| 1 | Total amount of Sch 'A' Sec-I ( TOILET BUILDING WORKS) Lump sum price worked out by the contractor for \\" TOILET BUILDING WORKS \\" as listed in schedule 'A' Part-I |
| 2 | Total amount of Sch 'A' Sec-II (DEMOLATION WORKS) Lump sum price worked out by the contractor for \\" DEMOLATION WORKS \\" as listed in schedule 'A' Part-II |
| 3 | Total amount of Sch 'A' Sec-III (SITE CLEARANCE, DEVELOPMENT, EARTH WORKS AND EXCAVATION WORKS) Lump sum price worked out by the contractor for \\" SITE CLEARANCE, DEVELOPMENT, EARTH WORKS AND EXCAVATION WORKS \\" as listed in schedule 'A' Part-III |
| 4 | Total amount of Sch 'A' Sec-IV (INTERNAL WATER SUPPLY WORKS ) Lump sum price worked out by the contractor for \\"INTERNAL WATER SUPPLY WORKS \\" as listed in schedule 'A' Part-IV |
| 5 | Total amount of Sch 'A' Sec-V (INTERNAL ELECTRIFICATION WORKS) Lump sum price worked out by the contractor for \\"INTERNAL ELECTRIFICATION WORKS \\" as listed in schedule 'A' Part-V |
| 6 | Total amount of Sch 'A' Sec-VI (SUMMER APPLIANCES, AIR CONDITIONING AND REFRIGERATOR WORKS) Lump sum price worked out by the contractor for \\" SUMMER APPLIANCES, AIR CONDITIONING AND REFRIGERATOR WORKS \\" as listed in schedule 'A' Part-VI |
| 7 | Total amount of Sch 'A' Sec-VII ( ROAD, PATH, CULVERTS AND HARDSTANDING WORKS ) Lump sum price worked out by the contractor for \\" ROAD, PATH, CULVERTS AND HARDSTANDING WORKS \\" as listed in schedule 'A' Part-VII |
| 8 | Total amount of Sch 'A' Sec-VIII (EXTERNAL WATER SUPPLY WORKS ) Lump sum price worked out by the contractor for \\"EXTERNAL WATER SUPPLY WORKS \\" as listed in schedule 'A' Part-VIII |
| 9 | Total amount of Sch 'A' Sec-IX (EXTERNAL ELECTRIC SUPPLY & LIGHTENING PROTECTION WORKS) Lump sum price worked out by the contractor for \\"EXTERNAL ELECTRIC SUPPLY & LIGHTENING PROTECTION WORKS \\" as listed in schedule 'A' Part-IX |
| 10 | Total amount of Sch 'A' Sec-X (SEWAGE DISPOSAL WORKS ) Lump sum price worked out by the contractor for \\" SEWAGE DISPOSAL WORKS \\" as listed in schedule 'A' Part-X |
| 11 | Total amount of Sch 'A' Sec-XI ( AREA DRAINAGE WORKS ) Lump sum price worked out by the contractor for \\"AREA DRAINAGE WORKS \\" as listed in schedule 'A' Part-XI |
| 12 | Total amount of Sch 'A' Sec-XII (WALL,FENCING & GATE WORKS ) Lump sum price worked out by the contractor for \\"WALL,FENCING & GATE WORKS \\" as listed in schedule 'A' Part-XII |
| 13 | Total amount of Sch 'A' Sec-XIII (FIRE FIGHTING WORKS) Lump sum price worked out by the contractor for \\" FIRE FIGHTING WORKS \\" as listed in schedule 'A' Part-XIII |
| 14 | Total amount of Sch 'A' Sec-XIV (RAIN WATER HARWESTING WORKS) Lump sum price worked out by the contractor for \\" RAIN WATER HARWESTING WORKS \\" as listed in schedule 'A' Part-XIV |
| 15 | Total amount of Sch 'A' Sec-XV (ARBORICULTURE WORKS) Lump sum price worked out by the contractor for \\" ARBORICULTURE WORKS \\" as listed in schedule 'A' Part-XV |
| 16 | Schedule 'A'Section-XVI (Misc Items of Works) Note : This schedule is not pre-priced by MES and the pre-priced rate indicated as \\"Rs 0.00\\" under Col. 6 siginifies this fact only. |
| 17 | S&F 15mm bore fncy type Tall body/Swan Neck Pillar taps, cast copper alloy, chromium plated, screwed down high pressure, with or without lettered 'HOT or Cold with long screwed shanks and fly nuts, screwed for iron pipe and fixed complete all as specified and directed. |
| 18 | S & F for Punched Tape Concertina Coil 750 mm dia, 300mm pitch with wire dia of 2.6mm as shown in CE CHZ Zone STD-1422(STR) Sheet No 1/4 to 4/4 and conforming to relevant IS all as per specified and directed by Engr in charge |
| 19 | Road safty Convex Mirror 80cm dia made out of pc material provided with suitable MS pipe post duly powder coated, as per site requirement, complete all as specified and as directed by Engr-in-charge. |
| 20 | Road safty Convex Mirror 80cm dia made out of pc material provided with suitable MS pipe post duly powder coated, as per site requirement, complete all as specified and as directed by Engr-in-charge. |
| 21 | Taking down looking mirror of any size in any location including all assessirories |
| 22 | Taking down Aluminium partition of any size and any description including all assessirories |
| 23 | Supply and fixing socket outlet for Tele modular type ISI marked with valid CML No. complete all as specified. |
| 24 | Supply and fixing socket outlet for LAN computer jack modular type ISI marked with valid CML No. complete all as specified. |
| 25 | Supply and fixing socket outlet for TV modular type ISI marked with valid CML No. complete all as specified. |
| 26 | S & F powder coated GI Race Way Cable Tray of size 100 mm x 50mm x 2mm(1 Compartments) incl suitable bracket ,nut, bolt washers, fixed to wall roof etc, complete all as directed |
| 27 | S&F LED bulb 12 Watt, 230 volts AC 50 Hz Retrofit B22 base complete all as specified and directed. |
| 28 | Supply and fix Telephone socket complete all as specified and as directed. |
| 29 | Supply and fix TV socket complete all as specified and as directed. |
| 30 | Supply and fix lan socket complete all as specified and as directed. |
| 31 | M&L for concealed / wall mounted busbar chamber, 4 pole, double door, 415 volts suitable for fixing of 4 pole MCCB upto 160 Amps as incommer and incl 04 Nos of standard insulated bus bar of capacity 200 Amps all enclosed in standard sheet flush mounting type, drilling holes for incoming and out going cables complete with IP-54 all as specified and directed. |
| 32 | S&F offload/manual change over switch in separate sheet steel enclosure of capacity 100 Amps, 4 pole, 415 volts including fixing on wall alongwith electric connection complete all as directed. |
| 33 | S&F Arc Fault Detection Device (AFDD) 63A, rated voltage 240AC, 50 Hz frequency, residual operating current 100mA, Short circuit capacity 10kA, Type A, residual making and breaking capacity 500A, Electrical/Mechanical Endurance 10000 operations (made in India), Terminal capacity 25sqmm protection class IP-20, Protection class with enclosure IP-40, DIN Rail mounting method, Vibration Resistance 3g, Shock Resistance 40mm free fall complete all as specified and as directed. |
| 34 | 1. Drilling pilot bore hole of 150mm dia by rotary drilling method (Direct/reverse) through rig machine for injection well in any kind of soil strata or rock including disposal of surplus soil/rock to a distacne not exceeding 50 metre complete all as specified including deploying required rig machinery, T&P, equipment etc. complete including transporting of all materials like rig machine, tools & plants, collection of log samples (drilling /cutting) and to maintain drill time log book all as specified and directed (for 01 bore holes). |
| 35 | 2. Reaming of 150mm pilot bore hole to 300mm bore with direct circulation rig machine /reverse rotary circulation method in any kind of strata of soil /rock from ground level to 100 Metre depth below ground level all as specified and directed (for 01 bore holes). Please Enable Macros to View BoQ information |
| 36 | 2. Reaming of 150mm pilot bore hole to 300mm bore with direct circulation rig machine /reverse rotary circulation method in any kind of strata of soil /rock from ground level to 100 Metre depth below ground level all as specified and directed (for 01 bore holes). Please Enable Macros to View BoQ information |