| 1 | Dismantling of asbestos cement sheet (corrugated, semi-corrugated etc) sheets in roof coverings complete all as specified and as directed. |
| 2 | Dismantling of singel layer mangalor pattern tiles in roofing complete all as specified and as directed. |
| 3 | Dismanling of plain or corrugated steel sheeting, any gauge thickness, incl Nanital or similar pattern roof coverings complete all as specified and as directed. |
| 4 | S&F Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and as directed. |
| 5 | S&F Pre- painted galvalume aluminum zinc coating GI based plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and as directed. |
| 6 | Dismantling mild steel work of any description not otherwise provided complete all as specified and as directed. |
| 7 | M&L for Roof trusses (framed), trussed, purlins, crane ganbies, rails and fastenings and heavy bracket framing (beam, tee, angle, charmel tubular or flat sections) including distance pieces, cleats etc conforming to IS 1161-1979 grade Fe 290 (Gde E-165) complete all as specified and as directed. |
| 8 | Dismantling timber scantlings in frame work 40 sq. cm and over in section, in any position complete all as specified and as directed. |
| 9 | M&L 2nd class hard wood in scantling clean sawn and unframed timber complete all as specified and as directed. |
| 10 | Dismantling wall and ceiling boards ( Fiber, pulp, insulation etc) or insulation boards, slabs, blankets or of any description in any thickness including cover fillets complete all as specified and as directed. |
| 11 | Material and labour 4mm thick for Non asbestos fibre cement building boards fixed or laid/ inserted to timber/GI/Alumi nium framework with screws complete all as specified and as directed. (Noted: Grid shall be measured seprately) |
| 12 | M & L for Gl powder coated snap grid frame work for flase ceiling comprising of the following section for making partition of 600x600 mm size fixed to wall with rawl plug and screw and hanged to roof with 2mm Gl supended wire of suitable length and butter fly clip of size of main Tee shall be 32mmx 15mm x 0.30mm, cross Tee shall be 32mm x 15mm x 0.30mm thick and wall angle shall be 24mm x 24mm x 0.30mm thick complete all as specified and as directed. |
| 13 | Dismantling of brick work or stone/boulder masonary built in cement mortar including ashlar facing dressed stone and pre-cast concrete articles complete all as specified and directed |
| 14 | M&L for old size brickwork with fly ash bricks, straight or curved on plan exc 6m mean radius, built in CM 1:6 complete all as specified and as directed. |
| 15 | Taking down cement or cement lime plaster, any description on brick or stone wall, etc including raking out joints hacking for key, scrubbing down with water etc complete all as specified and as directed. |
| 16 | M&l for rendering 10mm thick in cement plaster in cement mortar 1:6 , finished even and smooth without using extra cement complete all as specified and as directed. |
| 17 | M&L for 15mm thick rendering CM 1:4 on fair faces of brick work using water proofing compound as per manufacture instruction (WPC shall be measured separately) complete all as specified and as directed. |
| 18 | Supply only liquid water proofing admixture of make-pidilite or equivalent complete all as specified and as directed. |
| 19 | Dismantling floor, heart or wall tiling including cement mortar bedding (but not backing ), removing serviceable tiles to store and rubbish off the premises complete all as specified and as directed. |
| 20 | Demolation of cement concrete in ground floor and paving nexc 15cm thk below or above ground level as specified and directed. |
| 21 | M&L Plain Cement concrete in sub bases/pavings Type D2 1:4:8 (40mm graded aggregate) all as specified and directed. |
| 22 | M & L for providing 25 mm thick PCC 1:2:4 Type B-2 (using 20 mm graded stone aggregate) as in flooring including finishing the cement concrete surface even and smooth with using extra cement complete all as specified and as directed. |
| 23 | M&L vitrified ceramic tiles 10 mm thick (square or rectangular) polished, light shed area of each tile not exceeding 0.36 sqm in floors etc set and jointed in neat cement slurry and pointed in site or colored cement to match over 15mm cement screed bed in cement mortar 1:4 with fixing of using by spacers & filled with epoxy grouting and all as specified and directed. |
| 24 | M&L vitrified ceramic tiles 10 mm thick (square or rectangular) polished, light shed area of each tile not exceeding 0.36 sqm in Skirting etc set and including rendering 10mm thick in cement mortar 1:3 complete all as specified and as direted. |
| 25 | M&L joint free colored non skid ceramic tiles 6 to 7 mm thick (square or rectangular) area of each tile exceeding 0.06 sqm but not exc 0.11 Sqm in floors etc set and jointed in neat cement slurry and pointed in site or colored cement to match over 15mm cement screed bed in cement mortar 1:4 as specified and directed. |
| 26 | M&L colored glazed ceramic tiles in vertical surface 300x 450x 6-7mm thick set and jointed in neat cement slurry and pointed in site or color cement to match including rendering 10mm thick in cement mortar 1:3 complete all as specified and as direted. |
| 27 | M&L for Granite 20 mm thick (of any type) work (table rubbed and polished) in steps, jambs, pillars, win dow-cills, cooking plat forms and like in cement mortar (1:4) including point ing in white cement (1:2) us ing marble dust with admix ture of pigment to match with shade of granite complete all as 'specified and as directed. |
| 28 | M & L for machine cut cudappa stone slab 20 - 25 mm thick over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete all as specified and directed. |
| 29 | Rounding to edges of stone slabs one edge , such as in steps ,cooking platforms, and other similar situations complete all as specified and as directed. |
| 30 | M&L for Machine cut kota stone slab flooring 20-25mm thick over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete all as specified and as directed. |
| 31 | M&L for Kota stone slab 20-25mm thick in riser of steps, skirting, dado and pillar laid over cement screed and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete all as specified and as directed. |
| 32 | Taking down door / window frame with shutter of any description (without taking of shutter from the frame ) area not exc 1.5 sqm complete all as specified and as directed. |
| 33 | Taking down door / window frame with shutter of any description (without taking of shutter from the frame ) but area exc 1.50 sqm but not exc 4 sqm complete all as specified and as directed. |
| 34 | Cutting into existing manholes for connecting new drains, making good to pipe and rendering, cutting out existing benching and forming branch channel 91/1 round or 3/4 section ) in cement concrete 1:2:4 type B-1 smooth finished and reforming benching as orginal formation complete all as specified and as directed. |
| 35 | S&F and 2nd class hard wood plain solid straight chowkats & frame wrought framed on the solid rounded or chamfered put together with glue pinned at joints complete all as specified and as directed. |
| 36 | S&F 35 mm thick plain framed panelled factory made shutter made out of IInd class hard wood rail and styles and panel of 12 mm thick veneered particle board or 9 mm thick plywood with commercial veneering on both faces the size of rail and style as per IS 1083 (part-I) kiln seasoned an chemically pressure freated of any number of panel complete all as specified and as directed. |
| 37 | S&F 30 mm thick second class hard wood for windows glazed and ,skeleton shutter open and prepared to receive glass , gauge etc. (without sash bars), edge of framing plain,chamfered or rounded. Fitted with cut and mitred beads for securing glass etc size of member of shutters as specified in SSR part -I complete complete all as specified and as directed. |
| 38 | S&F galvanized mild steel wire cloth 0.56mm nominal dia of wire and average width of aperture 1.18mm and fixed with tinned tacks or galvanized wire staples complete all as specified and as directed. |
| 39 | S&F Solid PVC Door Frame of size 50 mm x 47 mm made out of 5mm plain colour PVC sheet reinforced with M.S Square tube, supplying & fixing in opening as per specified and as directed. |
| 40 | S/F Factory made solid PVC panelled door shutter 30mmthick (Style) consiting of frame made out of MS tubes for top & bottom rails ,MS frame shallbe covered withheat moulded plain coloured PVC 'C' channel having PVC sheet strip of 20 mm width struck inside with solvent cement for styles and palin colour PVC sheet for Toprail : panelling of plain colour PVC sheet to be fitted in the MS frame welded/sealedto the style and rail withsuitable PVC sheet beading and jointed toghether with solvent cement etc fixed with frame at site complete all as specified and as directed. |
| 41 | S&F framed work such as grills ,guard bars with mild steel Square bars with ends of bars shouldered and/ or riveted and similar work confirming to FE 290 Gde-E-165 Please Enable Macros to View BoQ information |
| 42 | S&F framed work such as grills ,guard bars with mild steel Square bars with ends of bars shouldered and/ or riveted and similar work confirming to FE 290 Gde-E-165 Please Enable Macros to View BoQ information |