| 1 | Earth work in excavation of foundation trenches or drains, in all sorts of soil (including mixed soil but excluding laterite or sandstone) including removing, spreading or stacking the spoils within a lead of 75 m. as directed. The item includes necessary trimming the sides of trenches, leveling, dressing and ramming the bottom, bailing out water as required complete. depth of excavation not exceeding 1.50 mt |
| 2 | Laying Stone Boulder soling 150 mm thick to proper camber hand packing etc complete as dsirected |
| 3 | Earth work in filling in foundation trenches or Plinth with ngood earth in layer not exceeding 150mm incl. watering and ramming cvomplete with earth obtained from excavation of foundation |
| 4 | Earth work in filling in foundation trenches plinth incl. watering ramming completeas directed with carried earth (arrange by the contractotr) |
| 5 | Cement concrete ( 1:3:6 ) with 30 mm. down graded shingles excluding shuttering with NB variety |
| 6 | Ordinary mix M-15 cement concrete with graded stone chips (20 mm size) excl. shuttering and reinforcement, if any, in G.F.. Proportion (1:1.5: 3). |
| 7 | Reinforcement for reinforced concrete work in all sorts of structures including distribution bars, stirrups, binders etc. including supply of rods, initial straightening and removal loose rust (if necessary), cutting to requisite length, hooking and bending to correct shape, placing in proper position and binding with 16 gauge black annealed wire at every inter-section, complete as per drawing and direction. Tor steel GF |
| 8 | Hire and labour charges for shuttering with centering and necessary staging upto 4 m. using approved stout props and thick hard wood planks of approved thickness with required bracing for concrete slabs, beams, columns, lintels and striking out after completion of works (at foundation upto plinth) without staging. |
| 9 | Hire and labour charges for shuttering with centering and necessary staging upto 4 m. using approved stout props and thick hard wood planks of approved thickness with required bracing for concrete slabs, beams, columns, lintels curved or straight including fitting, fixing and striking out after completion of works (from plinth upto roof of ground floor). |
| 10 | 125mm thick brick work in cement mortar ( 4:1 ) in ground floor |
| 11 | Plaster with sand cement morter incl. rounding off corner or chamfering corners as directedand racking out joints and drip course with 4:1 cement mporter 15 mm thick |
| 12 | Plaster with sand cement morter incl. rounding off corner or chamfering corners as directedand racking out joints and drip course with 4:1 cement mporter 10 mm thick GF |
| 13 | Neat cement bpunning with 1.5 mm thick in wall dado window sill ffloor drain as directed |
| 14 | Wood work in door window frames fine dressed fitted and fixed in position complete. as per design including making plaster where directed. |
| 15 | Pannel shutters of doors and windows, as per design including fitting fixing shutters in position but excluding the cost of hinges and other fittings.35 mmthick shutter with 19mm thick panel ( Black Siris, panisas) |
| 16 | Shutter of 1/3rd panel, 2/3 glazed of doors and windows, as per design (each panel consisting of a single plank without joint and with ordinary glass of 7.4 kg per Sq.m/3mm Thick) fitted with putty bed, teak wood bead and nails including fitting and fixing shutters in position |
| 17 | Grey artificial stone in floor, skirting dado, stair case etc with cement concrete(4:2!:1) with stone chips laid in panels with 3 mm thick topping complete as directed. |
| 18 | Supply fitting and fixing 1st quality vitrified tiles in wall and floors to match with the existing work with cement morter as directed and araldite at the back of each tile and finishing the joints with while cement mixed with colouringt oxide if required(600x600) |
| 19 | M.S clamp for fixing door and window frames made of M.S flat and bifurcated fixed in cement concrete with stone aggregate ( 4:2:1 ) fitted and fixed as per direction including cost of concrete. © 40 mm. x 6 mm. flat. 25 cm long. |
| 20 | Supply fittingfixing Iron butt hinges fitted fixed completed as per PWD schedule at Floor |
| 21 | Supplying Iron hasp bolt fitted fixed complete incl. fitting fixing complete) |
| 22 | Anodised aluminium door handle of approved quality fitted and fixed complete. ( bow or D type. ) b)150 mm. size x 6 mm |
| 23 | MS srructural works in roof trusses e=with tubelar section connected to one another with bracket gusset cleats as per design as directed. |
| 24 | Galvanised corrugated iron sheet work fitted fixed with point welding for Door window as directed as per PWD schedule |
| 25 | Galvanised corrugated iron ridging work fitted fixed with point welding for Door window as directed as per PWD schedule |
| 26 | MS ornamental grill of appvd design joints continously welded with ms flat of window railing etc as directed. ( up to 16 kg/m2- 20 kh/m2)) |
| 27 | collapsable gate fitting fixing as per PWD schedule |
| 28 | Priming one coat on timber , plaster or steel surface, with ready mixed primer of approved quality, including smoothening surfaces by sand papering etc.on wooden surface |
| 29 | Priming one coat on timber , plaster or steel surface, with ready mixed primer of approved quality, including smoothening surfaces by sand papering etc.on steel surface |
| 30 | Painting ( any shade as directed ) with ready mixed oil bound paintor super gloss synthetic enamel ( hi-gloss ) paint of approved make and brand ( except red lead paint , aluminum paint and black Japan ) including smoothening surface by sand papering etc. on wooden surface |
| 31 | Painting ( any shade as directed ) with ready mixed oil bound paintor super gloss synthetic enamel ( hi-gloss ) paint of approved make and brand ( except red lead paint , aluminum paint and black Japan ) including smoothening surface by sand papering etc. on steel surface |
| 32 | Protective and Decorative Acrylic exterior emulsion paint of approved quality, as per manufacturer's specification and to be applied over acrylic primer as required. The rate includes cost of material, labour complete (premium quality) at Ground floor |
| 33 | Applying Exterior grade Acrylic primer of approved quality and brand on plastered or cencrete surface old or new surface to receive decorative textured (matt finish) or smooth finish acrylic exterior emulsion paint including scraping and preparing the surface throughly, complete as per manufacturer's specification and as directed at GF |
| 34 | Acrylic Distemper to interior wall, ceiling with a coat of solvent based interior grade acrylic primer (as per manufacturer's specification) including cleaning and smoothning of surface. Two Coat (all floor) |
| 35 | Supplying fitting fixing 1st quality ceramic tiles in walls and floors to match with the existing work as per PWD schedule wall |
| 36 | Supplying fitting fixing 1st quality ceramic tiles in walls and floors to match with the existing work as per PWD schedule floor |
| 37 | Supplying fitting fixing PVC pipe Exposed work as directed 15 mm dia |
| 38 | Supplying fitting fixing PVC pipe Exposed work as directed 25 mm dia |
| 39 | Wash basin white vetrious china best quality approved make(without fittings) supplied fitted and fixed complete in position on 75 mmx75mmx75mm (550x450) |
| 40 | Supplying fitting fixing wheel valve of approved make and brand as directed. |
| 41 | Supplying fitting fixing bib cock, piller cock etc of approved quality as directed. |
| 42 | Supplying fitting fixing stop cock conforming IS code as directed |
| 43 | Supplying fitting fixing orrisa type w.c. in white glazed virtreous chinawire of approved quality in position as directed |
| 44 | Supplying Water Storage Tank of approved Tank as directed 1000 lit |
| 45 | Construction of Inspection pit 600x600 with brick work incl. rcc at top |
| 46 | Constructing of Circular soak well 2.50 mt deep in all types of sandy soil with dry brick work up to 1.60 mt from the bottom having 150 mm intermediatete cement brick work(6:1) up to 0.90 mt from with 19 mm thick cement plaster(4:1) to inside face up to depth of cement brick work 12 mm thick cement plaster( 4:1) on outer face from the top of the wallup mto GLand 6mm thick cement plaster(4:1)on the top of the RCC cover slab incl. filling bottom 1.00 mt of inside of the wall with brick metal incl. Rcc cover slab of designed thickness with cement concrete (4:2:1) with stonechips including necessary re-inforcement and shuttering incl. one 560 mm dia RCC manhole cover of appvd.make supplied fitted fixed in the cover slab with necessary fitting making necessary arrangement for pipe connection excavation of well incl. shoring dewatering and removing the excessearth from the premisses as per direction complete in all respect with all costs of labour & materials .with 250 mm thick dry brick and 250 mm cement brick work(6:1) and 1.00 mt inside dia |
| 47 | Construction of Septic Tank of different capacities as per approved drawing with 1stclass brickwork in cement morter (4:1) including two 560mm dia. RCC manhole cover of approved make supplied, fitted & fixed in the top slab with necessary fittings, 19mm thick cement plaster (4:1) with neat cement finish to the internal surfaces and 12mm thick plaster (4:1) to out side wall upto 200mm below GL, floor finished with 25mm thick grey artificial stone including supplying, fitting & fixing all necessary specials, fittings, SW tees, CI foot rest etc. including excavating earth in all sorts of soil, shoring, bailing & pumping out water as necessary, ramming, dressing the bed & refilling the sides of the tank with earth, removing spoils, filling up the chamber with clear water, removing foreign materials from the chamber & including constructing attached inspection pit as per approved drawing & connecting all necessary pipes, joints etc. with internal plaster work & artificial stone flooring is to be done with admixture of water proofing compound @ 5% by weight of cement, complete in all respect as per direction of Engineer-in-charge. |
| 48 | Supplying fitting fixing 10 liter PVC low down Cistern of approved quality in position as directed |
| 49 | PVC False Ceiling- Providing false ceiling made with frame work 0f steel tube of 40x20 mm , 18 gauge fitted 1000mm to 12mm apart the entire frame workwill be fixed in wallands PVC sheet fixed into the franme work as per PWD schedule completed as directed |
| 50 | Supply fitting fixing Auditorium Chair of approved quality as directed ( rate approved after quotation taken from dealers) VIP |
| 51 | Supply fitting fixing Auditorium Chair of approved quality as directed ( rate approved after quotation taken from dealers) |
| 52 | Electrification work as per requirement as per PWD schedule as directed ( Payment to be made item wise as per measurement) |
| 53 | Total |
| 54 | GST 18% |
| 55 | Labour Cess 1 % Please Enable Macros to View BoQ information |