| 1 | Demolition of brick work stone/boulder masonry built in cement mortar including all quoins, arches, pillars etc, complete all as specified and directed. |
| 2 | M&L for Brick work with sub class 'B' bricks, straight or curved on plan exc 6m mean radius built in CM 1:4, complete all as specified and directed. |
| 3 | All as per description of item No. 2 but except bricks complete all as specified and directed. |
| 4 | Taking down cement plaster on brick or concrete surfaces any description including raking out joints hacking for key scrubbing down with water complete all as specified and directed. |
| 5 | M&L for Rendering 15mm thick in cement mortar 1:4 on fair faces of brick work or concrete surfaces finishing the surfaces even & smooth without using extra cement including scaffolding upto 7 meter height and curing the surface, complete all as specified and directed. |
| 6 | M&L for Rendering 5mm thick in cement mortar 1:3 on concrete surfaces ceiling/ top and sides of chajjas/ facia of roof projection including necessary formwork including finishing the surface even and smooth without using extra cement complete all as specified and directed. |
| 7 | M&L liquid water proofing treatment to RCC roof slab incld dismantling of existing treatment of any description in following procedure : (a) Laying 10mm thick rendering in Cement mortar 1:4 mixed with WPC 3% by weight of cement on fair faces of concrete roof surfaces , finished even and fair to receive treatment on roof Complete (b) Applying first coat fiber reinforced elastomeric liquid water proofing membrane formulated with PU hybrid polymers and reinforcing acrylic fibers with sun reflective index (SRI) of 100-110, having minimum elongation of 350%, tensile strength 2.9 Mpa and shall have reack bridging ability upto 2.5mm and shall resist 10 bars of hydrostatic pressure reduce surface temperature upto 10 degree celsius with 3.3% dilution as priming coat (c) laying of fiber mesh 0.3mm thickness weave in leno pattern having weight 4.5 gm/ Sqm and pasting it properly with overlap of 50mm and allow it to dry (d) Applying second coat undiluted @ 0.45 ltr/ sqm as directed by Engr-in-Charge (e) Applying third and final coat undiluted @ 0.45 ltr/ sqm as directed by Engr-in-Charge. (The rate includes for filling cracks in existing roof with cement putty using suitable bonding agent (shalcrate 42) before laying cement plaster) |
| 8 | M&L for PCC 1:2:4 type B-0 (using 12.5mm graded crushed stone aggregate) as in padding over roof slab for providing proper slabs, and finishing the surfaces even & smooth without using extra cement including demolition of cement concrete of any description, complete all as specified and directed. |
| 9 | M&L for Rendering 10mm thick on cement mortar 1:3 in facia or edging of chajjas, (width/ height not exceeding 45 cm) to protect movement of water inside and act in place of damaged drip course including preparation of new surface and applying two coats of cement base paint complete all as specified and directed. |
| 10 | M&L for Rendering 10mm thick in cement mortar 1:6 on fair faces of brick work or concrete surfaces finishing the surfaces even and smooth without using extra cement including scaffolding at any height and curing the surface, complete all as specified and directed. |
| 11 | M&L for cutting opeaning through brick walls for doors,window and other opeanings or enlarging existing openings,converting windows into door etc or cutting out for defective brickwork including making plastering the damaged surface & making good and cleaning and stacking bricks,removing surplus servicable bricks etc to store and removing the rubbish not exceeding 50m complete all as specified and directed. |
| 12 | M & L for reinforced cement concrete M-20 (Nominal Mix)Type B1 1:2:4 using 20 mm aggregate in beams, cantilevers, shelves, bressummers, lintels over 1.5m span complete all as specified and directed. |
| 13 | M&L for acid resistant tiles 15mm thick vitreous ceramic unglazed set jointed and pointed in chemical resistance mortar resin type as in floors over 15mm thick screed bed in cement mortar 1:4 including dismantling of floor tiling incl cement mortar bedding (but not backing) removing serviceable tiles to a store and rubbish off permises,complete all as specified and directed. |
| 14 | Material & Labour for applying Two coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces of walls all as specified and directed |
| 15 | M&L for preparation of new plastered surfaces of wall including cornices plasters and applying two coats of oil bound distemper over a coat of primer on wall over 1 mm thick wall care putty complete all as specified & directed by Engr-in-Charge. |
| 16 | Dismantling timber scantling inc old wooden trusses, purlins, rafters etc 40sqcm and over in section in any position complete all as specified and directed. |
| 17 | Demolition of stone slabs, paver blocks and tiles of any description or thickness in floors/apron laid dry complete all as specified and directed. |
| 18 | M&L for 75mm thick PCC (1:3:6) type C2 using 20mm graded crushed stone aggregate as in sub base complete all as specified and directed. |
| 19 | M&L for Non skid ceramic joint free colour tiles 7 to 8 mm thick (sq/ rect) area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm, in floor etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the colour of tiles laid over and including 15mm thick screed bed in cement mortar 1:4 including dismantling of floor tiling incl cement mortar bedding (but not backing)removing serviceable tiles to a store and rubbish off premises complete all as specified and directed. |
| 20 | Taking down chowkat or frame with shutter (without taking off shutter from the frame) not exceeding 1.50 Sqm each including taking out hold fast embedded in PCC, complete all as specified and directed. |
| 21 | Taking down chowkat or frame with shutter (without taking off shutter from the frame) exceeding 1.5 Sqm and n.exc 4 Sqm each including taking out hold fast embedded in PCC, complete all as specified and directed. |
| 22 | S&F powder coated Anodised aluminium frame for doors, windows, ventilators with one or more rebates including joining cleat for fixing etc. with Powder Coating (minimum thickness of powder coating 50 micron & min weight not less than 0.55 kg/Rm), complete all as specified and directed. |
| 23 | S & F for Powder coated Anodised aluminium door shutters, aluminium section weighing not less than 0.55 kg/ m including necessary joining cleats, glazing clips, rubber neoprene packing, handles 2 Nos in each door, hinges, anodised aluminum snap beading screws etc. including powder coating of any colour (Thickness or powder coating not less than 50 micron), complete all as specified and directed. |
| 24 | S & F for powder coated Anodised aluminium window and ventilator shutters, side hung type without or with sash bars, aluminium sections weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws, anodised aluminium fittings such as peg stays 150mm long (1 no.). hinges type 100mm long (2 no.) suitable handle (1 no.) include powder coating of any colour (Thickness or powder coating not less than 50 micron), complete all as specified and directed. |
| 25 | S &F for 5.5mm thick selected quality tinted sheet glass including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws etc. in aluminum partition / doors / windows / ventilators etc. complete all as specified and directed. |
| 26 | S&F 3 ways sliding anodized aluminium glazed window shutter with frame & with following specifications all as specified & directed:-(a) window frame 3 track of size 95mmx25mmx1.5mm thick(b) Stiles and rails of size 35mmx25mmx1.5mm(c) 35mmx35mmx1.5mm T section mullion(d) PVC gasket with 4mm thick tinted glass, incl aluminium handles with necessary locking arrangement for 02 Nos glazed shutter.(e) Stainless steel wire cloth, 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire stapples incl aluminium handles with necessary locking arrangement for 01 Nos gauzed shutter.Note:- Measurement to be taken as overall width and height of window. No shutter or frame to be measured separately. All necessary accessories including tinted glass and stainless steel wire cloth required for assembling and fixing window at proper place complete are deemed to be inclusive. |
| 27 | S&F in repair aluminium body door closer hydraulically regulated designation No 3 universal type of dia cast body, suitable for door shutter for taking weight up to 80kg complete all as specified and directed. |
| 28 | S&F floor door stopper of overall length of cover plate 140mm or 150mm aluminium alloy body and tongue, anodised, with hard drawn steel spring fixed in floor complete all as specified and directed. |
| 29 | S&F for aluminium mortice lock, vertical type 75mm size of 4 lever, complete all as specified and directed. |
| 30 | M&L for Mild steel TMT bars 10mm dia and over cut to length bent to shape required including cranking, bending, binding with mild steel wire (annealed) not less than 0.9mm dia complete all as specified and directed. |
| 31 | S&F plain galvanised mild steel sheeting 0.63 mm thick as in valley gutter,ridges,hips,and straight flashing (length & girth ) with grade of zinc coating 275 complete all as specified and directed. |
| 32 | M&L galvanised, corrugated mild steel sheeting 0.63mm thick with two corrugation side lap bent to curve of any radius fixed with coach screws and washers in roofs/wall cladding/ or any similar works with grade of zinc coating 275 complete all as specified and directed by Engineer-in-Charge. |
| 33 | Preparation of old steel surface of any description and applying two coats of synthetic enamel paint over a coat of primer on corrugated galvalume sheet bent to curve of any radius complete all as specified and directed by Engineer-in-Charge. |
| 34 | M&L for 50mm thick PCC, type C-2, 1:3:6, (using 20mm graded crushed stone aggregate) as in plinth protection finishing the surface even and smooth without using extra cement complete all as specified and directed. |
| 35 | Repair the leakage/seepage/hole/crack of roof sheet of any description and in any position and upto 7.5 m height using Super flash Strip 100/150 mm wide complete all as specified and directed. |
| 36 | M&L for Preparing the new steel surfaces of any description over 10cm width or girth priming with red oxide zinc chrome and applying two coats of synthetic enamel paint complete all as specified and directed. |
| 37 | M&L for mild steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to IS-1161-1979 grade St-240, complete all as specified and directed. |
| 38 | M&L steel work in plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) Forming holes with riveted, bolted, or welded attachments, complete all as specified and directed. |
| 39 | Dismantling of Asbestos cement (corrugated, semi corrugated, etc.) sheets in roof coverings, complete all as specified and directed. |
| 40 | Taking down rolling shutter of area upto 50 sqm area including hard cover, shafts and tension spring, anchoring rod complete all as specified and directed. |
| 41 | S & F for Mild steel, thickness of sheet 1.25mm plain, black sheet in wall cladding, steel gates and similar work, cut to size, holes punched; including round headed screws, clout nails or rivets and fixed to wood or steel framing with plain 40 mm lap joints with riveted or welded seams, including bending or turning up, mitred angles, etc. as required and complete all as specified and directed. |
| 42 | S & F for Joist, channel, angle, or tee sections, fixed independently, without connecting plates, etc. (cut to ordinary lengths i.e. within 20mm of the length indicated) complete all as specified & directed. |
| 43 | S & F for Steel roller of any dia for rolling/sliding shutters all as specified & directed. |
| 44 | M&L for machine cut Kota stone, stone slab flooring 18-20mm thick over screed bed 20mm thick in cement mortar 1:4 set, jointed and pointed with grey cement slurry mixed with pigment to match the shade of the slab including, rubbing and granite polishing, complete all as specified and directed. |
| 45 | M&L for kota stone slab 18 to 20mm thick in riser, steps, skirting, dado and pillar laid over 10mm thick cement screed in cement mortar 1:4 and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing, rounding to edges of stone slabs one edge, such as in steps and landing complete all as specified and directed. |
| 46 | M&L Prepainted Galvalume aluminium zinc coated @150 gm/sqm GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength 550 Mpa as in roof covering/cladding to walls, fixed with self taping screws and overlap with sufficient laps, complete all as specified and directed. |
| 47 | M&L pre painted Galvalume aluminium zinc coated @150 gm/sqm GI based plain steel sheeting 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to walls, fixed with self taping screws, complete all as specified and directed. |
| 48 | Providing & fixing 12mm thick semi perforated micro tegular edged GRG false ceiling at all heights with GRG (Glass Fibre Reinforced Gypsum) false ceiling tiles of Size 595 x 595 mm of approved texture, design and patterns having moisture content less than 2%, humidity resistance of 99%, NRC0.50 to 0.75 as per IS 8225:1987, Noncombustible as per BS 476 (part 4 )-1970 and light reflectance of 85% (minimum) to be laid in true horizontal level suspended on inter locking metal T-Grid of hot dipped galvanized iron section of 0.33mm thick (galvanized @ 120 grams per sqm including both sides) comprising of main T runners of size 15 x 32 mm of length 3000mm,cross-T of size 15x 32mm of length 1200mm and secondary intermediate cross-T of size 15 x 32 mm of length 600mm to form grid module of size 600x 600mm, suspended from ceiling using galvanized mild steel items (galvanizing @ 80 grams per sqm) i.e 50mm long, 8mm outer diameter M-6 dash fasteners, 6mm dia fully threaded hanger rod upto 1000mm length and L shape level adjuster of size 85x25x2mm. Galvanised iron perimeter wall angle of size 24x 24x0.40mm of length 3000 mm to be fixed on periphery wall I partition with the help of plastic rawl plugs at 450 tmm center to center and 40mm long dry wall wood screws. The work shall be carried out as per specifications, drawing and as per directions of the Engineer-in Charge including Dismantling of Wall and ceiling boards (fibre, pulp, insulation, etc.) or insulation boards/slabs/blankets, any thickness at any height, including cover fillets complete all as specified and as directed. |
| 49 | M&L for Framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing complete, Fe-410-W Gde E-250 of quality 'A', complete all as specified and directed. |
| 50 | Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc. complete all as specified and directed. |
| 51 | Taking down existing unserviceable submain wiring of any size and making good the disturbed surface complete all as specified and directed. |
| 52 | S&F VTPN DBs Double Door 4 way suitable for MCCB 100 amp incomer, IP 43 protection 415 V AC, 50 Hz AC appropriate size of bus bar and neutral link complete all as specified and directed. |
| 53 | S&F MCCB TPN 100 Amp 415V 16KA 3 pole in the DB complete with connection testing and commissioning complete all as specified and directed. Please Enable Macros to View BoQ information |
| 54 | S&F MCCB TPN 100 Amp 415V 16KA 3 pole in the DB complete with connection testing and commissioning complete all as specified and directed. Please Enable Macros to View BoQ information |