| 1 | Earthwork in excavation by mechanical means (Hydraulic excavator)/manual means in foundation trenches or drains ( not exceeding 1.5 m in width or 10 Sq. m on plan), including dressing of sides & remaining of bottoms , lift upto 1.5 m , including getting out the excavated soil and disposal of surplus excavated soil as directed , within a lead of 50 m |
| 2 | All kinds of soil. |
| 3 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20 cm in depth: consolidating each deposited layer by ramming and watering lead up to 50 m and lift upto 1.5 m |
| 4 | Providing and laying in position cement concrete of specified grade including curing but excluding the cost of centering and shuttering - All work up to plinth level : |
| 5 | 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) |
| 6 | 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) |
| 7 | Making plinth protection 50 mm thick of cement concrete 1: 3: 6 (1 cement: 3 coarse sand: 6 graded stone aggregate 20 mm nominal size) over 75 mm bed of dry brick ballast 40 mm nominal size well ramed and consolidated and grouted with fine sand including finishing the top smooth |
| 8 | Add for plaster drip course/ groove in plastered surface or moulding to R.C.C. projections. |
| 9 | Providing and laying damp-proof course 40mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand(Zone III) : 4 graded stone aggregate 12.5mm nominal size). |
| 10 | Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : |
| 11 | 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) : 3 graded stone aggregate 20 mm nominal size). |
| 12 | Reinforced cement concrete work in beams, suspended floors, roofs having slope upto 15°, landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases upto five level including curing but excluding the cost of centring, shuttering, finishing and reinforcement with |
| 13 | 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) : 3 graded stone aggregate 20 mm nominal size). |
| 14 | Centering and shuttering including strutting, propping etc. and removal of form for : |
| 15 | Foundations, footings, walls, bases of columns, etc. for mass concrete. |
| 16 | Shelves (Cast in situ) |
| 17 | Edges of slabs and breaks in floors and walls. |
| 18 | Under 20 cm wide |
| 19 | Columns, Pillars, Piers, Abutments, Posts and Struts. |
| 20 | Suspended floors, roofs, landings, balconies and access platform. |
| 21 | Lintels, beams, plinth beams, girders, bressumers and cantilevers. |
| 22 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete up to plinth level. |
| 23 | Cold twisted/TMT bars |
| 24 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in : |
| 25 | Cement mortar 1: 6 (1 cement: 6 coarse sand) |
| 26 | Extra for brick work with common burnt clay bricks/cement concrete bricks in superstructure above plinth level upto floor five level |
| 27 | Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level. |
| 28 | Cement mortar 1: 4 (1 cement: 4 coarse sand) |
| 29 | Extra for half Brick masonry in superstructure above plinth level upto floor V level. |
| 30 | Steel work in built up tubular ( round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. |
| 31 | Hot finished welded type tubes. |
| 32 | Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength confirming to IS:4454 part-1 and M.S. top cover of required thickness for rolling shutters. |
| 33 | 80x0.90 mm M.S. laths with 0.90 mm thick top cover |
| 34 | Providing and fixing aluminium tower bolts ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade with necessary screws etc. complete : |
| 35 | 150x10 mm |
| 36 | Providing and fixing aluminium handles ISI marked (powder coated) with necessary screws etc. complete : |
| 37 | 300 mm |
| 38 | Providing and fixing 18mm thick gang saw cut mirror polished premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills , facias and similar locations of required size, approved shade, colour and texture laid over 20mm thick base cement mortar 1:4 (1 cement : 4 coarse sand) joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels. |
| 39 | Granite of any colour and shade |
| 40 | Area of slab over 0.50 sqm. |
| 41 | Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete |
| 42 | Providing and laying integral cement based water proofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces etc consisting of following operations: |
| 43 | (a) Applying a slurry coat of neat cement using 2.75 kg/sqm of cement admixed with water proofing compound conforming to IS. 2645 and approved by Engineer-in-charge over the RCC slab including adjoining walls upto 300 mm height including cleaning the surface before treatment. |
| 44 | (b) Laying brick bats with mortar using broken bricks/brick bats 25 mm to 115 mm size with 50% of cement mortar 1:5 (1 cement : 5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge over 20 mm thick layer of cement mortar of mix 1:5 (1 cement :5 coarse sand ) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge to required slope and treating similarly the adjoining walls upto 300 mm height including rounding of junctions of walls and slabs. |
| 45 | (c) After two days of proper curing applying a second coat of cement slurry using 2.75 kg/ sqm of cement admixed with water proofing compound conforming to IS : 2645 and approved by Engineerin- charge. |
| 46 | (d) Finishing the surface with 20 mm thick jointless cement mortar of mix 1:4 (1 cement :4 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineerin- charge including laying glass fibre cloth of approved quality in top layer of plaster and finally finishing the surface with trowel with neat cement slurry and making pattern of 300x300 mm square 3 mm deep. |
| 47 | (e) The whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing and for final test.“All above operations to be done in order and as directed and specified by the Engineer-in-Charge : |
| 48 | With average thickness of 120 mm and minimum thickness at khurra as 65 mm. |
| 49 | Providing gola 75x75mm in cement concrete 1:2:4 (1 cement :2 coarse sand : 4 stone aggregate 10 mm and down gauge) including finishing with cement mortar 1:3(1 cement : 3 fine sand) as per standard design |
| 50 | In 75x75mm deep chase |
| 51 | Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over P.V.C. sheet 1mx1mx400 micron, finished with 12mm cement plaster 1:3 (1 cement :3 coarse sand) and a coat of neat cement, rounding the edges and making and finishing the outlet complete. |
| 52 | Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08%and conforming to IS : 15622 , of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand) jointing with grey cement slurry @ 3.3kg/sqm including grouting the joints with white cement and matching pigments etc., complete. |
| 53 | Size of Tile 600x600 mm |
| 54 | 12 mm cement plaster of mix : (Inside) |
| 55 | 1:6 (1 cement: 6 fine sand) |
| 56 | 15 mm cement plaster on the rough side of single or half brick wall finished with a floating coat of neat cement of mix : |
| 57 | 1:6 (1 cement: 6 fine sand) |
| 58 | 6 mm cement plaster of mix : |
| 59 | 1:3 (1 cement: 3 fine sand) |
| 60 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. |
| 61 | Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade. |
| 62 | New work (two or more coats) over and including water thinnable priming coat with cement primer. |
| 63 | Finishing walls with Acrylic exterior paint of required shade : : |
| 64 | New work (Two or more coat and including priming coat of exterior primer applied @ 2.20 kg/10 sqm). |
| 65 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade : |
| 66 | Two or more coats on new work. |
| 67 | Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass/ stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) : |
| 68 | For fixed portion |
| 69 | Powder coated aluminium (minimum thickness of powder coating 50 micron) |
| 70 | For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately). |
| 71 | Powder coated aluminium (minimum thickness of powder coating 50 micron) |
| 72 | Providing and fixing ACP in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . |
| 73 | Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item): |
| 74 | With float glass panes of 5.00 mm thickness |
| 75 | Providing and fixing wire gauge in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item): |
| 76 | Providing and fixing anodised aluminium grill (anodised transparent or dyed to required shade according to IS: 1868 with minimum anodic coating of grade AC 15) of approved design/pattern, with approved standard section and fixed to the existing window frame with C.P brass/ stainless steel screws @ 200mm centre to centre, including cutting the grill to proper opening size for fixing and operation of handles and fixing approved anodised aluminium standard section around the opening, all complete as per requirement and direction of Engineer-in-charge. (Only weight of grill to be measured for payment) |
| 77 | Providing and fixing 100mm brass locks (best make of approved quality) for aluminium doors including necessary cutting and making good etc. complete. |
| 78 | Providing and fixing aluminum die cast body tubular type universal hydraulic door closer (having brand logo with IS: 3564, embossed on the body, door weight upto 35 kg and door width upto 700 mm), with necessary accessories and screws etc. complete : |
| 79 | Providing and laying RBM (River Bed Material) including loading, carrying, unloading, spreading, compacting and watering complete item. |
| 80 | Providing and injecting chemical emulsion for pre/post constructional Anti-termite treatment, creating continuous chemical barrier under and around the column pits, walls, trenches, basement excavation,top surface of the plinth filling, junction of wall and floor,along the external perimeter of building,expansion joints, over the top surface of consolidated earth on which apron is to be laid, surrounding of pipe and conduits with chloropyriphos emulsifiable concentrates of 20% concentration, including cost of chemical, diluting in water to 1% concentration, labour, HOM of equipments, complete as per specifications.(plinth area of building at ground floor only shall be measured). |
| 81 | Supply of Single-sided racks wall-mounted or back-to-wall storage units ideal for grocery stores,Racks must be powder-coated mild steel (MS) for rust resistance, with adjustable shelves (min. 50-75mm pitch). Minimum load capacity: 150 kg per shelf, uniformly distributed.With dimensions Height: 7 feet (2100-2200 mm),Width: 3 feet (900-1000 mm),Depth: 18-20 inches (450-500 mm) per side, Shelf thickness: 1.0-1.2 mm MS sheet,Upright frame: 50x75 mm box section, 1.5 mm thick.Material and Finish Primary material: CRCA mild steel or equivalent, GI pre-treated. Finish: Epoxy powder coating (60-80 microns), color RAL 9010 (white) or as specified. Back panel: Perforated 0.8 mm sheet for ventilation and hooks. Shelf load: 150 kg UDL (uniformly distributed load),Includes kick plates (100 mm high) and top shelf bracing, Anchoring: Wall/floor |
| 82 | Supply of free-standing, double-sided with 360-degree product visibility racks suitable for grocery aisles. Racks must be powder-coated mild steel (MS) for rust resistance, with adjustable shelves (min. 50-75mm pitch). Minimum load capacity: 150 kg per shelf, uniformly distributed.With dimensions Height: 7 feet (2100-2200 mm),Width: 3 feet (900-1000 mm),Depth: 18-20 inches (450-500 mm) per side, Shelf thickness: 1.0-1.2 mm MS sheet,Upright frame: 50x75 mm box section, 1.5 mm thick.Material and Finish Primary material: CRCA mild steel or equivalent, GI pre-treated. Finish: Epoxy powder coating (60-80 microns), color RAL 9010 (white) or as specified. Back panel: Perforated 0.8 mm sheet for ventilation and hooks. Shelf load: 150 kg UDL (uniformly distributed load),Includes kick plates (100 mm high) and top shelf bracing, Anchoring: Wall/floor |
| 83 | Good earth filling of low-lying areas/spots including digging,loading, carriage, unloading,laying, spreading, compacting, levelling etc. complete item including royalty charges. |
| 84 | Demolishing brick work manually/by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 meters lead as per direction of Engineer-in-charge: |
| 85 | In cement mortar |
| 86 | Dismantling roofing including ridges, hips valleys and gutters etc., and stacking the material within 50 meters lead of : |
| 87 | G.S. Sheet |
| 88 | Dismantling steel work manually/by mechanical means in built up sections without dismembering and stacking within 50 meters lead as per direction of Engineer-in-charge: |
| 89 | SUB-DISTRIBUTION BOARDS |
| 90 | Providing and fixing 6 amps to 32 amps rating 240 volts, 'L' series, miniature circuit breaker of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as reqired (category B) |
| 91 | Single Pole |
| 92 | Triple Pole and neutral |
| 93 | Triple Pole |
| 94 | Supply and fixing of following rating, 2P 230 volts, SPN in the existing MCB DB complete with connections, testing and commissiong etc. as required |
| 95 | 40 amps SPN |
| 96 | 63 amps SPN |
| 97 | EARTHING AND LIGHTNING PROTECTION |
| 98 | Earthing with GI earth plate 600mm x 600 mm x 6mm thick including accessories and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. (with charcoal or coke and salt) complete as required for earthing and lightning protection. |
| 99 | Providing and fixing 25 mm x 5mm GI strip from earth electrode as required |
| 100 | DISTRIBUTION BOARD |
| 101 | Supply, installation, testing at works, installation and commissioning of following distribution boards totally enclosed compartmentalized, cubicle indoor type fabricated with 16 SWG sheet steel, with Aluminium bus bars (both for main and neutral bus bars), complete with following switchgear/ mountings cable terminations, inter-connections as required, for 415 volts, 3 phase, 4 wire 50 HZ AC supply as per specifications and drawings. |
| 102 | Moulded case circuit Breakers shall be thermal magnetic trip type. Fault level for all MCCB and bus bar shall be 35 KA. ICU shall be equal to ICS=100% |
| 103 | Note : |
| 104 | All metering current transformers shall be Class 1, 15 VA. |
| 105 | MDB-1 (Indoor Type) |
| 106 | Incomer |
| 107 | 125 A 4P MCCB – 1No. |
| 108 | R,Y,B phase indicating lights with control fuses - 1 set |
| 109 | Bus Bar |
| 110 | 125 A 415V, 50Hz, 3ph, 4 wire Aluminium Bus bar |
| 111 | Outgoing |
| 112 | 40 Amp TPN - 2 No. |
| 113 | 63 Amp TPN - 2 No. |
| 114 | 40 Amp SPN - 1 No. |
| 115 | 63 Amp SPN - 1 No. |
| 116 | Supply and laying of PVC Power cable 1.1 KV Grade armoured aluminium XLPE cables including earth work, cost of end termination, thimbles and saddles etc. as required. |
| 117 | 3.5C x 95 sq.mm |
| 118 | SUB-DISTRIBUTION BOARDS |
| 119 | Supply and fixing of the following way, single pole and neutral / three pole and neutral, sheet steel, double door, phase segregation type, MCB distribution board, 230V / 415V on surface/recess, complete with tinned copper bus bar, neutral bus bar and link, earth bar, din bar, detachable gland plate, interconnections, including painting, earthing, etc., as required. |
| 120 | 4 way TPN |
| 121 | 12 way SPN |
| 122 | Supply and fixing 1x 20 watt aluminium housing tube light fitting including connection testing etc as req |
| 123 | Supply and fixing of 18 Watt LED Panel surface mounted including connection testing etc as reqd. (CAT No. LCDSPLN-R-18-CDL) |
| 124 | Supply and fixing of 70 Watt LED street light with GI pipe bracket with all accessories including connection testing. |
| 125 | WIRING |
| 126 | Wiring for light / fan / exhaust fan / call bell point with 1.5 Sq mm FR PVC insulated copper conductor cable in surface / recessed ISI marked PVC conduit(2mm thick) including modular switch, modular plate suitable box and earthing the point with 1.5 sq mm FRLS pvc insulated copper conductor single core cable etc as requried |
| 127 | Light point on board with copper wiring in ISI marked PVC conduit wiring for 3 Pin 6 amp plug point with 1.5sqmm PVC insulated multistrand copper conductor cable including P/F of modular switch, modular plate suitable box and earthing the point earth the as required with 01 No. PVIC insulated green colour wire. |
| 128 | Wiring for light plug with 2 x 2.5sq.mm. ISI marked PVC insulated copper conductor single core cable in surface / recessed ISI marked PVC conduit along with 1x 2.5 mm copper wire for loop earthing required |
| 129 | Wiring for power plug with 2 x 4 sq.mm. ISI marked PVC insulated copper conductor single core cable in surface / recessed ISI marked PVC conduit along with 1x4.0 Sq mm copper wire for loop earthing as required |
| 130 | Wiring for power plug with 2 x 1.5sq.mm. ISI marked PVC insulated copper conductor single core cable in surface / recessed ISI marked PVC conduit along with 1x1.5 Sq mm copper wire for loop earthing as required |
| 131 | Wiring for 1x 1.5sq.mm. ISI marked PVC insulated copper conductor single core cable in surface / recessed ISI marked in the existing PVC conduit etc. as required ( Invertor wiring ) |
| 132 | Wiring for sub main wiring with following sizes of PVC/ insulated copper conductor wires in the surface/ recessed PVC / MS conduit along with PVC insulated copper conductor earth wire as required complete with connections, testing and commissioning etc. as per specifications and drawings. |
| 133 | 2x6 sq mm with 1x6.0sqmm earth wire |
| 134 | Wiring for sub main wiring with4x10 sqmm alongwith 2x6sqmm earth wire sizes of PVC/ insulated copper conductor side core conductor in surface/recessed PVC conduit etc. as reqd. |
| 135 | Wiring for twin control light point with 2x1.5 sq. mm PVC insulated copper conductor cable in surface / recessed ISI marked PVC conduit with 2 way 6 Amp switch |
| 136 | Supplying and fixing suitable GI box with modular plate and cover in front on surface or in recess, including P/F 6 pin 15/16 amp and 5/6 amp modular socket outlet and 15/16 amp modular switch , connection testing etc as requried |
| 137 | Supplying and fixing of wall fan 400 mm sweep heavy duty with including connection, texting etc. as required. |
| 138 | Supply and fixing of 25 mm dia PVC conduit alongwith accessories in surface/recess. |
| 139 | Supply and fixing of 32 mm dia PVC conduit alongwith accessories in surface/recess. |
| 140 | Supply and fixing 20 Amp Industrial socket with 32 Amp SPN including connection, testing, etc. as required Please Enable Macros to View BoQ information |