| 1 | Dismantling wrought iron or mild steel work of any description not otherwise specifically provided for complete all as specified and as directed. |
| 2 | Dismantling Plain or corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern roof coverings complete all as specified and as directed. |
| 3 | S&F prepainted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50 mm thick of an colour having tensile strength 550 MPA as in roof covering in roof covering /cladding to wall, fixed with self tapping screws including providing of rubber washer/Bitumen washer with filling of Bitumen between joint of sheet and Self tapping screws complete all as specified. |
| 4 | All as per item No 3.00 above except sheeting but fixing only. |
| 5 | S&F prepainted galvalume aluminium zinc coating GI based plain steel sheet 0.50 mm thick of an colour having tensile strength 550 MPA as in roof covering in roof covering /cladding to wall, fixed with self tapping screws including providing of rubber washer/Bitumen washer with filling of Bitumen between joint of sheet and Self tapping screws complete all as specified. |
| 6 | S&F in repair PVC (SWR) pipes 110 mm dia. single socketed, in any length with rubber ring joints, fixed to wall and roof as in rain water gutters including cutting of PVC pipes in half complete all as specified and as directed. |
| 7 | Supply and fix rolled mild steel in roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats conforming to Fe-290(Gde E-165) quality A complete all as specified and as directed. |
| 8 | M&L for MS work as in Wind Tie in roof and MS structural works in trusses, etc with screwed ends including nuts, washers and mild steel plates for walls chimneys, roofs arches etc any kind rods and straining bolts conforming to Fe 290 Gde E-165 complete all as specified . |
| 9 | Demolition of brick work / stone boulder / PCC block masonary, built in cement mortar or cement lime mortar including all quoins, arches pillars, etc but excluding ashlar facing, dressed stone works, precast concrete articles and precast concrete block wallings complete all as specified and as directed. |
| 10 | M&L for Pre-cast cement concrete block masonry with solid blocks using type C1(1:3:6) (20mm graded aggregate) ,size exc 10cm in width and setting in cement mortar 1:6 complete all as specified and directed. |
| 11 | Taking down cement plastering on concrete or Brick works surface racking out joints, hacking for key , scrubbing down with water, removing rubbish/debris etc complete all as specified and as directed. |
| 12 | Material and labour for rendering 10mm thick in Cement Mortar 1:6 on fair faces of brick walls or on concrete surfaces, finished even and smooth,without using extra cement complete all as specified and directed. |
| 13 | Material and labour for 15 mm thick rendering on brick/concrete surfaces in two layers in CM 1:4, finishing coat of 5mm thick, finished even and smooth without using extra cement complete all as specified and as directed. |
| 14 | Material and Labour for rendering 5 mm thick in cement mortar 1: 3 on fair faces of concrete surfaces of ceiling finished even and smooth with out using extra cement, complete all as specified. |
| 15 | Material and labour for preparation of new or previously untreated steel surface over 10 cm width or girth and applying two coats of synthentic enamel paint over a coat of red oxide primer complete all as specified and directed. |
| 16 | Material and labour for preparation of of new plastered/concrete surfaces of walls and applying two coats of acrylic distemper of approved shade/tint over a coat of primer, over surface of wall all as specified and as directed. |
| 17 | Material and labour for applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces complete all as specified and directed. |
| 18 | Material and labour for preparation of of new plastered/concrete surfaces of ceiling and applying two coats of acrylic distemper of approved shade/tint over a coat of primer, over ceiling surfaces all as specified and as directed. |
| 19 | Taking down existing roof treatment of any description and removing the debris materials to a distance exceeding 100mtr but not exceeding 250 mtr all as directed by Engineer in Charge. |
| 20 | Demolition cement concrete (unreinforced) to Roofs, floors (other than ground floors), beams, staircases, landing, chajjas, and similar suspended work complete all as specified and as directed by the Engineer-in-Charge. |
| 21 | M & L for providing cement concrete 1:2:4 Type B0 using 12.5mm graded aggregate as in roof kerbs or mud stops, rounded or chamfered on edges complete all as specified and as directed by the Engineer-in-Charge. |
| 22 | M & L Cement concrete 1:2:4 type B-0 using 12.5 mm graded stone aggregate as in roof padding in levelling course, benching etc, finished even & rough to receive cement mortar screed bed complete |
| 23 | M& L for preparation of naked roof surface by cleaning dust & dirt and applying 15 mm thick rendering in cm(1:3) mixed water proofing compound @ 3% by weight of cement or as per manufactures instructions, finished even and smooth surface all as specified and directed by Engineer in Charge. Note - WPC shall be measured & Paid separately. |
| 24 | Supply only integral water proofing compound of approved quality all as specified. |
| 25 | M&L for water proofing treatment to RCC roof slab including parapet comprising with the following course of treatment/ specifications from bottom to top:- (a) Applying bituminous primer @ 0.40 ltrs per sqm over plastered surfaces of roof including parapet surfaces.(b) One layer of APP based polymeric membranes of approved manufacturers, 3 mm thick, weight not less than 3.6 kg/sqm, reinforced with non woolen polyester fabric or weight not less than 150 gms/sqm. Polymeric membrane shall be taken to a height of 60 cm (minimum) and then inserted inside the groove of parapet walls and shall be finished by a membrane flashing.Note: (i) Laying of APP based membranes shall be done by torch on method or as per manufacturer's instructions.(ii) A minimum overlap of 100 mm and 75 mm should be made in the end sides of polymeric membranes respectively and sealed all overlaps and joints as manufacturer's instructions.(c) Applying two coats of Aluminium paint on top of APP membranes. |
| 26 | Schedule of Credit (Minus) Rs.52650.00 NOTE: Bidder shall insert credit amount of Rs. 52650.00 as rate in Green field under Col-13. Please Enable Macros to View BoQ information |