| 1 | Supply of MS Bend 75mm |
| 2 | Providing & fixing of M.S. Bend with required nut bolts & packing sheet etc. complete as required of dia 100 mm short bend C-class |
| 3 | Replacement of swing type Non Return valve of CI body with door, bronze to rubber rings confirming to IS 5312 (part 1 & 2), PN 1.6 complete as required of size 150mm |
| 4 | Supply of CI nipple 75 mm |
| 5 | Supply of CI nipple 100 mm |
| 6 | Supply of CI nipple 150 mm |
| 7 | Old Dhoti |
| 8 | Nut-bolt set with washer, 4 soot - 4 inch long |
| 9 | Nut-bolt set with washer, 3 soot - 4 inch long |
| 10 | Nut-bolt set with washer, 4 soot - 3 inch long |
| 11 | Nut-bolt set with washer, 2.5 soot - 3 inch long |
| 12 | Nut-bolt set with washer, 4 soot - 5 inch long |
| 13 | Nut-bolt set with washer, 1.5 soot - 2.5 inch long |
| 14 | Couple Tyre 13 no. |
| 15 | Couple Tyre 14 no. |
| 16 | Coupling plate set along with studs, size 13 nos. |
| 17 | Supply of gland plate for kirloskar make SHM 100/26 pump set |
| 18 | Supply of gland plate for kirloskar make SHM 150/26 pump set |
| 19 | Supply of gland 12mm |
| 20 | Supply of gland 10mm |
| 21 | Providing of Kirloskar care premium Oil 20 ltr can (82.060.10.0.20) for KG 125 WS -3 125 KVA |
| 22 | S & F following size of G.I. Socket. as reqd. 80 mm |
| 23 | S & F following size of G.I. Socket. as reqd. 100 mm |
| 24 | S & F following size of G.I. Socket. as reqd. 150 mm |
| 25 | Supply of Starting Handle required for 6.0/12.0/32.0 BHP Engines. |
| 26 | Supply of Lead acid Batteries for the DG Sets/ Diesel Engine pump sets |
| 27 | Supply of Mannually operated pump for diesel refilling having min. 4 feet long pipe, handle, etc. with complete OEM accessories |
| 28 | Supply of PVC garden pipe size 25 mm |
| 29 | Providing and fixing of Space Heater with thermostate including controlling switch to maintaining the penal moisture free |
| 30 | Supplying, installation, Testing & Commissioning of LED surface mounted Batten light of following body material and construction as per IS : 10322 with driver (Replaceable) as per the requirement with Driver efficiency >85% ,Operating voltage AC 140-270 Volt, freq 50/60 hz, Operating temp range -15 deg to 40 deg centigrade, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, IP20, CRI >80 , Flicker free (flicker should be below 5 %), life time (LED,Driver & electrical circuitry),of minimum 50000 Burning Hours with , 70% of initial Lumen maintained till life ends, CCT 3000°K / 4000°K / 5700°K /6000°K/ 6500°K (As per ANSI Bin), SDCM (Standard Deviation Color Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard and trade mark certificate (T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. complete in all respect i/c connections with 1.5 sq mm FRLS, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy >135 lm/Watt output . LM79 & LM80 Test report from NABL lab for all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineerin-Charge as per requirement. (Thermal management: heat sink of aluminum housing such that LED junction temperature shall not rise above 90°C). Powder coated die cast /Extruded aluminum Body (Thickness ≥ 1.20 mm) 18-22 watt |
| 31 | P/f of Hot press sheed moulded compound (SMC) Fireretardant (Temp. resistance up to 200 C), IP 55 weather proof pole box of inner dimension 200xl60x98mm (NS) complete with suitable arrangement for fixing of 2 nos of 6 to 32 amp single pole MCB & 63 Amp. Double pole isolator (MCB/lsolator excluded) with neutral link duly shorting on DIN Channel with2 Nos of MS clamps with 55 back plate of suitable size with danger monogram property printed on the cover etc as reqd. as reqd. |
| 32 | Supplying, installation, Testing & Commissioning of Flood Light, powder coated pressure die cast aluminum body with built in or separate driver as per the requirement with Driver efficiency >85%, Input voltage: Input voltage: 140-270 Volt AC, freq 50/60 hz, Operating temp range -15 deg to 50 deg centigrade, internal surge protection of 5 KV L,N,E as per IEC 61000-4- 5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2 , P. F.≥0.95, IP66,IK-10, CRI >80 , under voltage and over voltage protection, EMIEMC as per CISPR -15 , lenses for beam angle 30 deg-120deg as per the application and the project requirement deg., suitable tilt able fitting, life time (LED,Driver & electrical circuitary) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin) , SDCM(Standard Deviation Color Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c connections with 1.5 sq mm FRLS, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy 105 <120 lm/Watt output . LM79 & LM80 Test report from NABL lab for all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-inCharge as per requirement. (Thermal management: heat sink of aluminum housing such that LED junction temperature shall not rise above90°C). 70 Watt |
| 33 | Brush Less DIrect Current (BLDC) MotorSupply, Installation, Testing and Commissioning of ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. metal( Aluminum alloy) blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, steel/Al bodyPower Factor not less than 0.9, Service Value (CM/M/W) minimum as below, 350 RPM (tolerance as per IS : 374- 2019), THD (Total Harmonic Distortion) less than 10%, remote (prefreably mobile app based) for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Ceiling Fan compliant to IS 374:2019 fan Supply, earthing etc.complete as req.1400mm, service value ≥ 6.0 CM/Min/Watt, air delivery 245 CM/Min (Minimum) |
| 34 | Providing and fixing of 600 mm sweep Air circulater complete with blades, jaal workable on 220/240 volts AC supply etc as reqd. |
| 35 | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade of 3.5X400 sq. mm (82 mm) |
| 36 | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade of 3.5X120 sq. mm (45 mm) |
| 37 | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade of 3.5X95 sq. mm (45 mm) |
| 38 | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 3.5X50 Sq. mm(28) Please Enable Macros to View BoQ information |