| 1 | Deployment of Standby Power Facility for NICU and PICU at Dr. R. N. Cooper Hospital. |
| 2 | Excavation for foundations, substructures, |
| 3 | Providing & Laying dry stone Rubble Soling |
| 4 | Mild steel bars |
| 5 | Nominal Mix of 1:1:2 (1 cement OPC: 1 |
| 6 | For Steelwork Painting |
| 7 | Providing and fixing UV resistant selffit UPVC pipes of approved make for Rainwater downtakes confirming to IS 13592:1992 Type A suitable for 4kg/sqcm pressure for following pipe diameters including rain water receiving recess with pvc plug bend necessary fittings such as offset sshoes, fixing the pipes on wall with clips filling the joints with solvent/cement and necessary scafolding etc. Complete as directed by Engineer In Charge. 150mm dia |
| 8 | Providing, detailing, composite fabricating members likeTrusses, N-girders, girders, bracings, supports, purlins,runners, and similar structural steel members fabricated using M.S. hollow tubular steel sections (circular & rectangular pipes), of TATA Structura Make or equivalent conforming to IS 1239 part 1 and 2 and of grade Fe 250 as per specifications and approved fabrication drawings (which are to be prepared by Contractor and got approved from Engineer), including transportion of the same to site, erection of structural steel members for all heights & at all levels, provision of necessary erection bolts, fixing bolts, nuts, washers, cleats, stiffeners, gussets, base plate, and all necessary operations like preheating as per specifica tions, straightening, bending, cutting, drilling, grinding, machining if specified, welding, grinding, removing the welding burr and preparing surface for painting with wire brush cleaning and applying two coats of epoxy red oxide zinc phosphate primer of 30 microns each and two coats of Epoxy Corrosion Resistant Enamel paint of 30 microns after fabrication including touching up with spray painting after erection etc complete as directed by Engineer In Charge. |
| 9 | Providing, detailing, fabricating and fixing at desired location using M.S. chequered Plates of any thickness and of grade Fe 250 as per specifications and approved fabrication drawings (which are to be prepared by Contractor and got approved from Engineer), including transporation of the same to site, erection at all heights and levels, provision of necessary erection bolts, fixing bolts, nuts, washers, cleats, stiffeners, and all necessary operations like preheating as per specifications, straightening, bending, cutting, drilling, grinding, machining if specified, welding, grinding and removing the welding burr and preparing surface for painting with wire brush cleaning and applying two coats of epoxy red oxide zinc phosphate primer of 30 microns each and two coats of Epoxy Corrosion Resistant Enamel paint of 30 microns after fabrication including touching up with spray painting after erection etc complete as directed by Engineer In Charge. |
| 10 | Providing and fixing the Mechanical Anchor Fasteners as specified below of Hilti Make or equivalent confirming to IS 1367 (Part 3) at required locations and level including drilling the hole, cleaning and anchoring the bolt as per manufacturers specifications etc. complete as directed by Engineer In Charge. M20 |
| 11 | Mild steel grill of weight 20 to 25 Kg/sq. m |
| 12 | Bare Galvalume/zincalume sheets for roofing |
| 13 | Colour Coated Galvalume/Zincalume ridge. |
| 14 | Providing and fixing in position collapsiblel gate |
| 15 | Cranes 5 tonnes capacity |
| 16 | 600 X 600 X 3.15 mm Copper Plate, 3000mm dip with suitable size cu strip earth pit as per IS 3043. The earth pit shall be provided with watering pipe (Class B) with wire messed funnel, 25X3 cu strip / 2X8SWG Cu.wire up to chamber, disconnecting links with 600 x 600 mm (clear) RCC chamber & 3mm thick heavy duty CI chequered plate cover with hinge. Bentonite shallbe provided for earth pits. Excavation, back filling, removal of excess soil is included in the scope. |
| 17 | Earthing Continuity Conductors -50 x 6mm GI |
| 18 | 1st category Al armoured cables FRLS outer sheathed- 35 Sq.mm 3.5C x |
| 19 | 1st category Cu armoured cables FRLSZ outer sheathed- 4C x 2.5 Sq.mm. |
| 20 | Excavating the trenches and refilling the same after the cable is laid in approved manner (Size of trench: 750 mm deep, 600 mm wide) in concrete/ masonary / asphalt. 1 Cu. Mtr. = 2.2 RMT. And reinstatement. |
| 21 | Cable End Termination For AL Cables 3.5C x 35 Sq.mm. |
| 22 | Cable End Termination Copper Cables – 4C x 2.5 Sq.mm |
| 23 | 1st category Cu armoured cables FRLS outer sheathed - 3C x 2.5 Sq.mm |
| 24 | Wiring for submains- medium class PVC 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire in 20mm Conduit |
| 25 | SITC LED Flood Light Fitting -150 W |
| 26 | Supply & laying I.S.I. mark 'B' class GI Pipe -100 mm dia. |
| 27 | IP 42 Wall/column Mounted distribution board with one Nos of DP 16/32A MCB as incomer and 6 Noss 6A/10A SP MCB as outgoing (12 way SPN DB) |
| 28 | 50mm x 50mm x 50mm size GI Junction box with kNosck out & 10Amp. Connector block /strip |
| 29 | SITC OF AUTOMATIC MAINS FAILURE PANEL SUITABLE TO DG SET -50KVA |
| 30 | 100 Amp. 415V 4P Changeover Switch with CRCA sheet steel powder coated enclosure |
| 31 | Garden Light LED Luminiare Bollard Type |
| 32 | LED Bulkhead fitting |
| 33 | 10A SP MCB |
| 34 | Oil Filter & Fuel Filter Set |
| 35 | Air Filter (2H.277.05.0.00) |
| 36 | Engine Oil (15 W 40) |
| 37 | Coolant Inhibitor |
| 38 | All Engine Belt Set ( Radiator Fan Belt, Charging Alternator Belt) |
| 39 | Diesel Tank Cleaning |
| 40 | Engine Overhauling and Servicing Job |
| 41 | Battery 12 Volt 150 Ah ( Liquid Base) with Cable Terminal Set. Please Enable Macros to View BoQ information |