| 1 | Cement Concrete (1:3:6) with 4cm size hard granite metal in Foundation and Plinth. |
| 2 | Fly ash brick masonry using fly ash bricks of size 23 cm. x 11 cm. x 8 cm. having crushing strength not less than 75 kg. Per Sqr. Cm. in cement mortar of mix (1:6) with cement after immersing the bricks for 6 (Six) hours in water before use in superstructure including splays cutting, circular moulding, corbelling, chamfering and similar such type of works, watering and curing etc. including cost, coveyance, loading and unloading, royalties and taxes of all materials and cost of all labour, scaffolding, sundries, T&P required for the works etc. complete in all respect as directed by the Engineer-in-charge Ground Floor |
| 3 | First Floor |
| 4 | Second Floor |
| 5 | 16mm thick cement plaster (1:6) over brick work including watering curing cost of al material and labour etc complete Ground Floor |
| 6 | First Floor |
| 7 | Second Floor |
| 8 | 12 mm thick cement plaster (1:6) over stone masonary including watering curing cost of all material and labouretc complete Ground Floor |
| 9 | First Floor |
| 10 | Second Floor |
| 11 | Providing, Fitting & Fixing of 8 mm. to 12mm. thick Vitrified Tile ( of size 600m.m x 600 m.m ) or equivalent make of printed series confirming to IS specifications having minimum breaking strength 1400 kg/sq.cm in flooring in all floors at all heights on 20mm thick bed of cement mortar(1:4) to proper slope, line and level including cutting to required size and shape, fixing at corners and splays etc. including filling the joints with silicon sealant to match the shade of Vitrified Tile as per the design & drawing including cost, conveyance, loading, unloading, stacking,royalties and taxes of all materials, cost of all labour, T & P, sundries, watering & curing etc. required for the work complete in all respect as directed by the Engineer-in-Charge. Ground Floor |
| 12 | First Floor |
| 13 | Supplying and Fixing of M.S. Window Grill made out of M.S Flat conforming to IS 2062/2006 painted with Red Oxide Primer as per the design approve by E.I.C including cost,conveyance of all materials, priming,and labour for fitting fixing etc.complete as per the instruction of Engineer-in-Charge Ground Floor |
| 14 | First Floor |
| 15 | Second Floor |
| 16 | Wall Painting two coats with approved Plastic Emulsion Paint over a coat of Water Bound Wall cement Primer on Plastered Surface in Ground Floor |
| 17 | First Floor |
| 18 | Second Floor |
| 19 | Finishing walls with water proofing Weather coat of approved shade on new work two coat to give an even shade inculding cost of paint.reguired for the work complete. Ground Floor |
| 20 | First Floor |
| 21 | Second Floor |
| 22 | Painting 2 Coats to the new surface of wood and iron work with one coat with primer and two coat with any approved shade of paint including all cost etc complete Ground Floor |
| 23 | First Floor |
| 24 | Second Floor |
| 25 | Supplying, fitting afixing of stainless steel of 304 grade in hand railing in all floors using 50mm dia of 2mm thick circular pipe with Balustrade of size 32mm x 32mm @ 0.90mtr. C/C and stainless square pipe bracing of size 32mm x 32mm x 2mm in 3 rows in stair case as per approved design and specification, buffing, polishing etc. with cost conveyance, taxes of all materials labour, T&P etc. required for the complete in all respect. Ground Floor |
| 26 | Reinforced Cement concrete (1:1.5:3) with 12mm size hard granite chips including cost, conveyance, royality, taxes, watering and curing etc. complete. (Column Super Structure) |
| 27 | Roof Slab |
| 28 | Lintel Band |
| 29 | Door Chajja |
| 30 | Water Tank Base |
| 31 | 2.5 cm thick Grading Conc with C.C. (1 : 2 : 4) (FOR OLD WORK )over roof slab using 12mm size &down graded c.b. chips with WeldedMess including cost carriage of all materials labour T&P etc. complete. |
| 32 | Supplying fitting and placing uncoated HYSD bar reinforcementcomplete asper drawing and technical specification. Please Enable Macros to View BoQ information |