| 1 | Demolition of brick work or stone/ boulder masonry, built in cement mortar including all quoins, pillars etc. complete all as specified and as directed. |
| 2 | M&L for Brick work with fly ash bricks, straight or curved on plan exceeding 6 M mean radius built in cement mortar 1:6 Complete all as specified and as directed. |
| 3 | Taking down cement plaster on brick or stone wall etc. including racking out joints hacking for key scrubbing down with water etc complete all as specified and as directed. |
| 4 | M&L for Rendering 15 mm thick cement plaster in CM 1:4 on fair faces of brick/concrete surfaces finished fair and even, mixed wth water proofing compound admixture (if directed) as per manufacturer's instruction, complete all as specified and directed.Note :- WPC will measuered and paid separatly under relevant item of schedule. |
| 5 | Supply only integral Liquid water proofing compound complete all as specified and as directed. |
| 6 | S&F Factory made 30 mm thick Flush shutters, solid core construction, with block board core and plywood face panels, commercial type on both sides complete all as specified and as directed. |
| 7 | M & L for preparation of old surface of wood and wood based surfaces by knotting, stopping etc of any description exc 10 cm width or girth and applying two coat of synthetic enamel paint complete all as specified and directed. |
| 8 | M & L for preparation of new surface of wood and wood based surfaces by knotting, stopping etc of any description exc 10 cm width or girth and applying two coat of synthetic enamel paint over a coat of pink primer complete all as specified and directed. |
| 9 | M & L for preparation of old painted steel and iron surfaces of any description exc 10 cm width or girth and applying Two coat of synthetic enamel paint by using spray machine complete all as specified and directed. |
| 10 | M & L for preparation of old painted steel and iron surfaces of any description not exc 10 cm width or girth and applying Two coat of synthetic enamel paint by using spray machine complete all as specified and directed. |
| 11 | Demolition of PCC in ground floors & pavings n exc 15 cm thickness (below or above ground level) (unreinforced) complete all as specified and directed. |
| 12 | M&L 100 mm thick PCC type B-1, (1:2:4) using 20mm graded stone aggregate as in receiving floor finished rough and even complete all as specified and directed. |
| 13 | M & L for cement concrete 100mm thick 1:4:8, Type D-2 (Using 40 mm graded stone aggregates) as in sub base for flooring etc complete all as specified and directed. |
| 14 | Dismantling of floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and directed. |
| 15 | M & L for screed or bedding layer 15mm thick in cement mortar 1:6 laying floor finishes complete all as specified and as directed. |
| 16 | M&L Non skid ceramic coloured tiles 7 to 8mm thick (square/rectangular) area of each tile exceeding 0.06sqm but not exceeding 0.11 sqm in floors laid over and including 15mm thick 1:6 cement mortar screed bed etc. set and jointed in neat cement slurry and pointed in white of coloured cement to match complete all as specified and directed. |
| 17 | M&L Virified Ceramic tiles 8 mm thick LIGHT SHADE (square/ rectangular) polished, area of each tiles exceeding 0.36 sqm but not exceeding 0.42 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and directed. |
| 18 | Taking down chowkat or frames exc 1.5 sqm but n exc 4.0 sqm each with shutter (without taking off shutters from the frame) complete all as specified and as directed. |
| 19 | Taking down Chowkats or frames not exc. 1.5 sq. m each with shutters (without taking off shutters from the frames) complete all as specified and as directed. |
| 20 | S&F Powder coated aluminium (minimum thickness of powder coating 50 micron) work for doors, windows, ventilators frame and partitions (Fixed portions) with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/ paneling, C.P. brass/ stainless steel screws, all complete as per the directions of Engineer-in-Charge |
| 21 | S&F Powder coated aluminium (minimum thickness of powder coating 50 micron) for shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber/neoprene gasket required (Fittings shall be paid for separately) with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/ paneling, C.P. brass/ stainless steel screws all complete as per architectural drawings and the directions of Engineer-in-chargeher for openable/sliding shuttters) including all necessary fittings as directed |
| 22 | S&F Solid PVC door frame of size 50mm x 95mm made out of 5mm wood grain printed PVC sheet reinforced with M.S. tube, in opening as per specification & drawing complete all as specified and as directed. |
| 23 | S&F Factory made solid moulded PVC door shutter 28 to 30mm thick (style) with 2,4 or 6 raised panel design with 2 mm thick 3D wood grain moulded PVC sheet polyurathane painted on the front face & 2 mm thick plain colour PVC sheet on back face with particle face supply & fixing on frame, as per specification & drawing complete all as specified and as directed. |
| 24 | S&F pressed steel door frames of size 165X60mm, of doors with one or more rebates including necessary fixing lugs, hinges(03 Nos of 100 mm size and 01 No of 50 mm size medium weight coled rolled mild steel butt hinges per leaf ) lock strike plate, etc incl one shop coat of priming complete all as specified and directed(Th 1.60 mm) |
| 25 | S&F Sheet glass 4.8 mm thick, ordinary quality & glazing with oil putty in square but n.exc 0.5 sq.m in each pane complete all as specified and as directed. |
| 26 | S&F in repair Aluminium (extruded section) body Door closer hydraulically regulated, designation No 3, universal type, suitable for door shutters of 851 to 1000 mm in width & of weight between 61 to 80kg complete all as specified and as directed. Make: Godrej |
| 27 | S&F Stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples, complete all as specified and as directed. |
| 28 | Dismantling Wall & ceiling boards (fibre, pulp, insulation, etc.) or insulation boards/slabs/blankets, any thickness, including cover fillets complete all as specified and as directed. |
| 29 | S&F anodised aluminium snap grid frame work for false ceiling, size of grid 605 x 605mm, including hangers 6 mm dia GI (upto 1200 mm length) adjusting level fixed to roof slabs by means ceilings cleats made out od GI flat 40x3 mm size 60 mm long and expansion hold fastners 12.5 mm dia, and 6 mm thick non asbestos fibre cement building boards fixed or laid/inserted to timber/GI/Aluminium frame work, complete all as specifed and as directed. |
| 30 | S&F 18/19 mm thick, lead free PVC board Superior quality of density not less than 0.55 g/cm3 as in moduler shutters/cabimet drawer cupboard cabinet shutter including all frame work as specified and directed by Engr-in-Charge |
| 31 | S&F 40mm thick PUF roof panel fabricated with pre-painted hot-dip aluminium-zinc alloy metallic coated plain steel sheet coating class AZ150, 0.50 mm thick, of an approved colour and having yield strength of 550 MPa, infill with CFC free PUF having density not less than 40 kg/m3 (Polyurethane Foam) sandwich panels with suitably designed fixed to roof with nut bolt or screws and jointed with silicon selant metal adhesive all as specified and directed. |
| 32 | M&L for under/ over deck leaking arrests to PUF/steel sheet roofs by using 5mm thick bituminous sheet (exc 29 sqcm and n exc 40 sqcm of each piece) including filling silicon sealand adhesive materials in holes, MS screws, washers etc where required at leakages of roof sheets all as specified and as directed. |
| 33 | S&F Mild steel Butt hinges 100mm size, medium weight, complete all as specified and as directed. |
| 34 | S&F Aluminium alloy, anodised, sliding door bolt 300mm long with hasp, staple (bolt type) & fixing clips of sheet, cast or extruded sections & fixing bolts & sliding bolts of extruded sections or cast aluminium alloy complete all as specified and as directed. |
| 35 | S&F extruded Aluminium alloy handles 150mm size, cast type, anodised complete all as specified and as directed. |
| 36 | S&F Aluminium, anodised, barrel tower bolts 200mm long of extruded section complete all as specified and as directed. |
| 37 | S&F 150 mm long Floor door stopper of aluminium alloy body and tongue, anodised, with hard drawn steel spring, fixed in floor complete all as specified and as directed. |
| 38 | S&F in repair for 4mm thick Prelaminated particle board, interior grade, prelaminated one side with decorative choice lamination & other side balancing white lamination, fixed to aluminium/wooden frame work complete all as specified and as directed. |
| 39 | S&F in repairs kitchen sinks with drainage board made of stainless steel 1mm thick kitchen or laboratory with plugs, washers and wastes, coupling including bedding in cement mortar on to dwarf wall or including fixing cantilever brackets and connecting union to pipe, overall size 915mmx460mm bowl size 410 mmx330mmx 160mm etc complete all as specified and as directed. |
| 40 | S&F in repair chromiuim plated Swivel shower roses with shower arm, 125 mm size including fxing to steel pipe or union etc complete all as specified and as directed. |
| 41 | S&F in repairs tubular towel rail 20 mm dia ‘D’ type 60 cm long between flanges of brass chromium plated including brackets. complete all as specified and as directed. |
| 42 | S&F in repair glass self assembly consisting of 5.5 mm thick glass sheet glass self 12 Cm wide with CP bracket gaurd and railing 60 Cm long complete all as specified and as directed. |
| 43 | S&F in repair chromium plated 15 mm central hole basin mixer single lever without popup waste system with 450 mm long braided hoses complete all as specified and as directed. |
| 44 | S&F in repair fancy type 15mm dia stop valves, cast copper alloy, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed for iron pipe fixed in repair complete all as specified and as directed. |
| 45 | S&F in repairs Gun metal, globe or gate valve with iron wheel head, 20 mm bore, screwed both ends for iron pipe complete all as specified and as directed. |
| 46 | S&F in repair angle cock 15 mm bore fancy type chromium plated, with capstan head, high pressure, screwed down, screwed for iron pipe or for brass ferrule fixed to iron pipe complete all as specified and as directed. |
| 47 | S&F in repairs health faucet ((ABS Body) mild steel chromium plated suitable for 15mm dia pipe with 1.25 meter long flexible tube and ABS wall 1.25 m long flexible tube and ABS wall hook including making connection and fixed in position complete all as specified and as directed. |
| 48 | S&F in repairs toilet paper holder with flat recessed type stainless steel complete all as specified and directed |
| 49 | M & L for TMT bars 8mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for floor, hooking ends and binding with the including mild steel wire (annealed) not less than 0.9mm dia or securing with clips all as specified and directed. |
| 50 | Dismanting of corrugated or semi corrugated Asbestos sheeting, in any roof coverings, complete all as specified and as directed by Engineer-in-charge complete all as specified and as directed. |
| 51 | M & L for pre-painted hot-dip aluminium-zinc alloy metallic coated of any profile steel sheet corresponding to IS 15965:2012 of durability class 3, atmospheric classification category 3, coating class AZ150, 0.50 mm thick, of an approved colour and having yield strength of 550 MPa as in roof covering fixed with self tapping screws as specified up to anyheight including all necessary scaffolding and safety measures complete all as specified and directed. |
| 52 | M & L for pre-painted hot-dip aluminium-zinc alloy metallic coated plain steel sheet as per IS 15965:2012 of durability class 3, atmospheric classification category 3, coating class AZ150, 0.50 mm thick, of an approved colour and having yield strength of 550 MPa as in ridge/ valley/ gutter fixed with self tapping screws as specified any height Mtr height including all necessary scaffolding and safety measures complete all as specified and directed. |
| 53 | Dismanting of wrought iron or mild steel work af any description not otherwise provided for complete all as specified and as directed by Engineer-in-charge |
| 54 | S&F Roof trusses (framed), trussed, purlins, crane gantries, rails andfastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc Fe-410- W(Gde- E-250) quality-B. complete all as specified and directed. |
| 55 | S&F for Rolled Mild steel Joist, channel, angle, or tee sections (Fe-410W Gde-E-250 Quality B) fixed independently, without connecting plates, etc. (cut to ordinary lengths i.e. within 20mm of the length indicated), all as specified and as directed. |
| 56 | S&F for Rolled Mild steel Plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, without any attachment (Fe-410W Gde-E-250 Quality B), all as specified and as directed. |
| 57 | Excavating in post holes ( or similar holes) each n.exc 0.5 cum getting out , and removing surplus soil to a distance n.exc 50m and making good surface, in soft/loose soil complete all as specified and as directed. |
| 58 | M&L Cement concrete 1:3:6 (40mm graded stone) in foundations, filling and mass concrete in post hole all as specified and as directed. |
| 59 | M&L Hand rails, half round or other steel section or core for wooden hand-rail straight portion, drilled and countersunk for balusters running bars, for doors, balusters, nosing to steps including embeding in concrete and screwing etc. wind ties for roof including securing bolts; complete all as specified and directed. |
| 60 | S&F in repair soft closing 'O' Degree high grade mild steel, bright finish or electro galvanised for cup board shutter complete all as specified. |
| 61 | S&F in repair magnetic catcher for kitchen cabinet shutter as approved by Engr-In-Charge. |
| 62 | S&F in repair C.P bib taps long body cast copper alloy with capston headed handles, screwed down screwed for iron pipe 15 mm bore or for brass ferrule complete fixed in repair complete all as specified and as directed. |
| 63 | S&F in repair Pillar taps (Swan Neck)fancy type 15mm bore cast copper alloy, with capstan heads, chromium plated, screwed down high pressure, with or without lettered 'Hot' or 'Cold' with long screwed shanks and fly-nuts, screwed for iron pipe and fixed complete all as specified and as directed. |
| 64 | S&F in repair dropery rod powder coated 25mm internal dia with fancy type brackets and side knobs as per sample complete all as specified and as directed by Engineer-in-Charge . |
| 65 | S&F in repair stainless steel kitchen plate rack(24''x24''x10'') including necessary fixing/fitting & making good the existing surface complete all as specified and directed. |
| 66 | S&F 20 mm outer dia medium grade CPVC, SDR 11 & plain CPVC SDR 11 with all fittings (brass inside the fittings) and fixed complete to walls and ceiling or laid in floors complete all as specified and directed. |
| 67 | Taking up or down 20mm dia GI steel tubing and connections, including cleaning for refixing or removal to store complete all as specified and as directed. |
| 68 | Supply & Fixing in repairs Vitreous China Ware Wash hand basin white flat back size 550mmx400mm without pedestal, cutting for and pinning ends of brackets or erecting stand including necessary PVC outlet pipe, CP coupling 32mm dia complete all as specified complete all as specified |
| 69 | S&F PVC connections 15 mm size with PTMT nuts of length 600mm complete all as specified and as directed. |
| 70 | S&F in repairs waste coupling of 40mm dia brass chromium plated for glaze ware sinks, basins, etc with long screwed shanks and fly nuts flange and bedded in red lead cement and other end fixed complete all as specfied and as directed |
| 71 | S&F in repair grating doom 125mm dia with waste hole of PTMT minimum weight 40 Gms complete all as specified and as directed. |
| 72 | Supply and fixed in repairs floor mounted (single piece WC) bowl with cistern for coupled WC with and including UF soft close slim seat cover, hinges, dual flush cistern fitting, fixing accessories and accessories set complete of size 380x655x765 mm with S Trap- 250 mm, connector to branch soil pipe and anti syphonage pipes etc. including sealing the joints and making leak proof using sealant complete all as specified and as directed by Engineer-in-Charge. |
| 73 | M&L in repair Vitreous China urinals, half stall type (back or corner wall type), complete including providing and fixing plugs, bedding urinal against wall in cement mortar 1:2, securing urinal to plugs with and including 60mm long brass screws, pointing around urinal back in cement; fixing automatic flushing cistern with brackets, flush pipe, grating and Union for discharge pipe. (Exclusive of fixing supply pipe to flushing cistern, trap and waste pipe) includind Urinal spreader of PTMT any colour for fixing with 15 mm dia pipe. (Minimum weight 60gms) & Waste coupling of PTMT (half or full threaded).(Minimum weight 32mm 45gms/40mm-60 gms) |
| 74 | Supply & fix mirror 600mmx 400mm bevelled edge mirror of selected quality glass, mounted on 6 mm thick AC building board or commercial plywood and fixed to wooden plugs with chromium plated brass screws and cup washers complete all as specified and directed. |
| 75 | S&F in repairs Door seal (Snake guard) with Aluminium frame powder coated complete all specified |
| 76 | Running Welding in repair of door shutter/ window/iron gate in position (exc 6mm but n exc 9mm) complete all as specified and as directed. |
| 77 | Taking down PVC rain water pipe any size or pattern including all fittings all as specified and directed. |
| 78 | S&F 110mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to wall/laid in floor complete all as specified and as directed. |
| 79 | S&F in repair 110mm bore PVC (SWR) bends any radius complete all as specified and as directed. |
| 80 | S&F in repair 110mm dia PVC (SWR) junction, single (single T) equal or unequal with door access all as specified and as directed |
| 81 | Excavating in trenches , n.exc 1.5 m wide and n.exc 1.5 m depth for foundation etc or for shafts, wells, cesspits ,manhole pier hole, laying of cables, pipes etc n.exc 10 sqm on plan and n.exc 1.5m in depth and getting out in any kind of soilNote : Manual excavation to be done. During excavation if any damage occured to existing cable any type/ water pipe line, it will be contractor responsibilty to get it repair and make functional by providing jointing kit etc without any extra cost. Contractor has to repair it within 24 hrs so that essential service can not be effected due to such damage.If contractor fails to repair it within 24 hrs penalty @ Rs 500/- will be charged to contractor. In this GE decision will be final, conclusive and binding. |
| 82 | Removing surplus excavated spoil/earth to a distance not exceeding 50 M and depositing where directed at a level not exceeding 1.5 M above the starting point complete all as specified and as directed by Engr-in-Charge. |
| 83 | Returning filling in soft /loose excavated soil including spreading, levelling, watering and well ramming in layers not exceeding 25 cm thick complete all as specified and as directed by Engr-in-Charge. |
| 84 | M&L for sand filling under floors or in foundations including watering and consolidation complete all as specified and directed by Engr-in-Charge. |
| 85 | M&L for PCC type D-2 1:4:8 (using 40 mm graded stone aggregate) as foundation and mass filling complete all as specified and directed by Engr-in-Charge. |
| 86 | M&L for RCC design Mix M-25 using 20mm graded aggregate as in foundations, including rafts,footings, foundation beams;plinth beams; bases for columns, etc. basement slabs, under-reamed piles and mass concrete complete all as specified and directed by Engr-in-Charge. |
| 87 | M&L for design Mix M-25 using 20mm stone aggregate Beams, cantilevers, bressummers, lintels over 1.5m span complete all as specified and directed by Engr-in-Charge. |
| 88 | M&L for M-25 Design mix using 20mm stone aggregate Columns, pillars, piers, posts and struts complete all as specified and directed by Engr-in-Charge. |
| 89 | M&L for Steel Centering and shuttering including strutting, propping etc. and removal of form to sides of pillars, posts, struts, piers, columns and stanchions for fair finished surface of concrete Complete all as specified and directed. |
| 90 | M&L for Steel Centering and shuttering including strutting, propping etc. and removal of form to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter |
| 91 | M&L for Steel Centering and shuttering including strutting, propping etc. and removal of form to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including sup- ports, overhangs, etc. also splays between floors and beams, etc. for fair finished surface of concrete, complete all as specified and directed. |
| 92 | M&L for PCC 1:2:4 type B1 (20mm graded aggregate) as in coping including use and removal of necessary formwork all as specified and directed by Engr-in-Charge. |
| 93 | M&L Preparation of newly plastered surfaces of wall and applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior alkali resistance primer applied @ 0.90 litre/ 10 sqm over wall care putty new surfaces. on external surface as directed by Engineer-in-charge |
| 94 | M&L for Providing precast cement concrete type B-0 1:2:4 with (using 12.5 mm graded aggregate) louvres and jallies, 25mm thick (measured solid), including all mouldings but excluding frame, set in CM 1:4 complete all as specified and directed by Engr-in-Charge. |
| 95 | Mild steel bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clip complete all as specified and directed by Engr-in-Charge. |
| 96 | S&F TMT reinforcement bar, conforming to Fe-500, 5mm dia and upto and including 10mm dia in stirrups, spacers and binders, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends as binding with and including mild steel wire (Annealed) not less than 0.9mm dia or securing with clips all as specified. |
| 97 | S&F Framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing (FE 410-W-Gde-250A) complete all as specified and directed by Engr-in-Charge. |
| 98 | Taking down carefully aluminium/Copper conductor point wiring (light , fan, socket or powr) complete including fittings such as switches, ceiling rose, pendents, regulators sockets etc and removing (except those to be reused shall be kept in safe custody at the site) and making good disturbed surfaces of walls, floors etc tomatch with the existing completeall as specified and directed. Please Enable Macros to View BoQ information |
| 99 | Taking down carefully aluminium/Copper conductor point wiring (light , fan, socket or powr) complete including fittings such as switches, ceiling rose, pendents, regulators sockets etc and removing (except those to be reused shall be kept in safe custody at the site) and making good disturbed surfaces of walls, floors etc tomatch with the existing completeall as specified and directed. Please Enable Macros to View BoQ information |