| 1 | Surface excavation n.exc. 30 cm deep and averaging 15 cm deep and getting out in soft/loose soil complete all as specified and as directed |
| 2 | M & L for Hard core of guage not exc 63 mm with broken stone/boulders deposited spread & levelled in layers n.exc 15cm thick, watered & ramed to a true surface complete all as specified and as directed. |
| 3 | M & L for Cement concrete in foundations , filling and mass concrete type C-2, 1:3:6 (40 mm graded) all as specified and directed. |
| 4 | Providing and laying 80 mm thick factory made chamfered edge cement concrete paver block of M-40 grade with approved colour, design & pattern as in footpath, parks, lawns, drive ways or light traffic parking etc., of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over and including 50mm thick compacted bed of coarse sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with fine sand and cutting of paver block as per required size and pattern, finishing and sweeping extra sand; complete. |
| 5 | Material and labour for PCC 1:2:4 type B0 (using 12.5 mm grade crushed stone aggregate) as in , coping or similar work including all necessary formwwork complete all as specified and as directed. |
| 6 | Demolition of Concrete in ground floors and pavings n exc 15 cm thickness (below or above ground level) complete all as specified and directed |
| 7 | Dismantling of Wall and ceiling boards (fibre, pulp, insulation, etc.) or insulation boards/slabs/ blankets, any thickness, including cover fillets complete all as specified and directed |
| 8 | Dismantling structural steel work including doors, gates and Window but excluding framed truss etc.complete all as specified and directed |
| 9 | DismantlingPlain or corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern roof coverings complete all as specified and directed |
| 10 | M&L for old size sub Class B bricks, straight or curved on plan exc 6 m mean radius built in cement mortar ( 1:6) having compressive strenght not less than 75 kg/Sq cm all as specified and directed. |
| 11 | Material and labour for 10 mm thick rendering in cement mortar (1:6) on fair face of brick or concrete surface finished even and fair all as specified. |
| 12 | M&L Applying two coats of Oil bound distember to newly plastered/previously untreated wall over a coat of 1 mm layer wall care putty over a coat of primer including preparation of newly platsered wall all as specefied and directed. |
| 13 | M & L Forming Contraction (Dummy) joints 65mm deep x 10mm wide, filled with sealing (Grade A )Compound complete all as specified and directed. |
| 14 | M& L Reinforced cement concrete (nominal mix) (Type B1 1:2:4 20 mm Aggregate ) in Foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete complete all as specified and directed. |
| 15 | M & L 25 mm thick PCC 1:2:4, type B-0, (12.5mm graded crushed stone aggregate) as in floor complete all as specified and directed |
| 16 | M&L Formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter complete all as specified and directed. |
| 17 | M & L Formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including sup- ports, overhangs, etc. also splays between floors and beams, etc..complete all as specified and directed. |
| 18 | M & L Mild steel barsTMT Bar 10mm dia and over, cut to length, bent to shape required, including cranking, bending,mspirally for hooping for columns, hooking ends and binding with and includingmild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed. |
| 19 | Ditto, TMT Bar but 5mm dia and over upto and including 10mm dia in stirrups, spacers and binders complete all as specified and directed. |
| 20 | M&L for Non - skid Ceramic tiles 7 to8 mm thick area of each tile exceeding 0.18 sqm but notexceeding 0.38 sqm, infloors etc. set and jointed inneat cement slurry and pointed in white or coloured cement to match ,in cement mortar 1:4 to complete all as specified and directed. |
| 21 | M&L Non - skid Ceramic coloured tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm, in Skirting/Dado etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over 10 mm thick rendering in CM 1:4. |
| 22 | M & L 50 mm thick PCC 1\\"3\\"6, type C-2 (using 40mm gradedcrushed stone aggregate) as in plinth protection complete all as specified and directed. |
| 23 | M &L for Non asbestos fibrecement buildingboards 4 mm thick fixed orlaid/ inserted to timber/GI/Aluminium frameworkwith screwcomplete all as specified and directed. |
| 24 | M & L Hangers 6 mm dia. G.I. (upto 1200mm length) adjusting level fixed to roof slabs by means of ceilling cleats made out of G.I. flat 40 x 3 mm size 60mm long and expansion hold fastenersn12.5mm dia. 40mm long complete all as specified and directed. |
| 25 | M&L for Gl frame work for seamlessc e i l i n g c o m p r i s i n g o f G l perimeter channnel 0.55 mm thick with two unequal flanges of 20 and 30 mm and web of 27 mm fixed to surrounding wall using nylon sleeves and screws at 450 mm centre to entre/intermediate channel 0.9 mm thick having two equal flanges of 15 mm each and web of 45 mm suspended from soffit at approx 900 mm centre to centre with Gl cleat and steel expansion fasteners wit mm thickness having kurled web of 50 mm and flange of 26 mm each with lips of 10.5 mm fixed to the intermediate channel with connecting clips a c r o s s t h e i n t e r m e d i a t e channel at 457 mm centre to centre complete all as specified and directed. |
| 26 | Supplied and fixed Pressed steel frames of size 125 x 60mm for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc., complete, as specified, |
| 27 | S&F Anodised aluminium frame (Two/three track) for doors, windows, ventilators with one or more rebates including joining cleat for fixing etc. complete all as specified |
| 28 | S&F Anodised aluminium window and ventilator shutters, sliding type without sash bar, aluminium section weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws, etc.complete all as specified. |
| 29 | S& F 4.0 mm thick sheet glass ordinary/tinted quality and glazing with oil putty in squares exc 0.5 sq. m in each pane in squares. |
| 30 | Supply and fix, 30 mm thick, flush shutters, solid core construction, with particle board core and ply wood face panels commercial type on both sides all as specified and directed |
| 31 | S&F 35 mm thick 2nd class hard wood Glazed and skelton shutter(minimum three panel) open rebated and prepared to receive glass, gauze etc edges of the framing plain chamfered or rounded fitted with cut and mitred beads for securing glass etc sizes of members as specified all as specified and directed |
| 32 | S&F Stainless steel wire cloth.0.36 mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples |
| 33 | S & F Butt hinges, medium weight, cold rolled mildsteel 100 mm, and fixed complete all as specified and directed. |
| 34 | S & F Aluminium anodised, barrel tower bolts of extruded section and fixed complete all as specified and directed. |
| 35 | S & F Aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixedcomplete all as specified and directed. |
| 36 | S & F Mild steel 300mm, ordinary rat tail rod pattern springs including roller and roller plate complete all as specified and directed. |
| 37 | M & L for 15 mmthick Rendering(Internal Plastering) in cement mortar 1:6 on fair faces of brickwork or concrete surface without using extra cement .complete all as specified and directed. |
| 38 | M&L for two coat of synthetic enamel paint over a coat of Pink Primer, including prepration of new untreated wooden surface over 10 cm width complete all as specified and directed. |
| 39 | S&F Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified complete all as specified and directed. |
| 40 | Refixing except sheeting galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified complete all as specified and directed.(Note:- Sheet obtained from the dismentling shall be used for refixing) |
| 41 | S&F Pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified complete all as specified and directed. |
| 42 | M&L Chequered cement concrete colour tiles 30cm x 30cm x 25mm thick, set, jointed and pointed in neat cement slurry in floors over 20 mm screed bed in cement mortar 1:4 complete all as specified and directed. |
| 43 | Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc.removing materials all as specified and directed by engineer in charge. |
| 44 | M&L for point wiring with PVC insulated unsheathed stranded copper conductor cable of size 1.5 Sq mm FRLH/S in and including PVC concealed 20/25 mm dia medium duty ISI marked with all necessary fittings for mounting of modular switches/sockets including 1.5 sq mm FRLH/S PVC insulated unsheathed stranded copper conductor as earth lead and connected to common earth doly for one light / ceiling fan/exhaust fan controlled by one switch complete including cutting, chasing the surface and then making good the same in CM 1:3 complete all as specified and directed by Engr- in-charge. |
| 45 | All as per item No. 44 above but 3 pin 5 amps socket out let point with the same board with other switches with cables of 1.5 Sqmm size |
| 46 | All as per item No. 44 above but for one 5 amp socket on independent board with cables of 1.5 sqmm size |
| 47 | All as per item No. 44 here-in-before but using 2.5 sq mm size stranded copper conductor cable for one 16 amp switch socket outlet on independent board including 2.5 sq mm FRLH/S PVC insulated unsheathed stranded copper conductor as earth lead complete all as specified and directed by Engr-in-charge. |
| 48 | S&F sunken flush metal GI boxes for fixing of modular switches/sockets flush to the walls complete for 2 modules. of Make : Havells or equivalent in legrand |
| 49 | -do- all as per item No 48 above but for 3 modules of Make : Havells or equivalent in legrand |
| 50 | -do- all as per item No 48 above but for 4 modules of Make : Havells or equivalent in legrand |
| 51 | S&F modular cover plate with frame for fixing of modular switches/sockets complete for 2 modules of Make : Havells or equivalent in legrand ( Note switch and sockets will be measured and paid separately) |
| 52 | -do- all as per item No. 51 above but for 3 modules of Make : Havells or equivalent in legrand |
| 53 | -do- all as per item No. 51 above but for 4 modules of Make : Havells or equivalent in legrand |
| 54 | S&F switch piano modular flush type 5/6 Amps 230V AC complete one way Make : Havells or equivalent in legrand |
| 55 | M&L for modular switch socket combination outlet 3 pin 5 Amps 230 volts flush type. |
| 56 | S&F modular socket out let 3 pin 5 Amps flush type. |
| 57 | S&F modular switch socket outlet multipurpose 3 pin 15 Amps and one pin 5 Amps controlled by one switch. |
| 58 | S& F modular electronic step type fan regulator by step type 230 volt. |
| 59 | S & F Ceiling rose, 3 phase/PVC/ polycarbonate, isolated body all as specified and directed by engineer in charge |
| 60 | S & F surface and wall mounted LED batten 4feets with 1x20W indoor decorative luminaries with and including electronic driver and 1x20W LED lamp,pre wired including necessary electric connection copper flexible PVC cable of 0.5 sqmm 3 core not more than 1m in length from ceiling rose to light fittings including taking down unserviceable fittings.Make: Magik Cat No. BWPP020C or Philips cat no. BN021CLED22SPSUCWGR or equivalent in Bajaj/Havells |
| 61 | Supply and fixing LED luminaire 600 mm x 600 mm, 35/36 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete. |
| 62 | Taking down U/S DB,MCB, all as specified and directed by engineer in charge. |
| 63 | S&F sheet metal enclosure for DB's when MCBs to be used 8 way single pole and neutral double door with 200 amps rated bus bar complete including connection all as specified. |
| 64 | S&F MCB 6 to 32 amps single pole complete all as specified. |
| 65 | S&F MCB DP 63 amps 240 volts 10KA breaking capacity complete all as specified. Make legrand Cat part No. : 406502 |
| 66 | Taking down U/S sub main wiring all as specified and directed by engineer in charge. |
| 67 | S&F sub main wiring two run of single core PVC insulated unsheathed stranded copper conductor of size 4 sqmm & one run of PVC insulated unsheathed stranded copper conductor of size 4 sqmm as earth lead drawing into rigid non metalic PVC conduit of size 20 mm dia including taking down old unsv. Note: Three run of 4 sqmm cable will be measured as single length. |
| 68 | All as per item No. 67 but with three run of single core 6 sqmm cable complete |
| 69 | Cutting chases, pinning in, making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc.; and cutting chases for concealed water tubing or concealed conduit wiring, etc. and making good, cutting exceeding 20cm girth all as specified and directed by Engineer-in-charge. Please Enable Macros to View BoQ information |