| 1 | S&F 2nd class HW scantlings, clean sawn supplied and fixed, with and including dismantling existing u/s timber scantling framed work 40sq.cm and over section, in any position, complete all as specified and as directed. |
| 2 | Taking down & refixing in old or new position of 2nd class HW scantlings, clean sawn, with and including dismantling existing u/s timber scantling framed work 40sq.cm and over section, in any position, complete all as specified and as directed. |
| 3 | M&L for Preparing surface of wood and wood based materials, new or old, of any description and girth and treated with two coats of creosote oil, complete all as specified and as directed. |
| 4 | S&F Pre painted galvalume aluminium zink coating GI based corrugated steel sheet 0.45mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws and washers, with and including dismantling plain or corrugated AC sheeting, any gauge, thickness in roof coverings, complete all as specified and as directed. |
| 5 | S&F Rolled mild steel roof trusses (framed) trussed purlins, rafters, struts (beam, tee, angle, channel, hollow sections or flat sections) including distance pieces & cleats, conforming tograde Fe 410-W Gde E-250 quality 'B', complete all as specified and as directed. |
| 6 | S&F Mild steel framed work such as grills, gratings etc., with ends of bars shouldered and/or riveted or forget into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; frame work of water tanks and similar work conforming to Fe-290 Gde- E-165, with and including dismantling existing wrought iron or mild steel work of any description, complete all as specified and as directed. |
| 7 | M&L for Cement concrete roofing tiles, rustic red colour, 420mm x 330mm size of 230 kg minimum breaking strength, double groove design, as in roofing, interlocking at side joints, laid dry as in roofing, complete all as specified and as directed. Make: Model INDOGRACE of ETERNA or Equivalent make as specified here in after. |
| 8 | M&L for Cement concrete Rusted Red/Grey colour Ridge cap of size 360mmx207mm x 240mm, with and including 15mm thick in roofing bedded and jointed in cement mortar 1:6, complete all as specified and as directed. Make: Model INDOGRACE of ETERNA or Equivalent make as specified here in after. |
| 9 | S&F Pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick (TFT) of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws, with and including taking down existing u/s AC sheet roof of any description, complete all as specified and as directed. |
| 10 | M&L for PCC type C0 [1:3:6] using 12.50mm graded stone aggregate) as in copings, bed plates, water troughs and the like including weathering, slightly rounded or chamfered angles and throating, finished plain fair faces, including demolition of old cement concrete of any type, complete all as specified and as directed. |
| 11 | S&F Aluminium Composite Pannel board of 4mm thick, comprising of a core containing not less than 70% non combustible mineral filling, sandwiched between two skins of 0.50mm thick aluminium alloy PERALUMAN-100 of weight not less than 7.6kg/Sqm, with all sub structures, anchors, hardware and all fittings, fixed over and including aluminium section of size 35x25x2mm and 1.0m x 0.30m panel with and including necessary frame work, screwing & scaffolding, fixed with screws / nails, with and including dismantling existing u/s boarding of any description, complete all as specified. Note: Measurements shall be taken as flat as fixed without any allowance for laps. |
| 12 | M&L for Preparation of new steel surfaces of any description over 10cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer, complete all as specified and as directed. |
| 13 | M&L for False ceiling with High Pressure Steam Cured (HPSC) 4mm thick Non Asbestos Fibre Cement ceiling boards fixed with and including supply & fixing powder coated aluminium snap grid of size 605mmx605mm consisting of 25X25X1.25mm aluminium angles and TEEs of size 35x25x1.25mm with galvanised wire of required length and 6mm dia hanger grid suspended from trusses/ ceiling and purlins not exceeding 1200mm c/c both ways, with and including applying three coats of white wash on ceiling surface, with and including taking down existing u/s ceiling with frame work of any description, complete all as specified and as directed. |
| 14 | M&L for Pre-cast cement concrete solid block masonary type C1, 1:3:6 (using 20 mm graded stone aggregate) exc 10 cm width and setting in CM 1:6, with and including demolition of existing brick work of any description, complete all as specified and as directed. |
| 15 | M&L for 10mm thick Rendering on fair faces of brick work or concrete surfaces in cement mortar 1:6 and finish the surface even and smooth without using extra cement, complete all as specified and as directed. |
| 16 | M&L for 15mm thick Rendering on fair faces of brick work or concrete surfaces in two layers as 10mm thick in cement mortar 1:6 followed by 5mm thick in cement mortar 1:4 mixed with and including water proofing compound @3% of weight of cement and finish the surface even and smooth without using extra cement, with and including taking down existing cement plaster of any description, complete all as specified and as directed. |
| 17 | M&L for preparation of newly plastered surfaces of wall and applying two coats of oil bound distemper over a coat of alkali resistant primer with and including a layer of wall care putty, complete all as specified and as directed. |
| 18 | M&L for applying Two coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm with and including preparation of new plastered surfaces of any description, all as per manufacturer's instructions, complete all as specified and as directed. |
| 19 | M&L for complete removal of existing treatment on old walls with wire brush, scrapping down smoke soot, mould, moss nad efforescent salts, oils & greasy spots etc., and two coats of oil bound distemper over a coat of alkali resistant primer with and including a layer of wall care putty and including preparation of old surfaces of any description, complete all as specified and as directed. |
| 20 | M&L for complete removal of existing treatment on old walls with wire brush, scrapping down smoke soot, mould, moss nad efforescent salts, oils & greasy spots etc., and applying two coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm with and including preparation of old surfaces of any description, complete all as specified and as directed. |
| 21 | M&L for Light Shade Coloured Vitrified Ceramic tiles 08mm to 10mm thick (square/rectangular) area of each tile exc. 0.18 Sq.m. but n. exc. 0.36 Sq.m, as in floors etc., laid over and including 15mm thick screed bed or bedding layer in CM (1:4), set and jointed in neat cement slurry and pointed in coloured cement to match, with and including demolition of existing floor tiles of any type with bedding mortar, complete all as specified and directed. |
| 22 | M&L for Light Shade Coloured Vitrified Ceramic tiles 08mm to 10mm thick (square/rectangular) area of each tile exc. 0.18 Sq.m. but n. exc. 0.36 Sq.m, as in skirting etc., laid over and including 10mm thick backing layer in CM (1:3), set and jointed in neat cement slurry and pointed in coloured cement to match, with and including demolition of existing tiles of any type with bedding mortar, complete all as specified and directed. |
| 23 | S&F Machine cut Granite (of any type) (table rounded and polished) 20mm thick, as in flooring, steps, jambs, cills, cooking platforms and the like, laid over and including 20mm thick screed bed or bedding layer in CM 1:3 and jointed with grey cement slurry mixed with pigment to match the shade of the slab, rubbing and polishing, with and including demolition of existing floor, complete all as specifed and as directed. |
| 24 | M&L for Machine cut Kota stone slab 18-20mm thick, as in flooring over with and including 20mm thick cement screed in CM 1:6, laid and jointed with grey cement slurry mixed with pigment to match shade of the slab, including cutting, waste, grinding, rubbing and polishing, with and including demolition of existing floor tiles of any description, complete all as specified. |
| 25 | S&F Machine cut kota stone slab 18-20mm thick, as in vertical surfaces such as skirting/dado, laid over and including 15mm thick backing coat in CM 1:3 and jointed with grey cement slurry mixed with pigment to match the shade of the slab, rubbing and polishing, with and including demolition of existing skirting/dado, complete all as specifed and as directed. |
| 26 | M&L for 75mm thick plain cement concrete 1:3:6 type C1 (using 20mm graded hard granite stone aggregate) as in plinth protection, finished even and fair without using extra cement including making construction joints in 3 mtres interval and joint filled with sealing compound, with and including demolition of cement concrete (un-reinforced) as in ground floor, complete all as specified and as directed. |
| 27 | M&L for Premium quality, joint free coloured Non skid ceramic tiles 7mm to 8mm thick (square/rectangular) area of each tile exceeding 0.11Sqm but not exceeding 0.36Sqm, as in floors etc., laid over and including 15mm thick screed bed or bedding layer in CM (1:4), set and jointed in neat cement slurry and pointed in coloured cement to match, with and including demolition of existing floor tiles of any type with bedding mortar, complete all as specified and directed. |
| 28 | M&L for Premium quality, joint free ceramic glazed coloured wall tiles of 7 to 8mm thick (square / rectangular) area of each tile not exceeding 0.18Sqm, on vertical surfaces such as dado and the like, set and jointed in neat cement slurry and pointed in coloured cement to match, laid over & including 10mm thick rendering in CM 1:3 and including taking down existing dado/skirting with backing mortar, complete all as specified. |
| 29 | S&F IN REPAIR PVC Wall lining with 5mm thick wood grain printed PVC sheet fixed with solvent cement on existing surfaces of any description, complete all as specified and as directed. |
| 30 | S&F IN REPAIR PVC Sheet fillet with 5mm thick wood grain printed PVC sheet of 35mm width, fixed with solvent cement on existing surfaces of any description, complete all as specified and as directed. |
| 31 | S&F Machine cut Granite (Z Black) 20mm thick as in partitions, bedded and jointed with grey cement slurry mixed with pigment to match the shade of the slab, rubbing and polishing on both sides and chamfering / bull nosing on exposed faces, complete all as specified and as directed. |
| 32 | S&F 18mm thick block boards, grade 1 quality, exterior grade, commercial type, fixed with and including 1.5mm thick decorative laminate sheet of type 1 as surface finish of approved colour, with and including 6mm teak wood lipping on edges, fixed with fevicol gum, nails, screws to cub board shelves / cabinets etc., complete all specified. |
| 33 | S&F IN REPAIR Stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40 mm fixed with tinned tack or stainless wire staples, complete all as specified and as directed. |
| 34 | M&L for 5.50mm thick sheet glass ordinary quality and glazing with oil putty in squares not exc 0.5 Sqm in each pane, with and including hacking out old broken glass (any thickness/size, quality or description) from wooden frames, glazed with putty or fixed with beads, complete all as specified and as directed. |
| 35 | S&F CPVC pipe of 20mm bore of pipe of SDR 11 with plain CPVC SDR fittings with including fittings (such as bends, tees, short pieces connectors, elbows, reducers, unions, sockets etc) and fixed to walls / ceilings / laid in floors, including testing, with and including taking down existing u/s GI pipe, complete all as specified and as directed. |
| 36 | S&F CPVC pipe of 25mm bore of pipe of SDR 11 with plain CPVC SDR fittings with including fittings (such as bends, tees, short pieces connectors, elbows, reducers, unions, sockets etc) and fixed to walls / ceilings / laid in floors, including testing, with and including taking down existing u/s GI pipe, complete all as specified and as directed. |
| 37 | S&F IN REPAIR 15mm dia Bib tap, cast copper alloy Fancy type CP brass long body, screwed down, screwed for iron pipe or for brass ferrule and fixed complete all as specified and as directed. |
| 38 | S&F IN REPAIR PVC Flexible pipe (waste pipe) 32mm bore dia, minimum 900mm long, suitable for 32mm bore waste coupling of sink, WHB, etc., complete all as specified. |
| 39 | S&F uPVC (SWR) eaves gutter 150mm dia trapezoidal shape Gde-I fixed with and including mild steel flat iron clamps of suitable size, complete all as specified and as directed. |
| 40 | S&F IN REPAIR 110mm bore uPVC (SWR) soil, waste and vent pipe, single socketed in any length with rubber ring joints, fixed to wall with brackets, complete all as specified and as directed. |
| 41 | S&F Mild Steel Corrugated Galvanised Steel Sheet 0.45mm thick of class 8, grade of zinc coating 275, as in roof covering with two corrugation side laps fixed with coach screws & washers, with and including dismantling u/s AC sheet roofing and removing rubbish off the premises, complete all as specified and as directed. |
| 42 | M&L for Mild steel Wind Tie bars with screwed ends, nuts, washers and mild steel plates for walls, chimneys, roofs, arches, etc. king rods and straining bolts conforming to Fe 290 Gde-E-165, with and including distantling existing steel work of any description, complete all as specified and as directed. |
| 43 | S&F uPVC (SWR) bend any radius with access door, suitable for 110mm bore pipes, including jointing with solvent, complete all as specified and as directed. |
| 44 | S&F Turbine ventilator of 900mm throat dia, light weight, aluminium alloy body, wind driven, suitable for 125kmph wind speed with special rubberized hardware to prevent heavy ingress, fixed and fitted in roof sheet in vertical installation, complete all as specified. |
| 45 | M&L for Mirror Polishing using diamond grinding pads on existing Kota stone flooring of any description, polished up to high gloss finish as approved, with and including deep cleaning, removing scratches with abrasive materials (like emery or rubbing stones), followed by grinding with progressively finer diamond pads etc., complete all as specified and as directed. |
| 46 | M&L for Point wiring with 1.5 Sq.mm FRLSH PVC insulated unsheathed copper conductor cable, single core multi stranded 1100Volt grade conforming to IS 694: 1977, drawn in and and including concealed rigid PVC conduit 20mm size, ISI marked, with accessories, junction boxes, tees, terminal boxes, factory made modular metal boxes with modular top cover plates with frame for modular switches / sockets etc., including one run of 1.5 Sq.mm single core FRLS PVC unsheathed copper conductor cable as earth continuity conductor and connected to common earth dolly, for one light / fan /bell point controlled by one way switch, including taking down old u/s point wiring of any type with fittings, complete all as specified and as directed. Note: Cutting chases and making good surfaces shall be included in the unit rate. |
| 47 | All as per Serial Item No. 46 here-in-before but for 3 pin 5/6Amp switch socket point, on same board, complete all as specified. |
| 48 | All as per Serial Item No. 46 here-in-before but for 3 pin 5/6Amp switch socket point, on independent board, complete all as specified. |
| 49 | All as per Serial Item No. 46 here-in-before but with 2.5Sqmm copper conductor cable and 2.5 Sqmm cable as earth continuity conductor for 3 pin 6/16Amp switch socket point, on independent board, complete all as specified. |
| 50 | S&F Modular switch 1 way 5/6Amp, 1 Module, 240 Volts, complete all as specified and as directed. |
| 51 | S&F Modular Socket, 5/6A, 2/3 pin combined , 2 module, 240 Volts, complete all as specified and as directed. |
| 52 | S&F Modular switch 1 way 15/16A, 1 Module, 240 Volts, complete all as specified and as directed. |
| 53 | S&F Modular Socket, 6A/16A, 2/3 pin combined multipurpose, 2 module, 240 Volts, complete all as specified and as directed. |
| 54 | S&F Modular BLDC Fan regulator, 240Volt, 120 wwatt, electronic step type, 2 Module, for ceiling fan of any sweep, complete all as specified. |
| 55 | S&F Modular Bell push, 5Amp, 230Volt, 1 Module and S&F Ding Dong type Calling Bell, 230Volt, AC, complete all as specified. |
| 56 | S&F Ceiling rose, 3 terminals PVC/Polycarbonate, isolated body, complete all as specified and as directed. |
| 57 | S&F IN REPAIR Professional LED Luminaries 1x40Watt, surface mounting decorative / suspended type, aluminium extruded LED Batten with ABS end cap, 220V, AC, PC Co-extruded IP65, suitable for on grid / wall surface, with and including high efficiency LEDs minimum 120lum/watt in warm white / natural white, pre-wired and connecting up with three core flexible copper conductor, complete all as specified and directed. |
| 58 | S&F IN REPAIR Professional LED luminaires 600mm x 600mm, 35/36 watt, 220Volt, with and including high efficiency LEDs minimum 120lum/watt in warm white / natural white, PF>0.95, AC recessed / surface type with high efficiency PMMA diffuser soft glare free light, complete with driver with and including connecting up with three core flexible copper conductor cable of suitable size, complete all as specified. |
| 59 | S&F IN REPAIR LED Professional Luminaries fitting (WW / CW / NW)12watt, 220Volt, recessed mounted pressure die-cast with aluminium luminaries in powder coated white finish in round profile with optimised heat sink for efficient heat dissipation and separate replaceable electronic driver & high efficiency LEDs suitable for ceiling fitting with and including all accessories, pre-wired and connecting up with three core flexible copper conductor cable of suitable size, complete all as specified. |
| 60 | S & F Wall light (for living room/bedroom/Dinning Hall) B22 base incl 9 watt LED Bulb (WW), complete all as specified and directed. |
| 61 | S&F Electric water heater, storage type, ABS body with SS inner tank and heating copper element upto 2 KW, capacity 25 litre, BEE 5 Star rated complete with all accessories such as safety valve, thermostat, NRV, connection pieces and along with inlet & outlet hot water connecting pipes, with and including taking down existing u/s water heater and depositing to AGE E/M Store yard, complete all as specified and as directed. |
| 62 | S&F Galvanised steel water tubing 40mm bore dia, medium grade, conforming to IS:1239 (Part I) with and including all fittings (such as bends, tees, short pieces connectors, elbows, reducers, unions, sockets etc) and laid under trench / floors and including testing, complete all as specified and as directed. |
| 63 | S&F Galvanised steel water tubing 25mm bore dia, medium grade, conforming to IS:1239 (Part I) with and including all fittings (such as bends, tees, short pieces connectors, elbows, reducers, unions, sockets etc) and laid under trench / floors and including testing, complete all as specified and as directed. |
| 64 | S&F IN REPAIR LED Building Security light fitting 35/36Watts, 230 volts, die cast aluminium housing, not less than 120lum/W, with suitable size GI bracket made out of 32mm GI light grade pipe fixed with clamps, nuts&bolts etc., with IP 65/66 protection with driver, bracket with impact, corrosion resistant and all accessories, complete all as specified and as directed. |
| 65 | S&F IN REPAIR LED Post Top lantern luminaires 40watt (warm white), 220Volt, not less than 120lum/W, PF>0.95, AC, outdoor type with decorative post top for 360 degree indicator light , IP 65 Protection, with impact & corrosion resistant with electronic driver & high brightness LEDs and connecting up with three core flexible copper conductor cable of suitable size, complete all as specified. |
| 66 | S&F IN REPAIR 25mm dia, Gun-metal gate valve confirming to IS 9338, with iron wheel head, screwed both ends for iron pipe, complete all as specified and as directed. |
| 67 | S&F Ceiling fan 30/35Watts with copper coil complete with blades, down rod, 3 blade type, with and including all accessories, 230Volt, 1200mm sweep, minimum air delivery 210 CFM with service value 6.0BEE, with brushless direct current motor (BLDC), five star rating, and connecting up with three core flexible copper conductor cable of suitable size, including taking down existing u/s ceiling fan and depositing to AGE E/M Store yard, complete all as specified and as directed. |
| 68 | S&F Rotational moulded polyethylene water storage tank (cylindrical vertical with closed top), ISI Marked, three layered, 2000 Litres capacity, hoisted and fixed in position all as specified in SSR Part I, with and including 25mm dia PTMT ball valve, with and including taking down existing u/s water tank of any description, complete all as specified. |
| 69 | S&F IN REPAIR Factory made epoxy powder coated Sheet metal enclosure Vertical TPN DB, 4 ways (VTPN MCB DB)with IP 43 protection, double door, sheet steel phosphetised powder painted with 200 amps rated copper busbar 415Volt, fixed with 1.5 Sq. mm copper PVC sheathed cable for earth continuity and suitable for having MCCB’s/MCBs, complete all as specified and as directed. |
| 70 | S&F IN REPAIR MCCB, 4pole, 125 Amps, 415Volts, thermal magnetic, Ics=100% Icu, 16kA current rating conforming to IEC-60947-II along with spreader incl Phase Barreir to be fixed in distribution board, complete all as specified. |
| 71 | S&F IN REPAIR MCB SPN 40Amp, 10kA, 230Volt, B curve with necessary connecting up in MCB DB, testing and commissioning, complete all as specified and as directed. |
| 72 | S&F IN REPAIR MCB SP 16 to 32Amp, 10kA, 230Volt, B curve with necessary connecting up in MCB DB, testing and commissioning, complete all as specified and as directed. |
| 73 | S&F IN REPAIR, Factory made epoxy powder coated sheet metal enclosure for DBs (Fixed flush to the wall), SPN, 230volt, 12Way, double door, IP-42 protection with 200 Amp rated copper bus bar 230Volt, and 1.5 Sq. mm copper PVC sheathed cable for earth continuity and suitable for having MCB’s, complete all as specified. |
| 74 | M&L for Circuit / Sub main wiring with Two runs of 6.0Sqmm PVC FRLSH insulated copper conductor cable, single core multi stranded 1100Volt along with one run of 6.0Sqmm as earth wire, drawn through and including rigid concealed PVC conduit of 25mm size with accessories, including taking down old submain wiring of any type, complete all as specified and as directed. Note: Two runs of cable, one run of earth wire and one run of conduit shall be measured as one unit. |
| 75 | S&F IN REPAIR MCB SP 40Amp, 10kA, 230Volt, 'C' curve with necessary connecting up in MCB DB, testing and commissioning, complete all as specified and as directed. |
| 76 | Excavation in trenches not exceeding 1.5m wide and not exceeding 1.5m deep in any type of soil, for foundation etc., or for laying of cable/ GI Pipe, shafts, wells, cesspits, manholes, pier holes, etc., complete all as specified. |
| 77 | Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25cm thick of excavated soil, as in any type of soil, complete all as specified. Note: A deduction of 10% shall be made from total computed volume of filling to cater in bulk irrespective of machinery used for ramming. |
| 78 | Removal of excavated material [Soil] to a distance not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point, complete all as specified. |
| 79 | M&L for Double wall corrugated high density polymer (SDR 17) of ISI marked 50mm outer dia and 40mm inner dia including necessary fittings like couplers, bends, end caps etc., with ISI marked (IS 14930- 2001 ), laid in trenches / floors & fixed on wall/ pole with and including necessary fittings such as bends, sockets & other connected accessories etc for laying of electric cables / road crossings etc., complete all as specified and as directed. |
| 80 | Supply, laying, testing and commissioning of LT XLPE insulated, screened with extruded PVC inner sheathed, PVC bedded, galvanised steel strip armoured electric FR power cable [heavy duty] of size 4.0core x 25.0Sqmm, with stranded aluminium conductor, 1100 volts grade, suitable for earthed system with and including cable glands, ferrules and connected accessories, laid in trenches or ducts or through the pipe etc., including taking down old u/s cable, complete all as specified. Note: Necessary excavation & earth work & cable protection pipe shall be measured and paid separately under respective items. |
| 81 | M&L Mild steel Framed work such as grills, gratings, rungs etc. with ends of bars, shouldered and/or riveted, or forged into spikes, framed guard bars, water tank staging, barred iron doors, ladder, framed baluster, walk ways, railings, and similar work confirming to Fe-290, Gde E-165, complete all as specified and as directed. |
| 82 | M&L for IN REPAIR Earthing complete with galvanised steel earth plate electrode 60cm X 60cm X 6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to galvanised earth lead 4mm GI wire by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No.3 of SSR Part-I, including excavation / earth work in any strata, adequate quantity of charcoal and common salt, PCC chamber with RCC 1:2:4 type B1 40mm thick cover slab with 8mm dia TMT bars @150mm c/c in bothways, suitable handle and angle iron frame of suitable size to fix the cover, with 20mm bore GI pipe light grade for watering with funnel, wire mesh and 15mm bore GI pipe medium grade for GI wire protection and 4mm GI earth wire, including testing after completion, complete all as specified and directed. Note : Earth wire will be measured after 7.5mtr from the earth strip or earth testing terminal block whichever is lesser under relevant item. Please Enable Macros to View BoQ information |