Sales : +91-777 804 8217
| Sl. No. | Item Description |
| 1 | Providing and laying 60mm thick factory made chamfered edge cement concrete paver block of M-35 grade with approved colour, design & pattern as in footparth, parks, lawns, drive ways or light traffic parking etc., of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over and including 50mm thick compacted bed of fine sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand; including dismantling/taking out unserviceable tiles complete all as specified and as directed. |
| 2 | S&F Steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I.S.1161-1979 grade St.-240 including necessary preperation of surfaces and applying one shop coat of red oxide, zinc chrome primer including dismantling of unserviceable wrought iron and mild steel of any description complete all as specified and as directed. |
| 3 | S&F Prepainted galvalume aluminium zink coating Gl based corrugated/semi corrugated steel sheet 0.50 mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws including dismantling corrugated steel Sheets any gauge, thickness, Nainital or Similar Pattern Roof Coverings complete all as specified and as directed. |
| 4 | Taking down chowkats or frames exc 1.5 Sqm but n.exc 4 Sqm (without taking off shutter from the frame) each including Builders Hardware and removing from the site including dismantling brick work for hold fasts etc complete all as specified and as directed. |
| 5 | Taking down shutters of any description exc 1 Sqm and n.exc 2.00 Sqm each including Builders Hardware and removing from site complete all as specified and as directed. |
| 6 | S&F factory made Pressed steel frames confirming to IS, having profile of size 125 x 60 mm, 1.25 mm thick MS Sheet for doors with one or more rebates including necessary supply and fixing lugs, lock strike plate, etc. 100 mm size hinges, with one shop coat of zinc chromate primer and fixing complete all as specified and as directed. |
| 7 | S&F Solid PVC Door Frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with M.S. Square tube, fixed in opening as specified in SSR Part I, Section 8 complete all as specified and as directed. |
| 8 | S&F factory made pressed steel frames confirming to relevant IS, having profile of size 105 x 60 mm, 1.25 mm thick MS Sheet for doors with one or more rebates including necessary Supply & fixing lugs, lock strike plate, etc. 100 mm size hinges, with one shop coat of zinc chromate primer and fixing complete all as specified and as directed. |
| 9 | S&F factory made 35mm thick 2nd class hard wood factory made, plain, framed, panelled shutter (two panel) with lock rails and panel of 9mm BWP commercial ply or 12 mm thick veneered particle board with commercial veneering on both faces. The size of rail and style as per IS-1003 Part-1 klin seasoned and chamicaly pressure treated complete all as specified and as directed. |
| 10 | S&F factory made 35mm thick 2nd class hard wood gauged and skeleton shutter open rebated and prepared to received gauge etc (without sash bars) for fly proof door shutter, edges of framing plain, chamfered or rounded, fitted with cut of any mitred beads for securing gauge etc, size of members of shutter as specified in SSR-I section 8 clause No. 8.23(a) and fitted to chowkats complete all as specified and as directed. |
| 11 | S&F factory made solid olid panel PVC door shutter 30mm thick (style) consisting of frame made out of MS tubes far top and bottom rails, MS frame shall be covered with heat moulded plain colour PVC \\"C\\" channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail and bottom rail on either side and as gap insert for top rail and bottom rail Paneling of plain colour PVC sheets to be fitted in the MS frame welded/sealed to the stiles and rails with suitable PVC sheet beading and jointed together with solvent cement complete all as specified and as directed. |
| 12 | M&L for resecuring or easing & adjusting without taking down door shutters exc 1 sqm and n.exc 2.00sqm each complete all as specified and as directed. |
| 13 | Refixing of shutter exc 1 Sqm but n. exc 2 Sqm after necessary repairs in the same opening complete all as specified and as directed. |
| 14 | M&L 18-19 mm thick pre laminated partical board, interior grade, prelaminated one side with decorative choice lamination & other side balancing white lamination, fixed with screw to MS frame work complete all as specified and as directed. |
| 15 | S&F 30mm (width of flaps when open) continuous (piano) hinges, mild steel, bright finish or electro galvanised complete all as specified. |
| 16 | S&F 10mm mild steel butt hinges, medium weight cold rolled complete all as specified and as directed |
| 17 | S&F mild steel Hand rails, half round or other steel section or core for wooden hand-rail straight portion, drilled and countersunk for balusters running bars, for doors, balusters, nosing to steps including embeding in concrete and screwing etc. wind ties for roof including securing bolts: posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc., flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc., and similar work conforming to Fe-290 Gde E-165 including dismantling of unserviceable wrought iron and mild steel work of any description complete all as specified and as directed |
| 18 | S&F aluminium handles cast type anodised 150mm of size complete all as specified and as directed. |
| 19 | S&F 150mm long aluminium anodised barrel tower bolt of extruded section complete all as specified and as directed. |
| 20 | S&F 50 mm long Mild steel barrel tower bolts, stove enameled black, with bright bolt complete all as specified and as directed. |
| 21 | S&F 150 mm long Mild steel pressed handle, oval type, stove enamelled black complete all as specified and as directed. |
| 22 | S&F Aluminium alloy anodised sliding door bolt 250 mm long with hasp & staple (bolt type) and fixing clips of sheet cast or extruded section and fhing boits and sliding bolts of extruded section complete all as specified and as directed. |
| 23 | Supply and fixing steel windows with side hung shutters including box type hinges with steel handle, and steel peg stay, including one coat of red oxide primer complete withglazing bars, dovetailed or welded complete all as specified and directed. |
| 24 | All as per item No 23 above but without glazing bars complete all as specified and as directed. |
| 25 | All as per item No 23 above but fixed type complete all as specified and as directed. |
| 26 | S&F in repair steel ventilator top hung shutter including hinges, steel peg stay, fixing lugs etc complete with or without glazing bars complete all as specified and as directed. |
| 27 | M&L mild steel framed work such as grills, gratings, etc. with ends of bars shouldered and/or riveted, or forged into spikes, framed guard 22 bars: barred iron doors; ladders, framed balusters, walk ways: railings; framework of water tanks and similar work conforming to Fe 290 Gde-E-165 complete all as specified and as directed. |
| 28 | M&L preparation of new or previously untreated steel and iron surface of any description, not otherwise described over 10 cm width or girth and applying two coats of synthetic enamel paint over one coat of red oxide primer complete all as specified and as directed. |
| 29 | M&L for preparation of new or previously undecorated wooden surface of any description, not otherwise described over 10 cm width or girth and applying two coats of synthetic enamel paint over one coat of pink primer complete all as specified and as directed. |
| 30 | Hacking out old broken unserviceable glass panes (any thickness, size, quality or description) for metal frame including punching or drilling out old glazing pins/spring clips complete all as specified and as directed. |
| 31 | S&F of 3 mm thick sheet glass, ordinary quality and glazing with oil putty in square n exc 0.5 sqm in each pane complete all as specified and as directed. |
| 32 | M&L for PCC type C-1, 1:3:6 using 20mm graded aggregate as in bed block for fixing of hold fast, filling concrete in pressed steel door frame filling, gaps in between glazed & flyproof steel window, cills, railing up to 60 cm in height etc including necessary form work as required complete all as specified and as directed. |
| 33 | S&F stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples complete all as specified and as directed. |
| 34 | S&F in repair stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples complete all as specified and as directed. |
| 35 | M&L for brick works with fly ash bricks straight or curved on plain exc 6m mean radius built in cement mortar 1:6 including demolition of unserviceable brickwork of any description built in cement mortar complete ail as specified and as directed. |
| 36 | Taking down cement plaster on walls & ceiling of any discription including racking out joints, hacking for key and scrubbing down with water etc including removing debries from the site complete all as specified and as directed. |
| 37 | M&L for 15mm thick rendering in cement mortar (1:4) on fair faces of brick walls or concrete surfaces in two layers (10mm & 5mm) mixed with water proofing compound by weight of cement or as per manufacturer instructions, finished even & smooth without using extra cement all complete all as specified and as directed. Note. Liquid water proofing compound will be measured and paid separtely. |
| 38 | M&L rendering 5 mm thick cement plaster on ceiling cement mortar (1:3) finished even & fair without using extra cement complete all as specified and as directed. |
| 39 | M&L for rendering 15 mm thick cement plaster on other than fair surfaces of brick work in cement mortar (1:6) finished even & fair without using extra cement complete all as specified and as directed. |
| 40 | Supply anly liquid integral water proofing compound complete all as specified and as directed. |
| 41 | M&L. preparation of newly plastered surfaces of wall and applying three coats of white wash on wall to match the existing colour complete all as specified and as directed |
| 42 | M&L preparation of newly plastered ceiling surfaces and applying three coats of white wash complete all as specified and as directed |
| 43 | M&L preparation of newly plaster surface and apply two coat of cement base point over a coat of primer complete all as specified and as directed. |
| 44 | M&L preperation of old surfaces of wall and applying one coat of acrylic based distemper including brooming down or steel wire brushing scrapping down smoke soot, molds, moss and efflorescent sats as directed saits and trading off and greasy spots complete all as specified and |
| 45 | M&L preperation of old surfaces of ceiling and applying one coat of white wash including brooming down or steel wire brushing. scrapping down smoke soot, molds, moss and efflorescent salts and trading oil and greasy spots complete all as specified and as directed |
| 46 | M&L for granite (of any type) tiles 15-18mm thick machine cut, bedded and jointed with grey cement alurry and pointed with white cement with admixture of pigment to match the shade of granite stone including grinding and polishing including 20mm thick backing layer in cement mortar 18 and jointed with grey cement slurry, and pointed with white coment with admixture of pigment to match the shade of granite stone including grinding and polishing including dismantling unserviceable Stone slabs and tiles of any description of thickness in floors, aprons etc. laid bedded and pointed in any cement mortar complete all as specified and as directed. |
| 47 | M&L, for non skid coloured tiles 7 to 8 mm thick(square/rectangular) area of each tiles exc. 11 sqm but not exc 0.18 sqm in floor etc set and jointed in neat cement slury over and including cement screed 15 mm thick 1:6 including taking out unserviceable tiling including cement mortar bedding and removing debrires from the site complete all as specified and as directed. |
| 48 | M&L coloured glazed ceramic tiles 300 x 450 x 7 mm thick in vertical surfaces and jointed in neat cement slurry and pointed in white or coloured cement to match including 10mm thick backing with CM (1:4) including taking out unserviceable wall tiling including cement mortar bedding and removing debrires from the site complete all as specified and as directed. |
| 49 | M&L for non skid coloured tiles 7 to 8 mm thick(square/ rectangular) area of each tiles exc. 18 sqm but not exc 0.36 agm in foor etc set and jointed in neat cement slury over and including cement screed 15 mm thick 1:6 including taking out unserviceable tiling including cement mortar bedding and removing debrires from the site complete all as specified and as directed. |
| 50 | M&L for 75mm thick cement concrete (1:3:6) type C-2( using 40mm graded crushed stone aggregate) as in plinth protection laid in alternate bays (not exceeding 2 Sqm each) and finished even and smooth without using extra cement and providing joints throughout the thickness of the plinth protection filled with mastic filling comprising one part of bitumen 86/25 grade and three parts of sand by weight complete all as specified and as directed. |
| 51 | Taking up or down steel tubing and connections, including cleaning for refixing or removal to store of 15 mm bore complete all as specified and as directed. |
| 52 | S&F 15mm bore Gl pipe medium grade water tube with all fitings laid in floors fxed to walls and cellings or laid in floors complete all as specified and as directed. |
| 53 | Refixing old serviceable steel tubing in new or old position (wall, ceiling & floor) of 15mm bore with necessary GI (medium grade) fittings complete all as specified and as directed.Note: Serviceable pipe obtained from item No. 51 here-in-before including necessary cleaning of pipe id deemed to be inclusive in the unit rate quoted. |
| 54 | Cutting chases in walls for taking out concealed 15mm bore Gl pipe to the required sizes and making good the same after relaying/refixing Gt pipe in cement mortar 1:3 to match with adjoining surfaces complete all as specified and as directed.Note:- Taking out Gl pipe and providing new pipes shall be measured and paid seperately under appropiate items |
| 55 | Taking up or down steel tubing and connections, including cleaning for refixing or removal to store of 20 mm bore complete all as specified and as directed. |
| 56 | S&F 15mm bore GI pipe medium grade water tube with all fittings laid in floors fixed to walls and ceilings or laid in floors complete all as specified and as directed |
| 57 | Supplying & fixing of PVC water storage tank 500 ltr capacity HDPE double layered, cylindrical type fixed and hoisted in position on roof at any height complete with inlet/outlet of 20 mm GI Pipe connection including locking arrangement, including supplying & fixing of Ball valves high pressure of PTMT with epoxy coated Aluminium rod & high density plastic ball screwed for iron pipe 20 mm dia and (Minimum weight 20 mm - 210 gms) complete all as specified and as directed.Note : GI inlet, outlet & wash out pipe will be measured and paid separately. |
| 58 | S&F in repair vitreous china wash basin, white, flat back of size 550x 400 mm including cutting for and pining, in ends of brackets or erecting stand, including PVC connection 15mm size with PTMT nuts, 450mm length and 32mm bore 900mm long corrugated waste pipe complete all as specified and as directed. |
| 59 | S&F in repair 600x450mm bevelled edge mirror of seicted quality glass, mounted on 6mm thick AC building plywood and fixed to wooden plugs with chromium plated brass screws and cup washers all as specified complete all as specified and as ing board or commercial directed. |
| 60 | S&F vitreous China squatting pan Orissa\\" pattem size 580x440mm white with integral foot rests (excluding flushing cistern and flush pipe) with 'P' or 'S\\" trap from or back inlet etc including connection to trap and flushing pipe and provision of 100mm thick cement concrete using type E2 1:5:10 bedding debries of the site including dermoliation of existing unserviceable squatting pan including concrete and removing debries of the site complete all as specified and as directed. |
| 61 | S&F in repair 10 Itrs capacity low level valve less PVC syphonic action type flushing cistern white with in let ball valve float and handle, PVC flush pipe, complete all as specified and as directed. |
| 62 | S&F in repair Vitreous China, pedestal pattern white (excluding fixing bolts, flushing cistem and flush pipe) including Plastic water closet seat, black, closed pattern with flat bottom, and cover and mild steel chromium plated or aluminised hinging device complete all as specified and as directed. |
| 63 | S & F in repair grating doom 125mm dia with waste hole of PTMT (min weight 40 gms) complete all as specified and as directed. |
| 64 | S&F in repair 75 mm PVC (SWR) floor trap, plain with grating including jointing with solvent cement complete all as specified and as directed. |
| 65 | S&F in repair 110mm dia PVC SWR pipes single socketed in any length with rubber ring joints, fixed to wall complete all as specified and as directed. |
| 66 | S&F in repair 110mm dia PVC SWR bends of any radius with out access door complete all as specified and as directed. |
| 67 | S&F in repair 110mm dia PVC (SWR) junction single 'T' equal or unequal with access door complete all as specified and as directed. |
| 68 | S&F in repair 110mm dia PVC (SWR) branch piece, single 'Y' equal or unequal complete all as specified and as directed. |
| 69 | M&L RCC (nominal mix) using type B1 (1:2:4) using 20 mm graded aggregate as in fins, fascias, louvres, parapets, and railings exc. 60cm in height, newels, balustrade balustrade, and the likeincluding demolition of existing unserviceable reinforced concrete of any description complete all as specified and as directed. |
| 70 | Use and waste of formwork to fins, louvers, fascia. etc Fair finished surfaces of concrete flat complete all as specified and as directed |
| 71 | M&L Mild steel TMT bars 6mm to 8mm dia, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends & binding with & including mild steel wire (annealed) not less than 0.9mndia or securing with clips quality complete all as specified and as directed. |
| 72 | S&F in repair of ball valves of 20mm bore high pressure of PTMT with epoxy coated aluminium rod and high density plastic ball screwed for iron pipe & fixed (minimum weight 20gms-210 gms) complete all as specified and as directed. |
| 73 | S&F in repairs 15mm dia Bib taps, cast copper alloy with crutch or butterfuly handle, screwed down, screwed for iron pipe or for brass ferrule and foxed complete all as specified and as directed. |
| 74 | S&F in repair 15mm concealed stop cock CP, cast copper alloy fancy type with long shank and cup complete al as specified and as directed. |
| 75 | S&F in repair 15mm bore stop cock of PTMT any colour high pressure screwed for iron pipe and fixed. (minimum weight 15mm-90gms) complete all as specified and as directed. |
| 76 | S&F in repair of chromium plated shower roses with or without swivel joints, any size, including foxing to steel pipe or union complete all as specified and as directed. |
| 77 | S&F in repairs 15mm bore pillar taps, capstan head, cast copper alloy, chromiurn plated, screwed down high pressure with or without lettered \\"HOT or \\"COLD' long screwed shanks and fly nuts, screwed for iron pipe complete all as specified and as directed. |
| 78 | S&F in repair health faucet connecting with 15mm dia pipe with chromium plated (CP) finishing 1.5 mtr long etc complete all as specified and as directed |
| 79 | S&F in repair 15mm dia brass chromium plated angle cock complete all as specified and as directed. |
| 80 | ELECTRIFICATIONTaking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, celling roses, pendants, regulators, sockets, light fitting etc and making good disturbed surfaces of walls, floors, etc as per existing specification after providing point wiring under respective items here-in-below complete all as specified and as directed. |
| 81 | Taking down carefully existing old/unserviceable sub main winng of any size/description as existing at the the site including making good the disturbed surfaces of wall/celling so as to match with the existing finishes complete all as specified and as directed. |
| 82 | M&L for concealed point wiring for one light point controlled by one, one way switch complete with 1.5 Sqmm multistranded copper conductor single core PVC insulated unsheathed FR-LSH cable 1100 volts grade (151 marked) with proper and including non-metallic rigid PVC medium grade conduit not less that 20mm dia and conduit accessories (ISI marked) concealed in h proper colour coding drawn through wall/fixed to roof, celling etc including provision of 1.5 Sqmm PVC insulated multistranded unsheathed copper conductor cable FR-LSH (ISI marked) as earth continuity conductor connected to common earth dolly, fabricated suken terminal box made out of MS sheet steel not less than 1.22 mm thick of required size duly painted with aluminum inside and anticorrosive paint outside, (clear depth of the box not less than 60mm and this shall be increased suitably to accomadiate flush type regulators) concealed in walls, with 3mm thick bakelite/plastic laminated sheet top cover fixed with cadmium plated iron screws for housing switches, socket outlets, fan regulators etc duly earthed.Note:- (i) Where concealing of conduit is not feasible on surface of cailing/ roof etc, conduit shall be fixed on surface with necessary saddles at no extra cost.(ii) Connections of cable with MCBs or bus bar shall be sone through proper size of copper/brass thimbles. |
| 83 | All as per item No 82 above, but for one Ceiling Fan / exhaust fan point controlled by one, one way switch and regulator complete all as specified and as directed. |
| 84 | All as per item No 82 above, but for one 3 point 5 Amps switch socket outlet point controlled by one switch on the same board complete all as specified and as directed. |
| 85 | All as per item No 82 above, but for one 3 pin 5 Amps switch socket outlet point controlled by one switch on independent board complete all as specified and as directed. |
| 86 | All as per item No 82 above, but for one bell point controlled by one, bell switch 5 Armps complete all as specified and as directed. |
| 87 | All as per item No 82 above, but using 2.5 sq mm single core copper conductor cable of multistranded flame retardant PVC insulated unsheathed 1100 volts grade for 5/15 amps switch socket combination point including ruining of 2.5 sq mm copper conductor FRLSH PVC wire as earth continuity conductor along with wiring and connecting to the common earth dolly, complete all as specified and as directed. |
| 88 | S&F switch piano single pole flush type 5 amps, 230 volts one way complete all as specified and as directed |
| 89 | S&F bell push flush type 5 amps, 230 volts. complete all as specified and as directed. |
| 90 | S&F socket outlet 2 in 1, 5 Pin, 5/6 amps, white ivory finish flash type complete all as specified and as directed. |
| 91 | S&F socket outlet 2 in 1. 5 Pin, 5/15 amps, white Ivory finish flash type complete all as specified and as directed. |
| 92 | S&Fswitch piano single pole flush type 15 amps, 230 volts one way complete all as specified and as directed. |
| 93 | S&F Switch socket combination 2 and 3 Pin, 5/6 amps, multipurpose flush non shutter, non inter locking type white ivory finish complete all as specified and as directed. |
| 94 | S&F of socket outlet 2 in 1, 5 Pin 5/15 Amp multipurpose 230 volt flush type complete all as specified and as directed |
| 95 | S&F ceiling rose, bakelite, surface type, 220/240 volts, three terminals complete all as specified and as directed. |
| 96 | S&F lamp holder, insulated body, with back plate suitable for batten/angle fittings complete all as specified and as directed. |
| 97 | S&F Call bell Ding dong. 230 Volt single phase complete all as specified and as directed. |
| 98 | S&F deluxe fan Electronic regulator 120/280 volts AC 50 Hz rotary step white/ivory finish complete all as specified and as directed. |
| 99 | S&F in replacement hylam sheet 3 mm thick white in colour of size 130 mm x 180 mm including taking down existing unserviceable complete all as specified and as directed. |
| 100 | S&F in replacement hylam sheet 3 mm thick white in colour of size 120 mm x 170 mm including taking down existing unserviceable complete all as specified and as directed. |
| 101 | S&F in replacement hylam sheet 3 mm thick white in colour of size 230 mm x 280 mm including taking down existing unserviceable complete all as specified and as directed. |
| 102 | S&F in replacement hylam sheet 3 mm thick white in colour round type of size 80 mm dia including taking down existing unserviceable complete all as specified and as directed. |
| 103 | S&F in replacernent LED tube light 1 X 20 W (or nearest next higher wattage) (4feet), 5700K, wall surface mounted, integrated type with aluminium housing and decorative and caps with integrated high efficiency electronic driver and surge suppressor of 2KV or more. luminaire efficiency > 95 lumens/watt, power factor > 0.90, operating range 140 to 270 V, 50 Hz fixed with 02 Nos of PVC round/square blocks, screws etc complete with all accessories internally prewired and connecting up with three core flexible copper conductor cable of suitable size from ceiling rose with connector block. including necessary taking down the old unserviceable fitting complete all as specified and as directed. |
| 104 | S&F in replacement Inverter retrofit tube light of 20W with square profile and polycarbonate channel, lithium Ion battery with charging time 8 Hours-10 Hours and backup time upto 4 Hours with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose including taking down/dismantling of old existing unserviceable one complete all as specified and as directed. |
| 105 | S&F in replacement energy saving & environment friendly long life 25 Watt, (or nearest next higher wattage) CT ≥ 5700 K, LED building security light made up of pressure die-cast aluminium housing with acrylic cover as diffuser with IP 66 protection & impact resistance not less than IK-07 complete with integrated type, with high efficiency electronic driver, surge suppressor of 5 KV or more & high brightness LEDs, luminaire efficacy 110 lumens/Watt, power factor ≥ 0.90, operating range 140 to 270 V, 50 Hz complete and connecting up with and including three core twisted flexible copper conductor cable of suitable size all as specified & as directed. |
| 106 | S&F in replacement Post top lanterns 15 watt (or nearest next higher wattage) LED light fitting new generation, energy saving, environmental friendly, longlife with symmetrical light distribution, spun aluminium landscape luminaire with high power LEDs as light source, spun aluminium canopy, with opal/clear acrylic diffuser and complete with all accessories internally prewired including connecting up with three core twisted flexible copper conductor cable and necessary mounting arrangements, including taking down/dismantling of old existing unserviceable one complete all as specified and as directed. |
| 107 | M&L, concealed sub-main wiring alongwith earth wire of size of 2 x 6.0 sq. mm + 1 x 6.0 sq. mm earth wire, ISI marked, FRLSH, PVC insulated, multi stranded, copper conductor, single core cable drawn through and including PVC rigid conduit (medium grade) of suitable size with all fittings and accessories ISI marked complete all as specified and as directed.NOTE:(i) Two runs of PVC wire, one run of earth wire & one run of PVC Conduit will be measured as one length. (ii) Cost of cutting chases and making good the distrubed surfaces is deemed to be inclusive in the unit rate quoted. |
| 108 | M&L concealed sub-main wiring alongwith earth wire of size of 2 x 4.0 sq. mm + 1 x 4.0 sq mm earth wire, ISI marked, FRLSH, PVC insulated, multi stranded, copper conductor, single core cable drawn through and including PVC rigid conduit (medium grade) of suitable size with all fittings and accessories ISI marked complete all as specified and as directed.NOTE: (i) Two runs of PVC wire, one run of earth wire & one run of PVC Conduit will be measured as one length. (ii) Cost of cutting chases and making good the distrubed surfaces is deemed to be inclusive in the unit rate quoted. |
| 109 | M&L, in replacement for sheet metal enclosure fabricated out of 2.0 mm thick CRCA sheet, totally enclosed type, dust & vermin proof, with suitable sized supporting MS angles & suitable openings at top & bottom for entry of outgoing/incoming cables, fixed with nuts & bolts & front side openable with hinged shutter with suitable locking arrangement duly painted with 2 coats of powder coated paint over a coat of red oxide primer (spray paint) with minimum dimensions (90 x 75 x 20 cm) flush to wall for incorporating 01 No TPN DB, 04 Nos electronic meters etc including taking down/dismantling of old existing unserviceable one complete all as specified and as directed. |
| 110 | S&F Sheet metal enclosure for 4 way Distribution Boards (DB’s), double door, Triple pole & neutral with 200 amps rated bus bar, IP-20 protection suitable for fixing MCB\\"S/isolators complete with and including taking down old unserviceable one all as specified and directed including taking down the existing unserviceable main switch/ cut out/ DBs of any type/ capacity/ description as existing at site including making good the disturbed surfaces to match with the existing finishes complete all as specified and as directed. |
| 111 | S&F Sheet metal enclosure for 8 way Distribution Boards (DB’s), double door, single pole & neutral with 200 amps rated bus bar, IP-20 protection suitable for fixing MCB\\"S/isolators complete with and including taking down old unserviceable one all as specified and directed including taking down the existing unserviceable main switch/ cut out/ DBs of any type/ capacity/ description as existing at site including making good the disturbed surfaces to match with the existing finishes complete all as specified and as directed. |
| 112 | S&F in repair MCB, Triple pole & neutral 63 amps, 240 volts, 'C' curve. 10KA complete all as specified and as directed. |
| 113 | S&F in repair MCB, Single pole & neutral, 32 to 63 amps, 240 volts, 'C' curve, 10KA all complete with complete all as specified and as directed. |
| 114 | S&F in repair MCB, Single pole, 5 to 32 amps, 240 volts, 'C' curve, 10 KA all complete all as specified and as directed. |
| 115 | M&L earthing complete with galvanized steel earth plate electrode 600 mm x 600 mm x 6 mm thick buried directly in ground (earth pit not less than 2.25 meter deep below ground level) with top edge of plate not less than 1.5 meter below normal ground level, connected to galvanized iron earth lead wire of 4 sqmm by means of bolts, nuts, check nuts and washers of galvanized iron or steel, all as shown in Electrical Plate No 3 of SSR Part-1, including necessary excavation and earth work, P.C.C (1:3.6) type C-1 with 50 mm thick Pre-cast R.C.C. (1:2:4) type B-l cover slab (reinforced with 8 mm dia deformed bar @ 15 cm C/C both ways and suitable handle of 10 mm dia round bar), including providing charcoal or coke and common salt in alternate layers of 15 cm compacted thickness all around the earth electrode, with funnel and 20 mm bore galvanized iron watering pipe (light grade), wire mesh, aluminium lugs, complete in all respect, Gi earth wire protected by 15 mm bore (medium grade) galvanized iron pipe and other end connected with main switch board or Earthing test point as directed, including necessary earth work and disposal of spoil to a distance not exceeding 50 metre and necessary testing on completion including dismentaling old unserviceable ones complete all as specified and as directed. Please Enable Macros to View BoQ information |