| 1 | Demoltion of Plain Cement Concrete (Un-reinforced) of any description and in any position not otherwise specifically provided for etc complete all as specified and as directed |
| 2 | Demolition of cement concrete and paving not exc 15 cm thick (below or above ground level) complete all as specified and as directed. |
| 3 | Demoltion of Reinforced Cement Concrete of any description and in any position not otherwise specifically provided for etc complete all as specified and as directed |
| 4 | Taking down chowkats or frames with shutters (without taking off shutter from frames) area not exc. 1.5 sqm each including making good the disturbed surfaces to match with the adjoining surfaces etc., complete all as specified and as directed |
| 5 | Taking down chowkats or frames with shutters (without taking off shutter from frames) area exc. 1.5 Sqm but n exc 4 Sqm each including making good the disturbed surfaces to match with the adjoining surfaces etc., complete all as specified and as directed |
| 6 | Taking down shutters of any description area not exc 1.00 Sqm each etc complete all as specified and as directed |
| 7 | M&L for Plain cement concrete (1:4:8) type D2 using 40mm graded crushed stone aggregate as in 100 mm thick sub base for path etc complete all as specified and as directed |
| 8 | M&L for Plain Cement concrete (1:2:4) type B-0 using 12.5mm graded stone aggregate as in 25 mm thick levelling course of flooing etc complete all as specified and as directed |
| 9 | M&L for PCC 1:3:6, type C-1, using 20 mm graded aggregates as in 75 mm thick plinth protection finished fair & even including joints filling with sealing compound Grade \\"A\\" complete all as specified and as directed. |
| 10 | M & L for Non - skid ceramic coloured tiles 7 to 8 mm thick (square / rectangular) area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm, in floors etc., set and jointed in neat cement slurry and pointed in white or coloured cement to match over & including 15 mm thick screed bed in cement mortar (1:6) including dismantling floor etc., complete all as specified and as directed |
| 11 | M & L for Non - skid ceramic coloured tiles 7 to 8 mm thick (square / rectangular) area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm, in skirting / dado etc., set and jointed in neat cement slurry and pointed in white or coloured cement to match over & including backing coat 10 mm thick cement mortar (1:4) including dismantling wall tiling etc., complete all as specified and as directed |
| 12 | M & L for Non - skid ceramic coloured tiles 7 to 8 mm thick (square/rectangular) area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over & including 15 mm thick screed bed in cement mortar (1:6) including dismantling floor etc., complete all as specified and as directed |
| 13 | M&L for Sand filling under floors or in foundations including watering and consolidation etc., complete all as specified and directed . |
| 14 | M&L for Machine pressed precast concrete interlocking paver block any shape and size confirming to IS 15658-2006 of 60mm thickness, M-35 Grade including dismantling existing stone slab / tiles laid dry complete all as specified and as directed . |
| 15 | M&L for Glazed ceramic coloured tiles 350X250X7mm / 450X 350X 7mm thick as in skirting / dado, set and jointed in neat cement slurry and pointed in white or colour cement to match over & including backing coat 10 mm thick in cement mortar (1:4) including dismantling wall tiling etc complete all as specified and as directed |
| 16 | M & L for Granite stone slab 18 to 20 mm thick(of any type) work (table rubbed and polished) in steps, jambs, pillars, walls, window- cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite over & including 15 mm thick screed bed in CM 1:6 complete all as specified and as directed |
| 17 | M&L for Pre-cast Cement concrete (1:3:6) type C-1 using 20 mm graded crushed stone aggregates as in solid block masonary exceeding 10 cm in width and setting in CM (1:6) including demolition of brick Work / Stone Masonry/PCC block masonry built in cement mortar all as specified and as directed. |
| 18 | M&L for Keyed pointing to random or polygonal rubble, uncoursed or brought upto course in CM (1:4) including raking out joints / pointing to masonry in single detached joints for flashing, etc complete all as specified and as directed |
| 19 | M&L for Reinforced Cement Concerete (1:2:4) (nominal mix) type B-0 using 12.5mm graded crushed stone aggregate as in damaged Chajja (soffits)/ down ward Facia/ Vertical Surface by complete removing of damaged portion, removing the rusted portion of steel iron, including necessary form work etc complete all as specified and as direted (Note : Reinforcement will be measured and paid seperately) |
| 20 | M&L for Pre-cast cement concrete (1:2:4) type B-1 using 20 mm graded stone aggregate as in landings, cover slab (for manholes etc) and similar work including necessary form work and set in CM (1:6) etc complete all as specified and directed. |
| 21 | M&L for TMT bars 10 mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia, or securing with clips etc complete all as specified and as directed |
| 22 | Taking down cement plaster of any description hacking for key or raking out joint on old brick work/stone/concrete surface etc complete all as specified and as directed |
| 23 | M&L for rendering 5 mm thick in CM (1:3) on fair faces of concrete ceiling surface finished even and smooth without using extra cement etc complete all as specified and as directed |
| 24 | M&L for rendering 10 mm thick in CM (1:6) on fair faces of brick work or concrete surface finsihed even and smooth without using extra cement etc complete all as specified and as directed |
| 25 | M&L for rendering first layer 10 mm thick in CM (1:6) on fair faces of brick work or concrete surface and second layer 5 mm thick in CM (1:4) mixed with water proofing compound as per manufacture instruction finished even and smooth without using extra cement etc complete all as specified and as directed (Notes : WPC will be measured and paid seperately) |
| 26 | M&L for providing water proofing treatment to sunken portion of WCs, bath room etc by applying cement slurry mixed with two component Elastomeric Acrylic based polymer modified cementitious composite compound coating all as per following specification including taking down existing treatment with PCC removing from site complete all as specified & directed :- (i) Rendering at bottom surface 20mm thick in cement mortar (1:3) mixed with liquid water proofing compound. (ii) Rendering at side wall surface 15mm thick in cement mortar (1:3) mixed with liquid water proofing compound. ...contd/- |
| 27 | (iii) First layer of slurry of cement @ 0.488 kg/sqm mixed with Acrylic based polymer modified cementitious composite compound @ 0.253 kg/sqm. The layer will be allowed to air cure for 4 hours. (iv) Second layer of slurry of cement @ 0.242 kg/sqm mixed with with Acrylic based polymer modified cementitious composite compound @ 0.126 kg/sqm. The layer will be allowed to air cure for 4 hours followed with water curing for 48 hours. (v) Provide 40mm dia light grade G I spout at the lowest point with 20cm projection beyond the outer face of the wall. (vi) Plain Cement concrete (1:5:10) type E-2 using 40mm graded brick aggregates filled in sunken portion of WC /bath room(Note:- Plan area will be measured for payment purpose). |
| 28 | M&L for Plain cement concrete (1:2:4) type B-0 using 12.50mm graded crushed stone aggregate in copings, parapets and railing upto 60cm height, leveling concrete for Roof slab, kerbs, water troughs /Chajjas and the like including weathering, slightly rounded or chamfered angles and throating including necessary formwork complete all as specified and as directed. |
| 29 | Taking down existing water proofing treatment over RCC roof slab including screed bed and removing from site complete all as specified and as directed. |
| 30 | M&L for screed bed/rendering 10mm thick in CM (1:3) over concrete roof surface mixed with water proofing compound, finished even & smooth complete all as specified and as directed.(Note : WPC will be measured & paid seperately) |
| 31 | M & L for water proofing treatment to RCC roof surface with following specification complete all as specified and as directed :-(i) Cleaning & removing all loose gravel, dirt, oil, grease and foreign materials by jet or dry air, mechanically or by grinding to make it smooth(ii) Applying compatible primer @ 0.30 Ltr/Sqm over surface (iii) Laying APP modified water proofing membrane as per IS 1654-2017/IS 16352-2017, 3mm thick and weighing not less than 3.80kg/Sqm reinforced with non woven polyster/HMHDPE matt black finished over and torch applications of membrane with 100mm side overlap and 150mm end lap complete as per manufacture's instruction(iv) Applying a coat of aluminum paint on top @ 0.10 litre/Sqm.(Note : Ponding test shall be carried out for 72 hours for seepage/leakage) |
| 32 | Supply only Liquid water proofing compound, ISI marked, complete all as specified and as directed. |
| 33 | S&F Pressed steel frame of profile size 125 X 60 mm for door with one or more rebate, made of 1.25 mm thick M S sheet, including necessary fixing lugs, hinges, locks strike plate etc complete all as specified and as directed |
| 34 | S&F Pressed steel frame of profile size 105 X 60 mm for door with one or more rebate, made of 1.25 mm thick M S sheet, including necessary fixing lugs, hinges, locks strike plate etc complete all as specified and as directed |
| 35 | M&L for cement concrete (1:3:6) type C-0 using 12.50mm graded crushed stone aggregate as in hold fast and filling of pressed steel chowkat etc complete all as specified and as directed |
| 36 | M&L for Mild steel framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290 Gde E-165 including dismantling the existing mild steel works etc complete all as specified and as directed |
| 37 | S&F Flush door shutter 35mm thick, solid core construction with decorative choice lamination both sides of shutter, kiln seasoned and chemically pressure treated complete all as specified and as directed |
| 38 | M & L for Second class hardwood Glazed and skeleton shutters 35 mm thick, open rebated and prepared to receive glass, gauze, etc. (without sash bars), edges of framing plain, chamfered or rounded. fitted with cut and mitred beads for securing glass, etc.; sizes of me-mbers of shutters as specified in SSR Part I, Section 8, clause 8.24 (a); supplied and fitted to chowkats complete all as specified and as directed |
| 39 | S&F Stainless steel wire cloth 0.36 mm nominal dia of wire and average width of aperature 1.40 mm and fixed with stainles steel wire stapel etc complete all as secified and as directed |
| 40 | S & F in repairs Prelaminated particle board 18/19mm thick, exterior grade, prelaminated one side with decorative choice lamination & other side balancing white lamination, fixed with screws to timber frame work, fixed in kitchen Cabinet or cupboards all as specified & as diercted |
| 41 | M&L for second class hard wood plain fillets square, rectangular or triangular in section clean sawn , secured with nails or brads of fixed to cupboard shutter not exceeding 6 sqcm cross section area including dismantling the existing all as specified and directed. |
| 42 | M&L for second class hard wood plain fillets square, rectangular or triangular in section clean sawn , secured with nails or brads fixed to cupboard shutter exc 6 sqcm but not exc 13 sqcm cross section area including dismantling the existing all as specified and directed. |
| 43 | S & F in repairs cupboard knobs 40 mm dia brass polished, fixed with nut, screw and washer complete all as specified and as directed. |
| 44 | S & F in repairs Continuous (piano) hinges, 30 mm width of flap (when open), mild steel, bright finish or electro galvanised etc complete all as specified and as directed |
| 45 | S & F Solid PVC frame (Single Rebated) of size 60mm x 30mm made out of solid PVC foam with homogenous fine cellular structure having smooth outer integral skin with suitable metal stiffner and fixed with 100 x 8 sheet metal CSK screws complete all as specified and as directed.(Note :- Door frame shall be water proof, termite proof, elegant andshould have excellent screws holding strength to fix hinges and hold doors properly for a long life) |
| 46 | S&F factory made solid PVC moulded door shutter 28 to 30mm thick (Stiles) with wood free EPS, with 2, 4 or 6 raised panel design with 2mm thick moulded prelam PVC sheet on the front face and 2mm plain colour PVC sheet on back face etc. complete all as specified and as directed. Please Enable Macros to View BoQ information |
| 47 | S&F factory made solid PVC moulded door shutter 28 to 30mm thick (Stiles) with wood free EPS, with 2, 4 or 6 raised panel design with 2mm thick moulded prelam PVC sheet on the front face and 2mm plain colour PVC sheet on back face etc. complete all as specified and as directed. Please Enable Macros to View BoQ information |