| 1 | Providing, laying, testing & commissioning of 'C' class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shadecomplete as required :25 mm dia (DSR 2025 ref.27.7.1) |
| 2 | (i) 80 mm dia (DSR 2025 ref. 27.7.6) |
| 3 | (ii) 100 mm dia (DSR 2025 ref. 27.7.7) |
| 4 | Supplying, fixing, testing and commissioning of Sulice valve of PN1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS -780 of following sizes as required :(i) 100 mm dia (DSR 2025 ref. 27.12.5) |
| 5 | (ii) 150 mm dia (DSR 2025 ref. 27.12.6) |
| 6 | Supplying, fixing, testing and commissioning of Butterfly valve of PN1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS-13095 of following sizes as required :(i) 80 mm dia (DSR 2025 ref. 27.11.4) |
| 7 | (ii) 100 mm dia (DSR 2025 ref. 27.11.5) |
| 8 | Providing, installation, testing and commissioning of non-return valveof following sizes confirming to IS: complete with rubber gasket, GI bolts, nuts, washers etc.as required :(i) 100mm dia (DSR 2025 ref. 27.14.5) |
| 9 | (ii) 150mm dia (DSR 2025 ref. 27.14.6) |
| 10 | Providing and fixing dial type pressure gauge with isolation cock and SS pipe at hydrant station. Dial diameter 100 mm calibration 0.15kg/sq.cm. (DSR 2022 ref. 16.8) HVAC |
| 11 | Providing & fixing of pressure switch in M.S. pipe line including connection etc. as required. (DSR 2022 SI no-18.22) |
| 12 | Supplying and fixing single headed internal hydrant valve with instantaneous Gunmetal/Stainless Steel coupling of 63 mm dia with cast iron wheel ISI marked conforming to IS 5290 (Type -A) with blank Gunmetal/Stainless Steel cap and chain as required :Single headed stainless steel (DSR 2025 ref. 27.09.2) |
| 13 | Supplying and fixing 63 mm dia, 15 m long RRL hose pipe with 63 mm dia male and female couplings duly bound with GI wire, rivets etc. conforming to IS 636 (type-A) as required :Stainless steel (DSR 2025-27-16) |
| 14 | Supplying and fixing first-aid Hose Reel with MS construction spray painted in post office red, conforming to IS 884 complete with the following as required. 20 mm nominal internal dia water hose thermoplastic (Textile reinforced) type -2 as per IS: 12585 20 mm nominal internal dia gun metal globe valve & nozzle. Drum and brackets for fixing the equipments on wall. Connections from riser with 25 mm dia stop gun metal valve & M.S. Pipe and socket.30 mtr (DSR 2025-27-17-1) |
| 15 | Supplying and fixing of fire brigade connection of cast iron body with gun metal male instantaneous inlet couplings complete with cap and chain as reqd.for suitable dia MS pipe connection conforming to IS 904 as required:(DSR2025-27-19-3) (a) 3-Way(Make-Agni) |
| 16 | Providing and fixing of self illuminated /auto glow \\"EXIT\\" signs printed on photoluminescent 1.0 mm Rigid sheet containing self illuminated base chemical, of appropriate size not less than 300 x 150 mm, suspended from ceilling or fixed to the walls with accessories as required and as directed at site. Complete in all respect to the entire satisfaction of the Engineer-in-Charge.(AGNI)(AR) |
| 17 | Providing and fixing dust & vermin proof cubicle type motor control centre fabricated from powder coated 16 SWG MS sheet for ELECTRICAL PANEL FOR TERRACE PUMP suitable for Terrace fire pump and automatic/ Manual operation complete in all respect as required. Electric panel board comprising of DOL starter auxiliary switch, main in commer, three phase preventer, voltmeter indication lamps, pressure guage M.C.B.40amp. Rating including all connections with copper cable etc. (To star the terrace pumps). Complete in all respect to the entire satisfaction of the Engineer-in-Charge. (NS) (AR) |
| 18 | Supplying & laying of 2x1.5 sqmm fire alarm armoured cable, 600/1000V rated with annealed copper conductor having XLPE insulation, steel wire armouring & FRLSouter sheath complete asrequired. (DSR 2025 ref. 28.5.2) |
| 19 | Reconditioning, overhauling, servicing, cleaning of all existing installed different sizes Hose Reel Drum including repairs/replacement of internal defective parts, greasing, oiling, repair of pipe connection with GI Fittings so as to make them in proper functional condition etc complete as required as per site location to make it funcitional. (AR) |
| 20 | Reconditioning of the Electric driven Terrace pump 900 LPM Set i/c overhauling repairing, checking, servicing, greasing the same after effecting necessary repairs / replacement of internal defective parts etc. as required i/c alignment of the pump & motor re-testing & commissioning etc., complete as required. (Note:The Job i/c making the same in automatic operation mode & repairing, replacing all the defective part of the Terrace pump set including Mechanical seal as required. (AR) |
| 21 | Reconditioning, Servicing, Checking including replacement of defective internal part/washers/ gaskets etc. as required of single headed landing valve etc. complete as required. The job include cost of pressure testing of the hydrant valve after repair repainting of the same as required to make it funcitional etc.(AR) |
| 22 | Providing and Fixing of Stainless steel nozzle 20 mm dia with 5 mm outlet for 25 mm dia thermoplastic pipe complete as required.(AR) |
| 23 | Providing and Fixing of Manual call boxes of ABS Type in surface/recess with stainless steel chain & hammer assembly complete with glass and push button etc ( Make-AGNI) DSR-28.1.3 |
| 24 | Providing and Fixing of Fire alarm sounders (electronic) with facility to make announcement, mounted in ABS. Box with hinged cover plate & suitable for operation with amplifier i/c line matching ttransformer etc( Make-AGNI) DSR-28.1.6 |
| 25 | Providing and Fixing of Main panel 10 zone suitable for following zones complete with visual indications for short curciut fault,open curciut fault,fire condition and all other standard facilities as per IS-2189 with complete all interconnection and connection as required.etc( Make-Panel-AGNI/Amplifire-Ahuja) DSR2025 -28.1.9.3 |
| 26 | SITC of smoke detector with built in LEd and mounting base complete with all connection etc as required.(AGNI/Apollo) DSR 2025-28.1.2 |
| 27 | Repainting of all MS fire pipes with synthetic enamel paint after cleaning of all dust and rust with 2 or more coats already provided in fire shaft,terrace,open area and terrace pump room 25 mm to 150 mm dia. DSR 2025/13.53.1(i) 25 mm dia |
| 28 | (ii) 32 mm |
| 29 | (iii) 40 mm |
| 30 | (iv) 50 mm |
| 31 | (v) 65 mm |
| 32 | (vi) 80 mm |
| 33 | (vii) 100 mm |
| 34 | (viii) 150 mm |
| 35 | S/D following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required.DSR 2025/1.17(i) 2x1.5 sqmm, 1.17.2 |
| 36 | (ii) 3x1.5 sqmm, 1.17.3 |
| 37 | (iii) 4x1.5 sqmm, 1.17.4 |
| 38 | (iv) 5x1.5 sqmm, 1.17.5 |
| 39 | (v) 6x1.5 sqmm, 1.17.6 |
| 40 | Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. a) 20 mm dia. DSR 2025/1.21.1 |
| 41 | Supplying and fixing air vessel made of 250 mm dia, 8 mm thick MS sheet, 1200 mm in height with air release valve on top and flanged connection to riser, drain arrangement with 25 mm dia gun metal wheel valve with required accessories, pressure gauge and paintingwith synthetic enamel paint of approvedshade as required.(DSR-27.20) |
| 42 | Supply and fixing of CO2 type Fire Extinguisher 4.5 Kg.Capacity (ISI Marked IS: 2878 & TAC approved). complete with intial charge and wall bracket,along with supply of all materials and labour for proper completion of work.SOR/2018-1132 (Electrical) |
| 43 | Supply and fixing of Powder Fire Extinguisher ABC type Capacity 06 Kg (ISI Marked conforming to IS: 15683 & TAC approved) complete with intial charge and wall bracket,along with supply of all materials and labour for proper completion of work.SOR/2018-1131(A) electrical Please Enable Macros to View BoQ information |