| 1 | Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. |
| 2 | All kinds of soil. |
| 3 | Providing and laying in position cement concrete of specified grade excluding the cost of centring and shuttering. All work upto plinth level. |
| 4 | 1:2:4 (1 cement : 2 coarse sand(zone-III) : 4 graded stone aggregate 20 mm nominal size) |
| 5 | 1:3:6 (1 Cement : 3 coarse sand(zone-III) : 6 graded stone aggregate 20 mm nominal size). |
| 6 | 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size) |
| 7 | Providing and laying in position specified grade of reinforced cement concrete excluding the cost of centring, shuttering, finishing and reinforcement- All work upto plinth level. |
| 8 | 1:1.5:3 (1 cement: 1.5 coarse sand: 3 graded stone aggregate 20 mm nominal size) |
| 9 | Centring and shuttering including strutting, propping etc. and removal of form for |
| 10 | Foundations, footings, bases of columns etc. for mass concrete. |
| 11 | Suspended floors, roofs, landings, balconies and access platform. |
| 12 | Edges of slabs and breaks in floors and walls |
| 13 | Under 20 cm wide |
| 14 | Reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete |
| 15 | Cold twisted bars/ mild steel and MT steel |
| 16 | Brick work with common burnt clay (non-modular) bricks of class designation 7.5 (at all levels): |
| 17 | Cement mortar 1: 6 (1 cement: 6 coarse sand) |
| 18 | Half brick masonry with common burnt clay (non-modular) bricks of class designation 7.5 (at all levels). |
| 19 | Cement mortar 1:4 ( 1 cement : 4 coarse sand) |
| 20 | Providing and laying Ceramic glazed floor tiles 300x300 mm (thickness to be specified by the manufacturers) of 1st quality conforming to IS: 15622 of approved make, laid on 20 mm thick bed of cement mortar 1: 4 ( 1 cement : 4 coarse sand) including pointing the joints with white cement and matching pigment etc., complete. |
| 21 | In colour such as White, Ivory, Grey, Fume Red Brown |
| 22 | Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622 of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1cement :4 coarse sand) including grouting the joints with white cement and matching pigments etc. complete |
| 23 | Size of tile 600x600 mm |
| 24 | Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer) with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make in all colours & shade in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1cement: 3 coarse sand), jointing with grey cement slurry @ 3.3kg/sqm including grouting the joint with white cement & matching pigments etc. complete. |
| 25 | Size of tile 600x600 mm |
| 26 | Kota stone slab flooring 25 mm thick over 20mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment tomatch the shade of the slab, including rubbing, polishing and curing complete with base of cement mortar 1:4 (1 cement : 4 coarse sand) : |
| 27 | Kota stone slab 20 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm ( average) thick cement mortar 1:3 (1 cement:3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing, polishing and curing complete. |
| 28 | 12 mm cement plaster finished with a floating coat of neat cement of mix : |
| 29 | 1:4 (1 cement: 4 fine sand) |
| 30 | 15 mm cement plaster on the rough side of single or half brick wall of mix : |
| 31 | 1:6 (1 cement: 6 fine sand) |
| 32 | Providing and applying white cement based putty of specified thickness, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. |
| 33 | 1 mm thick |
| 34 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade, one or more coats on old work. |
| 35 | Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade. |
| 36 | New work (two or more coats) over and including water thinnable priming coat with cement primer. |
| 37 | Finishing walls with acrylic smooth exterior paint of required shade on New work (Two or more coats applied @ 1.67 liter/10sqm over and including priming coat of exterior primer applied @2.20kg/10sqm) |
| 38 | Repairs to plaster of thickness 12mm to 20 mm in patches of area 2.5 sq. meters and under, including cutting the patch in proper shape raking out joints and preparing and plastering the surface of the walls complete including disposal of rubbish to the dumping ground within 50 meters lead |
| 39 | With cement mortar 1:4 (1 cement : 4 fine sand) |
| 40 | Providing gola 75x75mm in cement concrete 1:2:4 (1 cement :2 coarse sand : 4 stone aggregate 10 mm and down gauge) including finishing with cement mortar 1:3(1 cement : 3 fine sand) as per standard design |
| 41 | Grading roof for water proofing treatment with Cement mortar (1:4) including mixing waterproofing compond. |
| 42 | Demolishing cement concrete manually/by mechanical means including disposal of material within 50 meters lead as per direction of Engineer-incharge: |
| 43 | Nominal concrete 1:3:6 or richer mix (i/c equivalent design mix) |
| 44 | Dismantling tile work/kota in floors and roofs laid in cement mortar including stacking material within 50 meters lead. |
| 45 | For thickness of tiles10 mm and upto 25 mm. |
| 46 | Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass/ stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) : |
| 47 | For fixed portion |
| 48 | Powder coated aluminium (minimum thickness of powder coating 50 micron) |
| 49 | For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately). |
| 50 | Powder coated aluminium (minimum thickness of powder coating 50 micron) |
| 51 | Providing and fixing glazing in aluminum door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineerin-charge. (Cost of aluminum snap beading shall be paid in basic item.) |
| 52 | With float glass panes of 5.0 mm thickness (weight not less than 12.50 kg / sqm) |
| 53 | Providing and fixing Brass 100mm mortice latch and lock with 6levers without pair of handles (best make of approved quality) for aluminium doors including necessary cutting and making good etc. complete. |
| 54 | Providing and fixing ACP in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . |
| 55 | Providing and fixing PVC pipe of approved make with necessary accessories etc complete (100 mm) Please Enable Macros to View BoQ information |