| Sl. No. | Item Description |
| 1 | PART (A) |
| 2 | Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth up to 30 cm measured at a height of 1 m above ground level and removal of rubbish up to a distance of 50 m outside the periphery of the area cleared. |
| 3 | Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. All kinds of soil. |
| 4 | Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in-charge. All kinds of soil |
| 5 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :1:2:4 (1 cement : 2 coarse sand (zone-III) : 4 graded stone aggregate 20 mm nominal size). |
| 6 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:3:6 (1 Cement : 3 coarse sand (zone-III) : 6 graded stone aggregate 20 mm nominal size). |
| 7 | Brick work with non-modular FALG bricks confirming to IS: 12894, class designation 7.5 average compressive strength etc. complete in all respect in foundation and plinth: In cement mortar 1:6 (1 cement : 6 coarse sand) |
| 8 | Brick work with non-modular FALG bricks confirming to IS: 12894, class designation 7.5 average compressive strength etc. complete in superstructure above plinth level upto floor V level: In cement mortar 1:6 (1 cement : 6 coarse sand) |
| 9 | Half Brick work with non-modular FALG bricks confirming to IS: 12894, class designation 7.5 average compressive strength etc. complete in all respect in foundation and plinth: In cement mortar 1:4 (1 cement : 4 coarse sand) |
| 10 | 12 mm cement plaster of mix :1:6 (1 cement: 6 fine sand) |
| 11 | 6 mm cement plaster of mix :1:3 (1 cement : 3 fine sand) |
| 12 | Neat cement punning. |
| 13 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes.110 mm diameter |
| 14 | Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion.Bend 87.5°-110 mm bend |
| 15 | Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion.Shoe (Plain)-110 mm Shoe |
| 16 | Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with M.S. screws of required length, including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete.110 mm |
| 17 | Providing and fixing soil, waste and vent pipes :100 mm dia-Sand cast iron S&S pipe as per IS: 1729 |
| 18 | Providing and fixing trap of self cleansing design with screwed down or hinged grating with or without vent arm complete, including cost of cutting and making good the walls and floors :100 mm inlet and 100 mm outlet-Sand Cast Iron S&S as per IS: 1729 |
| 19 | Providing and fixing bend of required degree with access door, insertion rubber washer 3 mm thick, bolts and nuts complete.100 mm dia-Sand cast iron S&S as per IS - 3989 |
| 20 | Providing and fixing double equal plain junction of required degree.100x100x100x100 mm-Sand cast iron S&S as per IS - 1729 |
| 21 | Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade :New work (two or more coats) over and including water thinnable priming coat with cement primer |
| 22 | Providing and fixing 100 mm sand cast Iron grating for gully trap. |
| 23 | Providing and filling the joints with spun yarn, cement slurry and cement mortar 1:2 ( 1 cement : 2 fine sand) in S.C.I./ C.I. Pipes :100 mm dia pipe |
| 24 | Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in - charge. Nominal concrete 1:3:6 or richer mix (i/c equivalent design mix) |
| 25 | Dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead. |
| 26 | Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge.In cement mortar |
| 27 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. |
| 28 | Providing and fixing M.S. holder bat clamps of approved design to C.I. or S.C.I. rain water pipes embedded in and including cement concrete blocks 10x10x10 cm of 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) and cost of cutting holes and making good the walls etc. :100 mm diameter |
| 29 | Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement, including cement slurry, but excluding the cost of nosing of steps etc. complete. 25 mm thick with 12.5 mm nominal size stone aggregate |
| 30 | Grading roof for water proofing treatment with Cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) |
| 31 | White washing with lime to give an even shade :Old work (one or more coats) |
| 32 | Finishing walls with Acrylic Smooth exterior paint of required shade: Old work (Two or more coat applied @ 1.67 ltr/ 10 sqm) on existing cement paint surface |
| 33 | Distempering with 1st quality acrylic distember (Ready mix) having VOC content less than 50 grams/ litre of approved brand and manufacture to give an even shade Old work (one or more coats) |
| 34 | Finishing walls with water proofing cement paint of required shade :Old work (one or more coats @ 2.20 kg/10 sqm) complete. |
| 35 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade : One or more coats on old work |
| 36 | Applying priming coat: With ready mixed pink or Grey primer of approved brand and manufacture on wood work (hard and soft wood) |
| 37 | Welding by gas or electric plant including transportation of plant at site etc. complete. |
| 38 | Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. |
| 39 | Renewing glass panes, with putty and nails wherever necessary including racking out the old putty: Float glass panes of thickness 4 mm |
| 40 | Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer.Using flats 30x6mm for diagonal braces and central cross piece |
| 41 | Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters:30 mm thick including ISI marked Stainless Steel butt hinges with necessary screws |
| 42 | Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters:25 mm thick (for cupboard) including ISI marked nickel plated bright finished M.S. piano hinges with necessary screws |
| 43 | Providing and fixing aluminum U beading of required size to Pre-laminated/ flush door shutter, including fixing etc. complete as per direction of Engineer-in-charge. |
| 44 | Providing and fixing ISI marked oxidised M.S. sliding door bolts with nuts and screws etc. complete :250x16 mm |
| 45 | Providing and fixing ISI marked oxidised M.S. tower bolt black finish, (Barrel type) with necessary screws etc. complete : 250x10 mm |
| 46 | Providing and fixing ISI marked oxidised M.S. tower bolt black finish, (Barrel type) with necessary screws etc. complete : 150x10 mm |
| 47 | Providing and fixing ISI marked oxidised M.S. handles conforming to IS:4992 with necessary screws etc. complete : 125 mm |
| 48 | Providing and fixing ISI marked oxidised M.S. handles conforming to IS:4992 with necessary screws etc. complete : 100 mm |
| 49 | Providing, hoisting and fixing above plinth level up to floor five level precast reinforced cement concrete work in string courses, bands, copings, bed plates, anchor blocks, plain window sills and the like, including the cost of required centering, shuttering but, excluding cost of reinforcement, with 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) : 3 graded stone aggregate 20 mm nominal size). |
| 50 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level.Cold twisted bars |
| 51 | Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length ( hold fast lugs or dash fastener shall be paid for separately).Sal wood |
| 52 | Providing and fixing aluminium sliding door bolts, ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868), transparent or dyed to required colour or shade, with nuts and screws etc. complete :250x16 mm |
| 53 | Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete :250x10 mm |
| 54 | Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete : 150x10 mm |
| 55 | Providing and fixing aluminium handles, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete : 125 mm |
| 56 | Providing and fixing aluminium handles, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete : 100 mm |
| 57 | Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. |
| 58 | Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3kg/sqm including grouting the joints with white cement and matching pigments etc., complete.Size of Tile 600x600 mm |
| 59 | Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3kg/sqm including pointing the joints with white cement and matching pigment etc., complete. |
| 60 | Taking out doors, windows and clerestory window shutters (steel or wood) including stacking within 50 metres lead :Of area 3 sq. metres and below |
| 61 | Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead : Of area 3 sq. metres and below |
| 62 | Providing and fixing to existing door frames.25 mm thick PVC flush door shutters made out of a one piece Multi chamber extruded PVC section of the size of 762 mm X 25 mm or less as per requirement with an average wall thickness of 1 mm (± 0.3 mm). PVC foam end cap of size 23x10 mm are provided on both vertical edges to ensure the overall thickness of 25 mm. M.S. tube having dimensions 19 mm x 19 mm and 1.0 mm (± 0.1 mm) is inserted along the hinge side of the door. Core of the door shutter should be filled with High Density Polyurethane foam. The Top & Bottom edges of the shutter are covered with an end-cap of the size 25 mm X 11 mm. Door shutter shall be reinforced with special polymeric reinforcements as per manufacturer’s specification and direction of Engineer-in-charge to take up necessary hardware and fixtures. Stickers indicating the locations of hardware will be pasted at appropriate places |
| 63 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. |
| 64 | Removing white or colour wash by scrapping and sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete |
| 65 | Finishing walls with Acrylic Smooth exterior paint of required shade :New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) |
| 66 | Providing and fixing aluminium hanging floor door stopper, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour and shade, with necessary screws etc. complete.Twin rubber stopper |
| 67 | Providing and fixing aluminium extruded section body tubular type universal hydraulic door closer (having brand logo with IS : 3564, embossed on the body, door weight upto 36 kg to 80 kg and door width from 701 mm to 1000 mm), with double speed adjustment with necessary accessories and screws etc. complete. |
| 68 | Providing and fixing double action hydraulic floor spring of approved brand and manufacture conforming to IS : 6315, having brand logo embossed on the body / plate with double spring mechanism and door weight upto 125 kg, for doors, including cost of cutting floors, embedding in floors as required and making good the same matching to the existing floor finishing and cover plates with brass pivot and single piece M.S. sheet outer box with slide plate etc. complete as per the direction of Engineer-in-charge. With stainless steel cover plate minimum 1.25 mm thickness |
| 69 | Providing and fixing flat pressed 3 layer particle board medium density exterior grade (Grade I) or graded wood particle board IS : 3087 marked, to frame, backing or studding with screws etc. complete (Frames, backing or studding to be paid separately): 12 mm thick |
| 70 | Providing and fixing flat pressed 3 layer particle board medium density exterior grade (Grade I) or graded wood particle board IS : 3087 marked, to frame, backing or studding with screws etc. complete (Frames, backing or studding to be paid separately): 18 mm thick |
| 71 | Providing gola 75x75 mm in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 stone aggregate 10 mm and down gauge), including finishing with cement mortar 1:3 (1 cement : 3 fine sand) as per standard design :In 75x75 mm deep chase |
| 72 | Providing and applying fibre reinforced elastomeric liquid water proofing membrane with resilient acrylic polymers having Sun Reflectivity Index (SRI) of 105 on top of concrete roof in three coats @10.76 litre/ 10 sqm. One coat of selfpriming of elastomeric waterproofing liquid (dilution with water in the ratio of 3:1) and two coats of undiluted elastomeric waterproofing liquid (dry film thickness of complete application/ system not less than 500 microns). Theoperation shall be carried out after scrapping and properly cleaning the surface to remove loose particles with wire brushes, complete in all respect as per thedirection of Engineer-in-Charge. |
| 73 | Providing and fixing fly proof galvanized M.S. wire gauge to windows and clerestory windows using wire gauge with average width of aperture 1.4 mm in both directions with wire of dia 0.63 mm all complete.With 12 mm mild steel U beading |
| 74 | Providing and fixing panelled or panelled and glazed shutters for doors, windows and clerestory windows, including ISI marked M.S. pressed butt hinges bright finished of required size with necessary screws, excluding panelling which will be paid for separately, all complete as per direction of Engineer-in-charge.Kiln seasoned and chemically treated hollock wood-30 mm thick shutters |
| 75 | Providing and fixing panelling or panelling and glazing in panelled or panelled and glazed shutters for doors, windows and clerestory windows (Area of opening for panel inserts excluding portion inside grooves or rebates to be measured). Panelling for panelled or panelled and glazed shutters 25 mm to 40 mm thick :Kiln seasoned and chemically treated hollock wood |
| 76 | Providing 40x5 mm flat iron hold fast 40 cm long including fixing to frame with 10 mm diameter bolts, nuts and wooden plugs and embedding in cement concrete block 30x10x15cm 1:3:6 mix (1 cement : 3 coarse sand : 6 graded stone aggregate 20mm nominal size). |
| 77 | Providing and fixing oxidised M.S. hasp and staple (safety type) conforming to IS : 363 with necessary screws etc. complete :150 mm |
| 78 | Providing and fixing bright finished 100 mm mortice lock with 6 levers without pair of handles of approved quality for aluminium door, with necessary screws etc complete as per direction of Engineer- in-charge. |
| 79 | Providing and fixing ISI marked oxidised M.S. pressed butt hinges with necessary screws etc. complete.100x58x1.90 mm |
| 80 | Providing and fixing 18 mm thick, 150 mm wide pelmet of flat pressed 3 layer or graded wood particle board medium density grade I, IS : 3087 marked, including top cover of 6 mm commercial ply wood conforming to IS: 303 BWR grade, nickel plated M.S. pipe 20 mm dia ( heavy type) curtain rod with nickel plated brackets, including fixing with 25x3 mm M.S. flat 10 cm long fixed to pelmet with hollock wood cleats of size 100 mm x 40 mm x 40 mm on both inner side of pelmet and rawl plugs 75 mm long etc. all complete. |
| 81 | Providing and fixing nickel plated M.S. pipe curtain rods with nickel plated brackets :20 mm dia (heavy type) |
| 82 | Providing and fixing 50 mm bright finished brass cup board or wardrobe knob of approved quality with necessary screws. |
| 83 | CARRIAGE OF MATERIALS By Mechanical Transport including loading, unloading and stacking of earth and lead upto 1.00KM |
| 84 | CARRIAGE OF MATERIALS By Mechanical Transport including loading, unloading and stacking of Lime, moorum, building rubbish and lead upto 1.00KM |
| 85 | 12 mm cement plaster finished with a floating coat of neat cement of mix :1:4 (1 cement: 4 fine sand) |
| 86 | Providing and laying 60mm thick faciory made cement concrete interlocking paver block of M -30 grade made by block making machine with strong vibratory compaction, of approved s;ze, design & shape, laid in required colour and pattern over and including 50mm thick compacted bed of coarse sand, filling the joints with line sand etc. all complete as per the direction of Engineer-in-charge. |
| 87 | Renewal of old putty of glass panes (length) |
| 88 | Re-lettering with black Japan paint of approved brand and manufacture. |
| 89 | Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth. |
| 90 | Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) :25 mm thick |
| 91 | Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels.Granite of any colour and shade-Area of slab over 0.50 sqm |
| 92 | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete.Fixed to steel windows by welding |
| 93 | Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) :For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately)-Anodised aluminium (anodised transparent or dyed to required shade according to IS: 1868, Minimum anodic coating of grade AC 15) |
| 94 | Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of Engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item):With float glass panes of 4.0 mm thickness |
| 95 | Surface dressing of the ground including removing vegetation and in- equalities not exceeding 15 cm deep and disposal of rubbish, lead up to 50 m and lift up to 1.5 m.All kinds of soil |
| 96 | Repairs to plaster of thickness 12 mm to 20 mm in patches of area 2.5 sq. meters and under, including cutting the patch in proper shape, raking out joints and preparing and plastering the surface of the walls complete, including disposal of rubbish to the dumping ground, all complete as per directions of Engineer-In-Charge.With cement mortar 1:4 (1 cement : 4 fine sand) |
| 97 | Dismantling roofing including ridges, hips, valleys and gutters etc., and stacking the material within 50 metres lead of:G.S. Sheet |
| 98 | Providing corrugated G.S. sheet roofing including vertical / curved surface fixed with polymer coated J or L hooks, bolts and nuts 8 mm diameter with bitumen and G.I. limpet washers or with G.I. limpet washers filled with white lead, including a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete (up to any pitch in horizontal/ vertical or curved surfaces), excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required.0.63 mm thick with zinc coating not less than 275 gm/ m² |
| 99 | Providing and fixing white vitreous china water closet squatting pan (Indian type) :Orissa pattern W.C. pan of size 580x440 mm |
| 100 | Providing and fixing white vitreous china pedestal type (European type/ wash down type) water closet pan. |
| 101 | Providing and fixing solid plastic seat with lid for pedestal type W.C. pan complete :White solid plastic seat with lid |
| 102 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :Two or more coats on new work |
| 103 | Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+ 0.05 %) total coated thickness with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineer- in-charge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. |
| 104 | Refixing old glass panes with putty and nails |
| 105 | Fixing old glass panes with wooden fillets (excluding cost of fillets) |
| 106 | Fixing of old wind tie with new fittings including painting two or more coats withanticorrosive bitumastic paint of approved brand & manufacturer over andincluding priming coat of ready mixed zinc chromate yellow primer of approvedbrand. |
| 107 | Taking out existing wooden door shutter, repair by cutting, painting etc. andrefixing of repaired door shutters to existing door frames, including replacement ofhinges with screws, etc. as required, all complete as per the direction of theEngineer-in-charge. |
| 108 | Cleaning of grass and removal of the rubbish upto a distance of 50m outside the periphery of the area cleared. |
| 109 | Providing and fixing G.I. pipes complete with G.I. fittings and clamps, i/c cutting and making good the walls etc. 15 mm dia nominal bore |
| 110 | Providing and fixing G.I. pipes complete with G.I. fittings and clamps, i/c cutting and making good the walls etc.20 mm dia nominal bore |
| 111 | Providing and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc.External work15 mm dia. nominal bore |
| 112 | Providing and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc.External work20 mm dia. nominal bore |
| 113 | Providing and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc.External work25 mm dia. nominal bore |
| 114 | Providing and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc.External work40 mm dia. nominal bore |
| 115 | Providing and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc.External work50 mm dia. nominal bore |
| 116 | Providing and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc.External work80 mm dia. nominal bore |
| 117 | Providing and fixing C.I. sluice valves (with cap) complete with bolts, nuts, rubber insertions etc. (the tail pieces if required will be paid separately) :Class II 100mm dia |
| 118 | Providing and fixing C.I. sluice valves (with cap) complete with bolts, nuts, rubber insertions etc. (the tail pieces if required will be paid separately) :Class II 150mm dia |
| 119 | Providing and fixing C.I. sluice valves (with cap) complete with bolts, nuts, rubber insertions etc. (the tail pieces if required will be paid separately) :Class II 200mm dia |
| 120 | Supplying pig lead at site of work. |
| 121 | Providing and fixing PTMT bib cock of approved quality and colour.15mm nominal bore, 86 mm long. Weighing not less |
| 122 | Providing and fixing PTMT pillar cock of approved quality and colour .15mm nominal bore, 107mm long. Weighing not less than 110 gms. |
| 123 | Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fitting arrangement of approved quality and colour.600mm long towel rail with total length of 645mm, width 78mm and effective height of 88mm, weighing not less than 190gms. |
| 124 | Waste coupling 31 mm dia of 79 mm length and 62mm breadth weighing not less than 45 gms |
| 125 | Waste coupling 38 mm dia of 83 mm length and 77mm breadth, weighing not less than 60 gms |
| 126 | Providing and fixing PTMT, push cock of approved quality and colour. 15 mm nominal bore, 80mm long. Weighing not less than 46 gms. |
| 127 | Providing and fixing PTMT shelf 440 mm long, 124 mm width and 36 mm height of approved quality and colour. Weighing not less than 300 gms. |
| 128 | Providing and fixing PTMT swivelling shower, 15mm nominal bore. Weighing not less than 40gms. |
| 129 | Providing and fixing brass bib cock of approved quality :15 mm nominal bore |
| 130 | Providing and fixing brass stop cock of approved quality :15 mm nominal bore |
| 131 | Providing and fixing brass stop cock of approved quality :20 mm nominal bore |
| 132 | Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :25 mm nominal bore |
| 133 | Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :40 mm nominal bore |
| 134 | Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :50 mm nominal bore |
| 135 | Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete :20 mm nominal bore |
| 136 | Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete :25 mm nominal bore |
| 137 | Providing and fixing uplasticised PVC connection pipe with brass unions : 15 mm nominal bore |
| 138 | Providing and fixing C.P. brass shower rose with 15 or 20 mm inlet :100 mm diameter |
| 139 | Providing and placing on terrace (at all floor levels) polyethylene water storage tank ISI : 12701 marked with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. Circular tank |
| 140 | Providing and fixing C.P. brass bib cock of approved quality conforming to IS:8931. 15 mm nominal bore. |
| 141 | Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS:8931. 15 mm nominal bore. |
| 142 | Providing and fixing white vitreous china flat back half stall urinal of size 580x380x350mm with white PVC automatic flushing cistern, with fittings, standard size C.P. brass flush pipe, spreaders with unions and clamps (all in C.P. brass) with waste fitting as per IS : 2556, C.I. trap with outlet grating and other couplings in C.P. brass including painting of fittings and cutting and making good the walls and floors wherever required :Range of two half stall urinals with 5 litre P.V.C. automatic flushing cistern. |
| 143 | Providing and fixing white vitreous china wash basin including making all connections but excluding the cost of fittings :Flat back wash basin of size 550x400mm. |
| 144 | Providing and fixing kitchen sink including making all connections excluding cost of fittings.White glazed fire clay sink of size 600x450x250mm. |
| 145 | Providing and fixing white vitreous china pedestal for wash basin completely recessed at the back for the reception of pipes and fittings. |
| 146 | Providing and fixing P.V.C. low level flushing cistern with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete.10 litre capacity - White |
| 147 | Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete.32 mm dia |
| 148 | Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete.40 mm dia |
| 149 | Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. |
| 150 | Providing and fixing 600x120x5mm glass shelf with edges round of supported on anodised aluminium angle frame with C.P. brass brackets and guard rail complete fixed with 40 mm long screws, rawl plugs etc., complete. |
| 151 | Dismantling of flushing cistern of any size including stacking of useful materials near the site and disposal of unserviceable materials within 50 metres lead. |
| 152 | Making connection of G.I. distribution branch with G.I. main of following sizes by providing and fixing tee, including cutting and threading the pipe etc. complete :25 to 40 mm nominal bore |
| 153 | Making connection of G.I. distribution branch with G.I. main of following sizes by providing and fixing tee, including cutting and threading the pipe etc. complete :50 to 80 mm nominal bore |
| 154 | Providing and fixing G.I. Union in existing G.I. pipe line, cutting and threading the pipe and making long screws including excavation, refilling the earth or cutting of wall and making good the same complete wherever required :15 mm nominal bore. |
| 155 | Providing and fixing G.I. Union in existing G.I. pipe line, cutting and threading the pipe and making long screws including excavation, refilling the earth or cutting of wall and making good the same complete wherever required :20 mm nominal bore. |
| 156 | Providing and fixing G.I. Union in existing G.I. pipe line, cutting and threading the pipe and making long screws including excavation, refilling the earth or cutting of wall and making good the same complete wherever required :25 mm nominal bore. |
| 157 | Providing and fixing G.I. Union in existing G.I. pipe line, cutting and threading the pipe and making long screws including excavation, refilling the earth or cutting of wall and making good the same complete wherever required :40 mm nominal bore. |
| 158 | Providing and fixing G.I. Union in existing G.I. pipe line, cutting and threading the pipe and making long screws including excavation, refilling the earth or cutting of wall and making good the same complete wherever required :50 mm nominal bore. |
| 159 | Providing and fixing G.I. Union in existing G.I. pipe line, cutting and threading the pipe and making long screws including excavation, refilling the earth or cutting of wall and making good the same complete wherever required :80 mm nominal bore. |
| 160 | Providing lead caulked joints to spun iron or C.I. pipes and specials, including testing of joints but excluding the cost of pig lead :100 mm diameter pipe |
| 161 | Dismantling of C.I. sluice valve including stacking of useful materials within a lead of 50 metresUp to 150 mm diameter |
| 162 | Dismantling of C.I. sluice valve including stacking of useful materials within a lead of 50 metresAbove 150 mm diameter |
| 163 | Dismantling G.I. pipes (external work) including excavation and refilling trenches after taking out the pipes, manually/ by mechanical means including stacking of pipes within 50 metres lead as per direction of Engineer-in-charge :15 mm to 40 mm nominal bore |
| 164 | Dismantling G.I. pipes (external work) including excavation and refilling trenches after taking out the pipes, manually/ by mechanical means including stacking of pipes within 50 metres lead as per direction of Engineer-in-charge :Above 40 mm nominal bore |
| 165 | Providing and fixing Polyethelene-Aluminium-Polyethelene (PE-AL-PE) Composite Pressure Pipes conforming to IS - 15450, U.V. stabilized with carbon black having thermal stability for hot & cold water supply, capable to withstand temperature up to 80°C, including all special fittings of composite material (engineering plastic blend and brass inserts wherever required) e.g. elbows, tees, reducers, couplers & connectors etc., with clamps at 1.00 metre spacing. This includes testing of joints complete as per direction of the Engineer in charge. INTERNAL WORK - EXPOSED ON WALL1216 (16 mm OD) pipe |
| 166 | Providing and fixing Polyethelene-Aluminium-Polyethelene (PE-AL-PE) Composite Pressure Pipes conforming to IS - 15450, U.V. stabilized with carbon black having thermal stability for hot & cold water supply, capable to withstand temperature up to 80°C, including all special fittings of composite material (engineering plastic blend and brass inserts wherever required) e.g. elbows, tees, reducers, couplers & connectors etc., with clamps at 1.00 metre spacing. This includes testing of joints complete as per direction of the Engineer in charge. INTERNAL WORK - EXPOSED ON WALL1620 (20 mm OD) pipe |
| 167 | Providing and fixing Polyethelene-Aluminium-Polyethelene (PE-AL-PE) Composite Pressure Pipes conforming to IS - 15450, U.V. stabilized with carbon black having thermal stability for hot & cold water supply, capable to withstand temperature up to 80°C, including all special fittings of composite material (engineering plastic blend and brass inserts wherever required) e.g. elbows, tees, reducers, couplers & connectors etc., with clamps at 1.00 metre spacing. This includes testing of joints complete as per direction of the Engineer in charge. INTERNAL WORK - EXPOSED ON WALL2025 (25 mm OD) pipe |
| 168 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. INTERNAL WORK - EXPOSED ON WALL15 mm nominal outer dia Pipes |
| 169 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. INTERNAL WORK - EXPOSED ON WALL20 mm nominal outer dia Pipes |
| 170 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. INTERNAL WORK - EXPOSED ON WALL25 mm nominal outer dia Pipes |
| 171 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. EXTERNAL WORK40 mm nominal outer dia Pipes |
| 172 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. EXTERNAL WORK50 mm nominal outer dia Pipes |
| 173 | Providing and fixing Stainless Steel A ISi 304 (18/8) kitchen sink as per IS: 13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittingsand brackets, cutting and making good the walls wherever required :Kitchen sink without drain board:610x460 mm bowl depth 200 mm |
| 174 | Dismantling 15 to 40 mm dia G.I. pipe including stacking of dismantled pipes within 50 metres lead as per direction of Engineer- in-Charge. (a) Internal Work -Exposed on wall |
| 175 | Disconnecting damaged overhead/terrace PVC water storage tank of any size from water supply line and removing from the terrace including shifting at groundlevel as per direction of Engineer-in- charge. |
| 176 | Providing and fixing 8 mm dia C.P. / S.S. Jet with flexible tube upto 1 metre long with S.S. triangular plate to Eureopean type W.C. of quality and make as approved by Engineer - in - charge. |
| 177 | Supply of G.I Sockets 15mm dia |
| 178 | Supply of G.I Sockets 20mm dia |
| 179 | Supply of G.I Sockets 25mm dia |
| 180 | Supply of G.I Elbow-15mm dia |
| 181 | Supply of G.I Elbow-20mm dia |
| 182 | Supply of G.I Elbow-25mm dia |
| 183 | Supply of G.I.Tees-15mm dia |
| 184 | Supply of G.I.Tees-20mm dia |
| 185 | Supply of G.I.Tees-25mm dia |
| 186 | Supply of G.I.Nipples-15mm dia |
| 187 | Supply of G.I.Nipples-20mm dia |
| 188 | Supply of G.I.Nipples-25mm dia |
| 189 | Labour rate for small petty water supply repair work such as fixing as washer in bib cock, stop cock, pillar cock adjusting as floot valve as cistern, fixing as water supply fittings suck as G.Innipple, sockets, tee lug, union, elbow etc.and when required as per instruction etc. |
| 190 | Laying as G.I.Pipe encluding required fittings as per instruction of EIC15mm dia nominal bore |
| 191 | Laying as G.I.Pipe encluding required fittings as per instruction of EIC 20mm dia nominal bore |
| 192 | Laying as G.I.Pipe encluding required fittings as per instruction of EIC 25mm dia nominal bore |
| 193 | Laying as G.I.Pipe encluding required fittings as per instruction of EIC 40mm dia nominal bore |
| 194 | Laying as G.I.Pipe encluding required fittings as per instruction of EIC50mm dia nominal bore |
| 195 | Laying as G.I.Pipe encluding required fittings as per instruction of EIC80mm dia nominal bore |
| 196 | Labour charge or fixing/repairing of C.I sluice valve-50mm |
| 197 | Labour charge or fixing/repairing of C.I sluice valve-80mm |
| 198 | Cleaning of roof top water tank including draining out water, cleaning disinfecting the tank by bleaching powder etc and washing the tank with fresh water, writing of cleaning date with paint on the outer face of the tank all complete with tools, tackles and consumables as per instruction of EIC . 3 times in year ( 2347*3*2yr) |
| 199 | Cleaning of ground water reservoir including scrapping of stains and muck from wall & floor and removal of muck from reservoir, disinfecting the tank by bleaching powder lime etc and washing the tank with fresh water, writing of cleaning date with paint on the outer face of the tank all complete with tools, tackles and consumables as per instruction of EIC. (1908.08*2*2yr) once in a year |
| 200 | Operation of sluice valve, pumps and supply of water in colony area. Complete job as per instruction of Engineer Incharge. (2 Nos. Operator skilled manpower+ 10 Nos. Valve man required semi skilled manpower per day ) |
| 201 | Remaking and fixing of braced and battened shutter for door and window without planks etc. all complete |
| 202 | Cleaning of surface drain including disposal of muck/ sludge through trolley or other arrangements to a specified place ( in no case it shall be kept on drain banks) within a lead of 1 KM complete with all tools and tackles as per instruction of EIC( During rainy season -weekly, other months-fortnight)Upto 300mm wide |
| 203 | Cleaning of surface drain including disposal of muck/ sludge through trolley or other arrangements to a specified place ( in no case it shall be kept on drain banks) within a lead of 1 KM complete with all tools and tackles as per instruction of EIC( During rainy season -weekly, other months-fortnight)Above 300mm and upto 600mm wide |
| 204 | Cleaning of surface drain including disposal of muck/ sludge through trolley or other arrangements to a specified place ( in no case it shall be kept on drain banks) within a lead of 1 KM complete with all tools and tackles as per instruction of EIC( During rainy season -weekly, other months-fortnight) Above 600mm wide |
| 205 | Collection of garbage from door to door and disposal of the same through trolley or other suitable arrangements to the specified place within a lead of 1 KM including sweeping of stair case ( for 1st & 2nd floor qtrs) with all tools and tackles complete, as per instruction of EIC ( Daily):Ground Floor |
| 206 | Collection of garbage from door to door and disposal of the same through trolley or other suitable arrangements to the specified place within a lead of 1 KM including sweeping of stair case ( for 1st & 2nd floor qtrs) with all tools and tackles complete, as per instruction of EIC ( Daily) 1st Floor |
| 207 | Collection of garbage from door to door and disposal of the same through trolley or other suitable arrangements to the specified place within a lead of 1 KM including sweeping of stair case ( for 1st & 2nd floor qtrs) with all tools and tackles complete, as per instruction of EIC ( Daily) 2nd Floor |
| 208 | Brooming & cleaning of all roads in colony and within the premises of service buildings and other places as required with all tools and tackles and stacking the garbage at specified place as per instruction of EIC( Mian Road-Daily,Branch road-weekly) |
| 209 | Cleaning of all types of roof including removal of dry leaves, weedings and clearing drain holes, brooming etc, all complete with tools and tackles and stacking the garbage at specified place as per instruction of EIC.( once in 4 month) |
| 210 | Disposal of dead animals including transportation to the specified place, making earth pit, disposal of dead animals into pit with adequate of salt, lime and bleeching powder etc. and refilling the pit with earth all complete with tools, tackles and consumables as per instruction of EIC.Big animals (Cow, buffalo, Ox and the like) |
| 211 | Disposal of dead animals including transportation to the specified place, making earth pit, disposal of dead animals into pit with adequate of salt, lime and bleeching powder etc. and refilling the pit with earth all complete with tools, tackles and consumables as per instruction of EIC.Small animals ( Dog, cat, fox, pig and the like) |
| 212 | Cleaning of toilet attached with hostel rooms, office chambers etc. including cleaninf of floors, skirting and dado WC pan(Indian / European type) , wash basins , shelves, mirrors and other fitting , if any by hand dusting and cleaning with soap solution , acids, deodrants, phenyl etc. to make the toilet clean and hygeinic and providing naphthalene balls in urinals complete with all tools , tackles and consumables as per instruction of EIC.( Three times in a day) |
| 213 | Cleaning of sludge line and traps ( kitchen & toilet) of all diameters at different floors including opening of joint, cleaning of pipe line and again jointing and flushing with fresh water all complete with tools and tackles as per instruction of EIC |
| 214 | Cleaning of general/ common toilet including cleaning of WC pan (Indian/ European) , wash basins, urinals by hand dusting and cleaning with soap solution , acids, deodrants, phenyl etc. to make the toilet clean & hygeinic including providing naphthalene balls in urinals etc. complete with all tools & tackles and consumables as per instruction of EIC( 2 times in day) |
| 215 | Cleaning, mooping and washing of floor of public buildings other places neatly with detergent/ bleaching powder etc all complete with tools & tackles and consumables to make the floor clean & hygeinic as per instruction EIC |
| 216 | Cleaning of toilet ( floor area upto 10 sqm ) including cleaning of dado, skirting WC pan ( Indian & european), wash basins , urinals, glass shelves, mirrors, and other fittings, if any for D type or equivalent quarters including any other wash basins outside the toilet by hand dusting and cleaning with soap solution , acids, deodrants, phenyl, etc. to make the toilet clean and hygeinic all complete with tools , tackles, consumables as per instruction of EIC( weekly cleaning for all types of toilets) |
| 217 | Cleaning of toilet (floor area upto 8 SqM) including cleaning of dado, skirting, WC pan (Indian type/ western type), wash basin, urinals, glass shelves, mirror and other fittings, if any for \\"C\\" type or equivalent qtrs. Including any other wash basin outside the toilet by hand dusting and cleaning with soap solution acids, deodrants, phenyl etc. to make the toilet clean & hygeinic all complete with tools, tackles & consumables as per instruction of EIC.( weekly cleaning for all types of toilets) |
| 218 | Cleaning of toilet including WC pan, wah basin, other fittings, if any for \\"B\\" & lower type qtrs by hand dusting and cleaning with soap solution acids & phenyl etc. to make the toilet clean & hygeinic all complete with tools, tackles as per instruction of EIC.( weekly cleaning for all types of toilets) |
| 219 | Regular maintenance of lawn, hedges, flower beds & ornamental plants including cutting of grass with lawn movers, panelling with lawn roller, removal of unwanted weeds, watering, spraying of insecticides/ fungicides and spreading of fertilizers etc with tools & plants of all complete as per instruction of EIC, (cost of earth, manure, insecticides, fungicides, fertilizers shall be paid separately, if so need. Maintenance of lawn |
| 220 | Regular maintenance of lawn, hedges, flower beds & ornamental plants including cutting of grass with lawn movers, panelling with lawn roller, removal of unwanted weeds, watering, spraying of insecticides/ fungicides and spreading of fertilizers etc with tools & plants of all complete as per instruction of EIC, (cost of earth, manure, insecticides, fungicides, fertilizers shall be paid separately, if so need. Maintenance of flower bed |
| 221 | Regular maintenance of lawn, hedges, flower beds & ornamental plants including cutting of grass with lawn movers, panelling with lawn roller, removal of unwanted weeds, watering, spraying of insecticides/ fungicides and spreading of fertilizers etc with tools & plants of all complete as per instruction of EIC, (cost of earth, manure, insecticides, fungicides, fertilizers shall be paid separately, if so need. Maintenance of Hedges |
| 222 | Maintenance of ornamental plants, other show plants planted in pots and on ground |
| 223 | Supply of good quality of pots Earth pot 13\\" size |
| 224 | Mosaic pot 15\\" size |
| 225 | Supply of different plants Dehelia (HIB) |
| 226 | Supply of different plants Guldawadi (HIB) |
| 227 | Supply of different plants Marigold (HIB) |
| 228 | Supply of different plants Pansy (HIB) |
| 229 | Supply of different plants Salviya (HIB) |
| 230 | Supply of different plantsArocarriya (10\\" to 12\\") |
| 231 | Supply of different plants Cycus (2 years) |
| 232 | Supply of different plantsRose |
| 233 | Supply of different plantsCaroten ( Duck foot) |
| 234 | Supply of different plants Pichuria palm ( Two years) |
| 235 | Supply of different plants Pansutia |
| 236 | Supplying of variety of seeds of seasonal flower & vegitables Supply of good quality seeds of flowers ordinary |
| 237 | Supply of good quality seeds of flowers hybrid |
| 238 | Painting of flower pots each pot - 12\\" |
| 239 | Planting of different plants On ground |
| 240 | Planting of different plantsIn pots |
| 241 | Supply of Inseticides : DAP |
| 242 | Supply of Inseticides :Bone meal |
| 243 | Supply of Inseticides :Urea |
| 244 | Supply of Inseticides :NPK |
| 245 | Supply of Inseticides :Rose mixture |
| 246 | Supply of Inseticides :Neem cake |
| 247 | Supply of Inseticides :Melathian |
| 248 | Supply of Inseticides :Rogar 30% |
| 249 | Supply of Inseticides :Indocell |
| 250 | Supplying and stacking of good earth at site including royalty and carriage upto 5 km complete (earth measured in stacks will be reduced by 20% for payment). |
| 251 | Renovating lawns including weeding, cheeling the grass, forking the ground, top dressing with sludge or manure, mixing the same with forked soil, watering and maintaining the lawn for 30 days or more till the grass forms a thick lawn free from weeds and fit for mowing and disposal of rubbish as directed, including supplying good earth if needed but excluding the cost of sludge or manure (the good earth shall be paid for separately). |
| 252 | Supplying and stacking sludge at site including royalty and carriage upto 5 km complete (sludge measured in stacks will be reduced by 8% for payment). |
| 253 | Anti Adult Measures :- General disinfection/ Pest control with new generation odurless, colourless insecticides which should be safe for human being and effective for all kind of house hold insects like mosquitoes, house flies, etc. using residual spray of Deltametherine 2.5% SC flow (K-Othrine or approved equivalent). Insecticides should be sprayed uniformly over the surfaces of walls, ceiling etc. Frequency once in Three months. |
| 254 | Anti Adult Measures :- General disinfection/ Pest control with new generation odurless, colourless insecticides which should be safe for human being and effective for all kind of house hold insects like mosquitoes, house flies, etc. using residual spray of Cyfluthrin 5% EW (Solfac EW 050 or approved equivalent). Insecticides should be sprayed uniformly over the surfaces of walls, ceiling etc. Frequency once in Three months. |
| 255 | Thermal fogging- Using insecticides Deltamethrin 1.25% ULV (Kingfog or approved equivalent) mixed with diesel in the ratio of 1:199, for outdoor operation of colony etc. (Frequency Monthly) |
| 256 | Anti Larva measures : Treatment by using Diflubenzuron 25% WP (Bi-Larv or approved equivalent) solution to be spread as per instruction of EIC. Frequency Weekly. |
| 257 | Supplying chemical emulsion in sealed containers including deliveryas specified.Chlorpyriphos/ Lindane emulsifiable concentrate of 20% |
| 258 | Diluting and injecting chemical emulsion for POST- CONSTRUCTIONAL anti-termite treatment (excluding the cost of chemical emulsion) :Treatment at points of contact of wood work by chemical emulsion Chlorpyriphos/ Lindane (in oil or kerosene based solution) @ 0.5 litres per hole by drilling 6 mm dia holes at downward angle of 45 degree at 150 mm centre to centre and sealing the same. |
| 259 | Diluting and injecting chemical emulsion for POST- CONSTRUCTIONAL anti-termite treatment (excluding the cost of chemical emulsion) :Treatment of existing masonry using chemical emulsion @ one litre per hole at 300 mm interval including drilling holes at 45 degree and plugging them with cement mortar 1:2 (1 cement : 2 coarse sand) to the full depth of the hole :With Chlorpyriphos/Lindane E.C. 20% with 1% concentration |
| 260 | Diluting and injecting chemical emulsion for POST- CONSTRUCTIONAL anti-termite treatment (excluding the cost ofchemical emulsion) :Along the external wall below concrete or masonry apron using chemical emulsion @ 2.25 litres per linear metre including drillingand plugging holes etc.:With Chlorpyriphos/ Lindane E.C. 20% with 1% concentration |
| 261 | Providing fascility manager( 1no per day for90days) (1 nos. Skilled manpower) |
| 262 | Providing Asst fascility manager(3 civil ) per day for 90 days (3 Nos. Semi skilled manpower) |
| 263 | Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required.1 x 1.5 sq. mm |
| 264 | Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required.2 x 1.5 sq. mm |
| 265 | Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required.2 x 2.5 sq. mm |
| 266 | Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required.2 x 4 sq. mm |
| 267 | Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required.2 x 6 sq. mm |
| 268 | Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.25mm |
| 269 | Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.32mm |
| 270 | Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.40mm |
| 271 | Supplying and fixing metal box of following sizes (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including painting etc. as required.100 mm X 100 mm X 60 mm deep |
| 272 | Supplying and fixing metal box of following sizes (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including painting etc. as required.180 mm X 100 mm X 60 mm deep |
| 273 | Supplying and fixing metal box of following sizes (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including painting etc. as required.200 mm X 150 mm X 75 mm deep |
| 274 | Supplying and fixing metal box of following sizes (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including painting etc. as required.200 mm X 250 mm X 75 mm deep |
| 275 | Supplying and fixing following piano type switch/ socket on the existing switch box/ cover including connections etc. as required.5/6 amps switch |
| 276 | Supplying and fixing following piano type switch/ socket on the existing switch box/ cover including connections etc. as required.2 way 5/6 A switch |
| 277 | Supplying and fixing following piano type switch/ socket on the existing switch box/ cover including connections etc. as required.15/16 A switch |
| 278 | Supplying and fixing following piano type switch/ socket on the existing switch box/ cover including connections etc. as required.3 pin 5/6 A socket outlet |
| 279 | Supplying and fixing following piano type switch/ socket on the existing switch box/ cover including connections etc. as required.6 pin 15/16 A socket outlet |
| 280 | Supplying and fixing following piano type switch/ socket on the existing switch box/ cover including connections etc. as required.Bell push |
| 281 | Installation, testing and commissioning of pre-wired, fluorescent fitting / compact fluorescent fitting of all types, complete with all accessories and tube/lamp etc. directly on ceiling/ wall, including connections with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required. |
| 282 | Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable etc. as required. |
| 283 | Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required.Upto 400mm sweep |
| 284 | Supplying & fixing suitable size GI box wih modular plate and cover in front on surface or in recess including providing and fixing 25 A modular socket outlet and 25 A modular SP MCB, \\"C\\" curve including connections, painting etc. as required |
| 285 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole |
| 286 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Double pole |
| 287 | Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required. |
| 288 | Supplying and fixing following rating, double pole, 240 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 A |
| 289 | Supplying and fixing following rating, double pole, (single phase and neutral), 240 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 A |
| 290 | Supplying and fixing following rating, four pole, 415 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.100 A |
| 291 | Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)8 way , Double door |
| 292 | Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)12 way , Double door |
| 293 | Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required. |
| 294 | Supplying and fixing PVC batten/ angle holder including connections etc. as required. |
| 295 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required5/6 A switch |
| 296 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required2 way 5/6 A switch |
| 297 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required15/16 A switch |
| 298 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required3 pin 5/6 A socket outlet |
| 299 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required6 pin 15/16 A socket outlet |
| 300 | Providing and fixing 100 A, 4 Pole, 30 KA rating and breaking capacity MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required. |
| 301 | Providing and fixing following capacity TP&N disconnector fuse switch unit inside the existing panel board with ISI marked HRC fuses including drilling holes in cubicle panel, making connections, etc. as required.100 A TP&N |
| 302 | Providing and fixing following capacity TP&N disconnector fuse switch unit inside the existing panel board with ISI marked HRC fuses including drilling holes in cubicle panel, making connections, etc. as required.200 A TP&N |
| 303 | Supplying and fixing of 63 A, 30 mA rating, double pole, (single phase and neutral), 240 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 milli amperes in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 304 | Supplying and fixing 3 pin, 5 A ceiling rose on the existing junction box/ wooden block including connections etc. as required |
| 305 | Sheet steel DP MCB enclosure |
| 306 | Supplying and making outdoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core, XLPE aluminium conductor cable of 11 KV grade as required: 70Sq.mm. |
| 307 | Supplying and making straight through cable jointing with heat shrinkable jointing kit complete with all accessories including ferrules suitable for following size of 3 core, XLPE cable of 11 KV grade as required. 70 Sqmm |
| 308 | 25 mm X 5 mm G.I. strip (1.0 kg/mtr) |
| 309 | G.I. nuts and through bolts with washer |
| 310 | Shackle insulator ( 75 mm X 90 mm ) with G.I. bolts and nuts |
| 311 | Pin insulator ( 100 mm X 65 mm ) with G.I. spindle and nuts |
| 312 | G.I. pipes 25mm dia |
| 313 | G.I. pipes 32mm dia |
| 314 | Supply, installation, testing and commissioning of recess mounting 15W LED slim, compact, aluminium die cast edge lit panel, square fixture with opal diffuser and with separate electronic driver, complete with all accessories etc. directly in ceiling, including connection with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required. |
| 315 | Supply, installation, testing and commissioning of high brightness IP65 LED strips with uniformity of light required for perfect outdoor application , complete with all accessories etc. directly in ceiling, including connection with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required. |
| 316 | Supply, installation, testing and commissioning of trim slim LED panel 3W LED slim down light with glare free opal diffuser fitting of all types, complete with all accessories etc. directly on ceiling, including connection with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required. |
| 317 | Supply, installaion, testing and commissioning of 12W under water fountain light (made from stainless steel 316), IP64 rated, with 3Meter power cable and built in driver of suitbale color RGM/white/warm-white as in instruction of EIC |
| 318 | Supplying and fixing of light class G.I. pipe of 100 mm dia. (nominal) 3 metres length along the pole for protection of under ground cable as required. |
| 319 | Providing and fitting of remote battery(For AC/BLDC fan,etc) |
| 320 | Supply and installation of stepped type electronic fan regulator ISI Marked on the existing switch boox/ cover plate including connections etc. as required |
| 321 | Providing and fixing of service line connection with 10 sqmm, 4 Core Aluminium unarmoured cable. |
| 322 | Supply and fixing of Copper Busbar Chamber of 200 A Rating, wall mounted, 8 Way on location specified by EIC as per requirement. |
| 323 | Supply and installation of 2 core, 6 sqmm PVC insulated cable of make-Havells/Equivalent with FR PVC, round sheathed, copper conductor (flexible) industrial cable, 1100 Volts, conforming to IS694 |
| 324 | Supply and Fixing of Ding Dong wireless and polyphonic call bell with batteries. |
| 325 | Supply and fixing of Square shape, 24 Watt, 284 MM X 284 MM X 23 MM LED recessed mounted Ceiling Light \\"Octane LED Panel Square\\" of make Havells of 6500 K Color Temperature, Warranty minimum 2 years, Polycarbonate Material or equivalent make having same specifications as specified including cutting of board, connections in pre-existing electircal wire circuit, finishing to look good and including contractor Profit. |
| 326 | Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth up to 30 cm measured at a height of 1 m above ground level and removal of rubbish up to a distance of 50 m outside the periphery of the area cleared. (The work will include Survey pegging/ jungle cleaning including tree branch cutting and removing it out side away from O/H line for taking alignment at O/H line in LT Line supplying power to different Kakri Township, Tree Trimming HT line supplying power from kakri mine to kakri township) |
| 327 | Dismantling and installation of Ceiling Fan. |
| 328 | Rewinding of Ceiling fan with super enameled copper wire of suitable gauge after clearing of damaged / burnt winding including greasing checking etc. compete in all respect. |
| 329 | Supply and fixing of Main shaft of Ceiling Fan. |
| 330 | Supply and fixing of copper bush of different size suitable to existing / rewound ceiling fan of different size and make. |
| 331 | Supply and fixing of rubber bush, nut bolt, chira pin with clamp of different size suitable to existing / rewound ceiling fan of /different size and make. |
| 332 | Supply and fixing of sealed ball bearing like 6201, 6202, 6203, 6204 of reputed, makes- SKF, FAG, NBC, Timken only suitable to existing / rewound ceiling fan of different size. |
| 333 | Supply and fixing of Connector of different size suitable to existing / rewound ceiling fan of /different size and make. |
| 334 | Supply and fixing of Down Rod of different size suitable to existing / rewound ceiling fan of /different size and make. |
| 335 | Supply and fixing of capacitor 2.5/3.15 mfd 440 Volt as per ISI Specification. |
| 336 | Servicing of ceiling fan |
| 337 | Repair, Rewinding and Maintenance of 300 mm Sweep Size Exhaust Fan as per nature of complaintCopper Wire 320 gm each for rewinding |
| 338 | Repair, Rewinding and Maintenance of 300 mm Sweep Size Exhaust Fan as per nature of complaintBearing set |
| 339 | Repair, Rewinding and Maintenance of 300 mm Sweep Size Exhaust Fan as per nature of complaintBlade |
| 340 | Repair, Rewinding and Maintenance of 300 mm Sweep Size Exhaust Fan as per nature of complaintCondenser 2.5/3.15 Mfd |
| 341 | Repair, Rewinding and Maintenance of 300 mm Sweep Size Exhaust Fan as per nature of complaintShaft and Bush |
| 342 | Repair, Rewinding and Maintenance of 300 mm Sweep Size Exhaust Fan as per nature of complaintLabour Charges |
| 343 | Repair, Rewinding and Maintenance of 300 mm Sweep Size Exhaust Fan as per nature of complaintContractor Profit |
| 344 | Normal servicing of AC and removal of dust with dust blower and jet water spray. |
| 345 | Complete servicing of AC and removal of dust of indoor and outdoor unit with jet water spray. |
| 346 | Checking of leakage and Gas Charging |
| 347 | Supply of Gas R-32 or other as per instructions of EIC. |
| 348 | Supply of Gas R-22 or other as per instructions of EIC. |
| 349 | Repairing of PCB |
| 350 | Supply and Fixing of Running Capacitor 50/55 mf |
| 351 | Supply and Fixing of Copper Pipe 1/4\\" |
| 352 | Supply and Fixing of Copper Pipe 1/2\\" |
| 353 | Supply and Fixing of Contactor Relay |
| 354 | Supply and Fixing of Sensor |
| 355 | Supply and Fixing of New PCB |
| 356 | Supply and Fixing of AC filter net |
| 357 | Supply and Fixing of Indoor motor |
| 358 | Supply and Fixing of Indoor blower |
| 359 | Supply and Fixing of Outdoor Fan |
| 360 | Supply and Fixing of Outdoor Motor |
| 361 | Supply and Fixing of Compressor of 1.5 T AC |
| 362 | Supply and Fixing of Condenser Coil |
| 363 | Supply and Fixing of ODU Motor |
| 364 | Supply and Fixing of AC Outdoor Unit Stand |
| 365 | Supply and Fixing of Drain Pipe |
| 366 | Supply and fixing of selector switch |
| 367 | Supply and fixing of capillary pipe |
| 368 | Supply and fixing of fan blade |
| 369 | Installation, Dismantling and vice versa of window/split AC of 1.5 T, 2 T etc. As per instructions of EIC. |
| 370 | Supply and Fixing of Water Cooler Compressor |
| 371 | Supply and Fixing of Water Cooler Tank Coil |
| 372 | Water Cooler Gas Charging |
| 373 | Water Cooler Service Charge |
| 374 | Supply and Fixing of EVAP Fan Motor |
| 375 | Rewinding of fan motor |
| 376 | Supply and Fixing of Defrost PCB |
| 377 | Supply and Fixing of Relay OLP |
| 378 | Supply and Fixing of float valve |
| 379 | Supply and Fixing of capacitor |
| 380 | Supply and Fixing of cooling and condensing unit |
| 381 | Supply and Fixing of Sensor |
| 382 | Complete Servicing, washing, greasing, oiling and painting of bootom surface of water cooler with Labour Charges |
| 383 | Servicing including repair & maintenance, greasing, Repair of body, water tank, dismantling pillars, bends, switch, wiring, fasteners and it’s testing commissioning and installation. |
| 384 | Replacement of its wire net |
| 385 | Replacement of special type Grass |
| 386 | Rewinding of cooler fans |
| 387 | Rewinding of exhaust fans |
| 388 | Replacement of bearing (6201,6202 & 6203 ) |
| 389 | Replacement of condenser 4 µF |
| 390 | Replacement of pumps |
| 391 | Replacement of front grills |
| 392 | Replacement of PVC wire 3x2.5 sq. mm |
| 393 | Replacement of PVC PIPE 1/2” diameter |
| 394 | Replacement of metal bush |
| 395 | Replacement of shaft |
| 396 | Replacement of cooler body 20 SWG |
| 397 | Replacement of tank |
| 398 | Painting of coolers body and its accessories two coat complete in all respect |
| 399 | Erection of steel tubular pole ,rail pole exceeding 11 m but not exceeding 16 m in brick blast/ local hard stone withcement & local sand including excavation of the pit size 0.8x0.8x1.6 m |
| 400 | Stringing & tensioning of AAAC conductor 80/148sq mm |
| 401 | Opening the jumper & rejumpering |
| 402 | Erection of stay set complete including winding, tensioning, with 7/16 SWG stay wire & stay insulator with back clamp on pole(stay set and insulator to be provided by contractor) |
| 403 | Erection of Steel material such as : MS channel bracket, Angle ,clamp, support, plate, pipe nut & bolt etc. |
| 404 | Providing Laying, stringing & tensioning 7/10 SWG Gl earth wire |
| 405 | Providing & fixing of pin insulator with pin 1.1kV complete Set |
| 406 | Providing & fixing of shackle insulator 1.1 kv grade with hardware complete set |
| 407 | Installation of street lights, flood lights fittings on pole/towers |
| 408 | Dismantling of street lights, flood lights fittings on pole/towers |
| 409 | Dismantling & staking of 11m tubular pole |
| 410 | Dismantling & staking of stay set with stay wire, stay, clamp & stay insulator |
| 411 | Dismantling and stacking of Steel material such as : MS channel bracket, angle, clamp, support, plate, pipe nut & bolt etc. |
| 412 | Dismantling of AAAC conductor |
| 413 | Dismantling and stacking of earth wire size 7/14 or 7/16 SWG |
| 414 | Fabrication of steel material such as: MS channel bracket, Angle, clamp, support plate etc.( steel material, gas departmentally provided and other material such as welding machine, welding rod, cutting set are provided by contractor) |
| 415 | Hanging and fixing of double armoured cable on the pole |
| 416 | Collection of pole and its transporting |
| 417 | Providing and fitting Surge arrester 650V |
| 418 | Providing and fitting Surge arrester 7.2KV |
| 419 | Providing & fixing of Gl nut & bolt size 5/8\\" X4\\", ¾\\"X3\\",3/4\\" X2.5\\", & 5/8\\"X10\\" full thread |
| 420 | Rectification of No Power complaints.Maintenance of power supply & distribution system in the township including maintenance of LT OH/L, G.O. Switch, Power transformer, MCCBs feeder piller, bus bars, cables, service lines, main switches & street lights etc as required on day to day basis. (3 Skilled , 3 semi-skilled , 2un-skilled Labours) |
| 421 | One no. Facility Manager for Electrical work |
| 422 | Total impact of GST for the purpose of CTC Please Enable Macros to View BoQ information |
| SR No | FileName | File Description |