| 1 | Taking down cement plaster on brick or stone walls, etc including raking out joints, hacking for key, scrubbing down with water, etc. complete including removal of debris to a distance exc 1.5 Km but n exc 2 Km, Complete all as specified. |
| 2 | M&L for 15mm thick rendering on fair faces to brick work or stone masonry surface in Cement mortar 1:6 finished the surface even and smooth (without using extra cement on internal wall surface, complete all as specified. |
| 3 | M&L for 15mm thick rendering on fair faces to brick work or stone masonry surface in Cement mortar 1:4 finished the surface even and smooth without using extra cement on external wall surface, complete all as specified. |
| 4 | Taking down cement plaster / decayed concrete from RCC roof projections / upward parapet walls / down facia / soffits and fins of RCC chajjas / beams / columns / balconies etc. and supply & fixing by means of nailing wire netting of galvanised wire 1.40 mm dia and mesh size 20 mm and brushing neat cement slury with 3.00 Kg of cement / sqm and M&L for 20 mm thick cement rendering in two layers of 10 mm each (top / final layer shall be rendered after final setting of under layer) in CM 1:3 on concrete surfaces including scaffolding at a height upto 7.00 meters etc, Complete all as specified. |
| 5 | Preparing of new plastered wall surface and applying two coat oil bound distemper on newly plastered surfaces, complete all as specified. |
| 6 | Preparing of new plastered surface and applying two coat cement base paint on newly plastered surfaces, complete all as specified |
| 7 | Demolition of cement concrete (unreinforced) in ground floors and pavings n exc 15 cm thickness (below or above ground level), including removal of debris to a distance exc 1.5 Km but n exc. 2 Km, complete all as specified. |
| 8 | M&L for plain cement concrete 1:2:4, type B1 (Using 20 mm graded crushed stone aggragate) as in lintels upto 1.5m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and holdfast and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, kerbs not provided for in Item 04028, water troughs and the like including weathering, slightly rounded or chamfered angles, throating and necessary formwork all as specified and directed. |
| 9 | M&:L for Plain cement concrete M-10, nominal mix, type C-2, using 20mm graded mechanically crushed stone aggregate, 50mm thick as in plinth protection etc., surface finished even and smooth without using extra cement and laid to a slope of 1 in 24 in alternate panels n.exc. 1.20 Sqm each, 12mm wide and 5 cms deep joints shall be formed between the bays and shall be filled with mastic filling comprising a mixture, all as specified and directed by Engg-In-charge. |
| 10 | S&F Mild steel framed work such as grills, gratings, etc..with ends of bars shouldered and/or riveted or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165 all as specified and directed by Engg-In-charge. |
| 11 | Dismantling plain or corrugated steel sheeting any gauge thickness including Nanital or similar pattern roof covering, complete all as specified and direted. |
| 12 | S&F for Galvanised, corrugated mild steel sheeting with two corrugations side lap, fixed with 'L' type or 'J' type hooks with grade of zinc coating 275 of 0.63mm thickness, complete all as specified and direted. |
| 13 | All as per ser item No 12, above but except sheeting any thickness, complete all as specified and direted. |
| 14 | S&F for Plain, galvanised, mild steel sheeting, in ridges, hips and straight flashings (length and girth as fixed) with grade of zinc coating 275 gm of 0.80 mm thickness, complete all as specified and direted. |
| 15 | All as per ser item No 13, above but except sheeting any thickness, complete all as specified. |
| 16 | S&F for Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws, complete all as specified and direted. |
| 17 | S&F for Pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws, complete all as specified and direted. |
| 18 | Preparation of new steel and iron surfaces of any description over 10 CM width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer all as specified and directed. |
| 19 | Dismantling of wall and ceiling boards (fibre, pulp, insulation, etc.) or insulation boards/slabs/blankets, any thickness, including cover fillets etc. complete all as specified. |
| 20 | S&F false ceiling of Non asbestos (Designer) 4 mm thick fibre cement building boards, manufactured from homogeneous mixture of cement, quartz and cellulose and cured with high pressure steam using auto claving process confirming to IS-14862, of size 600 mm x 600 mm x 4 mm thick fixed over and including anodised GI powder coated (minimum thickness of powder coating 50 micron) snap grid frame work of T section (main & cross member) of size 25 mm x 25 mm x 1.5 mm thick in square pattern of grid size 600mm X 600mm . The aluminium fram work will supported on side wall with the used of aluminium 'L' section of size 25 mm x 25 mm x 1.5 angles etc. Snap grid shall be supported with hangers of 4 mm dia Galvanised iron wire adjusting level fixed to roof slabs / truss etc by means of ceiling cleats made out of Galvanised iron flat of size 40 x 3 mm size 60 mm long and expansion hold fasteners 12.5 mm dia 40 mm long complete all as specified directed by the Engineer-in-Charge. Make : Everest or equivalent as approved by GE. |
| 21 | Demolition of stone/boulders or brick masonary built in cment mortor including all quoins, arches, pillars, etc but excluding ashlar facings, dresses stone work and precast concrete articles etc, complete all as specified. |
| 22 | M&L Walling of random rubble, uncoursed, well bonded, bedded and solidly hearted built in cement mortar 1:4 brought up to course complete all as specified and directed. |
| 23 | All as per Item No. 22 but except stone |
| 24 | M&L for Brickwork with old size fly ash bricks, straight or curved on plan exc 6m mean radius, built in cement mortar 1:4, complete all as specified and directed. |
| 25 | M&L for Brickwork with old size flyash bricks, straight or curved on plan to any radius in half brick thick walls, built in CM 1: 4 complete all as specified and directed. |
| 26 | Taking down water tank staging/monkey casing for 500 litre to 1000 litre water tank and refixing the same in same position after completion of roof treatment including necessary repairs/welding if required, complete all as directed by Engr-In-Charge and as specified. |
| 27 | Taking down water tank exc 500 litrs & n exc 1000 ltrs capacity & removing to store, complete all as specified. |
| 28 | S&F for Rotational moulded polyethylene water storage tank 500 Ltrs capacity four layered (ISI Marked) cylinderical vertical with closed top, hoisted and fixed in position with ball brass valve, high pressure with Brass PVC float valve 20mm dia with polythene float and fly nut, tank nipples with check nuts and washers complete and making connections with existing water supply line, all as specified. |
| 29 | S&F for Rotational moulded polyethylene water storage tank 1000 Ltrs capacity four layered (ISI Marked) cylinderical vertical with closed top, hoisted and fixed in position with ball brass valve, high pressure with Brass PVC float valve 20mm dia with polythene float and fly nut, tank nipples with check nuts and washers complete and making connections with existing water supply line, all as specified. |
| 30 | Cleaning and removing all scale and dirt from mouths of circulating pipes etc, from existing water tank capacity ecx 500 & n exc 1000 litrs, setting aside or lowering if required tanks and hoisting in existing position, complete all as specified. |
| 31 | S&F in repair 20 mm ball valves high pressure of PTMT with epoxy coated aluminium rod & high density plastic ball screwed for iron pipe and fixed. (Minimum weight 15 mm - 142 gms/ 20 mm - 210 gms / 25 mm - 455 gms / 40 mm - 690 gms), complete all as specified. |
| 32 | Taking up or down old 15 mm bore steel tubing fixed to wall and ceiling or laid in floor,with all fittings and fixtures and short lengths including cleaning for refixing, removal to store,complete all as specifed . |
| 33 | Taking up or down old 20mm bore steel tubing fixed to wall and ceiling or laid in floor,with all fittings and fixtures and short lengths including cleaning for refixing or removal to store,complete all as specifed . |
| 34 | Taking up or down old 25 to 32 mm bore steel tubing fixed to wall and ceiling or laid in floor,with all fittings and fixtures and short lengths including cleaning for refixing or removal to store,complete all as specifed . |
| 35 | S&F for steel water tubing, 15 mm bore, galvanised, \\" medium grade\\" with all fittings and fixtures and short lengths, fixed to wall and ceiling or laid in floor, complete all as specifed |
| 36 | All as per item No. 35, above but except GI tubing, complete all as specified. |
| 37 | S&F for steel water tubing, 20 mm bore, galvanised, \\" medium grade\\" with all fittings and fixtures and short lengths, fixed to wall and ceiling or laid in floor, complete all as specifed |
| 38 | All as per item No. 37, above but except GI tubing, complete all as specified. |
| 39 | S&F for steel water tubing, 25 mm bore, galvanised, \\" medium grade\\" with all fittings and fixtures and short lengths, fixed to wall and ceiling or laid in floor, complete all as specified |
| 40 | S&F 32mm bore medium grade glavanised tubes with all fittings and fixed complete to walls etc. incl taking down all as specified. |
| 41 | All as per item No. 40, above but except GI tubing, complete all as specified. |
| 42 | S&F 15 mm Tank Nipple PTMT suitable for HDPE water tank (Minimum weight 15 mm-38 gms/20 mm-45 gms/25 mm-65 gms) complete all as specified and as directed |
| 43 | S&F 20 mm Tank Nipple PTMT suitable for HDPE water tank (Minimum weight 15 mm-38 gms/20 mm-45 gms/25 mm-65 gms) complete all as specified and as directed |
| 44 | S&F 32 mm Tank Nipple PTMT suitable for HDPE water tank (Minimum weight 15 mm-38 gms/20 mm-45 gms/25 mm-65 gms) complete all as specified and as directed |
| 45 | Demolition of existing treatment on roof slab, taking down cement plaster including existing tarfelt from roof surfaces by brushing with wire brushes for removing caked etc sweeping with brooms and finally fanning the cleaned surface to remove all loose dirt etc, complete all as specified and directed by Engg-In-Charge. |
| 46 | M&L for 15mm thick rendering on Concrete surface in cement mortar 1:4 finished the surface even and smooth without using extra cement on external wall surface using water proofing compound @ 3% by weight of cement or as per manufacturers instructions, complete all as specified. |
| 47 | Supply only integral water proofing compound |
| 48 | Water proofing treatment of roof portion using shaliurethane-BTD of STP make or equivalent mentioned in Appendix 'C' high solid content component Water basedliquid applied elastometric water proofing membrane as ASTMC 836 and ASTMD 6083, thickness of the membrane shall be 1.50 mm having solid content of more than 80 % elongation of 500 + (-) 50 % laid over reinforcing layer on non woven geotextile mesh of 40/50 gms including applying self primer coat by diluting with 1:1 ratio @ 0.20 Kg per square metre and surface preparation, complete all as per manufacturer's instructions/ specifications and as directed. |
| 49 | Demolition of existing treatment on roof slab by taking down cement plaster including existing tarfelt from roof surfaces by brushing with wire brushes for removing caked etc sweeping with brooms and finally fanning the cleaned surface to remove all loose dirt etc on roof and applying the following :-(a) 15mm thick rendering in cement mortar 1:4 mixed with WPC @ 3% by weight of cement or as per manufacturers instructions, finished surface even & smooth without using extra cement.(b) FIRST COURSE : One coat of bitumen primer confirming to IS -3384 @ 0.40 Kg/Sqm.(c) SECOND COURSE : One coat of bonding material using blown type bitumen confirming to IS - 702 grade 85/25 @ 1.20 Kg/qm. (d) THIRD COURSE : A layer of APP modified polymeric membrane, Centre core of 100 mm micron HMHDPE, outer film 20 micron each, thickness 3 mm, having wieght 2.25 Kg/Sqm, complete all as specified. |
| 50 | Preparation of newly APP membrane surface and applying one coat of aluminium paint over APP membrance, complete all as specified. |
| 51 | Dismantling timber scantlings 40 sq. cm and over in section, in any position unframed work complete all as specified. |
| 52 | Mild steel Joist channel, angle or tee section fixed independantly without connection plate etc. (cut to ordinary lengths i.e. within 20mm of the length indicated) conforming to grade Fe.410-0.Gde-E-250 quality A, complete all as specified and directed. |
| 53 | S&F 2nd class hardwood Plain, solid, straight, cupboard chowkats & frames, wrought, framed rebated on the solid, purlin rafter varadah post, rounded or chamfered, put together with glue pinned at joints. Please Enable Macros to View BoQ information |