| 1 | Sunrise Aqua Coolers Storage Drinking Water Cooling Capacity 50L/Hour |
| 2 | Dining Chair |
| 3 | Add GST @ 18% |
| 4 | Add L.Cess @ 1% |
| 5 | Providing and laying APP (Atactic Polypropylene Polymer) modified prefabricated five layer, 3 mm thick water proofing membrane, black finished reinforced with glass fibre matt consisting of a coat of bitumen primer for bitumen membrane @ 0.40 litre/sqm by the same membrane manufactured of density at 25°C, 0.87 - 0.89 kg/litre and viscocity 70 - 160 cps. Over the primer coat the layer of membrane shall be laid using butane torch and sealing all joints etc., and preparing the surface complete. The vital physical and chemical parameters of the membrane shall be as under : Joint strength in longitudinal and transverse direction at 23°C as 350/300 N/5 cm. Tear strength in longitudinal and transverse direction as 60/80N. Softening point of membrane not less than 150°C. Cold flexibility shall be upto -2°C when tested in accordance with ASTM, D - 5147. The laying of membrane shall be got done through the authorised applicator of the manufacturer of membrane :14.90.1 3 mm thic |
| 6 | Covering of treated surface with PCC :- Providing 50 mm thick Cement Concrete M20(1:1.5:3) maintaining slope in alternate 2 mt x 2 mt panels with aaproved quality of stone chips of 20 mm |
| 7 | Dismantling plane cement or lime concrete work .do........E/I |
| 8 | Dismentling of old plaster and pointing in cement or lime and racking out joint to 15 mm depth watering and disposal of unserviceable materials with all lead ---do -- all complte job as per specification and direction of E/I |
| 9 | Providing 6mm thick cement plaster (1:4) in ceiling with clean coarse sand of F.M. 1.5 including screening, curing with all leads and lifts of water, scaffolding taxes and royalty all complete as per building specification and direction of E/I. |
| 10 | Providing 12mm cement plaster (1:6) on Inside walls with clean coarse sand of F.M 1.5 including cost of carriage, screening curing with all lead and lifts of water, scaffolding, taxes and royalty all complete as per building specifications and direction of the E/I. |
| 11 | Dismantling patent stone floor including .do........E/I |
| 12 | Taking down choukhat |
| 13 | providing one coats of Oil bound Distemper of approved shed and make over old surface……………………...E/I |
| 14 | Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade : New work (Two or more coats applied @ 1.43 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm). |
| 15 | Supplying, Fitting and fixing M.S grill made of 20 x 6mm M.S. flat as per approved design and drawing, properly fabricated with joints continuous fillet welded and finished smooth, hoisting carriage of grill to work site hoisting as per building specification and direction of E/I. |
| 16 | Providing and fixing 10 mm thick acid and/or alkali resistant tiles of approved make and colour using acid and/or alkali resisting mortar bedding, and joints filled with acid and/or alkali resisting cement as per IS : 4457, complete as per the direction of Engineer-in- Charge. In flooring on a bed of 10 mm thick mortar 1:4 (1 acid proof cement : 4 coarse sand) Acid and alkali resistant tile |
| 17 | Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades |
| 18 | Providing and fixing pressed steel door frames conforming to IS: 4351, manufactured from commercial mild steel sheet of 1.60 mm thickness, including hinges, jamb, lock jamb, bead and if required angle threshold of mild steel angle of section 50x25 mm, or base ties of 1.60 mm,pressed mild steel welded or rigidly fixed together by mechanical means, including M.S. pressed butt hinges 2.5 mm thick with mortar guards, lock strike-plate and shock absorbers as specified and applying a coat of approved steel primer after pre-treatment of the surface as directed by Engineer-in-charge: |
| 19 | Supplying ,fitting and fixing 30 mm thick solid core non decorative single leaf flush shutter .do....... |
| 20 | Supplying, fitting and fixing 20 guage G.C.I. Sheet gate fitted on M.S. Angle frame of size 60X60X6mm. Including cost of fabrication, providing necessary locking arrangement with haskal and domny duly fixed in P.C.C. (1:2:4) blocks of required size applying a priming red lead paint over steel work, taxes all complete as per drawing specification and direction of E/I. |
| 21 | Labour for scrapping old paint with paint remover and below lamp as required on wooden or steel surface including cost of all labour and materials and scaffolding all complete as per building specification and direction of E/I. |
| 22 | Providing two coats of synthetic enamel paint of approved shade and make over steel surface.......do..........do.....E/I |
| 23 | Providing & fixing on wall face unplasticised - Rigid P.V.C. rain water pipes conforming to IS: 13592 Type A including jointing with seal ring conforming to IS: 5382 leaving 10mm gap for thermal expansion . Single socket ed pipes. 110 mm dia |
| 24 | SHOE - 110MM |
| 25 | Bend (110 mm) |
| 26 | 1:1½:3 (1 cement : 1½ coarse sand (zone-III) : 3 graded stone aggregate 20 mmnominal size). |
| 27 | Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement, with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size). |
| 28 | Providing TMT steel reinforcement 8mm, 10mm, 12mm & 16mm dia bars as per approved design and drawing excluding carriage of M.S bar to work site, cutting, bending end binding with annealed wire with cost of wire removal of rust placing the rods in position all complete as per building specification and direction of E/I.8mm dia Bar - |
| 29 | 10mm dia Bar - |
| 30 | Supplying labour tools and tackles for clesning filled and choaked man hole septic tank inspection chamber sewerage tank tank etc………. |
| 31 | Clearing grass and removal of rubbish up to a distance of 50 metres outside the periphery of the area By Manual Means |
| 32 | Providing and laying 25 mm thick white Makrana Marble Stone Slab Flooring of approved quality complete as per the architechtural drawing.300x600 mm |
| 33 | Providiag designation 75B brick work in Cement Mortar (1:6) in superstructure with approved quality of clean coarse sand of F.M. 2 to 2.5 including providing 10mm thick mortar joints, cost of screening materials, raking out joints to 15mm depth, curing taxes and royalty all complete job as per building specificition and direction of E/l.B.C.D. S.O.R. Item No. 5.2.14 |
| 34 | Providing 12 mm thick cement plaster (1:6) with clean coarse sand of F.M. 1.5 including screening, curing with all leads and lifts of water, scaffolding, taxes and royalty all complete as per specification and direcition of E/l. |
| 35 | Providing and laying Polished Granite stone flooring in required design and patterns complete as per the architechtural drawing. |
| 36 | Plywood 4 mm |
| 37 | Providing & Fixing decorative high pressure laminated sheet of plain / wood grain in gloss / matt/ suede finish with high density protective surface layer and reverse side of adhesive bonding quality conforming to IS : 2046 Type S, including cost of adhesive of approved quality |
| 38 | Providing corrugated G.S. sheet roofing including vertical / curved surface fixed with polymer coated J or L hooks, bolts and nuts 8 mm diameter with bitumen and G.I. limpet washers or with G.I. limpet washers filled with white lead, including a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete (up to any pitch in horizontal/ vertical or curved surfaces), excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required 0.63 mm thick with zinc coating not less than 275 gm/m² |
| 39 | Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. Steel work welded in built up sections/ framed work, including cutting,hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. |
| 40 | Providing and laying doublecharge vitrified floor tiles in different sizes(thickness to be specified by the manufacture) with water absorption less than 0.08% and conforming to IS: 15622/ISO 13006 of approved make,inall colors and shades,laid on 20mm thick cement mortar 1:4(1Cement:4coars sand) jointing with grey cement slurry @ 3.3kg/sqm including grouting the joints with white cement and matching pigments etc, cost of curing, taxes and royalty all complete as per building specification and direciton of E/l. |
| 41 | Designing, fabricating, testing, installing and fixing in position Curtain Wall with AluminiumComposite Panel Cladding, with open grooves for linear as well as curvilinear portions of the building , for all heights and all levels etc. including: (a) Structural analysis & design and preparation of shop drawings for pressure equalisation or rain screen principle as required, proper drainage of water to make it watertight including checking ofall the structural and functional design. |
| 42 | 220/230 Ah tubular Lead acid battery with 36 month replacement guaranty |
| 43 | 1100 to 1200 va Sine wave inverter input AC range 100 V to 300 V AC wide 90 V to 300 V AC standard 180 V to 260 V AC DC range 10.5 to 14.2 efficiancy 80 % prolectionoverload short circuit |
| 44 | Earth work in excavation in foundation trenches in ordinary soil ( vide classification of soil item A) and disposal of excavated earth as obtained to a distance upto 50M including all lifts leveling ramming the foundation treanches, removing roots of trees, and shrubs all complete as per approved design, building specification and direction of E/I. |
| 45 | Providing coarse clean sand in filling in in foundation trenches or in plinth including ramming and watering in layers not exceeding 150mm thick with all leads and lifts including cost of all materials labour, royalty and taxes all complete as per building specification and direction of E/I. |
| 46 | Providing designation 75B one brick flat soling joints filled with local sand including cost of watering taxes royalty all complete as per building specification and direction of E/I. |
| 47 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:2:4 (1 cement : 2 coarse sand (zone-III) : 4 graded stone aggregate 20 mm nominal size) |
| 48 | Providing designation 75B brick work in C.M (1:6 ) in foundation and plinth with approved quality of clean coarse sand of F.M. 2 to 2.5 including providing 10mm thick mortar, joints cost of screening materials raking out joints to 15mm depth, curring, taxes and royalty all complete as per builiding specification and direction of E/I. |
| 49 | Providing designation 125 mm thick reinforced designation 75A brick work in CM (1:4) in superstructure with approved quality of clean coarse sand of F.M. 2 to 25 including the cost of screening, carriage of materials, scaffolding , raking out joints to 15mm depth, curing, taxes and royalty (but excluding the cost of reinforcement) all complete as per building specification and direction of E/I. |
| 50 | Providing 12mm cement plaster (1:3) with clean coarse sand of F.M. 1.5 including screening, curing with all leads and lifts of water, scaffolding taxes and royalty all complete as per building specification and direction of E/I. |
| 51 | Providing 1.5mm cement punning including curing, carriage of water with all leads and lift as per building specification and direction of E/I. |
| 52 | Earth work in excavation in foundation trenches in hard soil (vide classification of soil item - A+B) and disposal of excavated earth as obtained to a distance up to 50M including all lifts with leveling, ramming the foundation trenches, removing roots of trees, shrubs all complete as perbuilding specification and direction of E/I. |
| 53 | Granular Sub-base with Close Graded Material (Table:- 400-1) By Mix in Place Method (Construction of granular sub-base by providing close graded material, spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with rotavator at OMC, and compacting with vibratory roller to achieve the desired density, complete as per clause 401) With Grading-III Material |
| 54 | Providing and laying factory made chamfered edge Cement Concrete paver blocks in footpath, parks, lawns, drive ways or light traffic parking etc, of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over 50mm thick compacted bed of sand, compacting and proper embedding/laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand. complete all as per direction of Engineer-in-Charge (ii). 80 mm thick Cement concrete paver block |
| 55 | Point Re wiring in Existing PVC conduit, with Piano type switch - Re Wiring for light point/exhaust fan point/call bell point with 1.5 sq.mm. FR PVC insulated copper conductor single core cable in surface/recessed PVC conduit, with piano type switch, phenolic laminated sheet, suitable size PVC/G.I. box etc. as required Group A |
| 56 | Wiring for Circuit / submain wiring along with the following size PVC / insulated copper conductor single core cable in surface/recessed PVC conductor single core cable for loop earthing as required.2x1.5 sq mm+1x1.5 sq mm earth wire |
| 57 | 2x2.5 sq mm+1x2.5 sq mm earth wire |
| 58 | 2x4 sq mm+1x4 sq mm earth wire |
| 59 | Supplying and fixing following modular type switch / socket on the existing modular plate and switch box including connections as required.15/16 amps , two way switch |
| 60 | 5/6 amps , 3 pin socket outlet |
| 61 | Supplying and fixing stepped type electronic fan regulatar on the existing modular plate and switch box including connections as required. |
| 62 | Supplying and fixing suitable size G.I boxwith modular plat and cover in front on surface or in recess with including provideng and fixing 3 pin 5/6 amps modular socket out let and 5/6 amps modular type switch in connection painting etc as required. |
| 63 | Supplying and fixing suitable size G.I box with modulaer plate cover in front on surface or in recess in front including provideng and fixing 6 pin 15/16 amps socket out let and 15/16 amps modulaer switch in connection painting etc as required. |
| 64 | Supplying and fixing 3 pin 5ams Ceilling rose on the existing junction box/ wooen including connection etc as required. |
| 65 | Supplying and fixing batten /angle holder including connection etc as required. |
| 66 | Supplying & fixing following way single pole neutral sheet MCB distriution board 240 volts on surface / recess complete with tinned copper busbar neutral busbar earth bar din bar detachable gland plate interconnection phosphatized powder painted includin2 Way Single door |
| 67 | Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FR PVC insulated, copper conductor, single core cable etc. as required.9.4.1 Supplying and fixing of ceiling fan -1200 mm 48\\" |
| 68 | Recess Mounting LED Round Down light |
| 69 | 16\\" (400mm) wall mountain |
| 70 | 20/22 Watt LED Tube Light |
| 71 | Exaust Fan (12\\" or 300 mm) |
| 72 | Supplying, fining and fixing 40mm high viterous white glazed earthen ware E.W.C with P-trap of Parry, Hindustan or any other I.S.S. make including supplying and fixing 15 ltr. C.I. mosquito proof low down flushing cistern of approved make with complete fittings with C.I. handle or R.S. brackets with telescopic flush pipe with brass coupling and plumber joints spindle stop cock of approved quiality weight not less than 450 grams, 15 mm P.V.C alkathene pipe 45cm long with brass coupling at both ends and white/black plastic solid state seal and lead of Commander/Cuckoo or other I.S.S. make with hinges or screws etc. painting pipe and cistern wtc. with two coats of approved paint over a coat of red oxide primeing, all complete as per specification and direction of E/I. |
| 73 | Supplying, fining and fixing viterous white glazed earthen ware I.W.C of Parry Hindustan or any other I.S.S approved make with 100mm H.C.I \\"p\\" trap 15 liters C.I. or C. pull and let go flushing cistern of names or other I.S.S equivalent make, complete with all fittings. C.I or C.C brackets 32mm alkathene/P.V.C telescopic flush, pipe about 2M long with one brass coupling and clamps G.I chain and pull including supplying and fixing a pair of viterous white glazed earthenware where footrest to be fixed in floor 15 mm C.I body brass spindle stope cock of weight not less than 50 grins. 15 mm P.V.C connection pipe 450mm long and the exposed pipe and cistern with two coats of approved paint over a coat of red oxide primer etc. all complete as per specification and direction of E/I. D.W.S.D. Item No. 3.2.1(A)(c) 580mm long with 10 litre low level P.V.C. cistern |
| 74 | Suppling fitting and fixing vitreous white glazed earthen ware wash hand basin of parry or hindustan or athor i s s approved do do ...........E/I |
| 75 | Providing and fixing PTMT bib cock of approved quality and colour 15 mm nominal bore, 122mm long, weighing not less than 99 gms |
| 76 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) 110mm dia Single socketed pipes. |
| 77 | Single Tee110x110x110 mm |
| 78 | Bend 87.5°110 mm bend |
| 79 | shoe Plane |
| 80 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. 15 mm nominal |
| 81 | 25 mm dia |
| 82 | Exposed on Wall 25 mm dia |
| 83 | polyethylene water storage tank, marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. |
| 84 | Supply of 12 mtr. High Mast in one section Construction S355 grade as per BS-EN 10025 Top Dia 100mm, bottom dia 360mm, plate thickness 3mm, 12 side polygon galvanisation as per BS-EN ISO 1461, base plate dia 520mm, base plate thickness 25mm, GI single spike lighting protection, maximum wind speed 47 m/s with 6 nos. foundation bolt of PCD 445mm TS 600/24mm dia/850 mm long. Luminaires carriage:Material for 40 NB ERW Class B- M.S. Pipe, dia of carriage ring 450mm (ID) with 8 arm, welded, 2 sections having carrying capacity upto 8 luminaries. Trailing cable : 5 core 2.5 sqmm. PVC flexible copper conductor winch / Power Tool : Double drum, SWL 350 kg with 0.75 HP 6 pole single speed intergal motor Rope: Grade AISI 304, 7/19 construction, dia 5mm, BLC 1450 x 2 having 2 nos. of continues rope, Aviation obstruction light: twin dome aviation obstruction lights LED type as required. (Basic Rate: 1,31,000.00+Over Head & [email protected]% = Rs. 1,50,584.50 ) |
| 85 | For 12 mtr. High mast: ITC of the high mast and light fixture with the help of suitable tools and plants, wiring of luminaries with all wiring material like PVC insulated PVC sheathed flexible cable of suitable copper conductor lugs. MCB and all labour & construction of shallow foundation with M25 grade concrete for the high mast considering safe soil bearing capacity of 10T/mtrs sq. for 12 M High Mast (Basic Rate: 68,990.00+Over Head & [email protected]% = Rs. 79,304.00) |
| 86 | LED FLOOD Light 240W(Basic Rate: 17053.00+ CP@10% |
| 87 | Outdoor stand mounted Feeder Panel with 63A TP&N, MCB incomer, 63 amp TP contactor automatic switching of luminairies, Power tool control incommer outgoing terminal etc. as required (for high mast) (Basic Rate: 27,800.00+Over Head & [email protected]% = Rs. 31,956.00 ) |
| 88 | Supply of 4C x 16 sqmm Aluminum Armored XLPE Cable (Basic Rate: 221.00+Over Head & [email protected]% = Rs. 254.00 ) |
| 89 | laying of one number PVC insulated and PVC sheathed / XLPE power cable 1.1 KV grade of size not exceeding 35 sqmm direct in ground including excavation and refilling the trench etc. as required, but excluding sand cushioning and protective covering |
| 90 | Earthing with GI earth pipe 4.5 mtr. Long, 40mm dia including accessories, and providing masonary enclouser with cover plate having locking arrangement and watering pipe etc. with charcoal and salt as required |
| 91 | Supplying and laying 6 SWG GI wire at 0.5 m below ground level for conductor earth electrode, including soldering etc. as required |
| 92 | 1.5 Hp AC motor with forward and reverse motion for high mast |
| 93 | Cost of Driling 200 mmx165mmx125 mtr.deep bore well in all kind of Soil and rock in rural area for instalation of pump set with Hydrolic DTH Rig machine all complete including all materials, tools,driling rig,air compressureand equipmentsas well as fule, lubricantsand cost of transportation of rig machine annd other vehical up to Site.(a) From 0.00 M to 50.00 M below G.L. |
| 94 | (b) From 51.0 M to 150.00 M |
| 95 | Supplying, assembling, lowering and fixing in vertical position in bore well, unplasticized PVC medium well casing (CM) pipe of required dia, conforming to IS: 12818, including required hire and labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer -in-charge.200 mm nominal size dia |
| 96 | Development of tube well in accordance with IS : 2800 (part I) andIS: 11189, to establish maximum rate of usable water yield withoutsand content (beyond permissible limit), with required capacity aircompressor, running the compressor for required time till well isfully developed, measuring yield of well by \\"V\\" notch method or anyother approved method, measuring static level & draw down etc. bystep draw down method, collecting water samples & getting testedin approved laboratory, i/c disinfection of tubewell, all complete,including hire & labour charges of air compressor, tools & accessoriesetc., all as per requirement and direction of Engineer-in-charge |
| 97 | Providing and fixing suitable size threaded mild steel cap or spot welded plate to the top of bore well housing/ casing pipe, removable as per requirement, all complete for borewell of:200 mm dia |
| 98 | Providing and fixing M.S. clamp of required dia to the top of casing/ housing pipe of tubewell as per IS: 2800 (part I), including necessary bolts & nuts of required size complete.200 mm clamp |
| 99 | Supplying 100mm dis submersible pump sets confirming to 8034 and motor confirming to IS 9283 pump shall be suitable for various delivery head and discharge with stainless steel pump shaft and polypropylene/noryl impeller. Motor suitable for working on 415 + 10, 3HP, 50 Hz, AC supply with cable guard, thurst carbon/fiber bearing to withstand entire hydraulic thurst, water proof winding shall be provided. The pump set shall be suitable for diret coupling Pump shall have suitable outlet as per manufacturers design. Anti thurst stream lined non return valve shall be provided with pump, 3 meter submersible copper conductor cable in single/double run shall be provided with each pump. Submersible pump set 100mm dia (with Polypropylene/Noryl Impeller) up to 20 stages 2 HP |
| 100 | Chlorinated Polyvinyl - chloride (CPVC) pipe 32 mm nominal dia |
| 101 | 3 Core 4 Sqmm copper wire |
| 102 | Carriage of materials.(i) Cement+steel |
| 103 | (ii) Sand |
| 104 | (iii) Stone Chips |
| 105 | (iv) Brick/Paver Block |
| 106 | (v) Dust |
| 107 | Add GST @ 18% |
| 108 | Add L.Cess @ 1% Please Enable Macros to View BoQ information |