|
| 1 | (B/R PORTION) S&F in repair Chromium plated brass Pillar tap fixed to wash hand basin, etc. complete all as specified and as directed. |
| 2 | S&F in repair 15mm CP bib taps, cast copper alloy fancy type with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed complete all as specified and directed. |
| 3 | S&F in repair Chromium plated brass two way Bib cock with wall flange fixed to 15 mm bore of Iron pipe complete all as specified and directed. Make : Ess Ess 203 G or equivalent make specified in tender. |
| 4 | S&F in repair brass chromium plated shower rose 125mm size and 9\\" long with or without swivel joints any size, including fixing to steel pipe complete all as specified and directed . |
| 5 | S&F in repair brass CP 15 mm mixer for mixing hot & cold water screwed down for iron pipes etc complete all as specified and directed by Engineer-in-Charge. |
| 6 | S&F in repair Stop valve / angle valvecast copper alloy chromium plated 15mm dia, screwed down, high pressure with capstan handle, screwed both ends for iron pipes or for unions and fixed with long shank and cup (concealed type) complete all as specified and directed by Engineer-in-Charge. |
| 7 | S&F in repair Health faucet (ABS Body) mild steel chromium plated suitable for 15 mm dia pipe with 1.25 metre long flexible tube and ABS wall hook including making connections and fixed in position complete all as specified and directed. |
| 8 | S&F in repair brass CP tubular Towel rail 600mm long and 20mm dia with cromium plated brass screws and wooden/plastic cleats complete all as directed. |
| 9 | S&F in repair 600mm x 450mm bevelled edge mirror of selected quality glass, moulded on 6mm thick commercial ply wood and fixed to wooden plugs with cromium plated brass screw and cup washers complete all as specified and directed. |
| 10 | Repair to CP brass item of Bib tap, Stop cock, Pillar tap, angular cock, shower rose, hand shower, health fauchet etc of 15mm size including replacement of washer/spindle if required in day to day maintenance complete all as specified and directed. |
| 11 | S&F in repair Grating doom 100mm dia of PTMT (Minimum weight 25gms) complete all as specified and directed . |
| 12 | S&F in repair PVC conncetion 450mm long fixed with 15mm GI pipe complete all as specified and directed. |
| 13 | All as per item No 12.00 abobe but 600mm long. |
| 14 | S&F in repair Plastic seat cover in white or any colour of EWC with flat bottom incl hanging device complete all as specified and directed |
| 15 | S&F in repair 32 mm bore CP bottle trap having minimum water seal of 25mm .(Minimum weight 32mm-260gms/40mm-270 gms) connected to pipe complete all as specified and directed |
| 16 | S&F in repair PVC flushing cistern 9 to10ltrs capacity fixed with GI pipe incl all fittings with PVC down pipe complete all as directed . |
| 17 | Repair only to flushing cistern incl cleaning and replacement of washer and syphonage of suitable size if required complete all as specified and directed. |
| 18 | Taking up or down steel water tubing 15 mm bore incl connection , cleaning etc any height of bldg complete all as specified and directed. |
| 19 | All as per item No 18.00 abobe but 20 mm bore any height of bldg |
| 20 | All as per item here-in-before but 25mm bore. Any height of bldg |
| 21 | S&F tubes 15mm bore medium grade galvanised with all fittings and fixed complete to wall and ceiling or laid in floors.Any height of bldg complete all as specified and directed. |
| 22 | All as per item No 21.00 abobe but 20mm bore.Any height of bldg |
| 23 | All as per item No 21.00 abobe but 25mm bore.Any height of bldg |
| 24 | Refixing old steel tubing 15mm bore and connection in new or old position(wall, ceiling, floor etc.).Any height of bldg |
| 25 | All as per item No 24.00 abobe but 20mm bore.Any height of bldg |
| 26 | All as per item No 24.00 abobe but 25mm bore.Any height of bldg |
| 27 | S&F in repair of 2000 ltrs capacity rotational moulded polyethylene water storage tanks (Cylindrical verticle with closed top) hoisted and fixed in position including suitable float valve fixed with GI pipe complete all as specified and directed. |
| 28 | Disconnecting of existing tanks 2000 ltr capacity, setting aside (or lowering if required) for repairs, cleaning, etc. and hoisting if required reconnecting and re-fixing in position. (Cleaning repairing, etc. measured separately) etc, compete all as directed. |
| 29 | Disconnecting of existing tanks 1000 ltr capacity, setting aside (or lowering if required) for repairs, cleaning, etc. and hoisting if required reconnecting and re-fixing in position. (Cleaning repairing, etc. measured separately) etc, compete all as directed. |
| 30 | Dismantling of floor hearth, wall tiling incl cement mortar bedding( but not backing) removing of serviceable tiles to store and rubbish off the premises complete all as specified. |
| 31 | M&L for 40mm thick PCC 1:2:4 type B-1(using 20mm graded stone aggregate) as in sub base of floor complete all as specified and directed. |
| 32 | M&L joint free coloured tiles 7-8mm thick area of each tiles exc 0.11 sqm but n.exc0.18sqm (400X400X7-8mm),as in floors etc.set and jointed in neat cement slurry and pointed in white or coloured cement to match incl 15mm thick screed bedding in CM 1:6 complete all as specified and directed. |
| 33 | Demolition of cement concrete (unreinforced) of any description and in any position not otherwise specifically provided for, all as specified and as directed . |
| 34 | M&L for virified Ceramic tiles 10 mm thick (square/ rectangular) polished, area of each tiles not exceeding 0.36 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over laid screed bed 20 mm thick CM 1:6 complete all as specified and directed. |
| 35 | M&L coloured glazed ceramic tiles in vertical surfaces 450X300X7-8mm thick set and jointed in neat cement slurry and pointed in white or coloured cement to match incl 10mm thick backing coat in CM 1:4 complete all as specified and directed. |
| 36 | Repair/refixing of WHB with new brackets fixed on wall complete all as directed. |
| 37 | Taking down cement plaster on brick or stone walls etc including racking out joints, hacking for key and scrubbing down with water complete All as specified and as directed. |
| 38 | M&L 15mm thick cement plaster on brick or concrete walls finishing fair and even in CM 1:4 complete all as directed. |
| 39 | M&L 10 mm thick cement plaster on brick or concrete surfaces without using extra cement finishing fair and even in CM 1:6 including necessary scaffolding complete all as directed. |
| 40 | M&L for rendering 5mm thick on fair faces of brick work or concrete ceiling surfaces in CM 1:3 finished rendering is to be finished even and smooth without using extra cement complete all as specified and directed. |
| 41 | Material & Labour for applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces complete all as specified and directed. |
| 42 | M&L Preparing new Plaster Surfaces of Wall and applying two Coas of oil bound distemper complete all as specified and as directed. |
| 43 | M&L Preparing new plaster surfaces of ceiling and applying two Coats of oil bound distemper complete all as specified and as directed. |
| 44 | S&F in repair Vitreous China wash down water closet pan (pedestal pattern), white (excluding fixing bolts, flushing cistern and flush pipe) complete with plastic water closet seat cover whiteclosed pattern with flat bottom, and cover and mild steel chromium plated or aluminised hinges device including connecting to flush pipe complete all as specified and directed. |
| 45 | S&F in repair Wash basins, Vitreous China (flat back or angle back type) of size 630 x 450mm, including cutting for and pinning in ends of brackets or erecting stand, brackets but exclusive of waste pipe etc complete all as spd and as directed. |
| 46 | S&F in repair 40mm dia PVC pipe with bend complete fixed on walls, ceilings and floors incl GI/PVC clamps, bends sockets etc incl taking down U/S old PVC pipes complete all as specified and directed. |
| 47 | M&L for small repair of hinges for door and window, adjustable for sliding door bolts, tower bolts, repair of handles, mortice locks etc for similar type of works complete all as directed . |
| 48 | Taking down chowkhat or frames with shutters (without taking off shutters from the frame) area exc 1.5 Sqm and n.exc.4.00 Sqm each wooden all as directed. |
| 49 | Taking down shutters of any description exc 1.00 sqm but n.exc 2.00 Sqm each all as directed. |
| 50 | S&F for 2nd class HW, plain, solid, straight chowkats and frams, wrought, framed, rebated on the solid, moulded or chamfered, put together with glue, pinned at joints complete all as directed. |
| 51 | S&F 30mm thick 2nd class hard wood glazed & skleton shutters, open rebated and prepared to received glass, gauge etc.(without sash bars) edges of framing plain chamfered or rounded, fitted with cut and mitred beads for securing glass etc, size of members of shutters as specified in SSR Part-I section 8, clause 8.20(a) complete all as directed. |
| 52 | S&F Factory made 30mm thick with 2nd class hard wood, rail and style factory made plain framed panelled shutter with lock, rail and panel of 9mm BWP commercial ply or 12mm veneered particle board with commercial veneering on both faces. The size of rail & style as per IS:1003(Part-I) kiln seasoned and chemically pressure treated. |
| 53 | Taking down PVC door shutter with PVC chowkats including all fittings area exc 1.00 Sqm but n.exc 2.00 Sqm all as directed. |
| 54 | S&F Factory made solid PVC door frame (chowkhat) of size 50mmx47mm made out of 5mm plain colour wood grain PVC sheet used instead of plain colour PVC sheet & edges will be painted to match with printed sheet reinforced with MS square tube, S&F in opening as per specification & drg as per manufacturer instrutions complete all as specified and directed. |
| 55 | s& f Factory Made Solid PVC MouldedDoor Shutter, 28 to 30mm thick (stiles), with 2, 4, or 6 raised panel design with 2mm thick Moulded prelam PVC Sheet on the front face & 2mm plain colour PVC sheet on back face, supplying & fixing in frame at site as per specification & drawing complete all as specified and directed. |
| 56 | S&F 100mm butt hinges stainless steel medium weight complete all as specified and directed. |
| 57 | S&F aluminium handle, cast type anodised 125mm size all as directed. |
| 58 | S&F 150mm aluminium anodised barrel tower bolts of extruded section complete all as specified and directed. |
| 59 | S&F 300mm aluminium, anodised sliding door bolt with hasp, staple(bolt type) and fixing clip of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded section or cast aluminium alloy all as directed complete all as directed. |
| 60 | S&F stainless steel wire cloth, 0.36mm nominal dia of wire and average width of aparture 1.40mm and fixed with stainless steel wire staples complete all as directed. |
| 61 | All as per item No 60.00 abobe but fixed in repair. |
| 62 | Hacking out old broken glass (any thickness and size or quality) from metal frames glazed with putty or fixed with beads complete all as specified and directed. |
| 63 | S&F 3 mm thick ordinary quality sheet glass/frosted glass and glazing with oil putty in square n.exc. 0.5 Sqm in each pane complete all as directed. |
| 64 | Taking down steel window/ventilators of any size including grill/guard bars and removing to store complete all as directed. |
| 65 | S&F powder coated anodised aluminium doors frame for doors, windows, ventilators with one or more rebates including joining cleat for fixing etc complete all as specified. |
| 66 | S&F aluminium anodised powder coated for doors,windows,ventilators and partition with one or more rebate (Minimum thickness of powder coating 50 micron) and Three track with 1.80 mm thick channel section and shutter frame thickness 1.65 mm without sash bars,Aluminium section weighing 0.55 kg/mtr including necessary joining cleats,glazing clips,rubber packing,anodised aluminium snap beading,screws etc.Complete all as specified and directed. Note:- 1.Size of window shall be as per site requirement. 2. Glass & wire cloth shall be measured separately. |
| 67 | S&F Anodised aluminium grill (anodised transparent or dyed to required shade according to IS: 1868 with minimum anodic coating of grade AC 15) of approved design/pattern, with approved standard section and fixed to the existing window frame with C.P. brass/ stainless steel screws @ 200 mm centre to centre, including cutting the grill to proper opening size for fixing and operation of handles and fixing approved anodised aluminium standard section around the opening, all complete as per requirement and direction of Engineerin-charge. |
| 68 | S&F 4mm thick ordinary quality sheet glass/frosted glass and glazing with oil putty in square n.exc. 0.5 Sqm in each pane complete all as directed. |
| 69 | Preparing new surface of wood or wood based material of any description and in any position not otherwise described n.exc 10cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer complete all as directed. |
| 70 | S&F in repair 20mm dia fancy type Harrison rails (Curtain rod) mild steel, chromium plated including fixing brackets, stops, rollers et fixed on wall sample as approved by GE complete all as directed. |
| 71 | M&L in repair 18/19mm thick pre-laminated particle board as in cup board shutter double leaf one side decorative of sheds and other side balancing white lamination. All edgs properly seald with 5mm thick 2nd class hard beading fixed with water resistant adhesive except rebate side which shall be of 25mm thick as in repair complete all as directed. |
| 72 | S&F in repair drawer knobs 40 mm dia of brass polished fixed with nut screw and washer all as directed. |
| 73 | M&L in repair for 300mm MS ordinary helical springs including roller and roller plate complete all as directed. |
| 74 | M&L in repair19 to 20 mm thick black/coloured granite machine cut laid over 10mm thick screed bed in cm 1:4 and jointed with grey or coloured cement to match with admixture of pigment to match the shade of granite including cutting polishing all as specified and as directed. |
| 75 | Providing and applying plaster of paris putty of 1 mm thickness over plastered surface to prepare the surface even and smooth complete all as specified and directed. |
| 76 | M&L Preparing old decorated Plaster Surfaces of Wall washing,rubbing down and stopping of distempeered and painted surfaces of wallas and applying one Coat of oil bound distemper complete all as specified and as directed. |
| 77 | M&L Preparing old decorated plaster surfaces of ceiling and applying One Coat of oil bound distemper complete all as specified and as directed. |
| 78 | M&L Preparing old Wooden Surfaces of any description not otherwise decribed over 10 Cm width or girth and applying One Coat of Synthetic Enamel Paint (First quality), complete all as specified and as directed. |
| 79 | M&L Preparing old Painted Steel Surfaces over 10 Cm width or girth not otherwise described and applying One Coat of Synthetic Enamel Paint (First quality), complete all as specified and as directed. |
| 80 | Material & Labour preparation of old surface of walls applying one coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over all as specified and directed. (up to any high of building) |
| 81 | Taking down plants and vegetation from walls upto roof level by means of cutting Holes in Brick Walls, built in Cement Mortar of 150mm depth making good dismantled portion in cement mortar 1:3 or cement concrete 1:2:4 type B-1 as required n exc 150 sq.cm in superficial area, complete all as specified and as directed. |
| 82 | M&L for anti termite treating the soil under plinth protection at the rate of 5 litres of emulsion per square metre of surface area all as specified and directed. |
| 83 | Taking down/removing of existing water proofing treatment on roof surfaces and wall surfaces complete, including screed bed, racking out joints, hacking for key scrubbing down with water etc including dismantling of lightening strip if any and refixing the same in position, and removing rubbish out of MD land, all as specified. |
| 84 | M&L for 25mm thick cement concrete type B-0, 1:2:4 using 12.5mm graded aggregate in sub bases of floors complete all as specified and directed. |
| 85 | M & L for screed bed 15 mm thick (average) plaster on concrete surfaces in CM (1:3) on roof, mixed with water proofing compound and finishing the surface even and smooth without using extra cement all as specified and directed (Water proofing compound shall be measured and paid seperately). |
| 86 | M&L Water Proofing Treatment on existing cleaned RCC Roof with the following Specifications and Manufacturer's instructions, complete all as specified and as directed :-(a) Rendering 10mm thick in Cement Mortar 1:4, finished even and smooth and cured for 07 days by Ponding of water over Roof.(b) Preparing fully dried plastered surface as per IS:3067-1966, for further treatment.(c) Applying Bitumen Primer conforming to IS-3384-1986 over the Cleaned Plastered Surface @ 0.3 Litre per Sqm.(d) Applying a layer of APP based Polymeric Membrance; 3.0mm thick (minimum) weighing 3.50 Kilogram per Square Metre (reinforced) with Polyster Non Woven Fabric weighing not less than 160 Grams per Square Metre by Torch application. The overlaps shall be minimum 100mm on the Transverse direction and 75mm on Longitudinal direction.(e) Applying one coat of Aluminium Paint @ 0.10 Litre per Sqm over APP based Polymeric Membrane. |
| 87 | Supply only integral water proofing compound (ISI grade only) |
| 88 | M&L for anti termite treating the soil along with external perimeter of building at the rate of 2.25 litre of emulsion per metre of the perimeter wall all as specified and directed. |
| 89 | Dismantling plain or corrugated steel sheeting any gauge thickness including nanital or similar pattern roof covering all as specified and directed.Note :-Any height of bldg |
| 90 | S&F for pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified and directed. Note :-Any height of bldg |
| 91 | S&F for pre- painted galvalume aluminum zinc coating GI based plain steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified and directed. |
| 92 | Providing Skilled labour services for day to day minor repair & maintainance of daily complaints receive at complaint cell for plumbing and carpenting works including fixing of MES store items for POR 08 TO POR 19 ,in one shift per day except sunday & holidays by employing 01 pipe fitter to GE(FW) kolkata and all as specified & directed.NOTE;- (a) The contractor has to depute 01 no skilled pipe fitter for above mentioned job for ZONE-I area daily from 8.30 AM to 5.00 PM(b) All tools & Plants required for Job to be provided by contractor. |
| 93 | E/M PORTION Taking down carefully old unsv copper/aluminium point wiring (light, fan, socket or power) complete,including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets,sunken type box etc.and removing materials to store for keeping in safe custody for reuse at site or for taking credit and making good to disturbed surfaces of walls, floors etc with its original specification complete all as specified and directed. |
| 94 | Material and labour for concealed point wiring for the followings with 1.5 Sqmm single core, PVC FRLSH insulated unsheathed, multistranded copper conductor drawn through and including PVC concealed conduit including necessary accessories like bends, tees, PVC square and elbow etc fixed on wall/ceiling with 1.5 Sqmm PVC FRLSH insulated unsheathed multi stranded copper conductor cable as earth conitinuity (green in colour) connected to common earth dolly including sunken type pressed steel terminal boxes of suitable sizes with plastic laminated white/coloured top sheet cover 3 mm thick including making good all disturbed surfaces to match the existing complete all as specified and directed as below :- |
| 95 | (a) One light/fan point controlled by one,one way switch. |
| 96 | (b) One bell point controlled by one push button switch. |
| 97 | (c) One 3 Pin 5 Amps socket out let point on independent board. |
| 98 | (d) One 3 Pin 5 Amps socket out let point on same board alongwith other suitable switchs. |
| 99 | All as per item No 94 above here-in-before but using 4.00 sqmm PVC FRLSH insulated copper condutor wire for connecting 15A socket on independent board complete all as specified/directed. |
| 100 | Material and labour for point wiring surface type with 1.5 Sqmm single core, PVC FRLSH insulated unsheathed, multistranded copper conductor drawn through and including PVC casing and caping including necessary accessories like bends, tees, PVC square and elbow etc fixed on wall/ceiling with 1.5 Sqmm PVC FRLSH insulated unsheathed multi stranded copper conductor cable as earth conitinuity (green in colour) connected to common earth dolly including sunken type pressed steel terminal boxes of suitable sizes with plastic laminated white/coloured top sheet cover 3 mm thick including making good all disturbed surfaces to match the existing complete all as specified and directed as below :- |
| 101 | (a) One light/fan point controlled by one,one way switch. |
| 102 | (b) One bell point controlled by one push button switch. |
| 103 | (c) One 3 Pin 5 Amps socket out let point on independent board. |
| 104 | (d) One 3 Pin 5 Amps socket out let point on same board alongwith other suitable switchs. |
| 105 | All as per item No 96.00 abobe but using 4.0 sqmm PVC FRLSH insulated copper condutor wire for connecting 15A socket on independent board complete all as specified/directed. |
| 106 | Supply and fixing of switch piano flush type 240 Volts 5 Amps, SP, one way complete all as specifed/directed. |
| 107 | Supply and fixing of bell push piano flush type one way 240 Volts 5 Amps all as specified/directed. |
| 108 | Supply and fixing of switch socket outlet combination 3 Pin,5 Amps, 240 volts flush type (non shuttered) complete all as specified/ directed. |
| 109 | Supply & fixing of socket outlet 2 in 1,3 pin 5 Amps 240 Volts flush type (non shuttered) complete all as specified / directed. |
| 110 | Supply and fixing of switch socket out let combination multipurpose 3 pin, 15/16 Amps and (with 3 pin 5 Amps outlet also) flush type (non shuttered) complete all as specified/directed. |
| 111 | Supply and fixing of bell electric, 240 Volts, single pole complete all as specified and directed. |
| 112 | Supply & fixing of ceiling fan regulator electronic,Deluxe,rotary, step type, 120/280 volts as specified/directed. |
| 113 | Supply and fixing of Bulb holder angular PVC/Polycarbonate suitable for batten fittings complete all as specified/directed. |
| 114 | Supply and fixing of ceiling rose surface PVC/Polycarbonate, 65x50 mm two to three terminals complete all as specified/directed. |
| 115 | Taking down and refixing the same fixture i.e light fittings, ceiling fans, bulbs etc along with connected items complete all as specified and directed. Note:- item received from sl No 94 to 106 complete all as specified and directed. |
| 116 | Supply and fixing LED lights fitting 1x 20 W, 220V, AC decorative box with aluminum housing type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed. |
| 117 | Supply and fixing LED lights fitting 1x 10 W, 220V, AC decorative box with aluminum housing type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed. |
| 118 | S & F in Replacement for fittings with twin core PVC insulated and overall PVC sheathed cable with stranded aluminium conductor 1100 volts grade of size 4 sqmm including taking down old unserviceable wiringcomplete all as specified and directed. |
| 119 | Supply and fixing in repair of switch piano flush type 240 Volts 5 Amps, SP, one way,fix in repair including taking down old unsv complete all as specified and directed. |
| 120 | Supply and fixing in repair of bell push piano flush type one way 240 Volts 5 Amps,fix in repair including taking down old unsv complete all as specified/directed. |
| 121 | Supply and fixing in repair of switch socket outlet combination 3 Pin,5 Amps, 240 volts flush type (non shuttered) ,fix in repair including taking down old unsv complete all as specified/ directed. |
| 122 | Supply & fixing in repair of socket outlet 2 in 1,3 pin 5 Amps 240 Volts flush type (non shuttered),fix in repair including taking down old unsv complete all as specified / directed. |
| 123 | Supply and fixing in repair of switch socket out let combination multipurpose 3 pin, 15/16 Amps and (with 3 pin 5 Amps outlet also) flush type (non shuttered), fix in repair including taking down old unsv complete all as specified/directed. |
| 124 | Supply & fixing in repair of stepped type electronic fan regulator flush type on the existing phenolic laminated sheet including taking down old unsv complete all as specified and directed. |
| 125 | Supply and fixing in repair of bell electric, 240 Volts, single pole,fix in repair including taking down old unsv complete all as specified and directed. |
| 126 | Supply and fixing in repair of Bulb holder angular PVC/Polycarbonate suitable for batten fittings,fix in repair including taking down old unsv complete all as specified/directed. |
| 127 | Taking down and Rewinding of exhaust fan 200 to 350 mm sweep of any make with super enameled copper winding wire as per existing size and gauge including heating, varnishing, replacement of unserviceable/worn out parts for satisfactory running including electrically connected with flexible wire multi-stranded copper conductor cable of size 23/0.0076 from ceiling rose to fan and testing, complete all as specified and as directed Note:- Minor spares like capacitor wires are included in the above price. |
| 128 | Supply and fixed in repair Gun Metal Bush suitable for wall Fan /Exhaust Fan complete all as specified and as directed. |
| 129 | S&F in repair Modular switch 1 way 6A,1 module complete all as specified and directed. |
| 130 | S&F in repair Modular switch 1 way 16A,1 module complete all as specified and directed. |
| 131 | S&F in repair Modular switch 2 way 6A,1 module complete all as specified and directed. |
| 132 | S&F in repair Modular bell push 1 way 5A,1 module complete all as specified and directed. |
| 133 | S&F in repair burger ding dong type complete all as specified and directed. |
| 134 | S&F in repair Modular Socket, 6A - 2/3 pin combined 2 module, complete all as specified and directed. |
| 135 | S&F in repair Modular Socket, 6/16A - 2/3 pin combined 2 module, complete all as specified and directed. |
| 136 | S&F Fan step regulator, 120W - 2 module complete all as specified and directed. |
| 137 | S&F Fan capacitors 2.5 mfd complete all as specified and directed. |
| 138 | Supply and fixing in repair of MCB SPN DB 8 way double door,IP-43 protection,isolated neutral bar,insulated busbar assembly,mechanical impact strength of IK08 complete incl taking down old unsv all as specified and directed . |
| 139 | Supply and fixing in repair of MCB SPN DB 4 way double door,IP-43 protection,isolated neutral bar,insulated busbar assembly,mechanical impact strength of IK08 incl taking down old unsv complete all as specified and directed. |
| 140 | Supply & fixing in repair of MCB Isolator 4 pole, 100 Amps 'B' Series 10 KA 415 volts incl taking down old unsv complete all as specified/directed. |
| 141 | Supply & fixing in repair of MCB TPN 63 Amps 'B' Series 10 KA 415 volts incl taking down old unsv complete all as specified/directed. |
| 142 | Supply & fixing in repair of MCB SPN 40 Amps 'B' Series 10 KA 240 volts incl taking down old unsv complete all as specified/directed. |
| 143 | Supply & fixing in repair of MCB SP 6-32 Amps 'B' Series 10 KA, 240 volts incl taking down old unsv complete all as specified/directed. |
| 144 | Supply and fixing in repair of single Pole & Neutral enclosure with 2 pin and earth plug & socket for incorporating with single pole 20 Amp SP MCB all as complete including taking down old unsv one and directed . |
| 145 | Supply and fixing in repair of AC short circuit protection motor starter 25 Amps capacity, 230 Volt with MCB DP 25 Amps,plug top & socket complete 6 M including taking down old unsv complete all as specified and directed. |
| 146 | Supply and fixing in repair LED lights fitting 1x 20 W, 220V, AC decorative box with aluminum housing type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed. |
| 147 | Supply and fixing in repair LED lights fitting 1x 10 W, 220V, AC decorative box with aluminum housing type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed. |
| 148 | Supply and fixing LED luminaire 600 mm x 600 mm,35/36 wat, 220 V AC recessed type with highefficiency PMMA diffuser soft glare free light completewith driver, holders & LED lamp suitable for roofceiling including connecting up with driver threecore flexible copper conductor cases of suitable size complete all as specified and directed. |
| 149 | S & Fix Energy efficient light fitting (LED ) Sleek type of capacity 36 W fitting 4FT with extruded Aluminium Hosuing Lamps,driver,connector etc incl hanging/Fixing arrangement with PVC insulated three core flexible copper conductor of suitable size from ceiling rose to fitting through suitable size flexible PVC pipe making good to wall for old fitting including taking down old fitting of complete all as specified and directed. Make Philips Model No 581951 36 W ( Philips Ultron edge 4 ft LED wall Light or equiv Model of Jaquar/Surya. |
| 150 | Supply and fixed in repair PVC terminal Rectangular boxes of suitable size with 3 mm thick PVC /plastic laminated sheet, top cover suitable sizes of brass screws and washers etc. for mounting switches, sockets, regulators etc of size 100mmx100mmx50mm deep depends on the no of switch and socket complete all as specified and directed. |
| 151 | S&F of 20/25 mm conduit MMS including pin and clip complete all as specified and directed. |
| 152 | S&F of single core wire of 6.00 sqmm sheathed complete all as specified and directed. |
| 153 | S&F PVC flexible pipes from along with saddles from ceiiling rose to connctor fittings complete. Note:- Colour of pipes will be decided by the office. |
| 154 | Note: Schedule of credit (SCHEDULE OF CREDIT) amount of Rs ________ mentioned on Page No ____ shall be deducted from the total quoted amount of BOQ. Please Enable Macros to View BoQ information |