| 1 | S.I.T.C of UPVC hard Drain Pipe Make: Ploypack, AKG, Dplast. |
| 2 | Supply and erection of Power unit with 25Amp. MCB and 16 Amp. Plug along with surface box, 3 pin top etc. made of fire retardant material plastic along with cover plate (modular type) 3M to be installed on surface/recess upto entire satisfaction of Engineer-in-charge of the work. |
| 3 | `S/I/T/C of 5 KVA voltage stabilizer copper wound with 170 upto 270. Suitable for operation on 230V, Hz-10% 50Hz 1 phase AC supply Make Blue bird/V-guard/Blue guard` |
| 4 | S.I.T.C of 60X60 mm PVC batten Heavy duty (in spl. White color) with clamping. |
| 5 | S.I.T.C of flexible pipe 2` white heavy duty. |
| 6 | S/F of hinging type MS stand (Platform frame made out angle iron along with vibration pad, Threaded rod (Sariya) and fasteners.) MS stand platform will be painted with one coat primer and two coat of epoxy paint. |
| 7 | S.IT.C of 4 Core 2.5sqmm copper wire ISI mark Make Plaza / Havells / Polycab / R.R. Kabel / KEI |
| 8 | HI WALL SPLIT SYSTEMSSupply , Installation, Testing and Commissioning of Air Cooled Hi Wall split type Air conditioners complete with Indoor unit(IDU), Out door unit (ODU), surface / concealed copper Refrigerant piping with insulation (closed cell elastomeric nitrile rubber tubular pipe section) upto 3 Mtr (IDU to ODU), copper power cable upto 3.5 Mtr (IDU to ODU) i/c drain pipe R-32/R-410/ R407 Green Refrigerant, wireless Remote control, suitable for working between 180-260V with low and high voltage cutoff and 50 hz ,1 phase AC supply capable of performing cooling, dehumidification, air circulation of following capacity with Scroll / rotary compressor. The system shall be able to deliver 100% of the rated capacity upto 42 Degree Celsius. Min 5 year Original Equipment Manufacturer (OEM) warranty both compressor and Printed Circuit Board (PCB). Must comply : Electrical cable IS 694 or IS 9968 temperature sensing control IS /International Electro technical Commission (IEC) 60730, hermetic compressor IS 10617, heat exchanger IS 11329, capacitor IS 2993 and motor IS 12615. Complete as per CPWD specification and IS : 1391 Part II 2023. The system shall be able to operate up to 50 0C (out door ambient temperature).Inverter Type - Cooling only2.0 TR with 5 Star BEE Rating (New HSR 25.17.2.4) |
| 9 | COPPER REFRIGERANT PIPINGSupplying, Installation, testing and commissioning including vaccumiazation and Nitrogen testing of following nominal sizes of soft/hard drawn copper refrigerant piping for VRV/VRF system, complete with fittings, with suitableadjustable ring type hanger supports, jointing/brazing including accessories, insulated with XPLE Class-O tubular insulation/with Class-O closed cell elastometric nitrile rubber tubular sleeves sections of 19 mm thick insulation as given below for Suction and Liquid lines, all accessories as per specifications etc. as required15.86 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm (New HSR 23.35.14.4) |
| 10 | COPPER REFRIGERANT PIPINGSupplying, Installation, testing and commissioning including vaccumiazation and Nitrogen testing of following nominal sizes of soft/hard drawn copper refrigerant piping for VRV/VRF system, complete with fittings, with suitableadjustable ring type hanger supports, jointing/brazing including accessories, insulated with XPLE Class-O tubular insulation/with Class-O closed cell elastometric nitrile rubber tubular sleeves sections of 19 mm thick insulation as given below for Suction and Liquid lines, all accessories as per specifications etc. as required6.4 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm (New HSR 23.35.14.1) Please Enable Macros to View BoQ information |