| 1 | 1) : Removing Manglore tiled roof and ridge tiles with battens, ridge and barge boards, eaves 8 A boards etc and sacking the materials as directed with all leads and lifts complete. Including removing wood work below etc. complete. |
| 2 | 2) Removing doors and windows with frames and stacking the materials as directed with all leads, lifts etc. complete. |
| 3 | 3) Removing King Post truss from roof and stacking the materials as directed with all leads and lifts etc. complets |
| 4 | 4)Providing and fixing seasoned and treated non teakwood frame as per drawing for second class doors without ventilators, windows, fanlights etc., including all mouldings, rebating, holdfast and finishing with one coat of primer complete. |
| 5 | 5) Providingand fixingCountrycut teakwooddoubleor single leaf secondclass fullypanelleddoor shutterwith35mmthick styleand railwith25mmthickpanelswithopenablefanlightasperdetailed drawings.Excludingthedoorframe60mmx100mmstainlesssteelfixturesand fastening and finishing thewoodworkwith oil painting3 coats. (Excluding the door frame) |
| 6 | 6) Providing and fixing mild steel grill work for windows, ventilators weighing 15 kg per sq.m as per drawing , including necessary fixtures welding and painting with one coat of anti- corrosive paint etc . complete.- |
| 7 | 7) Providing structural steel work in trusses other similar trussed purlins and members with all bracing, gusset plates etc.asper detailed design and drawings or as directed by Engineer in Charge including cutting fabricating hoisting erecting fixing in position making riveted/bolted/welded connectedand one coat of anticorrosive paint and over it two coats oilpainting of approved quality and shade complete |
| 8 | 8) Resetting fixing Manglore tiles with AA tiles including scaffolding to M.T. roofing excluding wood work etc completeR.A. |
| 9 | 9) Fixing Mangalore type ridge and hip tiles class \\"AA\\" tiles, including scaffolding if necessary, pointing with coloured cement mortar and curing complete |
| 10 | 10) Supplying manglore Tiles material rate |
| 11 | 11) Supplying manglore type Ridge Tiles mateial rate |
| 12 | 12) Providing and fixing colour coated Zincalume ( R ) AZ150 ( min 150 gms/sq.mt. total on each side ) profiled sheets for roofing. The feed material is manufactured out of nominal 0.45 mm Base Metal Thickness ( BMT ) (0.5 mm TCT ), Hi-strength steel with min.550 MPa yield strength, metallic hot dip coated with Aluminium-Zinc alloy (55% aluminium 43.4% zinc 1.6% silicon) with COLORBOND ( R ) steel quality super durable polyester paint coat ( with inorganic pigment). The paint shall have a total coating thickness of nominal 35 um, comprising of nominal 25 um exterior coat on top surface and nominal 10 um reverse coat on back surface. Profile sheet shall have nom. 950-1050 mm effective cover width and nominal 25-30 mm deep ribs with subtle square fluting in the five pan at nominal 180-250 mm center- to-center. The end rib shall be designed for anti-capillary groove. and return leg. The feed material should have coil manufacturers product details marked a regular interval. Including fasteners with min. fastened with min. 25 um Zinc-Tin alloy coated, Hex head, self-drilling screw etc. complete. (weight of profile 4.52 Kilogram/ One Square Metre) Item No. 38.34 1173/smt. |
| 13 | 13) Providing and fixing of colour coated Zincaluminium( R ) AZ150 ( min 150 gms/sq.mt. total on each side ) profiled sheets for roofing. The feed material is manufactured out of nominal 0.45 mm Base Metal Thickness ( BMT ) (0.5 mm TCT ), Hi-strength steel with min.550 MPa yield strength, metallic hot dip coated withAluminium-Zinc alloy (55% aluminiumm 43.4% zinc 1.6% silicon) with COLORBOND ( R ) steel quality super durable polyster paint coat ( with inorganic pigment). The paint shall have a total coating thickness of nominal 35 mm, comprising of nominal 25mmexterior coat on top surface and nominal 10 um reverse coat on back surface. Profile sheet shall have nom. 950-1050 mm effective cover width and nominal 25-30 mm deep ribs with sublet square fluting in the five pan at nominal 180-250 mmcenter- to-center. The end rib shall be designed for anti-capacity groove. and return leg. The feed material should have coil manufacturers product details marked a regular interval. including fasteners with min. fastened with min. 25 um Zinc-Tin alloy coated, Hex head, self-drilling screw etc. complete. (weight of profile 4.52 Kilogram/ One Square Metre) 600 mm girth (Surface Width). Item No. 38.35 751/ Rmt |
| 14 | 14) Providing lat. Stone masonry in C.M. 1:6 for superstructure includng racking out joints when plastering is to be done/striking joints when no plastering is to be done watering and scaffolding SE circular date 23-9-2022 comp. rate 6509/- R.A. |
| 15 | 15) Providing internal /external cement plaster 20mm. thick in Single coats in cement mortar 1:3 without neeru finish, to concrete, brick surface, in all positions including scaffolding and curing etc. complete. Bd.L.4 Page One Number 368 Item No. 32.08 393/ smt R.A. |
| 16 | 16) Providing and laying Cast in situ/Ready Mix cement concrete in M-10 of trap/ granite/ quartzite/ gneiss metal for foundation and bedding including bailing out water, Steel centering, formwork, laying/pumping, compacting, roughening them if special finish is to be provided, finishing if required and curing complete, with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade) Bd. E. 1 Page One Number 287 Item NO. 24.01 5830/ cmt R.A. |
| 17 | 17) Providingandlayingvitrifiedmattfininshtiles havingsize590mmto605mmxto605mmof 8 to 10 mm thickness and confirming IS. 15622-2006 (Group Bla) ofapprovedmake,shade and pattern for flooring in required position laid on a bedof 1:4 cement morarincludingneatcementfloat,fillingjoints,curingandcleaningetc.complete 33.42 |
| 18 | 18) Providing and applyingthree coats of water proof cement paint of approved manufactureand of approved colour to new plastered surfaces includingscaffolding if necessary,cleaning and preparing the surface, watering for two days etc. complete. .35.15 |
| 19 | 19) Providing and applying washable oil-bound distemper of approved colourand shadeto old and new surfaces in two coats including scaffolding, preparing the surfaces.(excluding the primer coat.) etc. complete. |
| 20 | 20) Providing and fixing Country cut teak wood windows with double leaf 25mm thickplanked shutters without ventilators as per detailed drawings including stainlesssteel fixtures andfasteningsandfinishingthewoodworkwithoilpainting3coatsetc.Complete |
| 21 | 21) Providing and fixing name board etc. Complete Please Enable Macros to View BoQ information |