| 1 | (B/R PORTION)Taking down cement plaster on brick or stone walls, etc. including racking out joints, hacking for key, scrubbing down with water, etc complete all as specified and directed. |
| 2 | M&L rendering 15 mm thick cement plaster in two layer each of 10+5 mm thick on fair face of brick work or concrete surface in CM (1:4) & water proofing compound mixed with second layer @200 ml/Bags finished fair and even. complete all as specified and directed. ( Note -W.P.C. shall be measured and paid separetly . ) |
| 3 | M&L for 15mm thick rendering on fair faces of brick work or concrete surfaces in CM 1:6 finished rendering surfaces even and smooth (without using extra cement) complete all as specified and directed |
| 4 | M&L rendering 10 mm thick in CM 1:3 on concrete as in ceiling/landing etc on concrete surface finish even and smooth without using extra cement with and including taking down cement or lime plaster of any description complete all as specified and directed. |
| 5 | Supplying Integral water proofing compound. |
| 6 | Demolition of brick work built in cement mortar including all quoins, arches, pillars etc complete all as specified and directed. |
| 7 | M&L brick work with Fly ash bricks old size brick straight or curved on plan exc 6 m mean radius built in cement mortar 1:6 complete all as specified and directed. |
| 8 | M&L brick work with Fly ash bricks' old size brick straight or curved on plan to any radius built in cement mortar 1:4 as in half brick thick wall complete all as specified and directed. |
| 9 | M&L for 15mm thick cement plaster in cement mortar 1:4 on bricks or concrete surface and finished even and smooth without using extra cement including necessary scaffolding workall as specified and directed . |
| 10 | M & L two coat of oil bound distemper on newly plastered surface of wall, by brush and roller including over of one coat primer on wall complete all as directed . |
| 11 | M/L for complete removal of existing treatment, washing, rubbing down and stopping of painted/treated surfaces and applying two coat of oil bound distemper by brush and roller including over one coat of primer on wall complete all as directed . |
| 12 | M&L for applying two coats of oil bound distemper to old decorated surfaces of ceiling including preparation of surface (by brooming down or steel wire brushing, scrapping down smoke, soot, moulds, moss, efflorescent salts, trading oil and greasy spots) complete all as specified and directed. |
| 13 | M&L for applying two coats of oil bound distemper to new surfaces of ceiling including preparation of surface complete all as specified and directed. |
| 14 | M & L Preparation of new plastered surfaces of walls and soffits of Chajja, roof slab etc and applying two coat of weather proof exterir emulsion paint of approved make using airless sprey technology capable of operating single spray gun with hose of adequate length and necessary scaffolding for building hight complete all as spcified and directed. |
| 15 | M & L Preparation of old treated/ painted surfaces of walls and soffits of Chajja, roof slab etc, by cleaning brooming, rubbing and scrapping as required using broom, emery paper, putty blade/ scraper as applicable to make the surface free from loose paint, algae formation dust etc including necessary safety & protective measures such as safety belt, headgear etc including filling cracks upto 5mm with and including suitable elastomeric crackfill paste and applying two coat of weather proof exterir emulsion paint of approved make using airless sprey technology capable of operating single spray gun with hose of adequate length and necessary scaffolding for building hight complete all as spcified and directed. |
| 16 | M & L preparation applying one coats of synthetic enamel paint on old steel serface of any description over 10 cm width or girth complete all as specified and directed. |
| 17 | Dismantling stone slabs and tiles of any description or thickness in floors, aprons etc laid bedded and pointed in any mortar complete all as specified and directed |
| 18 | M & L 40 mm thick PCC 1:2:4 type B-1 using 20 mm graded stone aggregate as in flooring, laid in alternate bays, surface finished even and smooth using without extra cement complete all as specified and directed. |
| 19 | M & L 18 to 20 mm thick machine cut Pre Polished Kota stone slab flooring ,stair case step etc over screed bed base ,laid and jointed with grey cement slurry mixed with pigment to match with shade of slab including rubbing and polishing icluding 15 mm thick screed bed in cement mortor 1:6 complete all as specified and directed. |
| 20 | M & L 18 to 20 mm thick machine cut Pre Polished Kota stone in riser of steps, skirting, dado and piller laid and jointed with grey cement slurry mixed with pigment to match with shade of slab including rubbing and polishing with & including 10 mm thick rendering in cement mortor 1:4 complete all as specified and directed. |
| 21 | S&F Machine pressed precast concrete interlocking paver block any shape and size with grey cement with pigment confirming to IS 15658-2006 of 60 mm thickness, M-35 Grade all as specified and directed. |
| 22 | S&F powder coated (minimum thickness of powder coating 50 micron) anodised aluminium doors frame for doors, windows, ventilators with one or more rebates including joining cleat for fixing etc complete all as specified and directed. |
| 23 | S&F, Powder coated aluminium Three Track sliding window with shutter styles 40mm x20 mm sheet thickness 1.5mm Two shutter of glass and one shutter of wire mesh consisiting of Stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples, frame (chowkat) of window shall 100mm x 44mm x 1.5mm thick section with or without rebate 5 mm thick tinted glass fixed with aluminium beads locking arrangement with each shutter all as directed by the Engineer-in-Charge.Note: 1) Size of window shall be as per site requirement. 2) Glass and wire cloth shall be inclusive in this Rate. |
| 24 | S &F framed work such as grills, grating etc with ends of bars shouldered and or riveted or forged into spikes, framed guard bars, barried iron doors ladders framed balusters, walk ways, railing framedwork of water tanks and similar work conforming to Fe.290 Gde E-165 complete. |
| 25 | M & L applying two coats of synthetic enamel paint on steel surfaces of any description/new over 10 cm width or girth over a coat of red oxide primer including preparation of surfaces complete. |
| 26 | Dismantling Structural steel wok incl grills ,gates, stair case etc but excluding framed truss in any postion complete all as specified and directed. |
| 27 | S&F rolled mild steel in roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc of Fe-410-W(Gde-E-250) quality-A complete all as specified and directed |
| 28 | S&F 1.0 mm thick laths Steel rolling shutters, with out ball bearing, as specified including top cover, anchoring rod, hasp and staple and one shop coat of primer;erected in position as indicated, complete: push pull or manual type all as specified |
| 29 | S&F Safety lever locks mild steel with 4 levers for rollingshutters all as specified |
| 30 | S&F Ball bearing for rolling shutters all as specified |
| 31 | S&F mild steel Framed work as in doors or sliding gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or othercovering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering,running rails and guides) and hanging; also fastening and fixing complete Fe-410-W(Gde-E-250) quality-A all as specjfied and directed. |
| 32 | S&F 0.8-0.9 mm thickMild steel, plain, black sheet in wall cladding, steel gates and similar work, cut to size, holes punched; including round headed screws, clout nails or rivets and fixed to wood or steel framing with plain 40 mm lap joints with riveted or welded seams, including bending or turning up, mitred angles, etc. as required all as specified and directed. |
| 33 | Demolition of cement concrete (un-reinforced) not exc and out compete existing roof treatment from roof surface & roughening of old concrete floor surfaces including cleaning the roof surfaces by brushing sweeping etc and removing rubbish material complete all as specified and directed. |
| 34 | M & L for rendering 10mm thick on fair faces of concrete surfaces in cement mortar 1: 4 under APP membrane finish rendering surfaces even and smooth with out using extra cement mixed with WPC @2% by weight of cement or as per manufacturer instruction. Complete all as specified and directed (Note:- WPC shall be mesured and paid separately) |
| 35 | M&L for providing 25mm thick PCC (1:2:4) type 'B-0' (using 12.5mm graded crushed stone aggregate) after applying cement slurry @ 3 Kg/sqm, on top of roof, mixed with water proofing compound @ 200 ml per bag of cement, surface finished even and smooth without using extra cement including complete all as a specified and as directed. |
| 36 | M & L for cutting Grooves in brick wall, 75mm wide and 65mm deep and shaping horizontal face of groove with cement mortar 1:3 or cement concrete 1:2:4 type-B1 as required complete all as a specified and as directed.. |
| 37 | M & L for brushing neat cement slurry with 3.0 Kg of cement per Sqm complete all as a specified and as directed. |
| 38 | M & L for for water proofing treatment on existing cleaned RCC roof with the following specification and manufacturings instruction complete all as specified and as directed:-(a) Preparing and clening of fully dry surfaces as per IS3067-1966(b) Applying bitumen primer conforming to IS:3384-1968 over the cleaned plaster surface @ 0.5 Ltr per sqm(c) Applying a layer of APP based polymeric membrance 3.0mm thick (minimum) weight 3.0Kg per sqm (reinforced) with polyster Non woven fabric weighing not less than 160gms per sqm by torch application.The over laps shall be minimum 100mm on the transverse direction and 75 mm on longitudinal direction.(d) Applying one coat of aluminium paint @0.10 ltr per sqm over APP based polymeric membrane. |
| 39 | Demolition of cement concrete (un-reinforced) not exc 15cm thick in ground floor and paving (below or above ground level) complete all as specified and directed. |
| 40 | M&L 75mm thick PCC 1:3:6 type C-1 using 20 mm graded stone aggregate as in plinth protection or similar places, laid in alternate bays, surface finished even and fair without using extra cement complete all as specified and directed. |
| 41 | Excavating in post holes (or similar holes) each n exc 0.5 cu. m, getting out, returning, filling in & raming earth/ broken rubble mixed with earth around, in layers n. exc. 25cm, watering, & removing surplus soil to a distance n exc 50m & making good surface in soft/loose soil. |
| 42 | Surface excavation n.exc 30cm deep & averaging 15cm deep and getting out in soft / loose soil complete all as specified and as directed. |
| 43 | Removing excavated material exc.250 m but n.exc.500 m and depositing where directed. |
| 44 | M & L for plain cement concrete type B-2, 1:2:4 (using 40 mm graded granite stone aggregate) in foundations, filling and mass concrete complete all as specified and directed |
| 45 | M&L for hard core of gauge n exc 63 mm, deposited spread and levelled in layers n exc 15 cm thick, watered and rammed to a true surface using broken stone or boulders complete all as specified and as directed. |
| 46 | M&L Steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I. S.1161- 1979 grade St.-240 complete all as specified and directed by Engineer-in-Charge. |
| 47 | S&F for plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, without any attachment of grade Fe-410- W(Gde- E-250) quality- B complete all as specified and directed |
| 48 | M&L Preparing new Steel or Iron Surfaces of any description, over 10 Cm width or girth and applying Two Coats of Synthetic Enamel Paint over a coat of Red Oxide/ Zinc Chrome Primer, complete all as specified and as directed. |
| 49 | M&L Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified. |
| 50 | M&L Pre- painted galvalume aluminum zinc coating GI based plain steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified. |
| 51 | Providing and laying at or near ground level factory made kerb stone of M-25 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement: 3 coarse sand), including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5 mm), including making drainage opening wherever required complete all as specified and directed. |
| 52 | M&L for 100 mm thick PCC 1:3:6 type C-2 40mm graded aggregate finished complete all as specified and as directed. |
| 53 | Providing PCC (1:3:6) type C-2 as in surface channels and drains including necessary from work complete all as specified and directed. |
| 54 | Forming fair finished drain or channel any inner girth in cement concrete, using extra cement, including forms, mould, mitred/stopped ends etc complete all as specified and directed |
| 55 | Add or deduct for 25mm girth or part there of over or under 30cm girth in cement concrete, using extra cement, including forms, mould, mitred / stopped ends etc complete all as specified and directed |
| 56 | M&L Providing precast reinforced cement concrete RCPC drainn cover 75 mm thick of size 600mm x 450 mm as in drain cover with capcity 3MT complete all as specified and directed |
| 57 | S&F 15 mm thick pre-polished decorative cement concrete tunnel wall tiles (brick tiles) of approved of any size, design and colour laid on any type of vertical surfaces i.e. straight / curved over 15mm thick backing layer in cement mortar (1:4) set and jointed in neat cement slurry and pointed in white cement mixed with admixture of pigment to match the shade complete all as specified and as directed. |
| 58 | Material and Labour for applying 2.0 mm thick wall care putty on old / new surface of wall ( Straight or curved) and complete all as directed. |
| 59 | Material & Labour preparation of old surfaces and applying one coat of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over old surface of approved make using airless spray technology capable of operating single spray gun with hose of adequate length and necessary scaffolding for any height of the building complete all as specified and directed. |
| 60 | Material & Labour for complete removal of existing treatment and applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre / 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over old surface surfaces of approved make using airless spray technology capable of operating single spray gun with hose of adequate length and necessary scaffolding for any height of the building complete all as specified and directed. |
| 61 | Material & Labour for applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surface of approved make using airless spray technology capable of operating single spray gun with hose of adequate length and necessary scaffolding for any height of the building complete all as specified and directed. |
| 62 | M&L for preparation of old surface and Finishing walls with textured exterior paint of required shade : New work (Two or more coats applied @ 3.28 ltr /10 sqm) over and including priming coat of exterior primer applied @ 2.20 kg /10 sqm in any design any shape as required complete all as specified and as directed. |
| 63 | M&L Preparing old Steel Surfaces of any description not otherwise decribed over 10 Cm width or girth and applying One Coat of Synthetic Enamel Paint, complete all as specified and as directed. |
| 64 | Taking down chowkhat or frames with shutters (without taking off shutters from the frame) area exc 1.5 Sqm and n.exc.4.00 Sqm each wooden all as directed. |
| 65 | Taking down chowkhat or frames with shutters (without taking off shutters from the frame) area n.exc. 1.5 Sqm each all as directed. |
| 66 | S&F 4.00 mm Sheet ordinary quality and glazing with oil putty in square in each pane thick in door , partition , windows and similar work including cutting to shape , drilling holes as required complete all as specified and as directed. |
| 67 | S&F for Framed work as in doors or gates of angle or other sectionwith gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing complete all as specified and directed |
| 68 | S&F for 1.60 mm thick Mild steel, plain, black sheet in wall cladding, steel gates and similar work, cut to size, holes punched; including round headed screws, clout nails or rivets and fixed to wood or steel framing with plain 40 mm lap joints with riveted or welded seams, includingbending or turning up, mitred angles, etc. a complete all as specified and directed |
| 69 | Cutting holes in brick walls upto one brick in lime or cement mortar for inserting holdfasts and making good dismantled portion in cement mortar 1:3 or cement concrete 1:2:4 Type B-1 as required |
| 70 | S&F holdfast/sliding bolts for doors and windows including bolts, if required: hooks (stay), heavy, for large gates; hook and pintle hinges: large hasps and staples; chains; hand made sliding bolts; clamps; hold fasts; wall ties; hooks for hanging fans; plain angle cleats for securing purlins to wood trusses or rafters; knee piece inserts; two way and three way straps, plate washers and similar small articles conforming to Fe-290 Gde-E-165 complete all as specified and directed |
| 71 | S&F Steel windows with side hung shutters including projecting type hinges with steel handle, and steel peg stay, complete with glazing bars, dovetailed or welded . |
| 72 | Demolition of stone slabs , floor and wall tiles of any description or thickness in floors/vertical surfaces, etc laid, bedded and pointed in any mortar, etc complete all as specifed and directed by Engineer-in-charge. |
| 73 | S&F 8-10 mm thick Virified exterior grade full body colour tiles of size 300 x 300 / 400 x 400 mm in floors/ skirting etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over 15 mm thick backing layer in cement mortar (1:4) mixed with admixture of pigment to match the shade complete all as specified and as directed. |
| 74 | Supply and fixing of unplasticized (uPVC) of type-A for use in ventilation pipe work and rain water and rain water harvesting, single socket, 110 mm bore in any length including rubber ring joints and fixed to wall with clips, otherstandered material and including taking down old 110 mm dia CI rain water pipe & removed from site all as specified in IS 13592 upto 4 storey building height including necessary scaffolding, safety and protective measures complete all as specified and directed. |
| 75 | Excavation in trenches, not exceeding 1.5 M wide and not exceeding 1.5 M depth for foundation, etc. and getting out in soft/ loose soil. |
| 76 | Returning,filling in, including,spreading,levelling,watering and well ramming in layers not exc. 25cm in soft loose soil complete all as specified and directed. |
| 77 | M & L for plain cement concrete type E-2, 1:5:10 (using 40 mm graded granite stone aggregate) in foundations, filling and mass concrete complete all as specified and directed. |
| 78 | material and labour for applying two coats of synthetic enamel paint on steel & iron surfaces of any description, n exc 10cm width or girth when unconnected with other painting or when painted in different tint, including preparation of new surface & applying one coat of red oxide, zinc chrome complete all as specified and directed |
| 79 | (E/M PORTION)Taking down copper/ aluminium point wiring (light, fan, buzzer, socket or power) complete including fixture and fittings such as switches, ceilling roses, pendants , regulators, sockets etc excluding light fitting for taking credit removing from site and making good disturbed surface of walls, floors etc complete all as specified and directed Please Enable Macros to View BoQ information |
| 80 | (E/M PORTION)Taking down copper/ aluminium point wiring (light, fan, buzzer, socket or power) complete including fixture and fittings such as switches, ceilling roses, pendants , regulators, sockets etc excluding light fitting for taking credit removing from site and making good disturbed surface of walls, floors etc complete all as specified and directed Please Enable Macros to View BoQ information |