Sluice valve PN1.6 |
| 18 | 100 mm dia Sluice valve PN1. |
| 19 | 80mm dia Sluice valve PN1 |
| 20 | Supply of CI Mechanical compression coller coupling sutaible for ci spun pipe and complete with sealing rubber gasket etc complete 80 mm dia |
| 21 | 100 mm dia |
| 22 | 150 mm dia |
| 23 | Providing and supplying D.I. fittings with ISI mark Mechanical joint confirming to tables12 to table31of IS 9523/2000upto latest amendments includingcost ofSBR/EDPMgaskets, Nuts, Bolts, Washers and Ductile iron follower glands. Fittingsshouldbewith internallyOrdinary portland cementmortor linedand externallymetallic zinc coating/zinc richpaintwith finishing layer of blackbitumen coating including transportationandexcludingall statutary dutiesandtaxessuchasGSTleviedbyGolandGoMinall respect etc. complete.150 mm dia |
| 24 | Providing and supplying Air Valves as per IS-14845-2000 and MJP’s standard specifications of approved make and quality offollowing diameters including railway freight,inspection charges, unloading from railway wagons, loading into truck, transportation upto departmental stores, unloding and stacking excluding GST levied by GOI & GOM in allrespectetc.complete.25 mm dia single ball PN1 |
| 25 | 50 mm dia single ball PN1 |
| 26 | Lowering, laying and fixing in proper alignment and position all types of C.I. air valves as directed by Engineer-in-chargeincluding cost of conveyance from stores to site of work, cost of all material and giving satisfactory hydraulic testing, etc. complete.(for all class of valves). |
| 27 | 50 mm dia single ball PN1 |
| 28 | Providing and fixing in position air valve shaft including providing and fixing GI Medium Class or 6mm thick M.S.pipeshaft2.70M long over branch flange of air valve tee, providingPCCblockofM-150concrete,150mm thick around theair valve tee including encasingof vertical shaft inPCCM-150as shown in typedesign togethe r with providing andmaking flanged jointswherever required and fixing of air valvetee,etc.completeasper type design and asdirectedbyEngineer-incharge for followingdiameters of pipe lines(typedesignattached.) |
| 29 | Providing and constructing B.B. masonry valve chamber with 15 cm thick 1:3:6 proportion PCC bedding,excludingexcavation,B.B.masonryinCM1:5proportion precast RCC frame and cover, etc. completeasdirectedbyEngineer-in-charge.As above of 90 x 90 cm internal size and depth upto1.2MwithprecastR.C.Cslabcover. |
| 30 | Providing and supplying C.I. detachable joints suitable for A. C. pressure pipes manufacturedasper IS-1538-1993standardsof followingcalassanddiameter includingcost of insurance, railway freight, inspection charges,unloding fromrailwaywagon, loding into truck,transporting to departmental store, unloading, stacking and cost of rubber rings, nut bolts. excludingGST leviedbyGOI &GOM in all respectetc.complete(IS-1538-1993) 80 mm |
| 31 | 100 mm dia |
| 32 | 150 mm dia |
| 33 | Supplyof C. I.Mechanical Compression Flanged / Socket Tailpiece (Popularlyknownas I TMFlanged /Socket Tailpiece) suitable for making flanged connection with the plain barrel of C. I.SpunPipes (asper- IS-1536/2001)andD. I.Pipes(asper IS: 8329 / 2000).TheTailpiec to be supplied complete with sealing rubber gaske to fS.B.R,C.I.FollowerGlandsandM.S.NutBolts.The wholeassemblyshouldbemechanicallyandhydraulicallytestedto theprovisionsaslaiddowninIS:1538/1993.Theratesareinclusive of cost of material, freight charges, loading, transportation and unloadingatdepartementalstore,excludingGST 80 mm |
| 34 | 150 mm dia |
| 35 | Providing uncoursed rubble masonry of trap / granite / quartzite / gneiss stones in cementmortar 1:6 infoundation and plinth of innerwalls / in plinth of external walls including bailingoutwatermanually strikingjointsonunexposedfacesand watering etc.complete. |
| 36 | Providingsecond classBurnt Brickmasonrywith conventional/ I.S. type bricks incementmortar 1:6 in superstructure including striking joints, raking out joints, watering and scaffolding etc. Complete |
| 37 | Providing hoisting and fixing in position sintex or equivalent high density polyethylene UV stabilized conforming to I.S.12701, water storage tank with necessary connections, testing & all required accessaries etc. complete. (Prior approval of sample by Ex. Engineer is necessary before use.) |
| 38 | Providing and supplying GI special in position with necessary materials etc complete, 75 mm dia Bend,elbow,tees,union.coupler |
| 39 | Providing and laying in situ following grades of C.C.of trap/granite/gneiss metal for foundations and bedding including dewatering, formwork, compacting and curing, finishing, etc complete |
| 40 | Providing and casting in situ C.C. of trap / granite/ quartzite / gneiss metal of approved quality for RCC works as per detailed drawings and designs or as directed by eng in-chatge including normal dewatering, centering, form work, compaction, finishing the formed surfaces with C.M. 1:3 of sufficient minimum thickness to give a smooth and even surface wherever necessary or roughening if special finish is to be provided and curing, etc. complete. (By weigh batching and mix design for M-250 and M-300 only. Use of L&T, A.C.C., Ambuja, Birla Gold, Manikgad, Rajashree, etc. cement is permitted.) (Excluding M.S. or Tor reinforcement) |
| 41 | Providing and casting in situ C.C. of trap /granite/ quartzite / gneiss metal ofapproved quality for RCC works as perdetailed drawings and designs or asdirected by Engineer-in-chargeincluding normal dewatering, centering,form work, compaction, finishing theformed surfaces with C.M. 1:3 ofsufficient minimum thickness to give asmooth and even surface wherevernecessary or roughening if special finishis to be provided and curing, etc.complete. (By weigh batching and mixdesign for M-250 and M-300 only. Use ofL&T, A.C.C., Ambuja, Birla Gold,Manikgad, Rajashree, etc. cement ispermitted.) (Excluding M.S. or Torreinforcement) |
| 42 | Providing and casting in situ C.C. of trap /granite/ quartzite / gneiss metal ofapproved quality for RCC works as perdetailed drawings and designs or asdirected by Engineer-in-chargeincluding normal dewatering, centering,form work, compaction, finishing theformed surfaces with C.M. 1:3 ofsufficient minimum thickness to give asmooth and even surface wherevernecessary or roughening if special finishis to be provided and curing, etc.complete. (By weigh batching and mixdesign for M-250 and M-300 only. Use ofL&T, A.C.C., Ambuja, Birla Gold,Manikgad, Rajashree, etc. cement ispermitted.) (Excluding M.S. or Torreinforcement) |
| 43 | Providing and fixing in position steel reinforcement bar of various diameters for RCC piles, caps, footings, foundations, slabs, beams, columns, canopies,staircases, newels, chajjas, lintels, pardies, copings, fins, arches, etc. as per detailed designs, drawings and schedules;including cutting, bending, hooking thebars, binding with wires or tack welding and supporting as required, etc. complete(including 17/306) |
| 44 | Providing and fixing steel window of various size sas per detailed drawing without hot dip zinc coating, without ventilators, including fabricating / glazingwith plain /obscured glass panels of approved type and quality, iron oxidised fixtures and fastenings,finishingwithoilpaintingtwocoatscomplete(withguardbars12mmsquare at 10 cm c/c. |
| 45 | Providing and fixing rolling shutter fabricated from steel laths of minimum thickness 0.9 mm with lock plate of 3.15mm thickness reinforced with 35x35x5mm angle section fitted with sliding bolt sand handles for bothsides,deepM.S.channel sectionofdepthand thickness not less than 65 mm and 3.15 mm respectively with hold fastarrangements,M.S.Bracketplate300x300x3.15mmminimumsizeandshapewithsquarebar,suspensionshaftofminimum32mmdiameter,hoodcoverofM.S.sheetnotless than 0.9mm thickness and of any size at top and safety devices includingmechanicalgearoperationarrangement consistingofwormgearwheelsandwormsofhighgradecast ironormildsteel andonecoatof redleadprimeretc. complete. (I.S.62481979) (Without mechanical gear) |
| 46 | Providing and fixing on wall/ceiling/floor 15 mm dia CPVC pipe with necessary fitting,remaking good the demoshied portion etc complete.including removing existing pipe line if necessary and convryaing and stacking the same in PWD chouky or as directed etc complete. |
| 47 | Refilling the trenches from excavated stuff with soft material in 15 cm layers with all leads & lifts including consolidation surcharging … etc complete. |
| 48 | Providing structural steel work and UCR works in single stanchions composed of RSJ, channel, etc with caps,bases, mild steel plates,angles,brackets,cleats, gussets plates,anchor bolts etc as per detailed design and drawing or as directed by engineer in charge including cutting,fabrication,hoisting,errecting fixing in position, making riveted/ bolted/welded/ connections and one coated of anticorrosive paints and over it two coats of oil painting etc complete |
| 49 | Providing and fixing corrugated galvanised iron sheets of 0.63mm thick(24B.W.G.)for roofing without wind tiles including fastening with galvanised iron screws and bolts, lead and bitumenwashers as per drawing etc. complete.(Weight of 5.5Kilogram/sq.m.). |
| 50 | Providing and laying concrete pipes of I.S.NP.class of 300mm diameter inproper line,level andslope including necessary collars, excavation, laying, fixing with collars in cement mortar 1:1 and refilling the trench complete |
| 51 | Dismantling the existing submersible pump with GI pipeline up to 10m depth. (For additional depth of each 3 m or part thereof add Rs.50/- per 3 m, inthe rates) 7.50 hp |
| 52 | Desilting theSupplyWell, IntakeWell / Head Works, Sump of water supply / sewerage worksetc. in wet or dry condition including lifts upto 9M and lead upto150 M as required beyond the work site,stacking, spreading, including necessaryguarding, etc. complete, as directed by Engineer-in-charge. |
| 53 | Providing flush grooved pointingwith cementmortar 1:3 for stonemasonrywork including scaffolding and curing etc. complete. |
| 54 | Providing, installing and giving satisfactory field testing offlanged ends Bulk water meter of following type and as mentioned below with FGI-250 cast iron body, class \\"B\\" conforming to IS : 2373, to read in metric system,alongwith manufacturer's test and guarantee certificate including cost of all materials and labour with ISI mark etccomplete. 150 mm dia |
| 55 | Providing,and fixingC.I.Strainer for water meters including cost of all material and labour.of \\"T\\"(Basket)Type with flange dends and with stainless steel or brass meshwith openings of2.5.mm to 3 mm and suitable for operating pressure of 16 Kg./cm2 and test pressure of 24 Kg./cm2 ,150 mm dia |
| 56 | Scrapping the old plastered internal surfacewith sand paper and coating theentire surfacewithmixture ofwhiting or glue and linseed oil including scaffolding etc. complete as directed. |
| 57 | Providing rough cast cement plaster externally in two coats to concrete, brick or stone masonry surfaces in all positions with base coat of 12 to 15mm thick in C.M.1:4 and roughcast treatment 12mmthick in proportion 1:1 1/2:3 including scaffolding and fourteen days curing complete. |
| 58 | Supplying, installing, testing and commissioning Solar street light pole comprising of 12W LED luminaire, 12.8V- 30Ah Li battery, with 75Wp Solar panel, MS Powder Coated Battery Box weatherproof, mounted on 75/80 mm dia. BGrade GI Pole of 6 Mtr. height (5m above ground & 1m below ground), 12W LED Chip of luminaire should be in compliance to IES: LM-80 & Performance parameters of luminaire shall be as per IES LM-79:2008 Or IS 16106 : 2012); along with brackets, foundation, earthing and necessary accessories complete as per MNRE specification |
| 59 | Point wiring for independent plug in minimum 20 mm HMS PVC conduit with 1.5 sq.mm (2+1E ) FRLSH grade copper wire, modular type switch,earthing and required accessories as per specification no. WG-PW/SW |
| 60 | Point wiring for ceiling fan concealed type in min 20 mm HMS PVCconduit with 1.5 sq.mm. (2+1E) FRLSH grade copper wires, modulartype switch, earthing and required accessories as per specification no. WG-PW/CW |
| 61 | Providing and applying two coats of exterior acraylic emulsion paint confirming to corresponding I.S. of approved manufacture and of approved colour to the plastered surfaces including cleaning ,preparing the plaster surface, applying primer coat,scaffolding if necessary , and watering the surface for two days etc complete |
| 62 | Providing and applying twocoats of flat oil paint of approvedcolour andshade to internal / external plastered surfaces including scaffolding if necessary, cleaningand preparing the surface (excluding primer coat) etc. complete. |
| 63 | Dewatering the excavated trenches and pools of water in the building trenches/pipeline trenches,well works by using pumps andother devices including disposing off water to safe distance as directed by Engineer-in-charge (including cost of machinery,labour,fuel),etc.complete.(Bd-A9/261) Please Enable Macros to View BoQ information |