Sales : +91-777 804 8217
| Sl. No. | Item Description |
| 1 | Taking down wooden chowkhats or frames with shutters (without taking off shutters from the frames) area exceeding 1.50 sqm but not exceeding 4.00 sqm each complete all as specified and directed. |
| 2 | Taking down old defective chowkhats with shutter (without taking off shutters from the frame) n.exc 1.5 sq.m each and removing away from site, complete all as specified and directed. |
| 3 | Taking down old defective shutters of any description (wooden or aluminium) exc 1.0 sqm but n. exc 2.0 sqm each complete all as specified and directed. |
| 4 | Taking down old defective shutters of any description (wooden or aluminium) n. exc 1.0 sq.m each complete all as specified and directed. |
| 5 | Taking down and refixing in same opening wooden door shutter area not exceeding 1.00 sqm each complete all as specified and directed. |
| 6 | Taking down and refixing in same opening door shutter area exceeding 1.00 but not exceeding 2.00 sqm each complete all as specified and directed. |
| 7 | S&F 2nd class hardwood plain, solid, straight chowkhats and frames, wrought, framed, rebated on the solid, rounded or chamfered, put together with glue, pinned at joints complete all as specified and directed. |
| 8 | S&F 35 mm thk Flush door shutters solid core construction with block board core and ply wood face pannels commercial veneered on both faces complete alll as specified and directed. |
| 9 | S&F 35mm thick, 2nd class hard wood, Glazed and skeleton door shutters, open rebated and prepared to receive glass, gauze, etc. (with sash bars), but divided into squares, with plain, chamfered or rounded, mitred and rebated sash bars, edges of framing plain, chamfered or rounded, fitted with cut and mitred beads for securing glass, etc.; sizes of members of shutters as specified in SSR Part I, Section 8, clause 8.24 (a); supplied and fitted to chowkats complete all as specified and directed. |
| 10 | M&L 30mm thick 2nd class hard wood factory made glazed and skeleton shutter, open rebated and prepared to receive glass, gauge etc. devided into squares with plain chamfered or rounded, mitred and rebated sash bars edges of framing plain, chamfered or rounded, fitted with cut and mitred beads for securing glass etc. sizes of members of shutters as specified in SSR Part-I Section-8 clause 8.24(b) complete all as specified and directed. |
| 11 | Supply and fixing of solid PVC door frames of size 50 mm x 47 mm made out of 5 mm thick plain colour PVC sheet reinforced with MS square tube all as per specification & drawing complete all as specified and directed. |
| 12 | S&F of Factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of MS tubes for top & bottom rails. MS frame shall be covered with heat moulded plain colour PVC 'C' channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rails on either side & as gap insert for top rail & bottom rail; Panelling of plain colour PVC sheet to be fitted in the MS frame welded / sealed to the stiles & rails with suitable PVC sheet beading, and jointed together with solvent cement, supplying & fixing in the frame at site as per specification & drawing, complete all as specified and directed. |
| 13 | S & F stainless steel wire cloth, 0.36 mm nominal dia of wire and average width of aperture 1.40 mm and fixed with stainless steel wire staples complete all as specified and directed. |
| 14 | Supply & fix sheet glass, ordinary quality, 4 mm thick and glazed with oil putty or fixed with beads in square not exceeding 0.5 Sqm in each pane complete all as specified and directed. |
| 15 | S & F 100 mm medium weight mild steel butt hinges made out of cold reduced low carbon steel or hot rolled carbon steel as per IS 1341: 1992 complete all as specified and directed. |
| 16 | S & F extruded aluminium alloy handle, fabricated type, 100 mm size, anodized to a bright natural, mat finish not be less than Grade AC 10 of IS 1868 : 1996 complete all as specified and directed. |
| 17 | S & F aluminium barrel tower bolts with barrel and bolt of extruded sections of aluminium alloys, 100 mm long, anodized finish not be less than Grade AC 10 of IS 1868 : 1996 with transparent anodic film complete all as specified and directed. |
| 18 | S & F aluminium barrel tower bolts with barrel and bolt of extruded sections of aluminium alloys, 150 mm long, anodized finish not be less than Grade AC 10 of IS 1868 : 1996 with transparent anodic film complete all as specified and directed. |
| 19 | S&F brass chromium plated magic eye complete all as complete all as specified and directed |
| 20 | S & F extruded aluminium alloy handle, fabricated type, 150 mm size, anodized to a bright natural, mat finish not be less than Grade AC 10 of IS 1868 : 1996 complete all as specified and directed. |
| 21 | S & F in repairs exposed type hydraulically regulated door closers, universal closer, tubular type (type B), Designation No. 3, suitable for 61 kg to 80 kg mass of doors & 851 mm to 1000 mm width of door, extruded aluminium alloy non porous body and black plate, aluminium alloy piston or pack piston/ pillion, anodized finish not be less than Grade AC 15 of IS 1868 : 1996 with transparent anodic film as per IS 3564:1995 complete all as specified and directed. |
| 22 | S & F aluminium alloy sliding door bolts with hasp, staple and fixing clips of sheets, or extruded sections and fixing bolts and sliding bolts of extruded sections of aluminium alloy, 300 mm long, anodized to a bright natural, mat finish not be less than Grade AC 10 of IS 1868 : 1996 complete all as specified and directed. |
| 23 | S & F floor door stoppers made out of aluminium alloy pressure die casting body and tongue with hard drawn steel wire spring, overall length of cover plate 140 mm, 4.5 mm thickness of cover plate, anodized to a bright natural, mat finish not be less than Grade AC 10 of IS 1868 : 1996, suitable for 30 & 35 mm thickness of door shutter, fixed in floor complete all as specified and directed. |
| 24 | S & F mortice lock, vertical type, cast brass, 4 levers, vertical type, 100 mm size, finished smooth fixed in position complete all as specified and directed. |
| 25 | M & L for powder coated (colour) aluminium frame for doors, windows, ventilators (thickness of powder coating not less than 50 micron) with one or more rebates including joining cleat for fixing including handle, tower bolt, door stopper, grills etc. complete all as specified and as directed. Note:- Design/ pattern, profile sizes and other dimensions shall be of standard size and directed. |
| 26 | M & L for powder coated (powder coating min 50 micron) Anodised aluminium window and ventilator shutters, side hung type without sash bars, aluminium sections weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws, anodised aluminium fittings such as peg stays 150mm long (1 No.). hinges type B-21 100mm long (2 No.) suitable handle (1 No.) complete all as specified and directed. |
| 27 | S&F three track sliding powder coated coloured (powder coating min 50 micron) anodised window and ventilator shutters side hung/sliding type without sash , aluminium section weighing 0.55 kg/m including necessary joining cleats,glazing clips, rubber neoprene packing , anodised aluminium snap beading screws ,anodised aluminium fittings such as peg stays 150 mm long(1 No) hinges type B-21 100 mm long (2 No) suitable handle (1 No.) complete all as specified and directed. |
| 28 | S & F hot rolled medium and high tensile structural steel of grade E165 as per IS 15911: 2010 as in framed work such as grills, grating, etc., with ends of bars of shouldered and/or riveted, or forged into spikes, framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework water tanks and similar work ccomplete all as specified and directed. |
| 29 | Supply & fix sheet glass, ordinary quality, 5.5 mm thick and glazed with oil putty or fixed with beads in square exceeding 0.5 Sqm in each pane complete all as specified and directed. |
| 30 | Supply & fix toughened safety (tempered) glass (TS) as per IS 2553 (Part-1): 1990, flat, tinted 12 mm thick, fixed with steel, aluminium, metal frame work including rubber beading complete all as specified and directed. |
| 31 | Hacking out old broken glass (any thickness, size, quality or description) from wooden frames or stone, concrete or brick surrounds, glazed with putty or fixed with beads complete all as specified and directed. |
| 32 | S & F 3 mm thick figured glass, pin head type and glazing with oil putty or fixed with beads in square not exceeding 0.5 sqm in each pane complete all as specified and directed. |
| 33 | Dismantling wooden boarding, any description, fixed in any position with nails complete all as specified and directed. |
| 34 | S&F 2nd class SW boarding 20mm thick fixed with nails in eaves board plained one side with butt joint complete all as specified and directed. |
| 35 | Dismantling timber scantlings in unframed works, 40 sqcm and over in section, in any position complete all as specified and directed. |
| 36 | Dismantling wooden fillets, rails, posts, rafters, purlins, etc. under 40 sqcm in section in unframed works, in any position complete all as specified and directed. |
| 37 | M & L for structural timbers of group B, first or second choice as per IS 3629: 1986, clean sawn in scantlings and timber fixed complete all as specified and directed. |
| 38 | M & L for structural timbers of group B, 2nd class hardwood as per IS 3629: 1986 in fillets, square, rectangular or triangular in section, clean sawn, secured with screw, area exceeding 13 sqcm but not exceeding 25 sqcm complete all as specified and directed. |
| 39 | M & L for 5 mm thick PVC sheet fillet of width 35 mm for wall paneling inclusive of fixing on to wall to make PVC Frame as per specification and drawing complete all as specified and directed. |
| 40 | M & L for 12 mm thick (7 ply) plywood, boiling water resistance(BWR) Grade and Type BB as per IS 303: 1989 and IS 848: 2006; fixed with screws to timber frame work complete all as specified and directed. |
| 41 | S & F 1 mm thick, type S (Standard type), wear index No. 3, Impact Index No. 2, Scratch Index No. 3, one side decorative, laminate as per IS 2046: 1995 of surfaces finish, colour and pattern as per approved, fixed with approved adhesive as per manufacturer's instructions complete all as specified and directed. |
| 42 | M & L for 6 mm thick (5 ply) plywood, boiling water resistance(BWR) Grade and Type BB as per IS 303: 1989 and IS 848: 2006; fixed with screws to timber frame work complete all as specified and directed. |
| 43 | M & L for teak wood lipping, 6 mm thick for 20 mm thick, block board, veneered particle board, prelaminated particle board fixed with nails complete all as specified and directed. |
| 44 | S & F aluminium alloy hasps and staples, type -1, safety type, size 100 mm, anodized finish not be less than Grade AC 10 of IS 1868 : 1996 including fixing with screws complete all as specified and directed. |
| 45 | S & F mild steel continuous hinge, 30 mm nominal size, 1 mm thick, type IV as per IS 3818: 1992, bright finish and fixed to cupboard shutter complete all as specified and directed. |
| 46 | S & F 40 mm dia, cupboard knobs fixed with nut, screw and washer of brass, polished complete all as specified and as directed. |
| 47 | S&F ball catches with 8mm dia steel ball and brass body and striking plate including letting in and fixed, complete all as specified and directed. |
| 48 | Demolition of brick work or stone/boulder masonry, built in cement mortar including all quoins, arches, pillars, etc. complete all as specified and directed. |
| 49 | M & L for precast cement concrete solid block masonry of grade C(5.0) with concrete M 10 (Nominal Mix) using 20 mm nominal size graded crushed stone aggregate exceeding 10 cm in width and set in cement mortar (1:6) complete all as specified and directed. |
| 50 | M & L for precast cement concrete solid block masonry n exc 10cm in width as per IS 2185 (part-1): 2005, masonry of grade C(5.0) with concrete M10 (Nominal Mix) using 20 mm nominal size graded crushed stone aggregate, and set in cement mortar (1:4) complete all as specified and directed. |
| 51 | Taking down plastering on lathing (other than wire-netting), without removing lathing, in cement lime or cement mortar (one side only measured in cases where both sides are plastered) complete all as specified and directed. |
| 52 | Material and labour for plastering 10 mm thick on the other side of lathing (on vertical surfaces) in cement mortar 1:4 finished even and fair complete all as specified and directed. |
| 53 | Material and labour for plastering 15 mm thick on fair faces or the other side of lathing (on vertical surfaces) in cement mortar 1:4 finished even and fair without using extra cement and using water proofing compound @ 3% by weight of cement complete all as specified and directed. Note: Water proofing compound shall be measured and paid seperately. |
| 54 | Material and labour for plastering 5 mm thick on fair faces of brick work or concrete surfaces on ceilings in cement mortar 1:3 finished even and smooth without using extra cement complete all as specified and directed. |
| 55 | Supply only integral water proofing compound complete all as specified and directed. |
| 56 | M & L for preparation of new or previously untreated surfaces of wall and applying two coats of oil bound distemper over a coat of alkali resistant primer complete all as specified and directed. |
| 57 | M&L for preparation of new surfaces and applying two coats of 100% Premium acrylic emulsion paint having VOC less tham 50 gm/ltrs and UV resistance as per IS 15489:2004, alkali and fungal resistanxe dirt resistance exterior paint of required shade with silicon additives @1.43 ltrs/10sqm over and including priming coat of exterior primer applied @0.90 ltrs/10 sqm over new surfaces complete all as specified and directed. |
| 58 | M & L for 1 mm thick wall care putty on wall/ ceilings complete all as specified and directed. |
| 59 | M&L for preparation of old painted surface of steel and iron of any description, not otherwise described, over 10cm in width or girth and applying one coat of synthetic enamel paint, white or tinted complete all as specified and directed. |
| 60 | M&L for preparation of old painted surfaces of wood and wood based materials of any description, not otherwise described, over 10cm in width or girth and applying one coat of synthetic enamel paint, white or tinted complete all as specified and directed. |
| 61 | M & L for French polishing on surfaces of any description, width or girth including cleaning and preparing the surface including a coat of wood filler liquid transparent on old work with two or more coats complete all as specified & directed. |
| 62 | M & L for complete removal of existing treatment of wall and applying two coats of oil bound distemper over a coat of suitable primer with auto roller over 1mm thick wall care putty complete all as specified and directed. |
| 63 | M&L for complete removal of existing treatment and applying two coats of 100% Premium acrylic emulsion paint having VOC less tham 50 gm/ltrs and UV resistance as per IS 15489:2004, alkali and fungal resistanxe dirt resistance exterior paint of required shade with silicon additives @1.43 ltrs/10sqm over and including priming coat of exterior primer applied @0.90 ltrs/10 sqm over a coat of 1mm thick wall care putty to achieve a smooth surface complete all as specified and directed. |
| 64 | Dismantling of wall/ ceiling boards(fibre pulp insulation etc.) or insulations boards /slabs/blankets any thickness including cover fillets of any description including all snap grids and hanging arrangements complete all as specified and directed. |
| 65 | S&F of Gl frame work for seamless ceiling of grid size 605x605mm comprising of Gl perimeter channnel 0.55 mm thick with two unequal flanges of 20 and 30 mm and web of 27 mm fixed to surrounding wall using nylon sleeves and screws at 450 mm centre to centre/intermediate channel 0.9 mm thick having two equal flanges of 15 mm each and web of 45 mm suspended from soffit at approx 900 mm centre to centre with Gl cleat and steel expansion fasteners with and including ceiling section (not exc 1.2 m length) of 0.55 mm thickness having kurled web of 50 mm and flange of 26 mm each with lips of 10.5 mm fixed to the intermediate channel with connecting clips across the intermediate channel at 457 mm centre to centre complete all as specified and directed. |
| 66 | M& L for Providing and fixing 10mm thick plaster of paris ceiling (Gypsum anhydrous) to flat surface over 2nd class soft wood fillets, or metal frame work and reinforced with G.I. wire mesh (Fillets, metal frame work and G.I. wire mesh paid separately) complete all as specified and directed |
| 67 | S&F for Gl frame work for seamless ceiling comprising of Gl perimeter channnel 0.55 mm thick with two unequal flanges of 20 and 30 mm and web of 27 mm fixed to surrounding wall using nylon sleeves and screws at 450 mm centre to entre/intermediate channel 0.9 mm thick having two equal flanges of 15 mm each and web of 45 mm suspended from soffit at approx 900 mm centre to centre with Gl cleat and steel expansion fasteners with and including ceiling section (not exc 1.2 m length) of 0.55 mm thickness having kurled web of 50 mm and flange of 26 mm each with lips of 10.5 mm fixed to the intermediate channel with connecting clips across the intermediate channel at 457 mm centre to centre and Hangers 6 mm dia. G.I. (upto 1200mm length) adjusting level fixed to roof slabs by means of ceilling cleats made out of G.I. flat 40 x 3 mm size 60mm long and expansion hold fasteners 12.5mm dia. 40mm long complete all as specified and directed. |
| 68 | M & L for 4 mm thick plain fibre cement flat sheets type B, any category as per IS 14862: 2000 (non-asbestos) building boards, cured in HPSC (high pressure steam curing ) process, highly chemical stabilised, design and texture as approved fixed to timber/GI /Aluminium framework with screw as in ceiling or sloping for jointless finish with jointing compound and jointing tape complete all as specified and directed. |
| 69 | Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and directed. |
| 70 | Demolition of cement concrete (unreinforced) of any description and in any position not otherwise specifically provided for and complete all as specified and directed. |
| 71 | M & L for cement concrete M15 (Nominal Mix) using 20 mm nominal size graded crushed stone aggregate as in floor 25 mm thick finished even and fair complete all as specified and directed. |
| 72 | M&L for 20mm thick granite (of any type) work (table rubbed and polished) in cooking platform, in toilets for fixing wash hand basin, counter slab, in steps, jambs, pillars, window cills and like, fixed in cement mortar 1:6 including pointing in white cement 1:2 using granite / marble dust with admixture of pigment to match with shade of granite, laid over and including 20 mm thick cement screed in CM 1:6, complete all as specified and directed. |
| 73 | M&L for Non Skid joint free coloured Ceramic tiles 7 to 8 mm thick (square or rectangular), area of each tile exceeding 0.06 Sqm but not exceeding 0.11 Sqm, in floors etc., set and jointed in neat cement slurry and pointed in white or coloured cement to match with the colour of tile, laid over and including screed bed or bedding layer of mortar, 15 mm thick, in CM 1:4 complete all as specified and directed. |
| 74 | M&L for joint free Non-skid ceramic colour tiles 7 to 8 mm thick , (square/rectangular), area of each tiles exceeding 0.11 Sqm but not exceeding 0.18 Sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match with the colour of the tiles over and including 15 mm thick screed bed in cement sand mortar 1:4 complete all as specified and directed. |
| 75 | M&L for Glazed ceramic tiles on vertical surface of size 450X 300X 7-8mm or 300x600x7-8mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match with shade of the tiles laid over and including 10mm thick rendering as backing coat in CM 1:4 with wire markings to receive tile over it, complete all as specified and directed. |
| 76 | M&L for light shade vitrified ceramic tiles 10 mm thick (square / rectangular) polished, area of each tiles not exceeding 0.36 Sqm, in floors etc., set and jointed in neat cement slurry and pointed in white or coloured cement to match colour of tile, laid over and including 15mm thick screed bed in CM 1:4, complete all as specified and directed. |
| 77 | M & L vitrified ceramic tiles light shade 9 to 10mm thick area of each tile not exceeding 0.36 sqm, in skriting dado etc., set and jointed in neat cement slurry and pointed in white or coloured cement to match colour of tiles, over and including 10 mm thick rendering in cement mortar 1:4 complete all as specified and directed. |
| 78 | M&L for Virified Ceramic tiles light shade 10 mm thick (square/ rectangular) polished, area of each tiles exceeding 0.42 sqm but not exceeding 1.00 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over 15mm thick screed bed in CM 1:4 complete all as specified and directed |
| 79 | M&L for Virified Ceramic tiles light shade 10 mm thick (square/ rectangular) polished, area of each tiles exceeding 0.42 sqm but not exceeding 1.00 sqm, in skirting etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over 10mm thick screed bed in CM 1:4 complete all as specified and directed |
| 80 | S&F in repairs to 25mm dia (curtain rod) Harrison rails, aluminium anodised alloy wooden finish with fixing brackets, stops, rollers etc complete all as specified and directed |
| 81 | S&F of wooden finials with wooden finish for curtain rod of 25mm dia complete all as specified and directed. |
| 82 | Taking up or down 15 mm bore of steel tubing and connections, including cleaning for refixing or removal to store or taken on schedule of credit complete all as specified and directed. |
| 83 | Taking up or down 20 mm bore of steel tubing and connections, including cleaning for refixing or removal to store or taken on schedule of credit complete all as specified and directed. |
| 84 | Supplying & fixing to walls and ceilings or laid in floors 15 mm nominal bore, medium grade, galvanised coated steel tube conforming to IS 1239 (Part-1): 2004 including all fittings conforming to IS 1239 (Part-2): 2011 complete all as specified and directed. |
| 85 | Supplying & fixing to walls and ceilings or laid in floors 20 mm nominal bore, medium grade, galvanised coated steel tube conforming to IS 1239 (Part-1): 2004 including all fittings conforming to IS 1239 (Part-2): 2011 complete all as specified and directed. |
| 86 | M & L 75 mm thick plain cement concrete M10(Nominal Mix) using 40 mm nominal size graded stone aggregates finished surface even and fair as in plinth protection and making 50mm deep joints at every 3 mtr enterval and at every corners and filling the joints with bitumen grade 85/25 and sand mixture 1:3 complete all as specified and directed. |
| 87 | S&F in repairs Vitreous China Urinal, full stall type, white (excluding flushing cistern, flush pipe and waste pipe with grating and union for discharge pipe complete including providing and fixing plugs, bedding urinal against wall in cement mortar 1:2, securing urinal to plugs with and including 60mm long brass screws, pointing around urinal back in cement; also including brass chromium plated waste coupling 32mm dia, PVC flexible waste pipe of adequate length and dia complete all as specified and directed. |
| 88 | S&F in repairs Vitreous China Urinal, half stall type, white (excluding flushing cistern, flush pipe and waste pipe with grating and union for discharge pipe complete including providing and fixing plugs, bedding urinal against wall in cement mortar 1:2, securing urinal to plugs with and including 60mm long brass screws, pointing around urinal back in cement; also including brass chromium plated waste coupling 32mm dia, PVC flexible waste pipe of adequate length and dia complete all as specified and directed. |
| 89 | S & F in repairs Vitreous China EWC including seat cover closed pattern single piece size 755x365x655 complete all as specified and directed. |
| 90 | S & F in repairs 15 mm nominal size, nonrising spindle type fancy stop valves/ angle valve as per IS 8931: 1993 made of cast brass including Knob, knob components, divertor & components, nickel-chromium plated finish complete all as specified and directed. |
| 91 | S & F in repairs 5 mm thick bevelled edge mirror of selected quality glass, mounted on 6 mm thick AC building board or commercial plywood and fixed to wooden plugs with chromium plated brass screws and cup washers complete all as specified and directed. |
| 92 | S&F PVC SWR Nahani/ Floor trap plain with grating including jointing with solvent cement, dia of outlet 75 mm, water seal minimum 50 mm, complete all as specified and directed. |
| 93 | S & F in repair of PVC (SWR) as per IS 13592: 2013 single socketed soil waste pipes in any length with rubber ring joints, 110 mm dia, laid in trenches complete all as specified and directed. |
| 94 | S & F in repair of PVC SWR type B as per IS 13592: 2013 single socketed soil waste pipes in any length with rubber ring joints, 75 mm dia, laid in trenches complete all as specified and directed. |
| 95 | S & F in repair of PVC bends without inspection door (any angle), 110 mm dia conforming to IS 14735: 1999 complete all as specified and directed. |
| 96 | S & F 15 mm gun metal, globe or gate valve with iron wheel head, screwed both ends for iron pipe and fixed to pipe complete |
| 97 | S & F of PVC bends without inspection door (any angle), 75 mm dia conforming to IS 14735: 1999 complete all as specified and directed. |
| 98 | S&F PVC connections of length 450mm, 15 mm size with PTMT nuts complete all as specified and directed. |
| 99 | S&F in repairs Brass CP 2-in-1 Bib cock with flange complete all as specified and directed |
| 100 | S&F in repairs vitreous China clay table top WHB of size 700x435x135 mm incl waste coupling complete all as specified and directed. |
| 101 | S & F in repairs 15 mm dia brass CP centre hole basin mixer for mixing hot & cold water screwed down for iron pipe and fixed as in repairs, complete all as specified and directed. |
| 102 | S & F in repair 10 litres cap PVC, valve less, syphonic action type, flushing cistern, low level, white, with inlet, ball valve, float and handle including brackets with 32mm dia PVC pipe 600 mm long complete all as specified and directed |
| 103 | M&L for forming jambs, etc. to openings CM 1:4 (to foregoing item), including cutting, toothing and properly bonding into old work, also facing, jointing and pointing to match existing work, complete all as specified and directed. |
| 104 | S & F in repair health faucet (ABS Body) mild steel chromium plated suitable for 15 mm dia pipe with 1.25 metre long flexible tube and ABS wall hook including making connections and fixed in position complete all as specified and directed. |
| 105 | S&F in repair for vitreous china soap tray, approximate size 160 mm X 160 mm X 90 mm embedded in the wall washers complete all as specified and directed. |
| 106 | S & F in repairs toilet paper holder of vitreous china, box type, white fixed to walls with chromium plated brass screws complete all as specified and as directed. |
| 107 | S & F in repair towel ring of PTMT fixed with and including chromium plated brass screws and wooden / plastic cleats (Minimum weight of 90 Gms) complete all as specified and directed. |
| 108 | S & F 15mm bore Bib taps chromium plated fancy type, cast opper alloy with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed complete all as specified and directed. |
| 109 | S&F stainless steel gratings 150mm bore size fixed with cement motar complete all as specified and directed. |
| 110 | M & L for cement concrete in surface channels and drains in M10(Nominal Mix) using 40 mm nominal size graded crushed stone aggregate complete all as specified and directed. |
| 111 | S&F in repair rotational moulded polyethylene water storage tank 1000 litre capacity of triple layered layer wall construction (Cylindrical, vertical with closed top) hoisted and fixed in position including 20 mm dia ball brass valves, high pressure with polythene float and fly nut complete screwed for iron pipe or brass ferrule all as specified and directed. |
| 112 | Dismantling of plain or corrugated steel sheeting, any gauge, thickness including any pattern roof coverings complete all as specified and directed. |
| 113 | M & L for preparing surfaces of wood and wood based materials, new or old, of any description and girth, not otherwise described and treated with two coats of creosote oil complete all as specified and directed. |
| 114 | M & L for pre-painted hot-dip aluminium-zinc alloy metallic coated plain steel sheet as per IS 15965:2012 of durability class 3, atmospheric classification category 3, coating class AZ150, 0.50 mm thick, of an approved colour and having yield strength of 550 MPa as in ridge/ valley/ gutter fixed with self tapping screws as specified including necessary scaffolding and safety measures at any floor complete all as specified and directed. |
| 115 | M & L for pre-painted hot-dip aluminium-zinc alloy metallic coated corrugated steel sheet, any pattern corresponding to IS 15965:2012 of durability class 3, atmospheric classification category 3, coating class AZ150, 0.50 mm thick, of an approved colour and having yield strength of 550 MPa as in roof covering/ wall clading fixed with self tapping screws as specified including necessary scaffolding and safety measures at any floor complete all as specified and directed. |
| 116 | S & F 6 mm thick asbestos cement, corrugated or semi-corrugated sheets in roofs, walls etc. fixed with L type or J type or cranked hook bolts complete all as specified and directed. |
| 117 | Providing and fixing of 6 mm thick and 0.90m wide sheet to complete the roofing at the verge, ridge, hip, eaves, etc. hips in reinforced cement (non-asbestos cement), (as per IS 14871: 2000) fixed with L type or J type or cranked hook bolts complete all as specified and directed. |
| 118 | M & L for cement concrete M7.5 (Nominal Mix) using 40 mm nominal size graded crushed stone aggregate 75 mm thick in sub base for laying tiles, pavings, floorings etc. complete all as specified and directed. |
| 119 | Disconnecting existing water tanks capacity exceeding 500 litres but not exceeding 1000 Litres, setting aside (or lowering if required) for repairs, cleaning, etc. and hoisting if required, reconnecting and re-fixing in position. (cleaning repairing, etc. measured separately) |
| 120 | Demolition of reinforced cement concrete of any description (reinforcement cut as required to facilitate demolition) and in roofs, floors (other than ground floors), beams, staircases, landing, chajjas and similar suspended work complete all as specified and as directed. |
| 121 | Excavating in trenches not exceeding 1.5 m wide and not exceeding 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. or for cable laying or water supply pipes lines etc or not exceeding 10 sqm on plan and not exceeding 1.5 m in depth and getting out in soft/ loose soil complete all as specified and as directed. |
| 122 | Removing excavated material not exceeding 50 m and depositing where directed at a level n exc. 1.5 m above the starting point complete all as specified and directed. |
| 123 | Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm in soft/ loose/ hard/ dense soil complete all as specified and as directed. |
| 124 | M & L for cement concrete in foundation, filling and mass concrete in M7.5(Nominal Mix) using 40 mm nominal size graded crushed stone aggregate complete all as specified and as directed. |
| 125 | M & L for formwork to sides and soffits of domes, vaults, shell roofs and arch ribs for fair finished flat surfaces of concrete complete all as specified and as directed. |
| 126 | M & L for formwork to edges of concrete flats, treads, breaks in floors, window cills, concrete railings, openings in concrete walls, floor and roofs not exceeding 20 cm wide and sides of RCC/ PCC bands in walls, horizontal or sloping and similar work exceeding 10 cm but not exceeding 20 cm wide for rough finished surfaces of concrete complete all as specified and as directed. |
| 127 | M & L for RCC M15 (Nominal Mix) using 20 mm nominal size graded crushed stone aggregate as in domes, vaults, shell roofs, arch ribs and folded plates complete all as specified and as directed. |
| 128 | M & L for mild steel TMT bars 10 mm dia and over, cut to length, bent to shape required, including hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips and including welding has to be done with minimum 20 cm over lap for new and old of any height complete all as specified and as directed. |
| 129 | M&L for removal of existing movie chair from hall to store safely complete all as specified and directed. |
| 130 | S&F for 5 MM ACP Sheet (aluminium composite panel) sheet on wall/columns/roof required to fix with alum grid with any shape (back side framing) incl joint fillet with silicon of approved colour by GE complete all as specified and directed. |
| 131 | M & L for mild steel TMT bars 5 mm dia and over, upto and including 10mm dia as in stirrups, spaces and binders bent to shape as required including cranking, bending and binding with mild steel wire (annealed) not less than 0.9mm dia as in reinforcement bar complete all as specified and directed. |
| 132 | Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc. complete all as specified and directed. |
| 133 | Material and labour for Point wiring with 1.50 Sqmm single core PVC insulated, unsheathed cable FRLSH, 1100 volt grade with multi stranded copper conductor drawn through and incuding medium grade, ISI marked, PVC conduit not less than 20 mm dia with accessories, PVC conduit on wall/ceiling and incuding provision of 1.50 Sqmm single core PVC insulated , unsheathed cable FRLSH, 1100 volt grade with multi stranded copper conductor green colour as earth continuity conductor and connected to common earth dolly with suitable size of lugs, including mild steel sunken box/metal flush box with suitable modular or pressed steel terminal boxes made out of 1.6 mm thick mild steel sheet metal conforming to IS-5139(pt-I) of 1969 and IS:14772-2000 with earth dolly and coated with two coats of anti corrosive paint over a coat of red oxide primer both internally and externally including provision of new 3 mm thick plastic laminated sheet top cover for housing the switches , socket outlets, fan regulators etc. with brass screws and brass washers and making good the disturbed surfaces as per existing for one light/fan point controlled by one switch. |
| 134 | M & L for point wiring for one bell/ buzzer point controlled by one push button on independent board complete with and including single core PVC insulated, unsheathed flexible conductor FR-LSH cables 1.5 sqmm as per IS 694: 2010, ISI marked, annealed, multistranded copper conductor drawn through & including medium mechanical stresses class PVC conduit as per IS 9537 (Part-III): 1983 of suitable nominal size as required at site dia but not less than 20 mm nominal size including all accessories/ fittings/ junction boxes/ inspection cover etc. ISI marked and sunk terminal boxes flush galvanised metal boxes suitable for fixing with 1.5 sqmm copper conductor PVC insulated, unsheathed flexible multistranded copper conductor FR-LSH cable as continuous earth wire connected to metallic body at one end and common earth dolly to other end complete all as specified and as directed. |
| 135 | M & L for point wiring for one 3 pin/ 5 pin 5 Amps socket outlet on the same board complete with and including single core PVC insulated, unsheathed flexible conductor FR-LSH cables 1.5 sqmm as per IS 694: 2010, ISI marked, annealed, multistranded copper conductor drawn through & including medium mechanical stresses class PVC conduit as per IS 9537 (Part-III): 1983 of suitable nominal size as required at site dia but not less than 20 mm nominal size including all accessories/ fittings ISI marked suitable for fixing with 1.5 sqmm copper conductor PVC insulated, unsheathed flexible multistranded copper conductor FR-LSH cable as continuous earth wire connected to metallic body at one end and common earth dolly to other end complete all as specified and as directed. Please Enable Macros to View BoQ information |
| 136 | M & L for point wiring for one 3 pin/ 5 pin 5 Amps socket outlet on the same board complete with and including single core PVC insulated, unsheathed flexible conductor FR-LSH cables 1.5 sqmm as per IS 694: 2010, ISI marked, annealed, multistranded copper conductor drawn through & including medium mechanical stresses class PVC conduit as per IS 9537 (Part-III): 1983 of suitable nominal size as required at site dia but not less than 20 mm nominal size including all accessories/ fittings ISI marked suitable for fixing with 1.5 sqmm copper conductor PVC insulated, unsheathed flexible multistranded copper conductor FR-LSH cable as continuous earth wire connected to metallic body at one end and common earth dolly to other end complete all as specified and as directed. Please Enable Macros to View BoQ information |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail