| 1 | Dismantling wall / ceiling boards of any description, fixed in any position with nails or screws, complete all as specified and directed by Engineer-in-Charge. |
| 2 | S&F Anodised aluminium snap grid frame work (Size of grid 605 x 605mm) for false ceiling all as specified |
| 3 | M & L poviding and fixing Gypsum bd 8mm thk in ceiling laid over anodised aluminium snap grid framework complete all as specified and directed |
| 4 | M & L 9mm thick Veneered decorative plywood, grade 1 (with BWR resin) with decorative face veneers on one faces; fixed with screws to timber frame work complete all as specified and directed |
| 5 | Taking down chowkat with shutter wood or aluminium (Without taking of shutter from frame) area exc 1.50 Sqm but nexc 4.00 Sqm each complete all a specified and directed. |
| 6 | S&F 2nd class hard wood plain solid straight chowkats & frame wrought framed on the solid rounded or chamfered put together with glue pinned at joints complete all a specified and directed. |
| 7 | S&F 30mm thick Flush shutters solid core construction with Block board and plywood face panels commercial type both side complete all a specified and directed. |
| 8 | S&F for Anodised aluminium frame for doors, windows, ventilators with one or morerebates including joining cleat for fixing etc. complete all as specified |
| 9 | S&F for Anodised aluminium door shutters,aluminium section weighing 0.55 kg/m including necessary joining cleats, glazing clips, ruber neoprene packing, handles 2 Nos in each door, hinges, anodised aluminum snap beading screws etc. complete all as specified. |
| 10 | S&F in repairs 4mm thick sheet glass ordinary quality and glazing with oil putty in square n exc. 0.5 Sqm in each pane including hacking out of glass panes complete and all as specified and directed |
| 11 | Taking down chowkat with shutter (Without taking of shutter from frame) area exc 1 sqm n exc 2 Sqm complete all a specified and directed. |
| 12 | S&F solid PVC door frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with M.S. square tube as specified and drawing complete all a specified and directed. |
| 13 | S&F factory made solid panel PVC door shutter 30mm thick (Style) consisting of frame made out of M.S tube for top & bottom rails M.S. frame shall be covered with heat molded wood plain colour PVC 'C' channel having a PVC sheet strip of 20mm width struck inside with solvent cement for stiles and plain colour PVC sheet as for top rail lock rail & bottom rail on either side,all as directed by Engr-in charge. |
| 14 | S & F factory made uPVC white colour casement (Openable) window ( area exc 1.00 sqm but not exc 2.00 sqm each) made of extruded profiles with wall thickness of 2.3mm ( + – 0.2mm). Window profile with hollow section with multi chamber, frame (60mm x 58mm), sash (60mm x 73mm), T profile (One vertical length in between two shutters) (60mm x 74mm), Glazing bead (35mm x 20mm) will be mitered cut and fusion welded at all corners, including drilling of holes for fixing hardware and drainage of water etc., making arrangement for fixing of hardware. EPDM gasket 1.2 +– 0.2mm thick, galvanized steel Frame (28mm x 21.5mm), sash (31mm x 27.5mm). T profile (27mm x 17mm) to be inserted in required profile, frame will be fixed to the wall with 8 mm x 100mm long fasteners. Hardware: [casement handle made of zinc alloyed (white powder coated), But Hinges of'zinc alloyed (white powder coated), transmission gear made of mild steel with multi point locking system] and 5mm thick glazing with selected quality glass incl. |
| 15 | M&L for two coat of synthetic enamel paint over one coat of pink primer to newly untreated wooden surface over 10cm width or girth incl preparation of surface all as directed |
| 16 | S&F 150 mm long aluminium tower bolt, complete and all as specified. |
| 17 | S&F 300 mm long Aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy all as specified |
| 18 | S&F MS 100 mm size butt hinges medium wt. of cold rolled complete and all as specified. |
| 19 | S&F aluminium handles, cast type anodised 100mm size complete all as specified |
| 20 | Dismantling floor hearth or wall tiling including cement mortar bedding but not backing, removing serviceable tiles to store and rubbish off the premises. |
| 21 | M & L 75 mm thick Cement concrete type C2, 1:3:6 (using 40 mm graded granite stone aggregate) in plinth protection finishing the surface even and smooth |
| 22 | M&L for 25mm thick Cement concrete 1:2:4 type B-0 using 12.5 mm graded stone aggregate in leveling course, benching etc, finished even & rough to receive cement mortar screed bed complete |
| 23 | M & L light shade Virified Ceramic tiles 10 mm thick (square/ rectangular) polished, area of each tiles not exceeding 0.36 sqm, in floors incl 15mm thick screed bed in CM 1:6 etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and directed |
| 24 | M&L for Non skid ceramic joint free coloured tiles 400 x 400 x 7 to 8 mm thick, in floors etc, set and jointed in neat cement slurry and pointed in coloured cement to match tiles over and including 10 mm thick screed bed or bedding layer in CM (1:6) complete. |
| 25 | Glazed ceramic tiles in vertical surface colour tiles 350x 250x 7 mm/ 450X 350X 7mm thick set and jointed in neat cement slurry and pointed in white or colour cement tomatch and including 10 mm thick screed bed or rendering layer in CM (1:4) complete all as specified. |
| 26 | Taking down cement plaster or brick or stone walls etc, including raking out joints, hacking for key, scrubbing down with water all as specified and directed |
| 27 | M&L 15mm thick rendering over other than fair faces of brick work or concrete sufaces in CM 1:4 including finishing even and smooth without using extra cement all as specified and directed |
| 28 | M&L preparation of plastered or uplastered new surfaces on walls and applying two coats cement base paint on walls over a coat of primer all as specified and directed |
| 29 | M&L for 15 mm thick rendering in CM 1:6 on brick work or concrete surfaces finished even and smooth without using extra cement, complete all as specified and directed by Engineer-in-Charge. |
| 30 | M&L preparation of new surfaces on walls and applying two coats of oil bond distemper on walls over one coat of chaulk whitning complete all as specified and directed |
| 31 | Taking up or down steel tubing 15mm and connections, including cleaning for refixing or removal to store |
| 32 | Taking up or down steel tubing 20mm and connections, including cleaning for refixing or removal to store |
| 33 | M&L 16mm outer dia for 3-layer PP-R Polypropylene random copolymer) concealed pipes SDR 7.4 (PN16) UV stabilized and antimicrobial fusion welded having thermal stability for hot & cold water supply including all PP-R plain & brass threaded polypropylene random fittings fixed complete to walls, ceilings or in floors etc complete all as pecified and directed. |
| 34 | M&L 20mm outer dia for 3-layer PP-R Polypropylene random copolymer) concealed pipes SDR 7.4 (PN16) UV stabilized and antimicrobial fusion welded having thermal stability for hot & cold water supply including all PP-R plain & brass threaded polypropylene random fittings fixed complete to walls, ceilings or in floors etc complete all as pecified and directed. |
| 35 | M&L for lagging to 20mm pipes used in internal water su ply or plumbing all round with, 25min thick bonded mineral wool preformed ‘SNAP ON’ pipe sections of density 144 Kg/cum conforming to IS 9842 |
| 36 | S & F in repair 20mm Gun-metal, globe or gate valves, with iron wheelhead, screwed both ends for iron pipe and fixed complete. |
| 37 | S & F in repair 20mm Ball valves high pressure of PTMT with epoxy coated Aluminium rod & highdensity plastic ball screwed for iron pipe and fixed. (Minimum weight 15mm-142gms/ 2 0 m m - 2 1 0 g m s . / 25mm-455gms/ 40mm- 690 gms) |
| 38 | S & F PVC low level flushing cistern 10 litres capacity, white, with all fitting and fixtures including brackets and 32 mm bore PVC flush pipe , fixed in repair complete. |
| 39 | S&F Repair in PVC connections 15 mm size with PTMT nuts of length 450 mm complete all as specified and directed. |
| 40 | Dismantling plain or corrugated steel sheeting, any guage, thickness complete all as specified and directed |
| 41 | S&F Pre- painted galvalume aluminum zinc coating GI based corrugated steelsheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified complete all specified and directed. |
| 42 | S&F Pre-painted galvalume aluminum zinc coating GI based Plain steel sheet0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified complete all specified and directed. |
| 43 | M&L for preparation of old painted wooden surface and applying one coat of synthetic enamel paint of 10cm width or girth completed all as specified and directed. |
| 44 | M&L for preparation of old painted steel surface and applying one coat of synthetic enamel paint of 10cm width or girth completed all as specified and directed. |
| 45 | M&L preparation of old surfaces on walls and applying one coats of oil bond distemper complete all as specified and directed |
| 46 | M&L preparation of old surfaces on walls and applying one coats of cement base paint complete all as specified and directed |
| 47 | S & F Solid PVC wall lining consisting of 5 mm thick Plain colour PVC sheet inclusive of solvent cement and fixing at site on PVC frame as per specification and drawing. |
| 48 | S & F 5mm thick PVC sheet fillet of width 35mm for wall panaling inclusive of fixing on to wall to make PVC frame as per specification and drg. |
| 49 | Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc.removing materials to store for keeping in safe custody or for taking credit and making good disturbed surfaces of walls, floors, etc. |
| 50 | Taking down unserviceable any type of Main Switch, DB's including MCBs incl wooden/GI/MS sheet board etc and removing from site and making good the disturbed surface of wall etc all as specified and as directed. |
| 51 | Taking down unserviceable any type of copper/aluminium sub main wiring of any size/core/type complete including conduits/casing caping etc, removing the materials/debris and making good the disturbed surfaces of walls, floors and ceilings etc to match with the original existing finish all as directed. |
| 52 | Material & labour for point wiring complete with single core 1.5 Sqmm (nominal area) PVC insulated multistranded, copper conductor cable (FRLSH) drawn through and including PVC casing & caping and accessories on wall & surface/ceiling complete, terminated in and including PVC gang box fixed with nickel polished screws with washers, earth continuity PVC cable(FRLSH), copper conductor 1.5 Sqmm (nominal area) stranded with green insulation earth wire connected with earth dolly One light point / fan point / bell push point controlled by one way switch 5 Amprs and/or through regulator complete all as specified and directed. |
| 53 | Description all as per srl item No 52 above, but socket out let 3 pin, 5 Amp on same board with other switch. |
| 54 | Description all as per srl item No 52 above, but socket out let 3 pin, 5 Amp on independent board with other switch. |
| 55 | Description all as per srl item No 52 above, but using 2.5 sqmm (nominal area) PVC stranded copper conductor cable with 1.5 Sqmm PVC insulated copper cable for continuous earth continuity conductor for 3 pin socket out let 15 Amps on independent board as directed by Engineer in Charge. |
| 56 | M&L for Sub Main wiring in repairs complete with copper conductor, multi stranded, FRLS, PVC insulated and sheathed, 6 Sq mm, two run 1100 volts grade, incl drawn through PVC suitable size counduit and 6 Sqmm single run for earthing including taking down the old submain wiring all as directed by Engineer in Charge. Notes:- (i) Two wires of 6 sqmm and one wire of 6.0 sqmm and one run of PVC conduit shall be measured as one unit. |
| 57 | M&L for sub main wiring in repairs for power/circuit using PVC insulated unsheathed, stranded copper conductor cable 2 Single core of size 4 Sqmm, earth continuity conductor of size 4.0 Sqmm to be drawn through and including PVC conduit 20mm dia medium Grade concealed in walls/roof/floors including taking down the old submain wiring all as directed by Engineer in Charge.Notes:- (i) Two wires of 4 sqmm and one wire of 4.0 sqmm and one run of PVC conduit shall be measured as one unit. |
| 58 | Supply and fixing in Replacement of Sheet Metal enclosure double door for DBs when MCBs to be used SPN- 8 Way with 200Amp rated bus bar complete all as specified and directed including taking down old unserviceable DB of any description. |
| 59 | Supply and fixing in Replacement Sheet Metal enclosure double door for DBs when MCBs to be used SPN - 12 Way complete all as specified and directed including taking down old unserviceable DB of any description. |
| 60 | Supply and fixing in replacement of two pin and earth metal plug and socket complete with one single pole MCB 20 Amp, 240Volts complete all as specified and directed. |
| 61 | Supply and fix in replacement of MCB TPN 63 Amp, 240 volts,10 KA, complete all as specified and directed. |
| 62 | Supply and fix in replacement of MCB SPN 63 Amp, 240 volts,10 KA, complete all as specified and directed. |
| 63 | Supply and fix in replacement of MCB SPN 40 Amp, 240 volts,10 KA, C-curve complete all as specified and directed. |
| 64 | Supply and fix in replacement of MCB SPN 32 Amp, 240 volts,10 KA, C-curve complete all as specified and directed. |
| 65 | Supply and fix in replacement of MCB SP 6 to 32 Amp, 240 volts,10 KA, C-curve complete all as specified and directed. |
| 66 | Supply and fixing in replacement of Switch piano, flush type 5 Amps, 240 V One Way complete all as specified and directed. |
| 67 | Supply and fixing in replacement of Switch piano, flush type 15 Amps, 240 V One Way complete all as specified and directed. |
| 68 | Supply and fixing in replacement of socket out let 5 Amps 3 pin flush type for the same board complete all as specified and directed. |
| 69 | Supply and fixing in replacement of switch socket combination 5 Amps 2 in 1 flush type multipurposes for independent board complete all as specified and directed. |
| 70 | Supply and fixing in replacement of switch socket combination out let 5A/15 Amps, 5 in 1 flush type complete all as specified and directed. |
| 71 | Supply and fixing in replacement of Ceiling Rose 3 terminal size 50 x 65 mm surface type complete all as specified and directed. |
| 72 | Supply and fixing in replacement of 1X20 watt 4 ft long LED Batten housing with white diffuser and inbuilt electronic driver system lumen output should be at least 1800 lumen with a CCT of 6000 K, power factor should be greater than 0.95 with all accessories and connecting up with 3 core flexible cable white of size 23/0.0076 complete all as specified and directed. make : Bajaj or equivalent in : Havells /Philips/CG. |
| 73 | Supply and fixng in replacement Fluorescent tube light fitting, LED batten with aluminium housing provided for efficient heat dissipation wirh polycarbonate diffuser and integrated electronic driver, 1x 10 watts 2 feet light fitting with white acrylic cover along with LED lamp white colour complete and connecteing electrically to ceiling rose using PVC insulated and overall sheated flexible copper conductor of size 0.75 Sqmm 3 core fixed complete all as specified and directed. make : Bajaj or equivalent in : Havells /Philips/CG |
| 74 | S&F in replacement of LED lamp 220V, 50 Hz AC, of capacity 9 watt complete all as specified and as directed |
| 75 | Supply and fixing in replacement of lamp holder batten / angular type complete all as specified and directed suitable for 3 to 9 watt LED lamp |
| 76 | S&F incl testing of LED lamp 220V, 50 Hz AC, of capacity 3 watt complete all as specified and as directed |
| 77 | S&F incl testing of LED lamp 220V, 50 Hz AC, of capacity 5 watt complete all as specified and as directed |
| 78 | S&F incl testing of LED lamp 220V, 50 Hz AC, of capacity 7 watt complete all as specified and as directed |
| 79 | Supply and fixing in repairs square LED panel light filtting ceiling /recess mounting type with slim, compact, aluminium die cast edge lift panel completer with opal diffuser and electronic driver inbuilt of capacity 36 watt complete all as specified and directed. Make : Havells or equivalent in Bajaj/Philips. Note (i) Contractor shall provide 2 years written manufacturer's warranty for the LED fixture complete including driver from the certified date of completion. |
| 80 | Taking down ceiling fan any size or sweep after disconnecting, dismantling and removal to trade workshop for repair, complete all as specified and directed. |
| 81 | Opening the unserviceable/ burnt fan 1200/1400 mm sweep and cutting of old burnt copper winding and rewinding the same with super enamelled copper winding wire of suitable gauge including insulating material such as paper cotton sleeves, varnish, reassembling, testing and connecting for satisfactory run, complete all as specified and directed. |
| 82 | Supply and replacing of Ball bearing of the ceiling fan (any sweep) as per existing size incl greasing/oiling, complete all as specified and directed. Make:- SKF/ NBC or Equivalent |
| 83 | Supply and replacenment gun metal bushes of surface size for ceiling fan/ceiling fan incl necessary mechanical work, complete all as specified and directed. |
| 84 | Supply and replacing of cord cable, three core 0.5 Sqmm PVC insulated copper conductor cable for connecting ceiling fan, complete all as specified and directed. |
| 85 | Supply and replacing electronic step type fan regulator 240 Volt, 50 C/S, five step, suitable for 1200/1400mm sweep ceiling fan,complete all as specified and directed. |
| 86 | Supply and Fix Capacitor of of 2.5 MFD for ceiling fan, complete all as specified and directed. |
| 87 | Supply and Fix Capacitor of 4 Mfd for exhaust fan, complete all as specified and directed. |
| 88 | Supply for replacement ceiling fan blade set of three heavy duty suitable for 1200/1400mm sweep of suitable approved make as direcetd by Engr-in-Charge. |
| 89 | Supply and Fix PVC canopy for ceiling fan 1200/1400mm sweep complete for various makes/model of fan, complete all as specified and directed. |
| 90 | Disconnecting and taking down exhaust fan and blades any size or sweep after dismantling and removal to trade workshop for repair, complete all as specified and directed. |
| 91 | M&L for Strip opening and cutting of old burnt copper winding of exhaust fan and rewinding of exhaust fan motor of sweep 450mm with super enamelled copper winding wire of suitable gauge including insulating material such as paper cotton sleeves, varnish, re-assembling, testing and connecting for satisfactory run, complete all as specified and directed. |
| 92 | Description all as per srl item No 91 above, but of 300mm sweep. |
| 93 | Ball bearing of exhaust fan of any size/make as per the existing, complete all as specified and directed. Make: SKF / NBC or equivalent make. |
| 94 | Servicing of Geyser by disconnecting the electric and water supply connections, dismantling the geysers of any size, type & capacity and opening the top and bottom cover, thermostat, heating element, safety valve, vent pipe, separating inner & outer tank, removing glass wool insulation complete and keeping aside for re-use after de-scaling of inner tank by liquid chemical and with pressure water jet and assembling back the geyser including re-installation on wall with studs, nuts & bolts complete and testing after reconnecting electric and water connections, complete all as specified and directed. |
| 95 | Supply and fiixing Heating element for geyser of cap 1.5KW, AC 230 Volts, 50 Hz (as per sample), complete all as specified and directed. Make:- Micron/ Bajaj/ Havells |
| 96 | Supply and fixing Heating element for geyser of cap 2.0KW, AC 230 Volts, 50 Hz (as per sample), complete all as specified and directed. Make:- Micron/Bajaj/havells |
| 97 | Supply and fixing Thermostat for Geyser of capacity 25/35/50 ltr (long size) with temperature setting adjustment range from 40 to 85°C, ISI Marked, complete all as specified and directed. Make:- Philips/ Bajaj/ Venus |
| 98 | Geyser Syphon Assembly Set suitable for 25 ltr capacity geyser, fixed in replacement, complete all as specified and directed. |
| 99 | Description all as per srl item No 98 above, but for 35 Ltr capacity. |
| 100 | Description all as per srl item No 98 above, but for 50 Ltr capacity. |
| 101 | Rubber gasket for water heater storage type of any capacity fixed, in replacement and suitable as per the existing, complete all as specified and directed |
| 102 | Taking down old unserviceable plug top from geyser connection and Supply and Fixing in replacement plug top 15/16 Amps for Geyser, complete all as specified and directed. Make:- Havells/ Anchor/ Leader/ Plaza. |
| 103 | PVC sheathed three core copper conductor flexible wire of size 2.5 Sqmm for connecting geyser, complete all as specified and directed. Make:- Havells / Plaza |
| 104 | Supply and replacement of safety valve for geyser of 25/35/50 litre capacity, complete all as specified and directed |
| 105 | Supply and replacement of non return valve 15mm dia for geyser of 25/50 litre capacity, complete all as specified and directed. |
| 106 | Supply and replacement of heavy duty PVC connector 300mm long 15mm dia with PTMT nut for geyser of 25 / 50 litre capacity, complete all as specified and directed. Make- Prayag |
| 107 | Disconnecting and taking out geyser of capacity 25 litre and replacement of SS inner tank and refilling of glass wool, refixing, connecting and testing, complete all as specified and directed. |
| 108 | Description all as per srl item No 107 above, but for 35 Ltr capacity. |
| 109 | Description all as per srl item No 107 above, but for 50 Ltr capacity. |
| 110 | Taking down old unserviceable and supply & fixing stop cock brass 15mm dia not less than 420 grams, complete all as specified and directed. |
| 111 | Supply and fixing of geyser Bolt 100 mm Long with nut & washers, complete all as specified and directed |
| 112 | Supply and fixing Sensor board suitable for water geyser 25/35 Ltr Capacity of Make Venus Model - 25 RD/35RD. |
| 113 | Notes :- Amount of Credit Schedule for Schedule 'A' Part-ll shall be deducted from total quoted amount of BOQ to arrive at the contract sum. Please Enable Macros to View BoQ information |