| 1 | Providing and Fixing Vertical Blinds of approved Make and shade of 100mm regular fabric with powder coated aluminium channel with telting PVC chain & bottom weight plate with all necessary fixtures and fitting etc. complete. (Sample to be final by Engineer In-charge prior execution of work |
| 2 | Providing and fixing in position. (as per I.S.1868 / 1982) Aluminium sliding window of two tracks with rectangular pipe having overall dimension ?63.50x38.10x1.02 mm at weight 0.547 Kilogram/ One Running Metre. And window frame bottom track section 61.85x31.75x1.20mm atweight 0.695 Kilogram/ One Running Metre. Top and side track section 61.85x31.75x1.30mm at weight 0.659 Kilogram/ One Running Metre. The shutter should be of bearing bottom 40x 18x1.25mm at weight 0.417 Kilogram/ One Running Metre. Inter locking section 40x18x1.10 mm at weight 0.469 Kilogram/ One Running Metre. And handle section 40x18x1.25mm at weight 0.417 Kilogram/ One Running Metre. And top section40 x 18 x 1.25mmat weight 0.417Kilogram/ Running metre. As per detailed drawings and as directed by Engineer in charge with all necessary Aluminium sections fixtures and fastenings such as roller bearing in nylon casting and self locking catch fitted in vertical section of shutter including 5mm thick plain glass with all required screws and nuts etc, complete. With powder coating without box |
| 3 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade : One or more coats on old work. |
| 4 | Providing and applying white cement based putty of average thickness 1mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete |
| 5 | Distemperingwith1stqualityacrylicdistemper (ready mixed) having VOC content less than 50 gram/litre, of approved manufacturer, of required shade and colour all complete : New work (two or more coats) over and including water thinnable priming coat with cement primer having VOC content less than 50 gram/litre |
| 6 | Providing and fixing false ceiling at all height including providing and fixing of frame work made of special sections, power pressed from M.S. sheets and galvanized with zinc coating of 120 gms/ sqm (both side inclusive) as per IS : 277 and consisting of angle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37mm, at 1200 mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5 mm dia x 50mm long with 6mm dia bolts, other flange of cleat fixed to the angle hangers of 25x10x0.50 mm of required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate G.I. channels 45x15x0.9 mm running at the spacing of 1200 mm centre to centre, to which the ceiling section 0.5 mm thick bottom wedge of 80 mm with tapered flanges of 26 mm each having lips of 10.5 mm, at 450 mm centre to centre, shall be fixed in a direction perpendicular to G.I. intermediate channel with connecting clips made out of 2.64 mm dia x 230 mm long G.I. wire at every junction, including fixing perimeter channels 0.5 mm thick 27 mm high having flanges of 20 mm and 30 mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450 mm centre, with 25mm long dry wall screws @ 230 mm interval, including fixing of gypsum board to ceiling section and perimeter channel with the help of dry wall screws of size 3.5 x 25 mm at 230 mm c/c, including jointing and finishing to a flush finish of tapered and square edges of the board with recommended jointing compound , jointing tapes , finishing with jointing compound in 3 layers covering upto 150 mm on both sides of joint and two coats of primer suitable for board, all as per manufacturer's specification and also including the cost of making openings for light fittings, grills, diffusers, cutouts made with frame of perimeter channels suitably fixed, all complete as per drawings, specification and direction of the Engineer in Charge but excluding the cost of painting with : 12.5 mm thick tapered edge gypsum plain board conforming to IS: 2095- (Part I) :2011 (Board with BIS certification marks) |
| 7 | Providing and fixing 1.5 mm thick polyvenylvenyl chloride flooring including leveling the bas ewith white cement including pasting with appropriate material cleaning the surface etc. complete |
| 8 | Providing and erecting a 450 mm sweep oscillating type wall-mounted air circulator fan operating at 1440 RPM without a speed regulator, fitted with an overheat protection unit. The fan shall have a totally enclosed, flame- roof motor suitable for 230/250 volts single-phase, 50 cycles alternating current supply. It shall be provided with one metre of three-core lead wire, moisture-proof treatment to the windings, and Class E insulation. Each unit complete as specified. |
| 9 | Providing and fixing chromium plated brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc. complete Please Enable Macros to View BoQ information |