| 1 | CIVIL WORK |
| 2 | 15.28.1Dismantling roofing including ridges, hips, velleys and gutters etc., and stacking thematerial within 50 metres lead of :G.S. Sheet |
| 3 | 15.17.2Dismantling steel work in single sections including dismembering and stackingwithin 50 metes lead in:Channels, angles, tees and flats |
| 4 | 15.7.4Demolishing brick work manually / by mechanical means including stacking ofserviceable material and disposal of unserviceable material within 50 metres lead asper direction of Engineer-in-Charge.In cement mortar |
| 5 | 15.2.2Demolishing cement concrete manually / by mechanical means including disposal ofmaterial within 50 metres lead as per direction of Engineer - in-Charge.Nominalconcrete 1:4:8 or leaner mix ( including equivalent design mix) |
| 6 | 2.33.3Felling trees of the girth (measured at a height of 1 m above ground level) includingcutting of trunks and branches, removing the roots and stacking of serviceablematerial and disposal of unserviceable material.Beyond 120 cm girth up to andincluding 240 cm girth |
| 7 | 2.28.1Surface dressing of the ground including removing vegetation and in-equalities notexceeding 15 cm deep and disposal of rubbish, lead up to 50 m and lift up to 1.5m.All kinds of soil |
| 8 | 2.8.1Earth work in excavation by mechanical means (Hydraulic excavator) /manual meansin foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan),including dressing of sides and ramming of bottoms, lift up to 1.5 m, includinggetting out the excavated soil and disposal of surplus excavated soil as directed,within a lead of 50 m.All kinds of soil |
| 9 | 4.1.4Providing and laying in position cement concrete of specified grade excluding thecost of centering and shuttering - All work up to plinth level:1:2:4 (1 Cement : 2coarse sand (zone-III) derived from natural sources : 4 gradedstone aggregate 40 mm nominal size derived from natural sources) |
| 10 | 50.6.7.1Laterate masonry with neatly dressed laterate stone of size 40x20x15cm or nearestsize in cement mortar 1:6 for foundation and basement including all cost of materials,labour charges etc. |
| 11 | 2.25Filling available excavated earth (excluding rock) in trenches, plinth, sides offoundation etc. in layers not exceeding 20 cm in depth, consolidating each depositedlayer by ramming and watering, lead up to 50 m and lift up to 1.5 m. |
| 12 | 50.6.7.2Laterate masonry with neatly dressed laterate stone of size 40x20x15cm or nearestsize in cement mortar 1:6 for super structure above plinth level up to floor two levelincluding all cost of materials, labour charges etc. |
| 13 | 9.48.2Providing and fixing M.S. Grills of required pattern in frames of windows etc. withM.S. flats, square or round bars etc. including priming coat with approved steelprimer all complete.Fixed to openings/ wooden frames with rawl plugs screws etc |
| 14 | 10.1Structural steel work in single section, fixed with or without connecting plate,including cutting, hoisting, fixing in position and applying a priming coat of approvedsteel primer all complete. |
| 15 | 13.1.112 mm cement plaster of mix:1:4 ( 1 cement : 4 fine sand) |
| 16 | 13.88Removing white or colour wash by scrapping and sand papering and preparing thesurface smooth including necessary repairs to scratches etc. complete. |
| 17 | 13.43.1 Applying one coat of water thinnable cement primer of approved brand andmanufacture on wall surface:Water thinnable cement primer |
| 18 | 13.60.1Wall painting with acrylic emulsion paint of approved brand and manufacture to givean even shade:Two or more coats on new work |
| 19 | 13.61.1Painting with synthetic enamel paint of approved brand and manufacture to give aneven shade:Two or more coats on new work |
| 20 | 51.18.12.6Providing and fixing G.I. pipes complete with G.I. fittings (Cost of fittings to be paidseparately) <br> External work - 50 mm nominal dia |
| 21 | 4.1.6Providing and laying in position cement concrete of specified grade excluding thecost of centering and shuttering - All work up to plinth level:1:3:6 (1 Cement : 3coarse sand (zone-III) derived from natural sources : 6 gradedstone aggregate 40 mm nominal size derived from natural sources) |
| 22 | 10.16.1Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trussesetc., including cutting, hoisting, fixing position and applying a priming coat ofapproved steel primer, including welding and bolted with special shaped washers etc.complete.Hot finished welded type tubes |
| 23 | OD142730/2025-2026Providing and fixing GI hard color powder coated traffod sheets 0.35 mm thick ornearest available thickness with overlaps of 150 mm at ends and GI hook or crankC.I. bolts and nuts including plain washers and bitumen washers etc complete |
| 24 | 13.53.1Painting on G.S. sheet with synthetic enamel paint of approved brand andmanufacture of required colour to given an even shade:New work (two or more coats)including coat of approved steel primer but excluding a coat of mordant solution. |
| 25 | 4.1.8Providing and laying in position cement concrete of specified grade excluding thecost of centering and shuttering - All work up to plinth level:1:4:8 (1 Cement : 4coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mmnominal size derived from natural sources) |
| 26 | OD157664/2025-2026Providing and laying Mat finished vitrified floor tiles in different sizes ( thickness tobe specified by the manufacturer) with water absorption less than .08% andconforming to IS :15622, of approved make, in all colours and shades laid on 20mmthick cement mortar 1:4( 1 cement, 4 coarse sand) including grouting the joints withwhite cement and matching pigments etc complete. Size of tile 600x600mm |
| 27 | 5.6Reinforced cement concrete work in chimneys, shafts, up to floor five level excludingthe cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 ( 1 cement :1.5 coarse sand(Zone III) derived from naturalsources: 3 graded stone aggregate 20 mm nominal size derived from naturalsources) |
| 28 | 5.9.11Centering and shuttering including strutting, etc. and removal of form for:Chimneysand shafts |
| 29 | 5.22.6Steel reinforcement for R.C.C work including straightening, cutting, bending, placingin position and binding all complete upto plinth levelThermo - Mechanically Treatedbars of grade Fe-500D or more |
| 30 | OD142993/2025-2026Providing best quality 7 lever 50mm padlock with three keys |
| 31 | 6.8Brick work 7 cm thick with common burnt clay F.P.S. (non modular ) brick of classdesignation 7.5 in cement mortar 1:3 (1 cement : 3 coarse sand ) in superstructureabove plinth level and upto floor five level. |
| 32 | 18.51.1Providing and fixing C.P. brass long body bib cock of approved quality conforming toIS standards and weighing not less than 690 gms.15 mm nominal bore |
| 33 | 50.18.8.8.2Providing and fixing PVC pipes, fittings, including fixing the pipe with clamps at1.00 m spacing. this includes jointing of pipes with one step PVC solvent cement andtesting of joints complete as per the direction of Engineer-in-Charge. Concealedwork, including cutting chases and making good the wall etc. 75 mm pipe 4 kgf/cm2 |
| 34 | 50.18.9.22.1Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes,including jointing with PVC solvent cement - 110 mm dia Elbow |
| 35 | 50.18.9.22.4Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes,including jointing with PVC solvent cement- 110 mm dia Bend |
| 36 | 50.18.9.22.5Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipesincluding jointing with PVC solvent cement 110x110x110 mm dia Tee Please Enable Macros to View BoQ information |