| 1 | Supplying & installation of 7 Mtr long GI Octagonal pole with 1 mtr arm & Foundation Bolt with 220 sqmm base plate etc along with other accessories as required. |
| 2 | Supplying & fixing of 100/120W Streetlight in aluminium die cast powder coated , pole mounted with driver efficiency of >= 85%, IP 66, IK10 rating including necessary connecton as required (With 100000 burning hours , system lumens ( +-10%) 13000 and 5 years replacement warranty ). |
| 3 | Earthing with 40 mm dia G.I. Earth pipe (medium gauge) 4.5 m. long complete with masonry enclosure on top CI cover plate size 12\\"x 12\\" having locking arrangement including CC work, holes on earth pipe etc. as required:- |
| 4 | Extra for using salt (5 kg) and charcoal (46kg) for pipe earth electrode as required:- |
| 5 | Proving and fixing / drawing of 4.06 mm dia (8 SWG) G.I. wire on surface or in existing G.I/ PVC/ Polythene pipe for loop earthing as required. |
| 6 | Providing and laying 15mm dia(medium gauge) G.I. pipe for drawing of 4.06mm (8SWG) dia G.I./ Copper wire for earth connection from earth electrodes etc as required. |
| 7 | Supplying and laying of the following sizes XLPE insulated PVC sheathed aluminium conductor armoured cable with necessary connection etc as required |
| 8 | 3 core 4 Sq mm:- |
| 9 | 4 core 10 Sq mm:- |
| 10 | 4 core 16 Sq mm:- |
| 11 | 4 core 50 Sq mm:- |
| 12 | 4 core 120 Sq mm:- |
| 13 | 4 core 300 Sq mm:- |
| 14 | Supplying and laying of following sizes XLPE insulated PVC sheathed Aluminium conductor Un-armoured cable including necessary connection etc as required. |
| 15 | 3 core 4 Sq mm:- |
| 16 | Supplying and laying of following sizes XLPE insulated PVC sheathed copper conductor Un-armoured cable including necessary connection etc as required. |
| 17 | 3 core 1.5 Sq mm:- |
| 18 | Providing earthing system with maintenance free earthing electrode of 50 mm dia & 3 mtr long of dual electrode technology filled with highly conductive compound and back fill compound of 2 nos. 25 kg bag, terminal size 32mmx 6mm including accessories with masonry enclosure of CI cover plate size 12\\"x 12\\" having locking arrangement including CC works etc as required:- |
| 19 | Supply and fixing of 25mm x 5mm GI strip on wall/ floor of the building for horizontal/ vertical run including necessary spacers and porcelain insulators at regular intervals. |
| 20 | Earth work in excavation by mechnical means ( Hydraulic excavator)/ manual means in foundation trenches or drains ( not exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift upto 1.5m, including getting out the excavated soil and disposal f surplus excavated soil as directed, within a lead of 50m. All kinds f soil. |
| 21 | Supplying & filling in plinth, under floor, foundations etc. with sand (fine) from local quarry with all lifts including spreading in horizontal layers, watering, grading to required slope, ramming, consolidating and compacting each layer by using plate compactor or by any suitable method complete. |
| 22 | Reinforcement for R.C.C work including straightening, cutting,bending, placing inposition and binding all complete upto plinth level. |
| 23 | Thermo-Mechnically Treated bars of grade Fe-500 D or more:- |
| 24 | Providing and laying in position specified grade of reinforced cement concrete excluding the cost of centering, shuttering, finishing and reinforcement- 1:2:4 ( 1 Cement: 2 fine sand : 4 graded well burnt brick aggregate 20 mm nominal size):- |
| 25 | Centering shuttering including struttings, propping etc. and removal of form work for: Foundations, footings, bases for columns etc. for mass concrete with timber plank:- |
| 26 | 6 mm cement plaster in single layer including cost of materials required and finishing even and smooth and curing complete. In cement mortar 1 : 4 ( 1 cement : 4 fine sand ):- |
| 27 | Neat cement punning:- |
| 28 | Excavation of earth for cable trench of 800mm depth & 300mm width in all kinds of soil including back filling of cable trench with the excavated soil with 20cm layer of sand, 3.5 nos bricks per metre for protection including ramming, consolidating to the original shape as per dirrection of Site Engineer :- |
| 29 | Drawing of armoured/un-armoured cable with proper saddling etc as required:- |
| 30 | Supplying and fixing of thermoplastic cable junction box with connectors suitable for following sizes cable:- |
| 31 | 1.5 sqmm - 4 sqmm Cable:- |
| 32 | 10 sqmm - 16 sqmm Cable:- |
| 33 | Supplying & installation of TP/FP MCCB of following ratings in the existing MCCB enclosure/ panel board including connection etc as required (Ics=100% of Icu with adjustable settings):- |
| 34 | 16 to 100 amps FP MCCB, Breaking capacity 16/18KA (Thermal Magnetic):- |
| 35 | 160 amps FP MCCB, Breaking capacity 25KA (Thermal Magnetic) :- |
| 36 | 320 amps FP MCCB, Breaking capacity 36KA (Thermal Magnetic) :- |
| 37 | Supplying, installation, testing & commissioning of powder coated prewired digital meter module complete with ammeter, voltmeter, phase indicator lamp, control fuses, CTs, in the existing panel board including connection etc. as required:- |
| 38 | Supplying, installation, testing and commissioning of following ratings inverter with Square/ sine wave technology, noiseless operation, inbuilt advance PCB programming, microprocessorwith all accessories including necessary connections etc. as required:- |
| 39 | 1500VA, 24V DC, 1 Ph input/1 Ph output inverter(Sine wave technology):- |
| 40 | Supplying, installation, testing and commissioning of following ratings Valve regulated lead acid(VRLA) battery with all accessories including necessary connections etc. as required:- |
| 41 | 12 V/ 200AH tall tubular/ flat plate Battery:- |
| 42 | Supplying and fixing of aluminium terminal ends (LUGS) - long barrel of following sizes : - |
| 43 | 10 sqmm :- |
| 44 | 16 sqmm :- |
| 45 | 50 sqmm :- |
| 46 | 120 sqmm :- |
| 47 | 300 sqmm :- |
| 48 | Supplying, installation, testing, commissining of totally enclosed weather proof double door cubical type feeder distribution pillar box with base (2000 mm x 500mm) made up of MS angle of size (40 mm x 40 mmx 5mm) grouted on ground with CC work by four nos legs of size 500 mm made up of MS angle and body of size ( 2000 mm x 1600 mm) fabricated out of 2mm thick (14 G) 1200 mm width MS sheet for enclosing 10 nos 63/160 amps MCCB and 2 nos Copper busbar chamber of sixe 600mm x 400 mm x 80 mmm & 300 mm x 250 mm x 30 mm with insulator, hinged detachable but lockable front door, including painting and necessary connection as required as per direction of the site Engineer. |
| 49 | Wiring for Circuit/Sub-main with the following sizes of PVC insulated Copper conductor cable (FR) in existing PVC casing capping/ conduit in recess/surface including connection etc. as required:- |
| 50 | 4 X 35 sq mm |
| 51 | Supplying & fixing of 20W Post Top in aluminium die cast pole mounted with driver efficiency of >= 85%, IP 66, IK 05 including necessary connecton as required (With 50000 burning hours , system lumens ( +-10%) 1900 and 5 years replacement warranty ). |
| 52 | Supplying and fixing of the following electrical accessories including necessary connection etc. as required. |
| 53 | 32 amps DP kit kat switch:- |
| 54 | Supplying and installation of Bus bar chamber of the following ratings and sizes made of steel sheet enclosure with all accessories including necessary connection etc. as required:- |
| 55 | 32 amps 415 volts four strip Copper busbar chamber 4 ways of size (300mmx240mmx80mm):- |
| 56 | Supplying and installation of Switch disconnector fuse unit (main switch) of the following ratings with all accessories including necessary connection etc. as required:- |
| 57 | 32 amps 415 volts TPN main switch (rewireable):- |
| 58 | Supplying and fixing of MS frame made of (25mm x 25mm x 5mm) MS angle with necessary support by (40mm x 6mm) MS flat and 12 mm thick marine plywood on top, grouted on wall with 4 nos legs (25mmx25mmx5mm MS angle 20 cm long) finished with red oxide and 2 coat synthetic enamel paint including necessary cc work, mending the damages & painting etc as required:- |
| 59 | Wiring for circuit/Sub-main wiring with the following sizes of PVC insulated copper conductor cable (FR) in PVC conduit etc as reqd.:- |
| 60 | 2 X 1.5 sq mm |
| 61 | 2 X 2.5 sq mm |
| 62 | 2 X 4 sq mm |
| 63 | Supplying and fixing of following surface/recess mounted LED luminaries in powder coated die cast housing complete with high efficiency polycarbonate diffuser and necessary connection etc. as required (with 50000 burning hours and minimum lumen output of 100 lm/watt):- |
| 64 | Surface mounted integrated 20 watt LED batten with polycarbonate diffuser:- |
| 65 | Surface mounted round/Square shaped 12 watt LED downlight with integral driver and high quality polycarbonate diffuser:- |
| 66 | Supplying & fixing of 1200 mm sweep white color AC ceiling fan capacitor type double ball bearing complete with 300 mm down rod,canopies,shackles, 3nos blades, including wiring the down rod with 2x1.5 sqmm PVC insulated Copper conductor cable(FR) (ISI marked, BEE 1 star/minimum service value 4.0 m3/min/W) : - |
| 67 | Supplying & fixing of G.I. pipe (medium gauge) bracket fabricated at suitable angle for fixing of outdoor light on wall/ RCC base with necessary MS clamp, nut, bolt etc as required:- |
| 68 | 40 mm dia:- |
| 69 | 50 mm dia:- |
| 70 | Supplying & installation of 10 KA breaking capacity, B/C curve MCB of following ratings in the existing MCB DB including connection as required:- |
| 71 | 6 to 32 amp SP MCB:- |
| 72 | 6 to 32 amps DP MCB:- |
| 73 | 6 to 32 amps FP MCB:- |
| 74 | Supplying and installation of powder coated steel sheet enclosure (MCB DB) suitable for 240/415 volts MCB/Isolator/RCCB (SP/SPN/DP/ TP/TPN/FP) complete with necessary bus bar, neutral link, din rail, earth bar etc i/c connection as required:- |
| 75 | 2 way SPN MCB DB (single door):- |
| 76 | Supplying and fixing of the following PVC conduit (medium gauge) with all accessories on slab/recessed on wall etc as required:- |
| 77 | 19/20 mm dia:- |
| 78 | Providing , fixing and laying rigid UPVC pipes conforming to IS:4985 jointing with couplers of same class conforming to IS:10124 (Pt-II) with solvent cement conforming to IS:14182 including testing of joints complete ( but excluding the cost of specials like bend, tees etc which will be paid seperately) as per CPWD specification & direction of the Engineer-in -charge. A. Class-3 (working pressure 6.0kg/cm2) |
| 79 | 110 mm OD:- |
| 80 | Supplying & installation of Digital timer Switch including necessary connection etc as required:- |
| 81 | Supplying & installation of following power contactors including necessary connection etc as required:- |
| 82 | 3 pole 12 amps (AC3) power contactors with 1NO+1NC Aux. Contact. Please Enable Macros to View BoQ information |