| 1 | Providing, laying, testing & commissioning of 'C' class heavy duty MS pipe conforming to IS 1239/Class -II of IS: 3589 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required : 200 mm Dia (wall thickness 6.3 mm) DSR 27.7.9 |
| 2 | Providing, laying, testing & commissioning of 'C' class heavy duty MS pipe conforming to IS 1239/Class -II of IS: 3589 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required : 150 mm Dia (wall thickness 6.3 mm) DSR 27.7.8 |
| 3 | Providing, laying, testing & commissioning of 'C' class heavy duty MS pipe conforming to IS 1239/Class -II of IS: 3589 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required : 100 mm Dia (wall thickness 6.3 mm) DSR 27.7.7 |
| 4 | Providing, laying, testing & commissioning of 'C' class heavy duty MS pipe conforming to IS 1239/Class -II of IS: 3589 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required : 80 mm Dia (wall thickness 6.3 mm) DSR 27.7.6 |
| 5 | Providing, laying, testing & commissioning of 'C' class heavy duty MS pipe conforming to IS 1239/Class -II of IS: 3589 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required : 50 mm Dia (wall thickness 6.3 mm) DSR 27.7.4 |
| 6 | Providing, laying, testing & commissioning of 'C' class heavy duty MS pipe conforming to IS 1239/Class -II of IS: 3589 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required : 25 mm Dia (wall thickness 6.3 mm) DSR 27.7.1 |
| 7 | Supplying, fixing, testing and commissioning ofn butterfly valve of PN 1.6 rating with bronze/gunmetalseat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required 150 mm dia DSR 27.11.6 |
| 8 | Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetalseat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required 100 mm dia DSR 27.11.5 |
| 9 | Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetalseat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required 80 mm dia DSR 27.11.4 |
| 10 | Providing, installation, testing and commissioning of non-return valve of following sizes confirming to IS: 5312 complete with rubber gasket, GI bolts, nuts, washers etc.as required : 150 mm dia DSR 27.14.7 |
| 11 | Providing, installation, testing and commissioning of non-return valve of following sizes confirming to IS: 5312 complete with rubber gasket, GI bolts, nuts, washers etc.as required : 100 mm dia DSR 27.14.5 |
| 12 | Providing, installation, testing and commissioning of non-return valve of following sizes confirming to IS: 5312 complete with rubber gasket, GI bolts, nuts, washers etc.as required : 80 mm dia DSR 27.14.4 |
| 13 | Supplying, fixing, testing & commissioning of double flanged sluice valve of rating PN 1.6 with non rising spindle, bronze/gun metal seat, ISI marked complete with nuts, bolts, washers, gaskets and conforming to IS 780 of following sizes as required 200 mm Dia DSR 27.12.7 |
| 14 | Supplying, fixing, testing & commissioning of double flanged sluice valve of rating PN 1.6 with non rising spindle, bronze/gun metal seat, ISI marked complete with nuts, bolts, washers, gaskets and conforming to IS 780 of following sizes as required 150 mm Dia DSR 27.12.6 |
| 15 | Providing, installation, testing and commissioning of stainless steel Y-strainer fabricated out of 1.6 mm thick stainless steel, Grade 304, sheet with 3 mm dia holes with stainless steel flange 200 mm dia DSR 27.15.4 |
| 16 | Supplying and fixing first-aid Hose Reel with MS construction spray painted in post office red, conforming to IS 884 complete with the following as required. (a) 20 mm nominal internal dia water hose thermoplastic (Textile reinforced) type -2 as per IS: 12585 (b) 20 mm nominal internal dia gun metal globe valve & nozzle. (c) Drum and brackets for fixing the equipmets on wall. (d) Connections from riser with 25 mm dia stop gun metal valve & M.S. Pipe and socket. 30 m DSR 27.17.1 |
| 17 | Supplying Installation testing & Commissioning of 25 mm Air Release valve gunmental having rubber ball and with 25 mm BSP threaded male inlet including necessary accessories and connections complete in all respect. |
| 18 | Supplying Installation testing & Commissioning of SS/GM/Ball Valve 25 mm dia complete. |
| 19 | SITC of Hose Box of 18 SWG MS Sheet with glass fronted door to accommodate 2 nos. RRL hose & 1 no. SS Branch Pipe with nozzle (External/ Internal) Size 800x600x400 |
| 20 | Supplying and fixing 63 mm dia, 15 m long RRL hose pipe with 63 mm dia male and female couplings duly bound with GI wire, rivets etc.conforming to IS 636 (type-A) as required Stainless Steel (Grade 304)Stainless Steel DSR 27.16.2 |
| 21 | Supplying & fixing 63 mm dia gun metal short branch pipe with 20 mm nominal internal diameter size nozzle conforming to IS 903 suitable for instantaneous connection to interconnect hose pipecoupling as required:Stainless Steel Stainless Steel (Grade 304) DSR 27.18.2 |
| 22 | (a) Supplying, installation, testing and commissioning of electric driven terrace pump conforming to IS 12469: 2019 suitable for automatic operation and consisting of following, complete in all respects, as required: (Terrace Pump) 450 Ipm at 35 m Head 450 Ipm at 35 m Head DSR 27.4.2 |
| 23 | Supplying and fixing air vessel made of 250 mm dia, 8 mm thick MS sheet, 1200 mm in height with air release valve on top and flanged connection to riser, drain arrangement with 25 mm dia gun metal wheel valve with required accessories, pressure gauge and painting with synthetic enamel paint of approved shade as required. DSR 27.20 |
| 24 | Supply Installation testing and commissioning of Pressure Gauge. |
| 25 | Supplying and fixing of fire brigade connection of cast iron body with gun metal male instantaneous inlet couplings complete with cap and chain as reqd. for suitable dia MS pipe connection conforming to IS904 as required: 4 way - 150 mm dia M.S. Pipe DSR 27.19.2 |
| 26 | SITC of Automatic panel of tarrace pump suitable for 5 HP tarrace pump. |
| 27 | S/L of fixiing of one number PVC Insulated and PVC sheathed/XLPE power cable of 1.1 KV grade of following size on wall surface as required. 16 sqmm 4 core |
| 28 | Supply and laying of Al. Conductor PVC Insulated armoured served sheathod cables 1100V grade at a depth of 750mm below ground level over a cushion of 75mm thick sand all around and protected with burnt bricks on sides and on top. On surface the cable run shall ne fixed on M.S Clamps etc of suitable size or as directed by Enginner in Charge complete in all respect inculuding excavation and refilling. The armouning of the cable shall be properly connected with the earth conductor by clamps etc. 150 sqmm 3-1/2 core DSR 20.1.16 |
| 29 | Supply and laying of Al. Conductor PVC Insulated armoured served sheathod cables 1100V grade at a depth of 750mm below ground level over a cushion of 75mm thick sand all around and protected with burnt bricks on sides and on top. On surface the cable run shall ne fixed on M.S Clamps etc of suitable size or as directed by Enginner in Charge complete in all respect inculuding excavation and refilling. The armouning of the cable shall be properly connected with the earth conductor by clamps etc. 95 sqmm 3-1/2 core DSR 20.1.14 |
| 30 | S/F of 200 AMP 4 pole changeover switch with angle iron frame complete. |
| 31 | S/L of 1800mmX900mmX12mm thick chequered rubber matting of tested quality |
| 32 | Earthing with G.I. earth pipe 4.5 Meter long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/coke and salt as required. DSR 5.2 |
| 33 | Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm) DSR 5.9 |
| 34 | Providing & fixing of pressure switch in M.S. pipe line including connection etc. as required. DSR 27.22 |
| 35 | Supplying and fixing Single headed external yard hydrant valve with 1 No. 63 mm dia instantaneous FM Gunmetal/Stainless Steel coupling and cast iron wheel, ISI marked, conforming to IS 5290 (type A) with blank Gunmetal/Stainless Steel cap and chain as required : Single headed Stainless steel DSR 27.10.2 |
| 36 | Supply, Installation, Testing & Commissioning of Terrace PVC tank having capacity 5000 Ltrs. @ 9.00 Per Ltr. |
| 37 | Making RCC Plate form for putting PVC Tank Size 2m Dia and 30cm Height. |
| 38 | S.I.T.C of Tubewell complete in all respect with boring 5 H.P submarsible pump control pannel including fitting testing etc.(L/S) |
| 39 | SITC of (i) one pump house size 5.0 mitr.x 4.5 Mtr.x 3.0 mtr. Approx. (ii). Undergound RCC Water Tank having 50,000 Ltr. Capacity Approx. |
| 40 | (a) Supplying, installation, testing and commissioning of Electric driven Main Fire Pump conforming to IS 12469: 2019 suitable for automatic operation and consisting of following, complete in all respects, as required : (b) Horizontal type, multistage, centrifugal, split casing pump of cast iron body & bronze impeller with stainless steel shaft, mechanical seal as required. (c) Suitable HP Squirrel cage induction motor, TEFC, synchronous speed 1500 RPM, suitable for operation on 415 volts, 3 phase 50 Hz, AC supply with IP 55 protection for enclosure, horizontal foot mounted type with Class-'F' insulation, conforming to IS-12615: 2018. (d) M.S. fabricated Common base plate, coupling, coupling guard, foundation bolts etc. as required. (e)Suitable cement concrete foundation duly plastered with anti vibration pads. 1620 lpm at 70 m Head DSR 27.1.8 |
| 41 | (a) Supplying, installation, testing and commissioning of diesel engine driven main fire pump conforming to IS 12469: 2019 suitable for automatic operation and consisting of following, complete in all respects, as required : (Diesel Driven Pump) Horizontal split Casing type,centrifugal, multistage, pump of cast iron body & bronze impeller with stainless steel shaft, Mechanical seal at specified flow of 2850 lpm at 88 meter head confirming to IS 1520.Suitable HP 1500 RPM, 4 stroke, cold starting type Diesel Engine with Heat Exchanger confirming to relevant BIS & IS Standards, complete with all required accessories/system, fuel oil filter ,lubricant oil pump with filter, 1 set Starting batteries of 180AH capicity each with suitable angle iron stand,engine starting panel havng all the controls meters. techo meter,hour meter, starting switch with keys for manual starting, auto starting mechanism, 12/24 volt electric starting equipment, Deisel tank for 8 hrs continuous running for Diesel Engine having minimum capicity of 200 Ltrs. (Tank made out of 3mm thick M.S.Sheet with filling cap, drain cock, diesel indicator duly mounted on M.S.angle) exhaust pipe of minimum 10 mtr. length, duly insulated with 50 mm thick glass wool with 1.0 mm.thick alluminium sheet cladding, exuast reidential silencer,stop solenold for auto stop in the event of fault with audio indications, painting etc. as required.M.S fabricated Common base frame,flexible coupling, coupling guard, foundation bolt & pressure gauge with valve etc.Suitable cement concrete foundation duly plastered, with anti vibration pads etc. complete as per detailed specifications. 1620 lpm at 70 m Head. DSR 27.2.8 |
| 42 | (a) Supplying, installation, testing and commissioning of electric driven pressurisation pump conforming to IS 12469: 2019 suitable for automatic operation and consisting of following, complete in all respects, as required : (Jockey Pump)Horizontal type, centrifugal & suction type, pump of cast iron body & bronze impeller with stainless steel shaft Mechanical seal, gland packing & flow of 180 lpm at 88 Mtr. Head confirming to IS:-1520. Common base frame fabricated out of M.S channel of suitable able size flexible coupling, coupling guard, foundation bolt & pressure gauge with valve etc.Suitable cement concrete foundation duly plastered, with anti vibration pads etc. complete as per detailed specifications.180 lpm at 88 m Head. DSR 27.3.1 |
| 43 | INCOMING 400A, 50kA 4 Pole MCCB, Ics=100% lcu rating Digital Voltmeter 0-500V with selector switch Ammeter (0-630 A) with selector swtich & CTs etc. LED type RYB phase indicating lamps, ON, OFF, trip indicating lamps Set of Copper Bus Bar 500Amps OUTGOING ( Note : All outgoing feeders for pumps should have digital Ammeter with selector switches, and LED type ON, OFF, trip indicating lamps)MAIN FIRE PUMP 200 A, 50kA TPN MCCB, Ics=100% Icu, with fully automatic Star/Delta starter suitable for 75 hp pump with overload protection, current sensing type single phase preventor complete with all acceessories and internal wiring required for automatic operation, selector switch for local/remote, auto/manual/OFF operation. JOCKEY PUMP 100A, 50kA TPN MCCB, Ics=100% lcu, with Suitable HP fully automatic Star/Delta starter with overload protection, current sensing type single phase preventor complete with all acceessories and internal wiring required for automatic operation, selector switch for local/remote, auto/manual/OFF operation.DIESEL ENGINE CONTROL Control for diesel engine comprising -Automatic/ Manual selctor switch & 3 attempts starting device, timers and relays as required, push buttons, start/stop in manual mode Indicating lamp for high/ Low Lub. Oil pressure, High Water Temp and Engine on indication Battery charger suitbale for 12V/24 V DC with boost and trickle selector switch, 0-30 V DC volt meter, and 0-20 A DC Ammeter All standard relays and accessories for automatic operation of diesel engine SYSTEM CONTROLLERDesigning, Supply, Installation, esting and commissioning of system controller to control operation of main electric fire pump, diesel pump, Pressurization pump, Terrace pump in sequence as per specification consisting of relays, timers. Sensors, annunciation window for fault indication, complete as per specification DSR 27.5.2 |
| 44 | SITC Automatic priming arrangement for all fire pumps including necessary pipe, fitting, water level controller, 1 HP pump, auto starter gate valve NRV's etc complete. |
| 45 | Supply & fixing of CO2 type fire extinguisher, 4.5 kg. capacity (ISI Marked IS:2878 & TAC approved) comlete with initial charge and wall bracket, along with supply of all materials and labour for proper completion of work. |
| 46 | Supply & fixing of fire extinguisher, ABC Type 4.00 kg. capacity (ISI Marked IS:15683 & TAC approved) comlete with initial charge and wall bracket, along with supply of all materials and labour for proper completion of work. |
| 47 | Supply & fixing of ABC Type Modular Auotomatic Fire Extinguisher 5.00 kg. capacity (ISI Marked IS : 15683 CM/L-8886112 approved) comlete with Ceiling mounted as required. |
| 48 | Supply & fixing of fire extinguisher, Water CO2 Type 09 Ltr. capacity (ISI Marked IS:15683 & TAC approved) comlete with initial charge and wall bracket, along with supply of all materials and labour for proper completion of work. |
| 49 | Breaking of road/RCC/PCC and digging of trench in soft soil upto a depth of 1 mts and re filling of soil after laying of pipes and disposal of excavated excess soil and finishing the top layer with PCC 150 mm |
| 50 | Supplying, installation, testing and commissioning of micro processor based intelligent addressable main fire alarm panel, central processing unit with the following loop modules and capable of supporting not less than 240 devices (including detectors) and minimum 120 detectors per loop and loop length up to 2 km, network communication card, minimum 320 character graphics/ LCD display with touch screen or other keypad and minimum 4000 events history log in the non volatile memory (EPROM), power supply unit (230 ± 5 % V, 50 hz), 48 hrs back-up with 24 volt sealed maintenance free batteries with automatic charger The panel shall have facility to connect printer to printout logand facility to have seamless integration with analog/digital voice evacuation system (which is part of the schedule of work under SH: PA System) and shall be complete with all accessories . The panel shall be compatible for IBMS systemwith open protocol BACnet/ Modbus over IP complete as per specifications. Ten Loop Panel DSR 28.2.1.1 |
| 51 | Supplying, installation, testing and commissioning of micro processor based intelligent addressable main fire alarm panel, central processing unit with the following loop modules and capable of supporting not less than 240 devices (including detectors) and minimum 120 detectors per loop and loop length up to 2 km, network communication card, minimum 320 character graphics/ LCD display with touch screen or other keypad and minimum 4000 events history log in the non volatile memory (EPROM), power supply unit (230 ± 5 % V, 50 hz), 48 hrs back-up with 24 volt sealed maintenance free batteries with automatic charger The panel shall have facility to connect printer to printout logand facility to have seamless integration with analog/digital voice evacuation system (which is part of the schedule of work under SH: PA System) and shall be complete with all accessories . The panel shall be compatible for IBMS systemwith open protocol BACnet/ Modbus over IP complete as per specifications. Two Loop Panel DSR 28.2.1.2 |
| 52 | Supplying, installation, testing & commissioning of intelligent addressable Heat and smoke Combined (Multi Detector) complete with mounting base, complete as required. |
| 53 | Supplying Installation testing & Commissioning of Addressable Manual Call Point complete with base as required. DSR 28.2.14 |
| 54 | Supplying Installation testing & Commissioning of Addressable horn cum strobe complete with base as required. DSR 28.2.15 |
| 55 | Supplying Installation testing & Commissioning of fault isolator complete with base as required. DSR 28.2.7 |
| 56 | Supplying & laying of 2x1.5 sqmm fire alarm armoured cable,600/1000V rated with annealed copper conductor havingXLPE insulation, steel wire armouring & FRLS/HFFR outersheath complete as required. DSR 28.5.2 |
| 57 | Supplying Laying testing & Commissioning of 6 corex 1.5 sq.mm single standard copper conductor, PVC insulated armored cable. Please Enable Macros to View BoQ information |