| 1 | Blood Administration Set / Blood Transfusion Set• Sharp and easy piercing spike suitable for blood bags and standard blood containers• Transparent cylindrical drip chamber with filter.Filter size should be 200+20 micrometer.• 150 cm long smooth kink resistant tubing• Efficient roller clamp to control and adjust the transfusion rate• As per IS 9824 (Part 3):1996 |
| 2 | Suction Catheter, Sterile. Size: FG 6 (For use in respiratory tract)• Soft, kink resistant tubing• Rounded open tip with lateral eye• Colour coded universal funnel connector for safe connection to standard suction equipment• Length 50 cm (min.)• As per IS0 8836:2014 |
| 3 | Suction Catheter, Sterile. Size: FG 8 (For use in respiratory tract)• Soft, kink resistant tubing• Rounded open tip with lateral eye• Colour coded universal funnel connector for safe connection to standard suction equipment• Length 50 cm (min.)• As per IS0 8836:2014 |
| 4 | Suction Catheter, Sterile.Size: FG 10 (For use in respiratory tract)• Soft, kink resistant tubing• Rounded open tip with lateral eye• Colour coded universal funnel connector for safe connection to standard suction equipment• Length 50 cm (min.)• As per IS0 8836:2014 |
| 5 | Suction Catheter, Sterile. Size: FG 12 (For use in respiratory tract)• Soft, kink resistant tubing• Rounded open tip with lateral eye• Colour coded universal funnel connector for safe connection to standard suction equipment• Length 50 cm (min.)• As per IS0 8836:2014 |
| 6 | Suction Catheter, Sterile. Size: FG 14 (For use in respiratory tract)• Soft, kink resistant tubing• Rounded open tip with lateral eye• Colour coded universal funnel connector for safe connection to standard suction equipment.• Length 50 cm (min.)• As per IS0 8836:2014 |
| 7 | Suction Catheter, Sterile. Size: FG 16 (For use in respiratory tract)• Soft, kink resistant tubing• Rounded open tip with lateral eye• Colour coded universal funnel connector for safe connection to standard suction equipment• Length 50 cm (min.)• As per IS0 8836:2014 |
| 8 | Suction Catheter, Sterile.Size: FG 18 (For use in respiratory tract)• Soft, kink resistant tubing• Rounded open tip with lateral eye •Colour coded universal funnel connector for safe connection to standard suction equipment.• Length 50 cm (min.)• As per IS0 8836:2014 |
| 9 | Sterile Catheter, Single Use, for Urinary Drainage (Foley Balloon Catheter), 2 Way, Size 8 FG• Made of Silicone elastomer bonded with Latex• Should have hard plastic valve• Smooth distal end with smooth eyes for atraumatic intubation.• Symmetrical foley balloon• Balloon capacity 3- 5 ml• As per IS 11497• Color coding marking to identify size.• Length, wall thickness and balloon capacity should be mentioned as per IS 11497.• Specification for B,C,D,E,F,G should be mentioned as per IS 11497 for particular size |
| 10 | Sterile Catheter, Single Use, for Urinary Drainage (Foley Balloon Catheter), 2 Way, Size10 FG• Made of Silicone elastomer bonded with Latex• Should have hard plastic valve• Smooth distal end with smooth eyes for atraumatic intubation.• Symmetrical foley balloon• Balloon capacity 3- 5 ml• As per IS 11497• Color coding marking to identify size• Length, wall thickness and balloon capacity should be mentioned as per IS 11497.• Specification for B,C,D,E,F,G should be mentioned as per IS 11497for particular size. |
| 11 | Sterile Catheter, Single Use, for Urinary Drainage (Foley Balloon Catheter), 2 Way, Size16 FG• Made of Silicone elastomer bonded with Latex• Should have hard plastic valve• Smooth distal end with smooth eyes for atraumatic intubation• Symmetrical foley balloon• Balloon capacity 30 ± 1 ml• Should conform to IS 11497• Color coding marking to identify size.• Length, wall thickness and balloon capacity should be mentioned as per IS 11497.• Specification for B,C,D,E,F,G should be mentioned as per IS11497 for particular size |
| 12 | Sterile Catheter, Single Use, for Urinary Drainage (Foley Balloon Catheter), 2 Way, Size18 FG.• Made of Silicone elastomer bonded with Latex.• Should have hard plastic valve.• Smooth distal end with smooth eyes for atraumatic intubation.• Symmetrical foley balloon.• Balloon capacity 30 ± 1 ml.• Should conform to IS 11497.• Color coding marking to identify size.• Length, wall thickness and balloon capacity should be mentioned as per IS 11497.• Specification for B,C,D,E,F,G should be mentioned as per IS11497 for particular size |
| 13 | Sterile Catheter, Single Use, for Urinary Drainage (Foley Balloon Catheter), 2 Way, Size20 FG.• Made of Silicone elastomer bonded with Latex.• Should have hard plastic valve.• Smooth distal end with smooth eyes for atraumatic intubation.• Symmetrical foley balloon.• Balloon capacity 30 ± 1 ml.• As per IS 11497.• Color coding marking to identify size• Length, wall thickness and balloon capacity should be mentioned as per IS 11497.• Specification for B,C,D,E,F,G should be mentioned as per IS11497 for particular size |
| 14 | Sterile Catheter, Single Use, for Urinary Drainage (Foley Balloon Catheter), 2 Way, Size22 FG• Made of Silicone elastomer bonded with Latex• Should have hard plastic valve• Smooth distal end with smooth eyes for atraumatic intubation.• Symmetrical foley balloon.• Balloon capacity 30 ± 1 ml.• As per IS 11497.• Color coding marking to identify size.• Length, wall thickness and balloon capacity should be mentioned as per IS 11497.• Specification for B,C,D,E,F,G should be mentioned as per IS11497 for particular size |
| 15 | Sterile Catheter, Single Use, for Urinary Drainage (Foley Balloon Catheter), 2 Way, Size 24 FG • Made of Silicone elastomer bonded with Latex • Should have hard plastic valve• Smooth distal end with smooth eyes for atraumatic intubation• Symmetrical foley balloon• Balloon capacity 30 ± 1 ml• As per IS 11497• Color coding marking to identify size. • Length, wall thickness and balloon capacity should be mentioned as per IS 11497. • Specification for B,C,D,E,F,G should be mentioned as per IS 11497 for particular size |
| 16 | Infant Feeding Tube Size:10FG length 50 cm (min.)• Two lateral eyes at distal end • Soft, kink resistant non- toxic PVC tubing, non irritant to delicate mucosa • With female flexible mount with in-built closure • Radio opaque line • Sterile |
| 17 | Infant Feeding Tube Size:8FG, length 50 cm (min.)• Two lateral eyes at distal end• Soft, kink resistant non- toxic PVC tubing, non irritant to delicate mucosa• With female flexible mount with in-built closure• Radio opaque line.• Sterile |
| 18 | Infant Feeding Tube Size:5FG length 50 cm (min.)• Two lateral eyes at distal end • Soft, kink resistant non- toxic PVC tubing, non irritant to delicate mucosa.• With female flexible mount with in-built closure.• Radio opaque line.• Sterile |
| 19 | Sterile Disposable Infusion Set with Microdrip (I.V.)• Microdrip Infusion set with drop size reduced to approx 60 drops per ml.• Sharp and easy piercing spike.• Transparent and flexible drip chamber.• 150 cm long smooth kink resistant tubing.• Efficient roller clamp to control and adjust the fluid rate.• As per IS 12655 - 4 standard |
| 20 | Insulin syringe ( 40 units) with (fixed) 30 G needle As per IS 12227 |
| 21 | Mucus Extractor Sterile• Clear transparent container• Antibacterial filter• Soft, kink resistant PVC tubing• Tube Size 10 FG; Length 40 cm (min.)• Capacity 25 ml |
| 22 | Nasal Oxygen Cannula (Set), Twin Bore (accessory for compressed air breathing) All Sizes (Adult)• Soft and kink resistant PVC tubing• Multichannel / star lumen to preventing accidental kinking• Twin bores should ensure equal volume of oxygen to both air passages.• Connector for easy connection to the oxygen source.• Tube length 200 cm. |
| 23 | Nasal Oxygen Cannula (Set), Twin Bore (accessory for compressed air breathing) All Sizes (Pediatrics)• Soft and kink resistant PVC tubing• Multichannel / star lumen to preventing accidental kinking• Twin bores should ensure equal volume of oxygen to both air passages• Connector for easy connection to the oxygen source• Tube length 200 cm |
| 24 | Plaster of Paris Bandages 10cm X 2.7mts / Roll Testing Parameter Should Be Followed As Per BPStandard |
| 25 | Ryle's Tube / NasogastricTube (P.V.C.) with radio opaque lining. Size: 10• Soft, kink resistant PVC tubing for atraumatic intubation• Closed distal end should be coned with radio opaque material for accurate intubation• Four lateral eyes for greater efficiency• Radio opaque line• Marking at 50, 60, 70 cm from tip• Colour coded funnel• With luer connector / closure• Length 105 cm |
| 26 | Ryle's Tube / Nasogastric Tube (P.V.C.) with radio opaque lining. Size: 12• Soft, kink resistant PVC tubing for atraumatic intubation• Closed distal end should be coned with radio opaque material for accurate intubation• Four lateral eyes for greater efficiency• Radio opaque line• Marking at 50, 60, 70 cm from tip• Colour coded funnel• With luer connector / closure• Length 105 cm |
| 27 | Ryle's Tube / Nasogastric Tube (P.V.C.) with radio opaque lining. Size: 14• Soft, kink resistant PVC tubing for atraumatic intubation• Closed distal end should be coned with radio opaque material for accurate intubation• Four lateral eyes for greater efficiency• Radio opaque line• Marking at 50, 60, 70 cm from tip• Colour coded funnel• With luer connector / closure• Length 105 cm |
| 28 | Ryle's Tube / NasogastricTube (P.V.C.) with radio opaque lining. Size: 16• Soft, kink resistant PVC tubing for atraumatic intubation• Closed distal end should be coned with radio opaque material for accurate intubation• Four lateral eyes for greater efficiency• Radio opaque line• Marking at 50, 60, 70 cm from tip• Colour coded funnel • With luer connector / closure• Length 105 cm |
| 29 | Ryle's Tube / Nasogastric Tube (P.V.C.) with radio opaque lining. Size: 18• Soft, kink resistant PVC tubing for atraumatic intubation• Closed distal end should be coned with radio opaque material for accurate intubation• Four lateral eyes for greater efficiency• Radio opaque line• Marking at 50, 60, 70 cm from tip• Colour coded funnel• With luer connector / closure• Length 105 cm |
| 30 | Scalp Vein Set (Disposable):Size 18G• Butterfly shaped wings for easy handling and attachment with skin. Colour coded• Needle should be bevelled, siliconised and should ensure atraumatic cannulation• Female luer fitting at one end• Soft, kink resistant, non- toxic, non irritant tube• Sterile |
| 31 | Scalp Vein Set (Disposable): Size 20G• Butterfly shaped wings for easy handling and attachment with skin. Colour coded• Needle should be bevelled, siliconised and should ensure atraumatic cannulation• Female luer fitting at one end• Soft, kink resistant, non- toxic, non irritant tube• Sterile |
| 32 | Scalp Vein Set (Disposable): Size 22G• Butterfly shaped wings for easy handling and attachment with skin. Colour coded• Needle should be bevelled, siliconised and should ensure atraumatic cannulation• Female luer fitting at one end• Soft, kink resistant, non- toxic, non irritant tube• Sterile |
| 33 | Scalp Vein Set (Disposable): Size 24G• Butterfly shaped wings for easy handling and attachment with skin. Colour coded• Needle should be bevelled, siliconised and should ensure atraumatic cannulation• Female luer fitting at one end• Soft, kink resistant, non- toxic, non irritant tube• Sterile |
| 34 | \\"Multistix test strips1. Urine strip use for semi quantitative analysis for 10 parameters:(a) Glucose(b) Protein(c) pH(d) Specific Gravity(e) Nitrite(f) Urobilinogen(g) Blood(h) Ketone(i) Leucocytes(j) Bilirubin2. Interpretation of the result should be both by visual reading by comparing with color scale on label and strip analyser.3. Strip should be CE certified and IVD approved.4. It should read the result within 60 second.5. It should have instruction manual (Hindi and English) for detail information regarding use of strip and principle of various parameters.6. It should have following sensitivity /reference values:-Glucose : <25mg/dlProtein < 15mg/dlpH : 5.5-7.0Specific Gravity : 1.015-1.025Nitrite : Negative :PositiveUrobilinogen : < 17 µ mol/LBlood : Negative : PositiveKetone : <2.0 mg/dlLeucocytes : <10 leu/µlBilirubin : <0.2mg/dle7. Strip should be stable at +2°C to +30°C.8. It should have pack size 1×100 strip.9. Shelf life of the strip must be one year from the date of supply with open vial stability of strip must be at least three months.10. Firm/Manufacturer should have its manufacturing & R&D unit in India.\\" Please Enable Macros to View BoQ information |