| Sl. No. | Item Description |
| 1 | Preparation of old treated surfaces of walls by brooming down or steel wire brushing and M&L for applying one coat of white wash complete all as specified and directed. |
| 2 | All as per BOQ Serial item No 1 above but on ceilings complete all as specified and directed. |
| 3 | Preparation of old plastered surfaces of walls and M&L for applying two coats of white wash complete all as specified and as directed. |
| 4 | All as per BOQ Serial item No 3 above but on ceilings complete all as specified and directed. |
| 5 | Preparation of old plastered surfaces of walls and M&L for applying one coat of acrylic washable distemper complete all as specified and as directed. |
| 6 | Preparation of old plastered surfaces of walls and M&L for applying two coats of acrylic washable distemper complete all as specified and as directed. |
| 7 | Complete removal of existing treatment of walls; preparatory to distempering, priming plastered and other surfaces with chalk whiting and M&L for applying two coats of OBD complete all as specified and as directed. |
| 8 | All as per BOQ Serial item No 7 above but on ceilings surfaces complete all as specified and as directed. |
| 9 | M&L for applying 2mm thick wall care putty on walls/ceilings complete all as specified and as directed. |
| 10 | Preparation of old treated/decorative surfaces of walls by washing, rubbing down and stopping old painted surface and M&L for applying one coat of cement base paint complete all as specified and as directed. |
| 11 | M&L for applying one coat of weather proof exterior emulsion paint over & including a coat of primer on old decorated surface of external walls including preparation of surfaces to remove all foreign materials including necessary working platform/scaffoldings to work at heights upto 12 stories complete all as specified and as directed. |
| 12 | Preparation of old treated/decorative surfaces of walls by washing, rubbing down and stopping old painted surface and M&L for applying two coats of cement base paint etc complete all as specified and as directed. |
| 13 | Preparation of old surface include brooming down or steel wire rushing; scrapping down smoke soot, moulds, moss and efflorescent salts and trading oil and greasy spots of old surface of floor tiles/paver block and M&L for applying one coat of floor guard paint etc complete all as specified and as directed. |
| 14 | Preparation of old surface include brooming down or steel wire rushing; scrapping down smoke soot, moulds, moss and efflorescent salts and trading oil and greasy spots of old surface of floor tiles/paver block and M&L for applying two coats of floor guard paint etc complete all as specified and as directed. |
| 15 | Preparation of old painted surfaces of wood and wood based surfaces of any description over 10 cm width or girth and M&L for applying one coat of synthetic enamel paint complete all as specified and directed. |
| 16 | All as per BOQ Serial item No 15 above but two coats of synthetic enamel paint complete all as specified and as directed. |
| 17 | Preparation of old painted surfaces of steel & iron of any description over 10cm width or girth and M&L for applying one coat of synthetic enamel paint etc complete all as specified and as directed. |
| 18 | Preparation of old painted steel surfaces of any description over 10 cm width or girth and M&L for applying two coats of synthetic enamel paint complete all as specified and as directed. |
| 19 | Preparation of old painted surfaces on walls of any description over 10 cm width or girth and M&L for applying one coat of synthetic enamel paint on wall surface complete all as specified and as directed. |
| 20 | M&L for french polishing on surfaces of any description width or girth including cleaning and preparing the surfaceover & including a coat of wood filler on old works with one or more coats complete all as specified and as directed. |
| 21 | Complete removal of existing treatment of wall surfaces and M&L for applying multi colour texture with plastic paint to match existing design and pattern as approved complete all as specified and directed.Note: Work shall be done in bldgs with height upto 12 storey. |
| 22 | M&L for one coat of plastic paint over old texture sruface to match existing design and pattern as approved complete all as specified and directed.Note: Work shall be carried out to bldgs with height upto 12 storey. |
| 23 | Demolition of cement concrete of any description and in any position not other wise specifically provided for including removal of all debris outside MoD land complete all as specified and directed.Note: Work shall be carried out to bldgs with height upto 4 storey. |
| 24 | M&L for PCC 1:5:10 Type E2 (using 40mm graded crushed stone aggregate) as in filling sunken floors, etc complete all as specified and as directed. |
| 25 | M&L for 25mm thick PCC 1:2:4 Type B-1 (using 20 mm graded crushed stone aggregate) as in sub base of floor, etc complete all as specified and as directed. |
| 26 | Supply and applying two coats of High performance elastomeric cementitious waterproof coating sandwiched with 45 GSM glass fibre reinforcement on the entire floor and 1.0 m of all walls of all toilets as per following methodology:- Cleaning of exposed concrete surface by mechanical means or by hydro blasting to remove laitance, loose particles, contamination etc. which may hinder bonding. Coving of RCC joints with PCC (1:1.5:3) mixed with Integral Water Proofing compound. Applying one coat of Waterproofing membrane to concrete surfaces followed by application of 45GSM glass fibre on the wet surface. Applying second coat of waterproofing membrane at the right angles to the direction of first coat. Second coat shall be applied after the first coat gets dry. Sprinkling fine aggregate immediately after the application of second coat to get the mechanical key for protective plaster. Curing to Water proofing membrane to be carried out for minimum period of 3 days with ponding complete. The Water Proofing Product Should have Mixed density: 1.68g/cc (brushable consistency). Adhesion to concrete : >1N/mm2. Static crack accommodation: 1mm.complete all as specified and directed. Make :- Fosroc/Elantas beck/Kunal conchem or equivalent as approved by GE. Note: Work shall be carried out to bldgs with height upto 12 storey. |
| 27 | Supplying and laying for 40 mm outer dia of CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings in trenches/walls including all brass fitting/fixtures in any grade to receive plumbing fittings and fixtures complete all as specified and directed |
| 28 | S&F solid PVC door frame of size 50 mm x 47 mm made out of 5 mm single side prelam PVC sheet used instead of plain colour PVC sheet & edges will be painted to match,reinforced with MS Sq tube in opening all as shown on drawing complete all as specified and directed.Note: Work shall be carried out to bldgs with height upto 12 storey. |
| 29 | S&F for factory made solid PVC Moulded door shutter 28 to 30 mm thick (stiles) with 2 mm thick prelaminated Moulded PVC sheet polyurethane painted on the front face & 2 mm plain colour PVC sheet on back faces, and with particle board core supplying and fixing in frame at site as per specification complete all as specified and directed.Note: Work shall be carried out to bldgs with height upto 12 storey. |
| 30 | Taking down cement plaster of any description on Brick/stone wall including racking out joints, hacking for key scrubbing down with water, including removal of all debris outside MoD land complete all as specified and directed. |
| 31 | M&L for rendering 10 mm thick in CM (1:6) on brick/concrete sufaces, plastered surface finished even and Smooth without using extra cement complete all as specified and as directed. |
| 32 | M&L for 10mm thick rendering in cement mortar (1:3) on concrete surface as in ceiling and finished the surface even and smooth without using extra cement complete all as specified and as directed. |
| 33 | M&L for rendering 15 mm thick in CM (1:4) on brick/concrete sufaces, plastered surface finished even and Smooth without using extra cement complete all as specified and as directed. |
| 34 | Supply only liquid water proofing compound complete all as specified and directed. |
| 35 | Preparation of newly plaster surfaces of wall and M&L for applying two coats of Acrylic washable distemper over & including a coat of primer complete all as specified and directed. |
| 36 | Preparation of new decorated surfaces and M&L for applying two coats of exterior acrylic emulsion painting over & including a coat on walls complete all as specified & directed. |
| 37 | Preparation of new plaster surface of walls and M&L for applying two coats of cement base paint etc over & including Chalk whiting complete all as specified and directed. |
| 38 | Preparation of newly plaster surfaces of ceiling surfaces and M&L for applying three coats white wash on walls complete all as specified and directed. |
| 39 | Preparation of old surfaces of wall and M&L for applying one coat exterior acrylic emulsion paint on external surface incl nescessary scafolding complete all as specified and directed. |
| 40 | Preparation of old surfaces of wall and M&L for applying two coats exterior acrylic emulsion paint on external surface inclulding nescessary scafolding complete all as specified and directed. |
| 41 | Supply only integral water proofing compound complete all as specified and directed. |
| 42 | Taking down shutters of any description area exc. 1 sqm and n. exc. 2 sqm and resecuring or easing & adjusting and refixing in same opening complete all as specified and directed. |
| 43 | Taking down shutters of any description area n exc. 1 sqm each and resecuring or easing & adjusting and refixing in same opening complete all as specified and directed. |
| 44 | Taking down chowkats or frames with shutters (without taking off shutters from the frames) area exceeding 1.5 sqm but not exceeding 4 sqm each complete all as specified and directed. |
| 45 | All as per BOQ Serial item No 44 above but area n.exc 1.5 sqm each complete all as specified and directed. |
| 46 | Taking down shutters of any description area n exc. 1 sqm each and removing from site complete all as specified and directed. |
| 47 | Taking down shutters of any description area exc. 1 sqm and n. exc. 2 sqm each and removing from site complete all as specified and directed. |
| 48 | S&F second class hard wood, plain, solid straight chowkats and frames, wrought, framed rebated on the solid, rounded or chamfered, put together with glue pinned at joints complete all as specified and directed. |
| 49 | S&F in repairs 30 mm thick flush shutters, solid core construction, with block board core and plywood face panels, commercial type both sides (ISI marked) all with 6 mm thick teak wood edging all round complete all as specified and directed. |
| 50 | S&F in repairs 35 mm thick factory made second class hard wood glazed and skeleton shutters, open rebated and prepared to receive glass, gauze, etc. (without sash bars), edges of framing plain, chamfered or rounded, fitted with cut and mitred beads for securing glass, etc. sizes of members of shutters as specified in SSR Part-I, Section 8, clause 8.24(a), supplied and fitted to chowkats complete all as specified and directed. |
| 51 | S&F in repairs factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails. M.S. frame shall be covered with heat moulded plain colour PVC sheet strip of 20 mm width struck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail. Panelling of plain colour PVC sheet to be fitted in the M.S. frame welded/sealed to the stiles & rails with suitable PVC sheet beading and joined together with solvent cement, and fixing in the frame at site complete all as specified and directed. |
| 52 | S&F in repairs Solid PVC Door Frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with M.S Square tube complete all as specified and directed. |
| 53 | S&F MS butt hinges, of size 100 mm complete all as specified and directed. |
| 54 | S&F 150 mm long aluminium, anodized, barrel tower bolts of extruded section and fixed complete all as specified and directed. |
| 55 | S&F 100 mm long aluminium, anodized, barrel tower bolts of extruded section and fixed complete all as specified and directed. |
| 56 | S&F 300 mm long aluminium alloy, anodized, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy complete all as specified and directed. |
| 57 | S&F Extruded aluminium alloy handles,150mm long fabricated type., anodised complete all as specified and directed. |
| 58 | S&F Extruded aluminium alloy handles, 100 mm long fabricated type anodised complete all as specified and directed. |
| 59 | S&F figured glass, pin head type & glazing with oil putty in square n exc 0.5 sqm in each pane 3 mm thick complete all as specified and directed. |
| 60 | S&F Galvanised mild steel wire cloth, 0.56mm nominal dia of wire and average width of aperture 1.18 mm and fixed with tinned tacks, or galvanised wire staples complete all as specified and directed. |
| 61 | S&F mild steel of grade Fe-290 in bands, straps, supports or stays for rain water, ventilating pipes including bolts, if required, clamps, hold fasts and similar small articles complete all as specified and directed. |
| 62 | Hacking out old broken glass (any thickness, size, quality or description) from metal frame including punching or drilling out old glazing pins/spring clips and providing and fixing new ones complete all as specified and directed. |
| 63 | S&F 3 mm thick sheet glass ordinary quality & glazing with oil putty in squares n. exc. 0.5 SM in each pane complete all as specified and directed. |
| 64 | S&F figured glass 4 mm thick, pin head type & glazing with oil putty in squares n. exc. 0.5 SM in each pane complete all as specified and directed. |
| 65 | S&F in repairs galvanised mild steel wire cloth, 0.56mm nominal dia of wire and average width of aperture 1.18 mm and fixed with tinned tacks, or galvanised wire staples complete all as specified and directed. |
| 66 | S&F in repairs 0.56 mm thick Plain, Aluminium sheeting, Alloy 31000 H4 drip and straight flashing complete all as specified and directed. |
| 67 | S&F in repairs floor door stopper of aluminium body and tongue anodised with hard drawn steel spring fixed in floor over all length of cover plate 150mm complete all as specified and directed. |
| 68 | S&F in repairs 300 mm long Aluminium allow anodised sliding door bolt with hasp staple (bolt type ) and fixing clips of sheet cast or extruded section and fixing bolts and sliding bolts of extruded section or cast alu allow complete all as specified and directed. |
| 69 | S&F in repairs 150 mm long Aluminium anodised barrel tower bolt of extruded section complete all as specified and directed. |
| 70 | M&L for two coats of synthetic enamel paint to wooden surfaces (frame & shutter) over & including a coat of primer and preparation of surface of any description, not otherwise descrbed, over 10cm width or girth complete all as specified and directed. |
| 71 | S&F Steel windows with side hung shutters including projecting type hinges with steel handle, and steel peg stay, complete with glazing bars, dovetailed or welded complete all as specified and directed. |
| 72 | All as per BOQ Serial item No 71 above but without glazing bars complete all as specified and directed. |
| 73 | S&F Steel ventilator with top hung shutter including hinges, steel peg stay complete all as specified and directed. |
| 74 | M&L for applying two coats of synthetic enamel paint to steel surfaces (frame & shutter) over & including a coat of red oxide primer and preparation of steel surface of any description, not otherwise described, over 10cm width or girth complete all as specified and directed. |
| 75 | M&L for repairing and welding to steel windows includign making functional (easy to opening and closing) and replacing the missing damaged parts complete all as specified and directed.Note : Spare parts required shall be measured and paid separately. |
| 76 | M&L for repairing and welding to steel box/projection type hinges to steel door/windows shutter, includign making functional (easy to opening and closing) and cutting existing projected hinges etc missing/damaged parts complete all as specified and directed. |
| 77 | M&L for repairing and welding to steel Door includign making functional (easy to opening and closing) and replacing the missing damaged parts complete all as specified and directed.Note : Spare parts required for measured and paid separately under respective items and supply only. |
| 78 | Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and directed. |
| 79 | M&L for Framed work such as grills to window/ventilation, gratings, etc., with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe 290 Gde E-165 complete all as specified and directed. |
| 80 | S&F in repairs second class hard wood Plain fillets, square, rectangular or triangular in section, wrought, secured with nails or brads, sectional area exc 13.00 Sqcm. n exc 25.00 Sqcm complete all as specified and directed. |
| 81 | S&F in repairs second class hard wood Plain fillets, square, rectangular or triangular in section, wrought, secured with nails or brads, sectional area exc 3.00 Sqcm. n exc 6.00 Sqcm complete all as specified and directed. |
| 82 | S&F in repairs 18/19 mm thick Prelaminated particle board,exterior grade, fixed with screws to timber frame work but prelaminated both sides with decorative choice laminations complete all as specified and directed. |
| 83 | S&F 18 / 19 mm thick Veneered particle board, fix in cupboard shelves, interior grade, solid core, medium density general purposes type with commercial face veneers type ‘BB’ complete all as specified and directed. |
| 84 | S&F Hasp and staple 100mm, allumuniun anodised, wire type, stove enamelled black, including bolt to hinge plate and fixed with screws complete all as specified and directed. |
| 85 | S&F Continuous (piano) hinges, mild steel, bright finish or electrogalvanised width of flaps 40mm ( when open) in repair complete all as specified and directed. |
| 86 | S&F in repairs 40 mm knobs of brass, polished fixed with nut screw &washer bright finished complete all as specified and directed. |
| 87 | Ball catcher with 8 mm dia steel ball and brass body and skirting plate including leting in and fixed complete all as specified and directed. |
| 88 | S&F in repairs CP Curtain rod 20mm dia including bracket and end knobs etc complete all as specified and directed. |
| 89 | Demolition of PCC in Ground Floor and paving n exc 15 cm (below or above ground level) including removal of all debris outside MoD land complete all as specified and as directed |
| 90 | M&L for PCC type D-2 1:4:8 using 40mm graded stone aggregates, 75 mm thick as in sub base for floors, etc complete all as specified and directed. |
| 91 | M&L for 25 mm thick PCC 1:2:4 type B-0 using 12.5 mm graded stone aggregates as in sub base of floor, etc complete all as specified and directed. |
| 92 | Dismantling of floors health or walls tiling and stone floors including cement mortar bedded (but not backing) & removing serviceable tiles to store and including removal of all debris outside MoD land complete all as specified and directed. |
| 93 | M&L for Coloured Non Skid ceramic tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.06 Sqm but not exceeding 0.11 Sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match with and including screed bed 15 mm thick in CM (1:6) complete all as specified and directed. |
| 94 | M&L for coloured Glazed ceramic tiles in vertical surfaces 350 x 250x7mm or 450x300x7 mm thickness as per manufacture on vertical surfaces and jointed in neat cement slurry and pointed in white or coloured cement to match over & including 10 mm in CM 1:3 complete all as specified and directed. |
| 95 | M&L for non skid coloured ceramic tiles 7 to 8 mm thick (Square/rectangular) area of each tile exc 0.11 sqm but n.exc 0.18 sqm in floor etc set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles over and including 15mm thick screed bed in CM (1:6) complete all as specified and as directed. |
| 96 | All as per BOQ Serial item No 95 above above but fixed on vertical surface as on skirting over & including 10mm thick cement plaster in cement mortar (1:4) complete all as specified and directed. |
| 97 | M&L for double charged vitrified coloured tiles (Premium Quality) of size (600x600mm) x 8-9mm thick in floor, etc set and jointed in neat cement slurry and pointed in white cement mixed with pigment to match the shade of tiles over and including 15 mm thick screed bed in CM (1 : 6 ) for laying of floor finishes complete all as specified and as directed. |
| 98 | All as per BOQ Serial item No 97 above above but fixed on vertical surface as on skirting over & including 10mm thick cement plaster in cement mortar (1:3) complete all as specified and directed. |
| 99 | M&L for plain cement concrete 1:3:6 Type C1 (using 20mm graded stone aggregate), in copings, kneelers, apex stones,bed plates, kerbs, water troughs and the like including weathering, slightly rounded or chamfered angles and throating, complete all as specified and directed. |
| 100 | M&L for Granite (of any type) 18 to 20 mm thick work (table rubbed and polished) in steps, jambs, pillars, window cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade complete all as specified and directed. |
| 101 | M&L for green marble work 18 to 20mm thick ( table rubbed and polished) as in steps, jambs, pillers, window cills, cooking platform and like in cement mortor (1:4) including pointing with white cement (1:2) using marble dust with admixture pigment to match with marble shade complete all as specified and directed. |
| 102 | M&L for white marble work 18 to 20mm thick (table rubbed and polished ) in steps, jambs, pillers, window cills,cooking platform and like in cement mortor (1:4) including pointing with white cement (1:2) using marble dust with admixture pigment to match with marble shade complete all as specified and directed. |
| 103 | Drilling holes for bolts, pipes, etc. n. exc 25mm dia in granite or trape stone for gas connection pipe complete all as specified and directed. |
| 104 | Rounding to edges of stone slabs (one edge) such as in steps, cooking platform and other similar situations complete all as specified and directed. |
| 105 | Taking down Eaves gutter, rain water pipes (any size and pattern) incl all fitting, bends, shoes, swan neck etc incl cleaning, refixing and removing to store etc complete all as per specified and directed. |
| 106 | S&F in repairs PVC (SWR) floor trap, plain with grating including jointing with solvent cement 75 mm dia out let complete all as specified and directed. |
| 107 | S&F in repairs PVC (SWR) pipe 110 mm dia, single socketed; fixed laid in floors or tranches complete all as specified and directed. |
| 108 | S&F in repairs PVC (SWR) pipe 75 mm dia, single socket in floor or tranches complete all as specified and directed. |
| 109 | S&F in repairs PVC (SWR) pipe 110 mm dia, single socketed fixed to walls complete all as specified and directed. |
| 110 | S&F in repairs PVC (SWR) pipe 75 mm dia, single socket fixed to walls complete all as specified and directed. |
| 111 | S&F in repairs PVC (SWR) junction single tee equal or unequal 110 mm dia with access door complete all as specified and directed. |
| 112 | S&F in repairs PVC (SWR) junction single tee equal or unequal 75 mm dia with access door complete all as specified and directed. |
| 113 | S&F in repairs PVC (SWR) bends of 110 mm dia, any radius complete all as specified and directed. |
| 114 | S&F in repairs PVC (SWR) bends of 75mm dia, any radius complete all as specified and directed. |
| 115 | S&F in repairs PVC (SWR) 110 mm branch piece, single (single Y), equal or unequal complete all as specified and directed. |
| 116 | S&F 100 mm bore Cast iron soil, waste and vent pipes in any length with or without ears, with cement joints, fixed to walls complete all as specified and directed. |
| 117 | S&F 75 mm bore Cast iron soil, waste and vent pipes in any length with or without ears, with cement joints, fixed to walls complete all as specified and directed. |
| 118 | S&F 100 mm bore CI Bends (any radius), diminishing pieces or tapers (larger bore measured) complete all as specified and directed. |
| 119 | S&F 75 mm bore CI Bends (any radius), diminishing pieces or tapers (larger bore measured) complete all as specified and directed. |
| 120 | S&F 100 mm bore CI Branch pieces, double (equal or unequal), ordinary or inverted (spigot or socket type) or with parallel branches complete all as specified and directed. |
| 121 | S&F 100 mm bore CI Cast iron cowls complete all as specified and directed. |
| 122 | S&F in repairs Health faucet with 1.5 mtr tube and hook complete all as specified and as directed. |
| 123 | S&F in repairs 15 mm dia Bib tap standard of PTMT any colour high pressure screwed for iron pipe and fixed (Minimum weight 15mm-90gms) complete all as specified and directed. |
| 124 | S&F in repairs 15 mm dia Pillar taps of PTMT any colour high pressure screwed for iron pipe and fixed (Minimum weight 15mm-110gms) complete all as specified and directed. |
| 125 | S&F in repairs 15 mm dia Stop valve of PTMT any colour high pressure screwed for iron pipe and fixed (Minimum weight 15mm-90gms) complete all as specified and directed. |
| 126 | S&F in repairs 15mm bore piller taps of cast copper with capstan head CP screwed down high pressure with or without lettered hot and cold with long screwed shank and fly nut for iron pipe complete all as specified and directed. |
| 127 | S&F in repairs Self-closing taps, cast copper alloy, chro-mium plated, screwed for iron pipe 15 mm dia and fixed complete all as specified and directed. |
| 128 | S&F in repairs Bib taps, fancy type and chromoum plated, cast copper alloy with crutch or butterfly handle, sc-rewed down, screwed for iron pipe or for brass ferrule 15 mm bore complete all as specified and directed. |
| 129 | S&F in repairs Stop valves 15mm dia , cast copper alloy, screwed down, high pre-ssure, with crutch or but-terfly handle, screwed both ends for iron pipe or for unions and fixed complete all as specified and directed. |
| 130 | S&F in repairs wall mixture brass CP tap for mixing hot and cold water including three joints to 15 mm bore pipes or union and pluging and screwing to wall complete all as specified and directed. |
| 131 | S&F in repairs brass Chromium plated shower roses 125mm size with or without swivel joints, any size, including fixing to steel pipe or union complete all as specified and directed. |
| 132 | S&F in repairs 32mm dia PVC waste pipe for kitchen sink, WHB, Urinal etc complete all as specified and directed. |
| 133 | S&F in repairs PVC connections 15 mm size with PTMT nuts of length 450mm complete all as specified and directed. |
| 134 | S&F in repairs towel rail 600 mm long of Brass C.P 'D' type fixed with and including chromium plated brass screws complete all as specified and directed. |
| 135 | S&F in repairs 32 / 40 mm bore Waste fittings, brass, chromium plated for glazed ware sinks, basins, etc. with long screwed shanks and fly-nuts, flange end bedded in red lead cement and other end fixed complete all as specified and directed. |
| 136 | S&F in repairs High density polyethylene pipes (HDPE) 40 mm dia (bore) of pressure rating 6 kgf/cm2 laid in trenches complete all as specified and directed. |
| 137 | S&F in repairs Viterious china White Handwash Basin with & including 15 mm pillar cock cast copper alloy CP, 15mm cast copper stop valve, 32 mm brase CP waste fitting & 15 mm PVC connection pipe 450 mm long complete all as specified and directed. |
| 138 | S&F in repairs 10 liters capacity PVC low level flushing cistern with ISI marked body complete all as specified and directed. |
| 139 | S&F in repairs, stainless steel kitchen plate rack of minimum size 3 'x 3' etc complete all as specified and directed. |
| 140 | S&F in repairs, vitreous china wash down water closet pan, (pedestal pattern), white, with and including plastic water closet seat, white, closed pattern with flat bottom, and cover and mild steel chromium plated or aluminised hinging device etc including removal of all debris outside MoD land complete all as specified and directed. |
| 141 | S&F in repairs vitreous china squatting pan, ‘Orissa’ pattern, size 580 mm x 440 mm, white with integral foot rests, embedded and set in PCC 1:5:10 type E-2 and making good to floor including removal of all debris outside MoD land complete all as specified and directed. |
| 142 | S&F in repairs sinks with drainage board made of stainless steel 1mm thick kitchen or laboratory with plugs, washers and waste; including bedding in cement mortar to dwarf wall or including fixing cantilever brackets and connecting union to pipe overall size 915mm x 460mm bowl size 410mm x 330mm x 160mm complete all as specified and directed. |
| 143 | S&F in repairs sinks made of stainless steel 1mm thick kitchen or laboratory with plugs, washers and wastes; including bedding in cement mortar on to dwarf wall or including fixing cantilever brackets and connecting union to pipe, overall size 485mm x 420mm bowl size 410mm x 330mm x 160mm complete all as specified and directed. |
| 144 | Taking up or down steel tubing & connections incl cleaning for relaying of pipe 15 mm bore or removing complete all as specified and directed. |
| 145 | Taking up or down steel tubing & connections incl cleaning for relaying of pipe 20 mm bore pipes complete all as specified and directed. |
| 146 | Taking up or down steel tubing & connections incl cleaning for relaying of pipe 25 mm bore pipes complete all as specified and directed. |
| 147 | S&F steel water tubing med grade GI with all fittings & fixed complete to walls & ceilings or laid on floors of bore of pipe 15 mm complete all as specified and directed. |
| 148 | Refixing of old steel water tubing & connecting in new or old position (wall, ceiling & floor, etc.) of bore of pipe 15 mm complete all as specified and directed. |
| 149 | S&F steel water tubing med grade GI with all fittings & fixed complete to walls & ceilings or laid on floors of bore of pipe 20 mm complete all as specified and directed. |
| 150 | Refixing of old steel water tubing & connecting in new or old position (wall, ceiling & floor, etc.) of bore of pipe 20 mm complete all as specified and directed. |
| 151 | S&F steel water tubing med grade GI with all fittings & fixed complete to walls & ceilings or laid on floors of bore of pipe 25 mm complete all as specified and directed. |
| 152 | Refixing of old steel water tubing & connecting in new or old position (wall, ceiling & floor, etc.) of bore of pipe 25 mm complete all as specified and directed. |
| 153 | S&F in repairs Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed 15 mm bore pipe complete all as specified and directed. |
| 154 | S&F in repairs Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed 20 mm bore pipe complete all as specified and directed. |
| 155 | S&F in repairs 500 litres capacity rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top), hoisted and fixed in position all as specified in SSR Part-I, connecting up pipes including 15 mm bore ball brass valves, high pressure, with polythene float and fly- nut complete, screwed for iron pipe or brass ferrule and fixed complete all as specified and directed. |
| 156 | S&F in repairs 1000 litres capacity rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top), hoisted and fixed in position all as specified in SSR Part-I, connecting up pipes including 15 mm bore ball brass valves, high pressure, with polythene float and fly- nut complete, screwed for iron pipe or brass ferrule and fixed complete all as specified and directed. |
| 157 | S&F in repairs PVC (SWR) floor trap, plain with grating including jointing with solvent cement 75 mm dia out let complete all as specified and directed. |
| 158 | S&F in repairs 600mmx450mm bevelled edge mirror of selected quality glass, mounted on 6mm thick AC building board or commercial plywood and fixed to wooden plugs with chromium plated brass screws and cup washers complete all as specified and directed. |
| 159 | S&F in repairs PVC seat cover for EWC white/black colour complete with MS Hinged cromlum plated complete all as specified and directed. |
| 160 | S&F in repairs aluminium anodised Hasp and staple, safety type, with mild steel hinge pin including bolt to hinge plate and fixed with screws 100mm complete all as specified and directed. |
| 161 | Demolition of Brickwork or stone/boulder masonry, built in cement mortar including removal of all debris outside MoD land complete all as specified and directed. |
| 162 | M&L for Brickwork with subclass ‘B’ bricks, straight or curved on plan exc 6m mean radius built in CM 1:4 complete all as specified and directed. |
| 163 | M&L for Brickwork with subclass ‘B’ bricks, straight or curved on planbuilt in CM 1:4 complete all as specified and directed. |
| 164 | S&F in repairs Aluminium (extruded section body), Door closer hydraulically regulated, designation No. 2, universal type, suitable for door shutters of 701 to 850 mm in width and of weight between 36 to 60kg and fixed complete all as specified and directed. |
| 165 | S&F in repairs Powder coated aluminium sliding windows for three track with rubber gasket, stopper powder coated aluminium standard beads/glazing clips ,locking arrangement etc and aluminium frame of size 80mmX25mmX1.55mm and shutter of section 20mm X20mm X1.55mm incl ( two shutter of 4.8mm thick glass and one shutter of wiremesh 0.36 mm dia of wire and average width of aperture 1.40 mm) including with necessary all fittings as per manufacturer's instructions and complete all as specified and as directed. |
| 166 | Dismantiling of Asbestos cement (Corrugated, semicorrugated, etc) sheet in roof coverings including removal of all debris outside MoD land complete all as specified and as directed. |
| 167 | Dismantling of timber scantling 40 sq.cm and over in section, in any postion framed work complete all as specified and as directed. |
| 168 | Dismantling of timber scantlings as in fillets, rails, posts, rafters, purlins, etc under 40 sq.cm in section, in any postion framed work complete all as specified and as directed. |
| 169 | Dismantling of wall and ceiling boards (fibre, pulp, insulation etc) of insulation boards/slabs/blankets, any thickness, including cover fillets complete all as specified and directed. |
| 170 | M&L for 4mm thick non asbestos reinforcement gypsum (GRG) ceilling tiles of size 595 x 595 mm of approved design fixed with & including powder coated (powder coating on web bottom only) GI grid consisting of main Tee section of size (15mm x 30mm), cross Tee section of size (15mm x 23mm), and powder coating GI wall angle of size (20mm x 20mm) suitable for mounting ceiling tiles of 595 x595 mm with 4 mm dia GI wire suspended including fabrication complete as per manufacturers instructions fixed with steel rawl plug with nut and bolts arrengement with grid size 60 x 120 cm complete all as specified and as directed.Make : Diamond Brand TM/ Dexune or equivalent as approved by GE. |
| 171 | S&F pre-painted galvatume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick of colour as approved having tensile strength of 550 Mpa as in roof covering /cladding to wall, fixed with self tapping srews complete all as specified and directed. |
| 172 | S&F pre-painted galvatume aluminium zinc coating GI based Plain steel sheet 0.50mm thick of colour as approved having tensile strength of 550 Mpa as in roof covering /cladding to wall for rain water pipe ,fixed with self tapping srews complete all as specified and directed. |
| 173 | S&F MS rolled section as in roof purlins, rafters and truss etc of MS pipe fixed with iron cleats along with nuts & bolts of required size or section or welded conforming to Fe-290 Gde E-165 including dismantling old steel/iron works complete all as specified and directed. Please Enable Macros to View BoQ information |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
| 5 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail