| 1 | Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing) and disposal of debris and rubbish complete all as specified and directed. |
| 2 | M & L for 25 mm thick, plain cement concrete 1:2:4, type B-0 (using 12.5 mm graded stone aggregate) as in sub-base of flooring, etc and finished the surface even and rough complete all as specified and directed. |
| 3 | M & L for non-skid, ceramic, coloured tiles 7 to 8 mm thick (square/rectangular) area of each tile exc 0.18 sqm but n.exc 0.38 sqm, in floors etc, and set & jointed in neat cement slurry and pointed in white or coloured cement to match with the shade of tiles including 15 mm thick screed bed in cement mortor 1:6 complete all as specified and directed. |
| 4 | Dismantling Stone slabs and tiles of any description or thickness in floors, aprons etc complete all as specified and directed. |
| 5 | M & L for 75 mm thick, plain cement concrete 1:3:6, type C-2 (using 40 mm graded stone aggregate) as in sub-base of flooring, etc complete all as specified and directed. |
| 6 | M & L for Machine cut kota stone slab flooring 20-25mm thick over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete with including 15 mm thick screed bed in cement mortor 1:6 complete all as specified and directed. |
| 7 | Demolition of un-reinforced cement concrete in ground floors and pavings n.exc 15cm thickness, (Below or above Ground level) and disposal of debris and rubbish to a distance complete all as directed by the Engr-in-Charge |
| 8 | M & L for 75 mm thick, plain cement concrete 1:3:6, type C-2 (using 40mm graded stone aggregate) as in plinth protection etc, finishing cement concrete surface even and smooth without using extra cement including making joints with bitumastic filing in proportion of bitumen and sand 1:2 complete all as specified and directed. |
| 9 | M & L for 100 mm thick, plain cement concrete 1:4:8, type D-2 (using 40 mm graded stone aggregate) as in sub-base of flooring, etc complete all as specified and directed. |
| 10 | Sand filling under floors or in foundations including watering and consolidation and including spreading & well ramming in layers not exc 25 cm complete all as specified and directed. |
| 11 | M & L for Machine pressed precast conctete interlocking paver block any shape and size confirming to IS 15658-2006 of 80 mm thickness, M-40 Grade with grey cement and pigment complete all as specified and directed. |
| 12 | Dismantling wrought iron or mild steel work of any description complete all as specified and directed. |
| 13 | S&F Steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I. S.1161- 979 grade St.-240 complete all as specified and directed. |
| 14 | Dismantling of plain or corrugated steel sheeting, any gauge, thickness, in roof covering including ridges and keeping serviceable sheets in safe custody for reuse in the work complete as directed. |
| 15 | S & F Pre-Painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as per manufacturer's instruction complete all as specified and directed. |
| 16 | S & F Pre-Painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in ridges/vally gutter, fixed with self tapping screws as per manufacturer's instruction complete all as specified and directed. |
| 17 | Demolition of brick work or stone / boulder masonry/ precast concrete block masonry, built in cement mortar including all quoins, pillars etc stacking the serviceable bricks after removing mortar and cleaning for re-use and disposal of debris and rubbish complete all as directed by the Engr-in-Charge. |
| 18 | M & L for Pre-cast cement concrete 1:3:6, type C-1 (using 20mm graded stone aggregate), block masonry with solid blocks of size 300x200x200mm or 300x200x100mm, having compressive strength of not less than 100 Kg/Sq Cm (As per IS-2185) exc. 10 cm in width and setting in mortar 1:6 complete all as specified and directed. |
| 19 | M & L for Pre-cast cement concrete 1:3:6, type C-1 (using 20mm graded stone aggregate), block masonry with solid blocks of 10cm thick, having compressive strength of not less than 100 Kg/Sq Cm (As per IS-2185) n exc. 10 cm in width and including setting in mortar 1:4 complete all as specified and directed. |
| 20 | M & L for rendering 15 mm thick on fair faces of brick work or concrete surfaces in cement mortar 1:6 and finished the surfaces even and smooth without using extra cement complete all as specified and directed. |
| 21 | Taking down cement plaster on brick or stone walls etc including racking out joints, hacking for key, scrubbing down with water and removing rubbish complete all as specified and directed |
| 22 | M & L for rendering 15 mm thick in two coats (10mm+5mm each) on fair faces of brick work or concrete surfaces in cement mortar 1:4, mixed with integral water proofing compound with weight of cement in top layer as per manufacturer's instructions and finished the surface even and fair without using extra cement complete all as specified and directed. (Note : WPC shall be measured and paid separately against respective item). |
| 23 | Sypply only Integral waterproofing compound conforming to IS 2645 (2003) complete all as specified and directed. |
| 24 | M & L for Preparation of newly plastered surfaces of walls and applying two coats of cement base paint over a coat of alkali resistant primer complete all as specified and directed. |
| 25 | M & L for preparing newly plastered surfaces of internal walls, etc and applying two coats of oil emulsion distemper over a coat of alkali resistant primer and over one or more coats of wall care putty to a smooth surface complete all as specified and directed. |
| 26 | Dismantling Wall and ceiling boards (fibre, pulp, insulation, etc.) or insulation boards/slabs/ blankets, any thickness, including cover fillets/ snap grid frame etc complete all as specified and directed. |
| 27 | S & F aluminium Anodised snap grid frame work of size 605mm x 605mm frame work for ceiling with aluminium T section of size 38mm x 25mm x 1.5mm thick for main runners, 25x25x1.5mm thick for cross runner and angle size 25x25x1.5mm thick alongwith wall suspended and including Hangers 4 mm dia. G.I. (upto 1200mm length) adjusting level fixed to ceiling members in proper position, fixed with aluminium staple on snap grid as per manufacturer's instructions including 6 mm thick non asbestos E-board, HSPC, designer fixed to frame complete all as specified and directed by the Engr-in-Charge. |
| 28 | Taking down chowkats or frame, n.exc 1.5 Sqm each with shutters (without taking off shutter from the frame) complete all as specified and directed. |
| 29 | S & F Steel windows with side hung shutters including projecting type hinges with steel handle, and steel peg stay, complete without glazing bars, dovetailed or welded complete all as specified and directed. |
| 30 | S & F 4 mm thick, sheet glass, ordinary quality and glazing with oil putty in square exceeding 0.5 Sqm in each pane complete all as specified and as directed. |
| 31 | S & F in repairs Stainless steel wire cloth. 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples complete all as specified and directed. |
| 32 | M & L for Preparation of new steel surfaces of any description, over 10 cm in width or girth, not otherwise described and applying two coats of synthetic enamel paint over a coat of red oxide, zine chrome primer complete all as specified and directed. |
| 33 | Taking down chowkats or frames, exc 1.5 but n.exc. 4 Sqm in each with shutter (without taking off shutter from the frame) complete all as specified and directed. |
| 34 | S & F 35 mm thick, Flush shutters, solid core construction, with block board core and plywood both face panels, commercial type on both sides complete all as specified and directed. |
| 35 | S & F 100mm long, Butt hinges, medium weight, cold rolled mild steel complete all as specified and directed. |
| 36 | S & F 150 mm size, extruded Aluminium alloy handles, fabricated type, anodised complete all as specified and directed. |
| 37 | S & F 150mm long floor door stopper of aluminium alloy body and tongue, anodised, with hard drawn steel spring, fixed in floor complete all as specified and directed. |
| 38 | S & F 150 mm long, Aluminium anodised, barrel tower bolts of extruded section complete all as specified and directed. |
| 39 | S & F 300 mm Aluminium alloy anodised sliding door bolt with hasp & staple (bolt type) and fixing clipes of sheet, cast or extruded sections and fixing bolts of extruded sections or cast aluminium alloy, length of bolt complete all as specified and directed. |
| 40 | M & L for Preparation of new or previously untreated wood and wood based surfaces of any description, not otherwise described, over 10 cm width or girth and applying two coats of synthetic enamel paint (1st grade quality) over a coat of pink primer complete all as specified and directed. |
| 41 | M & L for cutting holes in brick walls n exc half brick in cement mortar for inserting holdfasts and making good dismantled portion in cement mortar 1:3 or cement concrete 1:2:4 Type B-1 as required complete all as specified and directed. |
| 42 | S & F Steel door including projecting type hinges, steel handle, complete, with glazing bars, dovetailed or welded complete all as specified and directed. |
| 43 | S & F 1mm thick mild steel, plain, black sheet in wall cladding, steel gates and similar work, cut to size, holes punched; including round headed screws, clout nails or rivets and fixed to wood or steel framing with plain 40 mm lap joints with riveted or welded seams, including bending or turning up, mitred angles, etc. as required complete all as specified and directed. |
| 44 | Excavating in post holes (or similar holes) each n. exc 0.5 Cum, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers n. exc 25cm, watering and removing surplus soil to a distance n. exc 50m and making good surface in soft/loose soil complete all as specified and directed. |
| 45 | M & L for hardcore of gauge n.exc 63 mm of broken stone or boulders, deposited, spread and levelled in layers not exceeding 15 cm thick, watered and rammed to a true surface complete all as specified and directed. |
| 46 | M & L for Preparation of old steel surfaces of any description, over 10 cm in width or girth, not otherwise described and applying one coat of synthetic enamel paint complete all as specified and directed. |
| 47 | M & L for Plain cement concrete 1:3:6, type C-2 (using 40 mm graded stone aggregate) as in walls or retaining walls, any thickness, size or shape including pilasters, buttresses columns, pillars, boundary pillars and posts complete all as specified and directed. |
| 48 | S & F Framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165complete all as specified and directed. |
| 49 | S & F 1000 litres capacity rotational moulded polyethylene water storage tanks (Cylindrical vertical with closed top), hoisted and fixed in position including taking down old unserviceable one as specified in SSR Part I and directed. |
| 50 | S & F 20 mm bore, Ball valves high pressure of PTMT with epoxy coated Aluminium rod & high density plastic ball screwed for iron pipe and fixed. (Minimum weight - 210 gms) complete all as specified and directed. |
| 51 | S & F in repairs 20 mm bore, gun metal Gate valves, with iron wheel head, Class-I, Pressure Tested of 1.5 Mpa, screwed both ends for iron pipe complete all as specified and directed. |
| 52 | S & F Mild steel bolts of exc 12mm and n exc 20mm dia of neck purpose made with hexagonal or square head one end and screwed the other, or screwed both ends; each screwed end to be fitted with washers and one hexagonal or square nut. exc 30cm long complete all as specified and directed. |
| 53 | Supply, laying, connection and testing, 20mm bore, cPVC pipes SDR 13.5 pipes & plain cPVC SDR 11 fittings on walls/ceiling or laying in floors, etc and including taking up or down un- serviceable pipes complete all as specified and directed. |
| 54 | Supply, laying, connection and testing, 25mm bore, cPVC pipes SDR 13.5 pipes & plain cPVC SDR 11 fittings on walls/ceiling or laying in floors, etc and including taking up or down un- serviceable pipes complete all as specified and directed. |
| 55 | S&F in repairs sinks with drainage board made of stainless steel 1mm thick kitchen or laboratory with plugs, washers and wastes; including bedding in cement mortar to dwarf wall or including fixing cantilever brackets and connecting union to pipe overall size 915mm x 460mm bowl size 410mm x 330mm x 160mm complete all as specified and directed. |
| 56 | S & F in repairs, 75 mm bore, Cast iron floor trap, with grating including jointing to waste pipe fixed in cement concrete type B-1 (1:2:4) complete all as specified and directed. |
| 57 | S & F in repairs, 15mm bore, bib taps, fancy type, long body with wall flange cast copper alloy, chromium plated with handle, screwed down, screwed for iron pipe or for brass ferrule complete all as specified and directed. |
| 58 | Demolition of reinforced cement concrete in any position not otherwise specifically provided for and removing rubbish complete all as specified and directed. |
| 59 | M & L for Precast reinforced cement concrete 1:2:4, type B-1 (using 20mm graded stone aggregate) as in landing, cover slabs, shelves and similar articles with plain faces and set in CM 1:6 complete all as specified and directed. (Note: Reinforcement shall be measured and paid seperately) |
| 60 | S & F high strength TMT steel bars 10 mm dia., and over cut to length, bend to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips quality complete all as specified and directed. |
| 61 | S & F vitreous China wash basin, size 550 x 400mm, white, flat back, with PVC waste pipe, CP waste coupling, 32mm dia, chain, plug and porcelean stopper & backets including cutting for and pinning in ends of brackets but excluding tap complete all as specified and directed. |
| 62 | S & F 15 mm bore, pillar taps, fancy type, cast copper alloy, chromium plated with capstan heads, screwed down high pressure with or without lettered 'Hot or Cold' with long screwed shanks and fly nuts, screwed for iron pipe complete all as specified and directed. |
| 63 | Excavating over areas, n exc 1.5 m deep and getting out in soft/loose soil complete all as specified and directed. |
| 64 | Excavating over areas, exc 1.5 m but n exc 3.0 m deep and getting out in soft/loose soil complete all as specified and directed. |
| 65 | Excavating over areas, exc 3.0 m but n exc 4.5 m deep and getting out in soft/loose soil complete all as specified and directed. |
| 66 | M & L for Plain cement concrete 1:4:8, type D-2 (using 40 mm graded stone aggregate) as in foundation, filling and mass concrete, etc complete all as specified and directed. |
| 67 | M & L for use & waste formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundations and plinth beams and similar work, vertical or to batter complete all as specified and directed. |
| 68 | M & L for Reinforced Cement Concrete (1:1½:3)) (using 20 mm graded stone aggregate) as in foundations including rafts, footings, beams and mass concrete, etc complete all as specified and directed. (Note:- Reinforcement will be measured and paid seperately) |
| 69 | M & L for use & waste formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including sup- ports, overhangs, etc. also splays between floors and beams, etc complete all as specified and directed. |
| 70 | M & L for Reinforced Cement Concrete (1:1½:3)) (using 20 mm graded stone aggregate) as in Beams, cantilevers, bressummers, lintels over 1.5m span complete all as specified and directed. (Note:- Reinforcement will be measured and paid seperately) |
| 71 | M & L for use & waste formwork to sides of pillars, posts, struts, piers, columns and stanchions complete all as specified and directed. |
| 72 | M & L for Reinforced Cement Concrete (1:1½:3)) (using 20 mm graded stone aggregate) as in Columns, pillars, piers, posts and struts, etc complete all as specified and directed. (Note:- Reinforcement will be measured and paid seperately) |
| 73 | M & L for use & waste formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping) complete all as specified and directed. |
| 74 | M & L for Reinforced Cement Concrete (1:1½:3)) (using 20 mm graded stone aggregate) as in Slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like, etc complete all as specified and directed. (Note:- Reinforcement will be measured and paid seperately) |
| 75 | S & F high strength TMT steel bars 5mm dia and over upto and including 10mm dia in stirrups, spacers and binders., and over cut to length, bend to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips quality complete all as specified and directed. |
| 76 | Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm as in soft/loose soil complete all as specified and directed. |
| 77 | Removing excavated material not exc. 50 m and depositing where directed at a level not exc 1.5 m above the starting point complete all as specified and directed. |
| 78 | S & F 75 mm bore, PVC (SWR), Soil, waste and vent pipes, single socketed in any length with rubber ring joints fixed to walls, etc complete all as specified and directed. |
| 79 | S & F 110 mm bore, PVC (SWR), Soil, waste and vent pipes, single socketed in any length with rubber ring joints fixed to walls, etc complete all as specified and directed. |
| 80 | S & F 110 mm bore, PVC (SWR) bends of any radius complete all as specified and directed. |
| 81 | S & F 75 mm bore, PVC (SWR) vent cowl complete all as specified and directed. |
| 82 | M & L for soakage well of size 2.4mtr dia and 4.5mtr depth including excavation in any type of soil, foundation in PCC 1:3:6, wall of honey comb walling built in CM 1:6 with top ring of M-25 concrete including intercepting chamber and screen chamber made of brick masonary in CM 1:4, RCC cover slab in M-25 and SFRC cover, interconnecting pipes of RCC/DWC complete filled with bricks bats, complete all as specified and directed. |
| 83 | Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc. complete all as specified and directed. |
| 84 | Taking down unserviceable main switches, DBs, bus bars chambers, VTPN etc any capacity including all fittings and fixtures such as MCBs, isolator, etc and removing from site complete all as specified and directed. |
| 85 | M & L for Point wiring for one light/exhaust fan/fan point/call bell controlled by one way switch with two runs of single core 1.5 Sq.mm. (Nominal area) PVC insulated unsheathed multistranded copper conductor cable FRLS (ISI marked) drawn through and including non metallic PVC casing capping (ISI marked) (aprox size 20/25/40mm width) surface type with all fittings/fixtures such as Tee, Bend, elbow, socketr, shaddle etc including 1.5mm thick MS sunken/terminal box including 3mm thick backelite sheet cover for fixing flush type switches, sockets, regulators etc. including provision of multistranded 1.5 Sq.mm copper conductor cable FRLS [ISI marked] as earth wire connected to common earth dolly and earth in distribution board complete all as specified and as directed.(Note.: (i) The rate quoted is deemed to include making good the disturbed sufaces and to match the adjoining surface.) |
| 86 | All as per item No. 85 above but for One 3/5 pin socket outlet 6 amps point on same board complete ditto |
| 87 | All as per item No. 85 above but for One 3/5 pin socket outlet 6 amps on independent board complete ditto |
| 88 | All as per item No. 85 here in before but for one 15 Amps power point on the independent board with two runs of PVC insulated and unsheathed copper conductor cable of size 2.5 sqmm multistranded FRLS (ISI marked) and 2.5 sqmm PVC insulated unsheathed solid copper conductor cable FRLS (ISI marked) as earth lead complete ditto |
| 89 | S & F switch piano Flush type, single pole one way 6 Amp 240 volts, complete all as specified and as directed. |
| 90 | S & F Socket outlet 2 in 1, 3 pin, 5 Amps, flush type complete all as specified and as directed. |
| 91 | S & F Switch socket combination 2 in 1, 3 pin, 6 Amp, flush type, universal complete all as specified and as directed. |
| 92 | S & F Switch socket combination 2 in1, 3 pin, 6 and 16Amp, flush type, universal complete all as specified and as directed. |
| 93 | S & F Stepped type electonic fan regulator flush type on the existing phenolic laminated sheet complete all as specified and as directed. |
| 94 | S & F ceiling rose, 65 X 50mm two to three terminals, PVC/polycarbonate, insolated body complete all as specified and directed. |
| 95 | S & F LED tube light fittings, retro bar professional WH 5700K to 6000K, 20 Watt and 2000 Lumens of cool white with all accessories, internally prewired and connecting up with twin core twisted copper conductor cable of suitable size including tube lamp complete all as specified and directed. |
| 96 | S & F LED Bulk Head, 10 Watt, IP 65 rated, compact design, PC Co extruded with high energy saving with all accessories and connecting up including lamp complete all as specified and directed. |
| 97 | S & F 2ftx2ft recessed mounting, LED panel light fittings, 40 Watt with all accessories, internally prewired and connecting up with twin core twisted copper conductor cable of suitable size including tube lamp complete all as specified and directed. |
| 98 | S & F in repair 35 Watt, 230 Volts AC New generation energy saving and environmental friendly long life LED building security light made up of pressure die cast aluminium housing with high efficiency LED as lighting source and lens embedded PC cover having Bottom Opening seperate driver compartment with IP66 protection and impact resistance of IK08 with lamp, fixing accessories and connecting up with suitable copper conductor complete all as specified and directed. |
| 99 | S & F Lamp Holder, PVC/ Polycarbonate type with backplate suitable for batten fitting and including LED Bulb, 15 Watts, B-22 Lumen ≥ 900, Luminous afficacy ≥ 100 Lum/Watt, CCT:WW/NW/CW, CRI > 80 Ra, IP 20 rated, overmoulded plastic housing, polycarbonate diffuser, 4KV surge Protection with over voltage protection withstand upto 440 V (for 10 Minute) with open and short circuit protections as per IS: 16102 complete all as specified and directed. Please Enable Macros to View BoQ information |
| 100 | S & F Lamp Holder, PVC/ Polycarbonate type with backplate suitable for batten fitting and including LED Bulb, 15 Watts, B-22 Lumen ≥ 900, Luminous afficacy ≥ 100 Lum/Watt, CCT:WW/NW/CW, CRI > 80 Ra, IP 20 rated, overmoulded plastic housing, polycarbonate diffuser, 4KV surge Protection with over voltage protection withstand upto 440 V (for 10 Minute) with open and short circuit protections as per IS: 16102 complete all as specified and directed. Please Enable Macros to View BoQ information |