| 2 | For Providing Annual Maintenance Contract (CMC) & Operation of Electrification Installation at Kamla Nehru Hospital Gas Rahat Bhopal (For One Year)(Detail Schedule Attached) SECTION 4 BILL OF QUANTITIES (BOQ) General Description of work: For Providing Annual Maintenance Contract (CMC) & Operation of Electrification Installation at Kamla Nehru Hospital Gas Rahat Bhopal (For One Year) 1st Call. P. A. C. 2290394.00 on Electrical SOR 01-01-2024, Completion period 365 Days (i/c rainy season) Probable Amount of Contract : (Rs. In Figure) :- 2290394.0 (Rs. In Words) :- Twenty Two Lakh Ninety Thousand Three Hundred Ninety Four Only SOR.No Particulars of Item of Work Quantity Unit Rate Amount (in figure) Amount (in words) Remarks I II III IV V VI VIII IX PART A (Material /Work Required During AMC as per Requirement of Director KNH) NOTE- Replacement of lights , fan , and point/power Wiring will be done after approval from director KNH or KNH Officials ) and all other material will bw replaced as per necessity and direction from PWD dept. officials (Sub Eng , SDO, EE) |
| 3 | Point wiring (excluding metallic switch box & sheet but including switches, sockets, lamp holders/ceiling roses etc) with 1.5sq. mm. PVC insulated cable FRLS with copper multi strand conductor ISI marked in surface rigid P.V.C. conduit (MMS) ISI marked of suitable size and 1.5sq. mm. PVC FRLS insulated copper earth continuity conductor of green colour inside conduit etc. as required as per specification for :- 3.1.1 Light point/fan points. 3.1.1.1 Primary short point 15.0 Each 408.0 6120.0 3.1.1.2 Primary medium point 15.0 Each 729.0 10935.0 3.1.1.3 Primary long point 15.0 Each 1141.0 17115.0 3.1.2 (Light point/fan points) looping point 3.1.2.1 Secondary short point 15.0 Each 204.0 3060.0 3.1.2.2 Secondary medium point 15.0 Each 365.0 5475.0 31..2.3 Secondary long point 15.0 Each 571.0 8565.0 3.1.3 3 Pin 6 Amp socket outlet on separate board 3.1.3.1 Short point 10.0 Each 540.0 5400.0 3.1.3.2 Medium point 10.0 Each 933.0 9330.0 3.1.3.3 Long point 10.0 Each 1379.0 13790.0 |
| 4 | Point wiring (excluding metallic switch box & sheet but including switches, sockets) for 3 pin 6 Amp. Socket outlet point with 1.5sq. mm. PVC insulated cable FRLS with copper multi strand conductor ISI marked in surface rigid P.V.C. conduit (MMS) ISI marked of suitable size and 1.5sq. mm. PVC insulated copper earth continuity conductor of green colour inside conduit with required materials as per specification on same board. |
| 5 | Wiring for circuit wiring with PVC insulated cable FRLS with copper multi strand conductor ISI marked in surface rigid P.V.C. conduit (MMS) of ISI marked suitable size etc. as required as per specification 3.3.1 2x2.5 Sq.mm. 15.0 Metre 122.0 1830.0 3.3.2 4x2.5 Sq.mm. 20.0 Metre 202.0 4040.0 3.3.3 6x2.5 Sq.mm. 20.0 Metre 267.0 5340.0 |
| 6 | Point wiring (excluding metallic switch box & sheet) for 3 Pin 16 Amp. socket outlet point with 4sq. mm. PVC insulated cable FRLS with copper multi strand conductor ISI marked in surface rigid P.V.C. conduit (MMS) ISI marked of suitable size etc. with 20/16 Amp. F.T. switch & socket/S.S. combined 20/16/6 Amp. of ISI marked and 4sq. mm. PVC insulated FRLS copper earth continuity conductor of green colour inside conduit, screwless connector for joints as per specification for :- 8.1.1 On separate board 8.1.1.1 Short point 10.0 Each 845.0 8450.0 8.1.1.2 Medium point 10.0 Each 1468.0 14680.0 8.1.1.3 Long point 10.0 Each 2183.0 21830.0 8.1.1.4 Extra long -I 10.0 Each 3069.0 30690.0 8.1.1.5 Extra long -II 10.0 Each 4045.0 40450.0 8.1.1.6 Extra long -III 5.0 Each 5033.0 25165.0 |
| 7 | Same board switch & socket 16 Amp./S.S. combined 20/16/6 Amp |
| 8 | Supplying and fixing PVC conduit as required confirming to IS 9537 (Part-3), ISI marked along with accessories on surface etc. as required. 15.1.1 PVC conduit 20 mm. (MMS) 35.0 Metre 51.0 1785.0 |
| 9 | Supplying & installation of approved make required capacity 3 phase, 50 Hz, 415V, centrifugal mono-block pump, with starter i/c single phase preventer, connections, base channel foundation etc. as required as per specifications but excluding pipe and connection cable. 39.9.6 20.0 HP head metre 32-52, discharge LPM 2400-1200 1.0 Each 125833.0 125833.0 |
| 10 | Supplying and fixing of approved make modular type G.I. metal box 1.2mm minimum thick and depth 50mm for single row boxes and 60mm depth for two/three row boxes earth terminal stud with nut and washer with modular base and cover plate including fixing in concealed etc. as required for:- 18.2.2 3 Module metal box 11.0 Each 216.0 2376.0 18.2.4 6 Module metal box 15.0 Each 309.0 4635.0 18.2.5 8/9 Module metal box 10.0 Each 373.0 3730.0 18.2.6 12 Module metal box 15.0 Each 502.0 7530.0 18.2.8 18 Module metal box 10.0 Each 642.0 6420.0 |
| 11 | Supplying and fixing of approved make modular type PVC box minimum depth 40mm and minimum thickness 2mm with modular base and cover plate including fixing on surface etc. as required for:- 18.3.2 3 Module PVC box 12.0 Each 177.0 2124.0 18.3.4 6 Module PVC box 18.0 Each 254.0 4572.0 18.3.5 8/9 Module PVC box 10.0 Each 314.0 3140.0 18.3.6 12 Module PVC box 18.0 Each 402.0 7236.0 18.3.7 16 Module PVC box 10.0 Each 442.0 4420.0 |
| 12 | Supply of ISI Marked Automatic Star-Delta Starters confirming to IS : 13947-4 with suitable over load relay range and contactor size & timer 415 V , 3 -Phase with two earthing terminals 25.13.2 15.0 HP 1.0 Each 8009.0 8009.0 25.13.3 20 HP 1.0 Each 9079.0 9079.0 |
| 13 | Supply of ISI marked and approved make of moulded case circuit breaker (MCCB) suitable for 3 phase,3 pole, 50 Hz, 415 Volts, AC supply with respective interrupting capacity (KA) at 415 Volts cited against their range standard conforming to IS – 8828 27.1.2 MCCB current rating -80 to 100Amp, 10kA, 3P 415V AC 0.0 Each 3256.0 0.0 27.1.3 MCCB 25kA current rating, 3P -25 to 100Amp & 80% -100% adjustable 2.0 Each 7369.0 14738.0 27.1.4 MCCB 25kA current rating, 3P -125Amp & 80% -100% adjustable 2.0 Each 9953.0 19906.0 27.1.5 MCCB 25kA current rating, 3P -160Amp & 80% -100% adjustable 2.0 Each 12701.0 25402.0 27.1.6 MCCB 25kA current rating, 3P -200Amp & 80% -100% adjustable 2.0 Each 16061.0 32122.0 |
| 14 | Supply of ISI marked and accepted standard of miniature circuit breaker (MCB) of 'C' series with short circuit indication, suitable for 240/415 Volts,50 Cycle, 10 kA/15 kA Value AC supply conforming to IS : 8828 : 1996, IEC : 60898 :2002 & 60947-2 but without enclosures :- 27.8.1 Single pole 27.8.1.2 MCB SP 6Amp to 32Amp 10kA rating 55.0 Each 263.0 14465.0 |
| 15 | Supplying of MCB Isolators suitable for 240/415 Volts, 50 Hz AC supply with kA value rating 10 kA of approved make conforming to IS:13947-Part III :1993 & IEC:60947- 3:2001 (without enclosures ) :- 27.10.4 Four pole 27.10.4.2 Current rating upto 63Amp 6.0 Each 1398.0 8388.0 |
| 16 | Supplying of approved make TPN MCB DB metal double door IP 43 protection with provision for FP MCB/ Isolator/ RCCB/ RCBO as incomer and SP MCBs as outgoing inclusive of busbar, neutral bar, earth bar, connection copper wire not less than 16 sq.mm & two earth terminals etc. complete as per IS:13032(exclusive of MCB & isolator): 27.12.1 4 Way (4+12) 2.0 Each 5126.0 10252.0 |
| 17 | Fixing of MCB/MCCB/Isolator in sheet steel enclosure as required as per accepted practice, including mounting on busbar and cable connection etc. complete (labour only) 28.4.1 MCB/Isolator SP/DP 45.0 Each 22.0 990.0 28.4.2 MCB/MCCB Isolator TP/TPN/FP 15.0 Each 28.0 420.0 |
| 18 | Labour charges for fixing sheet steel enclosure, MCB DB surface mounting type, as per accepted practice on 25x5mm flat iron clamp duly embedded in wall, cable connection etc. complete. For item no :- 28.5.1 27.11.1 to.27.11.4 2.0 Each 517.0 1034.0 |
| 19 | Supply and fixing of multi core round FRLSH PVC insulated copper (flexible) conductor & PVC sheathed cables 1100Volts as per IS:694-1990 of approved make 29.6.1 (16/0.2 mm)Three core 0.5 sq.mm. 25.0 Metre 20.0 500.0 29.6.2 (24/0.2 mm) Three core 0.75 sq.mm. 25.0 Metre 25.0 625.0 |
| 20 | Supply and fixing as per specification Switch of approved make ISI marked with necessary material complete. 29.9.1 6Amp SP 250 Volt deluxe (piano key type) 50.0 Each 18.0 900.0 29.9.2 16/20Amp SP 250 Volt deluxe (piano key type) 50.0 Each 68.0 3400.0 29.9.4 6/10Amp SP 250 Volt modular switch 50.0 Each 48.0 2400.0 29.9.5 16/20Amp SP 250 Volt modular switch 50.0 Each 89.0 4450.0 |
| 21 | Supply and fixing as per specification socket outlet of approved make & ISI marked with necessary material complete |
| 22 | 16Amp 250 Volt 3 Pin flush type 29.10.3 10Amp 250 Volt 3 Pin modular type 15.0 Each 98.0 1470.0 |
| 23 | Supply and fixing of MPP condenser 440 Volt single phase of approved make as required as per specification 29.16.1 Condenser 2.5 mfd 440Volt 25.0 Each 53.0 1325.0 29.16.2 Condenser 3.15 mfd 440Volt 25.0 Each 61.0 1525.0 |
| 24 | Supply and fixing of ball bearing of approved make as required as per specification 29.22.1 6201.0 25.0 Each 155.0 3875.0 29.22.2 6202.0 25.0 Each 165.0 4125.0 29.22.3 6203.0 12.0 Each 176.0 2112.0 29.22.4 6204.0 25.0 Each 207.0 5175.0 |
| 25 | Supply and fixing of approved make flush type step type electronic fan regulator including connection etc. as required on existing board 29.23.1 100 Watt 10.0 Each 169.0 1690.0 |
| 26 | Supply and fixing of approved make step type modular electronic fan regulator including connection etc. as required on existing board 29.25.2 100 Watt(2 module) 10.0 Each 484.0 4840.0 |
| 27 | Supplying, erection and testing of approved make electric Ceiling fan of double ball bearing complete with standard down rod, canopy, hanging shackle, Aluminium blades, without regulator, A.C. 230-250 volts including connections with all necessary material complete of approved as required confirming to IS :374/2019 with upto date amendments. 30.1.1 Ceiling fan - 900 mm sweep Each 1898.0 0.0 30.1.2 Ceiling Fan (ISI marked)-1200 mm Sweep, with minimum air delivery 210 m³/min and service value ≥ 4.00 as per BEE.. 10.0 Each 2292.0 22920.0 |
| 28 | Supplying, erection and testing of approved make wall mounting fan oscillating type with base, blades, guard, speed regulator etc. AC 230-250 volts with connections and including raw bolt/anchor hole fastener etc. complete finished and as required. 30.2.2 400 mm sweep 4.0 Each 2810.0 11240.0 |
| 29 | Supplying, erection and testing of approved make 'Fresh air fan' AC 230-250 volts with connection and including frame bolt/anchor hole fasteners etc. complete finished and as required. 30.4.3 300 mm sweep bush type 4.0 Each 1698.0 6792.0 |
| 30 | Supply and fixing Led tube rod comprising of LED tube with non-integral/integral driver, upto 6500K color temp having 40000 burning hrs life with minimum @ L 70, system lumen output should be minimum with system efficacy> 100 lm/Watt. LED driver PF> 0.95 & THD < 20%. The colour rendering index of LED light should be more than 70. Submission LM 79-08/IS16106 (2012), IEC60598, IEC61347i/c connection wire, testing etc. to complete the job. 31.3.4 Tube light LED 1 X 20/22Watt, Integral i/c batten aluminium body, PC diffuser. 50.0 Each 782.0 39100.0 31.3.5 LED retrofit glass tube i/c driver only 20/22Watt,color temp 3000 - 6000K without box suitable for replacing existing 36/40Watt FTL 50.0 Each 763.0 38150.0 |
| 31 | Supplying Fixing and testing of approved and suitable make LED driver for an existing LED luminary panel. 31.24.1 LED Luminiare 1'x1', 24W Panel Driver 12.0 Each 558.0 6696.0 31.24.2 LED Luminiare 2'x2', 36W Panel Driver 10.0 Each 670.0 6700.0 |
| 32 | Rewinding of fans by copper enameled wire of suitable gauge including all required material, insulation, varnishing, connection leads, oiling .greasing etc complete with testing including dismantling & refitting of fan at site. Scrap old material is not returnable to the department. 32.13.1 Ceiling fan 1400 mm sweep old model/exhaust fan 450 mm sweep 10.0 Each 1064.0 10640.0 32.13.4 Ceiling fan 1200 mm sweep new model/exhaust fan 300 mm sweep 50.0 Each 637.0 31850.0 32.13.5 Fresh air fan up to 300 mm sweep/wall bracket/cabin fan 400 mm sweep 10.0 Each 507.0 5070.0 |
| 33 | Cleaning, overhauling, servicing of ceiling/exhaust/wall bracket fan by applying grease & oil, including testing with mounting/hanging arrangement including replacement of safety pins, check nuts, lock nut, nut bolts etc. making perfect alignment & refitting at site as required. |
| 34 | Supply of XLPE insulated power cable (conforming IS-7098 Part-I) 1100 Volt grade, 1 core/2 core/3½ core/4 core ISI marked with alu. stranded /solid conductor 41.1.4 Armoured 2 core 41.1.4.5 16 sq. mm. 50.0 Metre 131.0 6550.0 41.15.31 Laying of one number armoured/unarmoured cable 1.1KV grade of size not exceeding 25 sq. mm on surface in existing trench etc. as required. 50.0 Metre 25.0 1250.0 PART A TOTAL Rs. 799416.0 PART B (OPERATION , Electrical Staff, Round the clock) The Work of Operation Staff- all the electrical fault will be repaired instantly also wires pieces , material required for making wire /cable joints etc will be under scope also the tools and plant required for electrical work will be provided by the contractor ) Wireman 03 Nos. x 12 Month 36.0 Per Month 19259.0 693327.0 Helper 03 Nos. x 12 Month 36.0 Per Month 15737.0 566542.0 Reliever Wireman (1)Nos. x 12 Month 12.0 Per Month 19259.0 231109.0 SUB TOTAL B Rs. 1490978.0 SUB TOTAL A + SUB TOTAL B Rs. 2290394.0 Executive EngineerPWD E/M Division No. 1, Bhopal |