Sales : +91-777 804 8217
| Sl. No. | Item Description |
| 1 | PART-I : (B/R WORKS) Taking down chowkats with shutters (without taking off shutter from the frames) not exceeding 1.50 Sqm each complete all as specified and directed. |
| 2 | Taking down chowkats with shutters (without taking off shutter from the frames) exceeding 1.50 Sqm but not exceeding 4.00 Sqm each complete all as specified and directed.(Note for Item No. 1.00 & 2.00 - Rate shall be deemed to be include for cutting holes/demolition of masionry walls etc for taking down chowkats and making good the damaged surfaces). |
| 3 | Demolition of brick work or stone/boulder masonry, built in cement mortar including all quoins, arches, pillar etc complete all as specified and directed. |
| 4 | Demolition of unreinforced cement concrete of any description and in any position not otherwise specifically provided for complete all as specified and as directed. |
| 5 | Demolition of reinforced cement concrete (reinforcement cut as required to facilitate demolition) of roofs, floors (other than ground floors), beams, stair cases, landing, chajja and similar suspended work complete all as specified and directed . |
| 6 | Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing) removing serviceable tiles to store and rubbish off the premises complete all as specified and directed. |
| 7 | Taking down cement plaster of any description on brick or stone or concrete surface of wall & celing etc including raking out joints, hacking for key, scrubbing down with water etc complete all as specified and directed. |
| 8 | Dismantling wrought iron or mild steel work of any description etc complete all as specified and directed. |
| 9 | Removing building materials and debris (other than excavated earth) to a distance of 5 KM inside MD Land at locations specified including loading and dumping/ levelling at the destination complete all as specified and as directed. |
| 10 | Taking down eaves gutters and rainwater pipes CI/PVC/AC soil pipe including all fittings, heads, shoes, bends, swan-necks, etc. (measured overall as fixed along the centre line over fittings and accessories) complete all as specified and directed. |
| 11 | Dismantling water tanks of capacity exc. 250 and not exc. 500 ltrs, complete all as per specified and as directed. |
| 12 | Taking up or down GI 15 mm bore pipe and connections, including cleaning for re fixing or removal from site as directed |
| 13 | Taking up or down GI 20 mm bore pipe and connections, including cleaning for re fixing or removal to store |
| 14 | Excavation in trenches not exceeding 1.5 mtr wide and not exceeding 1.5 mtr in depth for foundation or for shafts, well, cesspits, pier holes etc not exceeding 10 Sqm on plan and not exceeding 1.5 mtr in depth and getting out in soft/loose soil complete all as specified and directed. |
| 15 | Returning, filling in, including spreading leveling, watering and well ramming in layers not exceeding 25cm, soil complete all as specified and directed. |
| 16 | Excavating in post holes (or similar holes) in soft /loose soil each not exceeding 0.5 cum, getting out, returning filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25cm, watering and removing surplus soil to a distance not exceeding 50m and making good the surface complete all as specified and directed. |
| 17 | Surface dressing not exc. 15 cm deep in soft/loose soil, complete all as per specified and as directed. |
| 18 | Removing surplus excavated materials to a distance not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting points in soft/loose soil complete all as specified and directed. |
| 19 | Removing excavated materials (soils) exceeding 250 m but n exc. 500 m and deposited, complete all as specified and as directed. |
| 20 | M&L for hardcore of guage not exc. 63mm deposited, spread and levelled in layers not exc. 15 cm thick, watered and rammed to a true surface of broken stone or boulders, complete all as per specified and as directed. |
| 21 | M&L for RCC type A-1, 1:1.5:3 (20 mm graded aggregate) as in chajjas, beam, column, roof, landing, shelf, platform, facia and like, complete all as per specified and as directed. |
| 22 | M&L for cement concrete 1:5:10 type E-2 using 40mm graded aggregates as in filling/mass concrete in sunken portion of WC etc., complete all as specified and as directed. |
| 23 | M&L for PCC (1:2:4) type B-1 ( using 20 mm grade crushed stone aggregate) as in water tank platforms, filling and mass concrete, complete all as specified and as directed. |
| 24 | M&L for PCC 1:3:6 Type C2 (using 40mm graded crushed stone aggregate) as in foundation, filling and mass concrete complete all as specified and as directed. |
| 25 | M&L for PCC (1:4:8) type D-2 40mm graded stone aggregate as in foundation filling and mass concrete complete all as specified and directed. |
| 26 | M&L for providing plain cement concrete type B-0, 1:2:4, (using 12.5 mm graded stone aggregate), as in copings, bed block for filing hollow space of steel chowkhats, fixing of hold fast, kneelers, apex stones, bed plates, water troughs and the like including weathering, slightly rounded or chamfered angles & throating as directed including necessary form work, complete all as per specified and as directed. |
| 27 | M&L for PCC (1:3:6) type C-1 (using 20mm graded stone aggregate) as in copings, bed block for filling hollow space of steel chowkhats, fixing of hold fast, kneelers, apex stone, bed plates, water troughs and the like including weathering, slightly rounded or champfered angles and throating as directed including necessary form work as required complete all as specified and directed. |
| 28 | M&L for precast cement concrete (1:1.5:3) type A1 (using 20 mm graded crushed stone aggregate) as in landings, cover slabs (for man holes etc.) chullah hoods, chajjas, water troughs, mangers, shelves and similar articles with plain faces set in cement mortar 1:4, complete all as specified and as directed. |
| 29 | M&L for RCC (nominal Mix) type A-1, 1:1.5:3 (20 mm graded aggregate) as in foundations, including rafts, footings, foundation beams, plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete etc, complete all as per specified and as directed. |
| 30 | M&L for RCC M-20 type A-1, 1:1.5:3 (20 mm graded aggregate) as in Slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like etc, complete all as per specified and as directed. |
| 31 | M&L for RCC (nominal Mix) type A-1, 1:1.5:3 (20 mm graded aggregate) as in columns, pillars, piers, posts and struts etc, complete all as per specified and as directed. |
| 32 | Supply only integral water proofing compound confirming to IS complete all as per specified and as directed. |
| 33 | M & for water proofing treatment to sunken floor with the following course of treatment/ specification: (i) Cleaning top surface of floors /slabs and laying 50 mm thick (avg) PCC of grade M10 (Nominal mix) , mixed with WPC as per manufactrrer's instruction laid in slope 1:20 towards spouts including coveting corners(ii) 15 mm thick plastering in CM (1:4) on sides mixed with WPC as pe rmanufacturer's instruction.(iii) Applying 1st layer of slurry @ 0.488 kg / sqm mixed wth acrylic based polymer modified cementious compound @ 0.253 kg /sqm This layer shall be allowed to air cured for 4 hrs.(iv) applying 2nd layer of slurry @ 0.242 kg/sqm mixed with accrylic based polymer modified cementenous compound @ 0.126 kg/sqm.This layer shall be allowed to air cured for 4hrs followed with water curing for 48 hrs.(v) Applying a coat of industrial bitumen 85/25 penetration @ 1.50 kg/sqm on plastered and concrete surfaces(vi) Providing 150 micron thick polyutethene paint in two coats (each of 75 micron measured dry on dry surface over a coat of PU primer including preparation.(vii) 2 Nos 32mm bore GI medium grade 450mm long spout ,to be provided through external wall to drainout accumulated water.(viii) Sunken floor shall be tested for water tighness by filling water for 72 hrs before and after treatment work is carried out and ensure that no leakage /seepage exists(ix) Sunken portion shall be filled with lean concrete 1:4:8 type D2. |
| 34 | Material and labour for water proofing treatment with following application over roofs surface complete all as specified and directed : - (i) Applying bituminous primer at the rate of 0.4 Litres/Sqm on prepared surfaces of roof. Surface shall be kept free, till the primer is impregnated and the solvent oil in the primer get evaporated.(ii) Applying one coat of blown type bitumen of grade 85/25 as binding material at the rate of 1.2 Kg/Sqm.(iii) Laying 3mm thick APP polymeric water proofing membrane of weight not less than 3.0 Kg/Sqm, black finish reinforced with non woven polyester matt, with a thermos fusible finish, torching overlaps with a propane or a butane gas torch, with a overlap of 75mm at sides and 100mm at the ends and sealing including applying a coat of cold emulsion bituminous primer all as per manufacturers instruction including preparation of surface.(iv) Top of membrane shall be provide with solar reflective bituminous aluminium paint @ 0.1 Kg/Sqm as prescribed by manufacture of membrane.Note :- The water proofing treatment shall be carried out by the manufacturer or his authorised applicators in terms of clause 11.43 of MES Sch Part-I (2009). |
| 35 | Supply only integrated liquid water proofing compound complete all as specified and directed. |
| 36 | M&L for brick work with sub class 'B' bricks, straight or curved on plan exc. 6m mean radius in cement mortar 1:6, complete all as per specified and as directed. |
| 37 | M&L for brick work with fly ash old sized Bricks straight or curved on plan exc 6m mean radius built in Cement mortar 1:6, complete all as specified and as directed. |
| 38 | M&L for brick work with fly ash old sized Bricks straight or curved on plan in CM 1:4 as in half brick thick walls, complete all as specified and as directed. |
| 39 | Cutting chases, pinning in. making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc.; and cutting chases for concealed water tubing or concealed conduit wiring, etc., and making good, cutting not exc 10 cm girth, complete all as per specified and as directed. |
| 40 | M&L for 18 to 20 mm thick granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window-cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match the shade of granite stone including taking down cement plaster of any description including raking out joints, haking for key, scrubbing down with water etc, complete all as specified and as directed. |
| 41 | Cleaning of blocked man holes upto 60 cm depth by removing by removing of sludge from inside and removing to a distsnce exc 200m but not exc 500m and burried the same into earth pits including excavation of earth pits of required size and depth, depositing & spreading of sludge, returning in filling earth over sludge and removal of surplus soil to a distance not exc 50m, complete all as specified and as directed. |
| 42 | Providing formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams for flat Rough finishedconcrete surface complete all as specified and directed. |
| 43 | M&L for formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work not exceeding 200 mm thick (horizontal or sloping) including edges rough finished surface of concrete flat complete all as per specified and as directed. |
| 44 | Providing formwork to chullah hoods, chajjas, troughs and similar items including etc for Rough finished concrete surface complete all as specified and directed. |
| 45 | M&L for form work for side of squre, rectangular or polygonal pillars, posts, columns & similar works vertical or batter fair finished surfaces of concrete complete all as specified and as directed. |
| 46 | Use and waste of formwork to edges of rough finished surfaces of concrete flats, treads, breaks in floors, window cills, concrete railings, openings in concrete walls, floor and roofs n exc 20 cm wide and sides of RCC/ PCC bands in walls, horizontal or sloping and similar work exc 10cm but n exc 20cm wide, complete all as per specified and as directed. |
| 47 | M&L for 35 mm thick second class hardwood glazed and skeleton shutter open rebated and prepared to receive glass, gauge etc (without sash bar) edges of framing plain, chamfered or rounded fitted with cut and mitred beads for securing glass etc sizes of member (Bottom 250mm, stiles 100mm, top 120mm & lock rail 160mm wide) as specified in SSR part I section & clause 8.24 (a) complete all as specified and as directed. |
| 48 | S&F of 30 mm thick flush door shutters solid core construction with block board and plywood face panel, commercial type with both side etc complete all as specified and directed. |
| 49 | Supply and fixing factory made solid panel PVC door shutter 30mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails, M.S. .frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail,; Paneling of plain colour PVC sheet to be fitted in the M.S. frame welded/ sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement complete all as per specified and as directed. |
| 50 | S&F of factory made solid PVC door frame of size 50mm X 47mm made out of 5 mm thick plain colour PVC sheet reinforced with MS square tube as per specification and drawing, complete all as specified and directed. |
| 51 | S&F of 300 mm aluminum alloy, anodised , sliding door bolt with hasp and staple (bolt type ) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded section or cast aluminum alloy and fixed complete all as specified and directed. |
| 52 | S&F of 150mm long aluminium, anodised, barrel tower bolts of extruded section and fixed complete all as specified and directed. |
| 53 | S & F in repair MS 300 mm , ordinary rat tail rod pattern springs incl. roller platecomplete all as specified and as directed. |
| 54 | S&F Aluminium handles, 125 mm size cast type, anodised complete all as specified and directed by EIC. |
| 55 | S&F of 100 mm long stainless steel butt hinges, complete all as specified and directed. |
| 56 | S & F repair stainless steel curtain rods 25 mm dia , anodised aluminium alloy with fixing brackets ,stops, and complete fitments complete all as specified and as directed. |
| 57 | S&F of floor door stopper of aluminium alloy body and tongue, anodised with hard drawn steel spring, fixed in floor (overall length of cover plate 140mm) complete all as specified and directed. |
| 58 | S&F of PVC Corner shelves (3 Pieces set) fix to wall, complete all as specified and as directed. |
| 59 | S & F Stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staple complete all as specified and directed. |
| 60 | S&F Mild steel flats etc., as in supports for stiffening of fencing, wall ties, hold fasts, wind ties, clamps and similar small articles etc. conforming to Fe-290 Gde E-165, complete all as per specified and as directed. |
| 61 | S&F Framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165, complete all as specified and as directed. |
| 62 | S&F of mild steel flat iron as in Bands, straps, supports or stays for rainwater, ventilating pipes, including bolts,if required hooks (stay), heavy, for large gates; hook and pintle hinges large hasps and staples; chains; hand made sliding bolts; clamps; hold fasts; wall ties; hooks for hanging fans; plain angle cleats for securing purlins to wood trusses or rafters; knee piece inserts; two way and three way straps, plate washers and similar small articles conforming to Fe-290 Gde-E-165 complete all as specified and directed. |
| 63 | Mild Steel TMT bars 10 mm dia and over cut to length bent to shape as required including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed. |
| 64 | M&L for TMT bars 5mm dia and over upto and including 10mm dia in stirrups, spacers and binders and binding cut to length bent to shape required including cranking , bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed. |
| 65 | S&F of MS steel work in tubular trusses including special shaped washers etc., complete using ERW or induction butt welded tubes confirming to IS 1161- 1979 graded St 240, complete all as per specified and as directed. |
| 66 | S&F Pressed steel frames of size 125 mm x 60 mm for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc., including one shop coat of priming complete all ,as specified and directed. |
| 67 | S&F of Pressed steel frames of size 105x60 mm for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc., complete all as per specified and as directed. |
| 68 | S&F powder coated aluminium window sliding type three rake ( 2 glazed & one gauze shutter ) aluminium section weighing not less than 1.67 kg/m for frame and 0.55 kg/m for shutter including necessary joining cleats, glazing clips, rubber neoprene packing, handles, including locking arrangement and 5.5 mm thick plain /tinted glass incl. taking down of old existing steel window and making good disturbed surface of wall complete all as specified and directed. |
| 69 | S&F powder coated aluminium louvered ventilators of size n. exe 0.50 Sqm area with glass louvers, without sash bars of aluminium section weighing not less than 0.605 kg/m for frameof size 40 x 20 x 2 mm including necessary joining cleats, glazing clips, rubber neoprene packing, anodised aluminium fittings 5.5 mm thick plain /tinted glass fixed in panels with suitable arragement incl. taking down of old existing steel ventilator making good disturbed surface of wall complete all as specified and directed. |
| 70 | S&F steel windows with side hung shutters glazzed/gauged shutter incl both side openable (outside glazed window and inside fly proof window) including box type hinges with steel handle, and steel peg stay, complete with glazing bars and incl grill of approved design welded to steel window frame dovetailed or welded complete all as specified and as directed .(Note: Guard bar or square bar shall be maeasure and paid separately.) |
| 71 | S&F of pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet of 0.50mm thick of any colour as approved by GE having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed. |
| 72 | S&F of pre-painted galvalume aluminium zinc coating GI based plain steel sheet of 0.50mm thick of any colour as approved by GE having tensile strength of 550 Mpa as in ridge / wall/cladding, fixed with self tapping screws complete all as specified and directed. |
| 73 | M&L for machine cut kota stone slab flooring 20-25mm thick, for staircase steps (treads) in single piece (of length not more than 1200mm), jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing including provn of two Nos 3x3 mm grooves at tread of each step laid over 15 mm thick screed bed or bedding layers in CM 1:6 complete all as specified and as directed. |
| 74 | M&L for machine cut Kota stone slab 20-25 mm thick in riser of steps, skirting, dado and pillar laid over cement screed and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing, complete all as specified and as directed. |
| 75 | M&L for 20mm thick Granite (of any type) tiles machine cut, in skirting/dado laid over cement screed and jointed with grey cement slurry, and pointed with white cement with admixture of pigment to match the shade of granite stone including grinding and polishing with 10 mm thick screed bed or bedding layer of cement mortar (1:4) complete all as specified and as directed. |
| 76 | M&L for 75 mm thick PCC (1:3:6) type C-2 (using 40 mm graded crushed stone aggregate) as in plinth protection/ footpath/ steps finished cement concrete surface even & fair etc including necessary form work complete all as specified and as directed. |
| 77 | M&L for 100 mm thick PCC type C-2, 1:3:6 (using 40 mm graded aggregate) as in sub base of flooring, plinth protection/ footpath/ hardstanding finishing cement concrete surface even and fair, complete all as specified and as directed. |
| 78 | M&L for 25 mm thick PCC (1:2:4) type B-0 (12.50 mm graded stone aggregate) , as in under layer levelling course for Bath, WC floor below tiles finished even and rough, complete all as specified and as directed. |
| 79 | M&L for 25 mm thick PCC (1:2:4) type B-0 (12.50 mm graded stone aggregate) , as in floor finished even and smooth without using extra cement, complete all as specified and as directed. |
| 80 | M&L for coloured glazed ceramic tiles 350x 250x 7 mm/ 450X 350X 7mm thick, on vertical surfaces such as skirting, dados and risers to steps etc., set and jointed in neat cement slurry and pointed in white or Coloured cement to match over, complete all as specified and as directed. |
| 81 | M&L for non skid ceramic tiles 7 to 8 mm thick (square/rectangular) area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm, vertical surface,in skirting etc set and jointed in neat cement slurry and pointed in white or colour cement match as in floor complete all as specified and directed. |
| 82 | S&F of coloured non-skid ceramic tiles 7 to 8 mm thick (Square/rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors etc, set and jointed in neat cement slurry and pointed in white or coloured cement to match with the shades of tiles over 15 mm thick screed bed or bedding layers in CM 1:6 complete all as per specified and as directed. |
| 83 | M&L for non skid ceramic coloured tiles of design as approved by GE 8 to 10 mm thick (square/rectangular) area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm, in floors etc set and jointed in neat cement slurry and pointed with white cement mixed with pigment to match with shed of tiles over and including 15mm thick screed bed or beading layer of cement mortar (1:6) for laying floor finishes complete all as specified and directed. |
| 84 | Providing holes to cooking platform of size 25 mm dia for inserting cooking gas pipe in suitable place, complete all as specified and as directed. |
| 85 | M & L for providing & fixing of factory made solid PVC cup board frame of size 50mm X 47mm (suitable for two track sliding type shutters) with a wall thickness of 5 mm made out of extruded 5 mm thick prelam/plain colour PVC sheet reinforced with 19 mm x 19 mm MS square tube of 19 gauge thickness throughout the frame and meter cut at two corners and jointed with 2 nos of 150 mm long brackets of 15 mm X 15 mm MS squer tubes. the door frame by using PVC fasteners. A minimum 4 nos screws to be provided for each vertical member and minimum 2 nos of screw to be provided to the horizontal member etc. complete all as specified and directed. incl. existing cup board. |
| 86 | M & L for providing & fixing of factory made solid PVC (two track sliding type) cup board shutter (flush type) 24 mm thick made from co-extruded 3 layer regid PVC foam sheet (single extruded) with density not less than 600 kg /cbm outer layer (8.1mm ) thick should be rigid PVC with density of not less than 1400 kg/cbm manufactured byan ISO 9001-2015 certified company. Door should be water proof, turmite proof, fire retardant and having good screw holding capacity , with all sliding and locking arrangement complete all as specified and as directed, incl. taking down the ext cup board. |
| 87 | S&F of factory made PVC shelf/ partition of required size consisting of 20mm thick Solid PVC Sandwich Panel with 1mm Plain PVC Sheet on both sides suitably, complete all as per specified and as directed. |
| 88 | Providing and laying at or near ground level factory made kerb stone of M-25 Grade cement concrete in position to the required level and curvature, jointed with cement mortar 1:3, including making joints with or without grooves (thickness of joint at sharp curve shall not more than 5 mm), including making drainage opening wherever required, complete all as specified and as directed. |
| 89 | Providing and laying 60mm thick factory made chamfered edge cement concrete paver block of M-35 grade with approved colour, design & pattern as in footparth, parks, lawns, drive ways or light traffic parking etc., of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over and including 50mm thick compacted bed of fine sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand, complete all as per specified and as directed. |
| 90 | Providing and laying of 80mm thick factory made chamfered edge cement concrete paver block of M-40 grade with approved colour, design & pattern as in footpath, parks, lawns, drive ways or light traffic parking etc., of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over and including 50mm thick compacted bed of coarse sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with fine sand and cutting of paver block as per required size and pattern, finishing and sweeping extra sand, complete all as per specified and as directed. |
| 91 | M&L for rendering 10mm thick in cement mortar (1:4) as backing layer in vertical surfaces of skirting dados repir to steps complete all as specified and directed. |
| 92 | M&L for rendering 20 mm thick in two layer, first layer shall be 10 mm thick with cement mortarand second layer finishing coat shall be 10 mm thick in CM (1:4) mixed with WPC @200ml per 50 Kg of cement on brick work or concrete surfaces of wall and finished even and fair complete all as specified and directed. (Note : WPC will be measured and paid separately) |
| 93 | M&L for rendering 15 mm thick in cement mortar (1:6) on other than fair faces of brick work or concrete surfaces of wall, finished even and smooth without using extra cement complete all as specified and directed. |
| 94 | M&L for (10+10) mm thick plaster of cement mortar (1:4) rendering on fair faces of brick work in two layers (10mm & 10mm) mixed with water proofing compound in top layer 200 ml per beg of cement or as per manufacturer's instructions finishing the surface fair and even without using extra cement complete all as specified and as directed.(Note: WPC shall be measured and paid separately as supply only under relevant item.) |
| 95 | M&L for 5mm thick rendering plastering on fair faces of brick work or concrete surface in cement mortar (1:3) and surface even and smooth without using extra cement, complete all as specified and as directed. |
| 96 | M&L for 10mm thick screed bed or bedding layer in cement mortar (1:4) mixed with WPC in order to maintain proper slope over existing roof surfaces for laying water proofing treatment over roof, finished even and smooth without using extra cement, complete all as specified and as directed.(Note: Water proofing compound shall be measured and paid separately under relevant item of this schedule). |
| 97 | M&L for preparing newly plastered surfaces of walls and applying three coats of white wash complete all as specified and as directed. |
| 98 | M&L for preparing newly plastered surfaces of walls and applying one coats of white wash complete all as specified and as directed. |
| 99 | M&L for complete removal of existing treatment of old plastered surfaces of walls and applying two coats of oil bound distemper over a coat of primer after applying 2 coat of cement based wall care putty 1 mm each including complete removal of existing treatment, complete all as specified and as directed. |
| 100 | M&L for prepartion of newly plastered surfaces of walls and applying two coats of oil bound distemper over a coat of primer after applying 2 coats of cement based wall putty 1 mm each to wall surfacel, complete all as specified and as directed. |
| 101 | Material & Labour for complete removal of existing treatment finishing walls with Acrylic Smooth exterior paint of required shade : New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm), complete all as specified and as directed. |
| 102 | M&L for preparing new plastered surface of walls and Finishing walls with Acrylic Smooth exterior paint of required shade : New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) all as specified and as directed. |
| 103 | M&L for preparing old plastered surfaces of ceiling and applying one coat of white wash complete all as specified and as directed. |
| 104 | M&L for preparing newly plastered surfaces of ceiling and applying three coats of white wash complete all as specified and as directed. |
| 105 | S&F of 3 mm thick sheet glass of ordinary quality in squares not exc. 0.5 sqm in each pane glazing with oil putty complete all as per specified and as directed. |
| 106 | M & L for preparation of new wooden Surfaces of any description, not otherwise descri-bed, over 10cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified and as directed. |
| 107 | M&L for applying two coats of synthetic enamel paint (1st grade quality) over a coat of red oxide primer after preparation of new steel surfaces of any description not exceeding 10cm width or girth complete all as specified and directed. |
| 108 | M&L for preparation of new steel or iron surface of any description and applying two coats of synthetic enamel paint over a coat of red oxide primer on steel surface n.exc 10 cm width or girth complete all as specified and as directed. |
| 109 | S&F in repairs of 15mm dia long body bib tap, fancy type, cast copper alloy with crutch or butterfly handles, screwed down, screwed for iron pipe or for brass ferule, chromium plated with long screw type fixed complete all as specified and directed. |
| 110 | S&F in repair of fancy type 15mm dia bore pillar tap cast copper alloy with capstan heads chromium plated, screwed down high pressure with or without lettered Hot or Cold with long screwed shanks and fly-nuts, screwed for iron pipe complete all as specified and as directed. |
| 111 | S&F of PVC valveless, syphonic action type 10 ltr capacity low level flushing cistern, white, with inlet, ball valve, float and handle including brackets and 32 mm bore PVC flush pipe, complete all as per specified and as directed. |
| 112 | S&F in repairs of vitreous china wash basin, white, flat back, size 550 X 400 mm, excluding taps, chain and plug and porcelain stopper but including waste pipe, brackets and cutting for and pinning in ends of brackets or erecting stand acomplete all as specified and directed. |
| 113 | S&F in repair of toilet paper holder with flat recessed type stainless steel including all necessary fittings, complete all as per specified and as directed. |
| 114 | S&F in repair of 20 mm ball valves, high pressure of PTMT with epoxy coated Aluminium rod & high density plastic ball screwed for iron pipe and fixed (Minimum weight 15mm-142gms/ 20 mm - 210gms/25mm-455gms/ 40mm - 690 gms) and fixed in position complete all as per specified and as directed. |
| 115 | S&F in repair PTMT towel ring complete all as specified and directed. |
| 116 | S & F in repair swivel shower of CP with shower arm 150 mm size for fixing with 15 mm bore GI pipe complete all as specified and as directed. |
| 117 | S&F in repairs of brass chromium plated tubular towel rail, 20mm dia, D-type, 60cm long between flanges complete all as specified and directed. |
| 118 | S&F in repairs of stainless steel kitchen plate rack made of 0.65 mm thick stainless steel sheet of size 786 mm X 914 mm X 254 mm X fixed to wall with screws, complete all as specified as directed. |
| 119 | M&L for 75 mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints laid in trenches or in floors complete all as specified and directed. |
| 120 | S&F of 110 mm dia PVC (SWR) pipes single socketed, in any length with rubber ring joints fixed to walls, complete all as per specified and as directed. |
| 121 | S&F in repairs of 15 mm dia PVC connection pipe of length 600 mm with PTMT nuts complete all as specified and directed. |
| 122 | S&F in repair of two way bib tap,cast copper alloy with operating knob and wall flange, fancy type, chromium plated screwed down high pressure, screwed both ends for 15 mm bore iron pipe or brass ferrule, complete all as specified and directed. |
| 123 | S&F in repairs long body bib tap with wall flange, 15 mm dia cast copper alloy, chromoium plated, fancy type with crutch or butterfly handles screwed down for iron pipe or forr brass ferrule, complete all as specified and directed. |
| 124 | S & F in repair 15 mm bore angle cock CP with flage complete all as specified |
| 125 | M&L for cast iron nahani trap of 100 mm dia, with grating including jointing to waste pipe fixed in cement concrete type B-1 (1:2:4), complete all as per specified and as directed. |
| 126 | M&L for salt-glazed stoneware gully traps, square or round mouthed, type `P' 150x100mm complete all as directed by Engr-in-Charge |
| 127 | S&F in repair of health faucet (ABS) mild steel chromium plated (suitable for 15 mm outer dia CPVC pipe) with 1.25 mtr long flexible tube and ABS wall hook including making connection and fixed complete all as specified and directed. |
| 128 | S&F in repairs of Vitreous China wash down water closet pan (pedestal pattern), white, including connection to drain (or outgoing pipe) and to flushing pipe, antisyphonage pipe, etc. and plastic water closet seat cover, black, closed pattern with flat bottom, and cover and mild steel chromium plated or aluminised hinging device, complete all as per specified and as directed. |
| 129 | S&F of PVC (SWR) 110 mm bore bends with access door complete all as per specified and as directed. |
| 130 | S&F of 110mm dia PVC (SWR) branch piece single (single 'Y') equal or unequal with access door complete all as per specified and as directed. |
| 131 | S&F of 110mm dia PVC SWR vent cowl complete all as per specified and as directed. |
| 132 | S & F in repair sink without drainage board made of stainless steel 1 mm thick kitchen or laboratory with plugs, washers; including bedding in cement mortar to dwarf wall or including fixing cantilever brackets and connecting union to pipe over all size 495mm x 420mm bowl size 410mm x 330mm x 160mm, complete all as per specified and as directed. |
| 133 | S&F in repair of vitreous china squatting pan \\"Orissa\\" pattern size 580x440mm white with integral foot rests(excluding flushing cistern and flush pipe) with 'P' or 'S\\" trap from or back inlet etc including connection to trap and flushing pipe and provision of lime concrete bedding, complete all as per specified and as directed. |
| 134 | S&F in repair of 600mm x 450 mm bevelled edge mirror of selected quality glass, mounted on 6mm thick AC building board on commercial plywood and fixed to wooden plugs with chromium plated brass screws and cup washers complete all as specified and directed. |
| 135 | S&F in repairs of Sheet glass shelf assembly consisting of 5.5mm thick sheet glass shelf 12cm wide with chromium plated bracket guard and railing 60cm long complete all as specified and directed. |
| 136 | S&F in repairs of CP soap dish fixed to wall with brass chromium plated screws, complete all as per specified and as directed. |
| 137 | M&L for GI pipe 40mm dia (light grade) complete with all fittings in trenches, road/culvert crossing, floors, on roof, on pole for cable protection including taking down old unsv pipe complete all as specified and directed. |
| 138 | S&F GI tubes medium grade with all fittings fixed to walls and celing or laid in floors or 15 mm bore pipe complete all as specified and directed. |
| 139 | S&F of GI tube 20 mm bore medium grade with all fitting and fixed complete to walls and ceilings or laid in floors complete all as specified and as directed. |
| 140 | Refixing of old 15 mm GI tubing and connections in new or old position (Walls, ceiling, floors, etc.) complete all as specified and as directed. |
| 141 | S&F of rotational moulded polyethylene water storage tanks double layered ISI Marked (cylindrical, vertical with closed top) of 500 Litres capacity hoisted and fixed in position including connecting up pipes securing access covers etc, complete all as per specified and as directed. |
| 142 | Supply and fixing in repair of 20mm dia gun metal gate valves with iron wheel head, screwed both ends for iron pipes including taking down old unserviceable gate valve complete all as specified and as directed. |
| 143 | SCHEDULE 'A' PART -II (ELECTRICAL WORK)Taking down carefully copper/aluminium point wiring (light, fan, bell, socket or power) complete, including fixtures and fittings such as switches, ceiling roses, holders, regulators, sockets, light fittings and including making good the disturbed surfaces to match with the existing surfaces by applying white/ colour wash/distemper over applying of putty for smooth finish surface complete all as specified and directed. |
| 144 | M&L for point wiring complete with 1.5 Sqmm multistranded copper conductor single core PVC insulated unsheathed FR-LS cable 1100 volts grade (ISI marked) with proper colour coding drawn through and including non-metallic rigid PVC medium grade conduit not less that 20mm dia and conduit accessories (ISI marked) concealed in wall/fixed to roof, ceiling etc including provision of 1.5 Sqmm PVC insulated multistranded unsheathed copper conductor cable FR-LS (ISI marked) as earth continuity conductor connected to common earth dolly, including modular metal flush box of appropriate sixe with modular frame and cover plate concealed in walls, earthed including cutting chases of existing wall and making good to the disturbed surface of wall/floor and matching with existing specifications. Connections of cable with MCBs or bus bar shall be done through proper size copper/brass thimbles, complete all as specified and as directed for one light point controlled by one way switch 5/6 amps . |
| 145 | All as per Item No.144.00 above but One celling fan/exhaust fan point controlled by one switch 5/6 amps complete all as specified and directed. |
| 146 | All as per serial item No. 144.00 above but for one light point controlled by two way switch. |
| 147 | All as per Item No.144.00 above but One socket out let one 5/6 amps on same board complete all as specified and directed. |
| 148 | All as per Item No.144.00 above but One socket out let one 5/6 amps on independent board complete all as specified and directed. |
| 149 | All as per serial item No. 144.00 above but with 2.5 sqmm single core multistranded copper conductor for one socket out let 15/16 amps point on the independent board, complete all as specified and as directed. |
| 150 | All as per serial item No. 144.00 above but for one Bell point controlled by one switch. |
| 151 | S&F of Modular switch, single pole, one way, 6 Amp, 1 Module, 230 volt, ISI marked, complete all as specified and as directed. |
| 152 | S&F of Modular Switch single pole, one way, 16 Amps, 1 module, 230 volts, ISI marked, complete all as specified and as directed. |
| 153 | S&F of Modular switch, single pole, Two way, 6 Amp, 1 Module, 230 volt, ISI marked, complete all as specified and as directed. |
| 154 | S&F of Modular Bell push 6 Amp, 1 Module, 230 volt, ISI marked, complete all as specified and as directed. |
| 155 | S&F of Buzzer, Ding Dong AC 230 volts, single pole, complete all as specified and as directed. |
| 156 | S&F Socket, 6A - 2/3 pin combined 2 module,white ivory finish modular type complete all as specified and directed. |
| 157 | S&F Socket, Socket 6A/16A - 2/3 pin combined 2 module,white ivory finish modular type complete all as specified and directed. |
| 158 | S&F of modular switch 16 Amps, single pole, 1 way, 1 module, 240V, AC, complete all as specified and directed. |
| 159 | S&F of modular fan regulator, electronic, 360 degree rotation (0 to 4), 100 to 120 Watts, 2 module, 240Volts, AC, complete all as specified and directed. |
| 160 | S&F of ceiling rose , three terminal, PVC/polycarbonate body, ISI marked complete all as specified and directed. |
| 161 | Supply and fixing in repair of 20W inverter LED batten with square profile and polycarbonate channel, including lithium-ion battery with a charging time of 8–10 hours and a backup time of up to 4 hours, complete with driver andsurge suppressor of 3.5 kv or more, luminaire efficiency not less than 100 lumens/watt, power factor not less than 0.90,CRI 80 THD 10%, operating range -140 to 270 V, 50 Hz connecting up with two or three-core flexible copper conductor cable from the ceiling rose to the tube light fitting, complete in all respects as specified and as directed. |
| 162 | S&F of socket 2 in 1, 5 pin, 5/6 Amps, white ivory finish flush type complete all as specified and directed. |
| 163 | S&F of switch piano flush type single pole, one way, 5/6 amp, complete all as specified and directed. |
| 164 | Supply and fixing of LED lights fitting 1x 20 W, 220V, AC decorative box type with driver, IP 20,class I, wall/surface mounted, integrated type with extruded aluminium housing integrated high efficiency electronic driver and surge suppressor of 4 KV or more, luminaire efficiency not less than 120 lumens/watt, power factor not less than 0.90,CRI 80, THD 10%, operating range-140 to 270 V, 50Hz fixed connecting holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose with all accessories internally prewired and including necessary taking down the old and unserviceable fitting complete all as specified and as directed. |
| 165 | S&f of IP 20,Class I, LED mirror light fitting 1X10 W, (or nearest next higher wattage) 5700 K,wall/surface mounted with aluminium housing 2 feet long,integrated type, with high efficiency PMMA diffuser, integrated high efficiency electronic driver & surge supressor of 20 KV or more, luminaire efficiency >95 lumens/watt, power factor>/ 0.90, operating range -140 to 270 V, 50 Hz fixed with 02 Nos of PVC round/square blocks,screws etc complete including 01 no 10W LED lamp with all accessories internally prewired and including necessary taking down the old and unserviceable fitting complete all as specified and as directed. |
| 166 | Supply and fixing of LED lights fitting 1x 10 W, 220V, AC decorative box type with driver, IP 20,class I, wall/surface mounted, integrated type with extruded aluminium housing integrated high efficiency electronic driver and surge suppressor of 4 KV or more, luminaire efficiency not less than 100 lumens/watt, power factor not less than 0.90,CRI 80, THD 10%, operating range-140 to 270 V, 50Hz fixed connecting holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose with all accessories internally prewired and including necessary taking down the old and unserviceable fitting complete all as specified and as directed. |
| 167 | Supply, laying and testing cable XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 6 sq. mm 2 core all fixing and connecting accessories such as cable lugs, cable glands, nut, bolts, complete all as specified and directed . |
| 168 | Material and labour for concealed sub-main wiring alongwith earth wire of size of 2 x 4.0 sq. mm + 1 x 4.0 sq. mm earth wire, ISI marked, FRLS, PVC insulated, multi stranded, copper conductor, single core cable drawn through and including PVC rigid conduit (medium grade) of of size not less than 25 mm with all fittings and accessories ISI marked including cutting chases for conduits & making good to walls, floors etc complete, including taking down old unsv aluminium submain wiring all as specified and as directed. NOTE : Two runs of 4 sqmm conductor for main and one run of 4 sqmm conductor as earth wire with proper colour coding including one run run of PVC conduit shall be measured as one unit length. Connections of cables wit MCBs or bus bar shall be done through appropriate size brass/ copper thimbles |
| 169 | Supply and fixing of sheet metal enclosure powder painted for MCB SPN 2 way single door DB, 240 Volts, 200 Amp with din rail and bus bar including making good to the disturbed surface matching with the existing surface complete all as specified and as directed. |
| 170 | S&F MCB DB conforming IP 43 -IK 09 with acrylic door 4 way double door complete with all connection -phase, nutral and Earthig bar and making good the disturbed surfaces complete all as specified and directed. |
| 171 | Supply and fixing of sheet metal enclosure powder painted for MCB SPN 8 way double door DB, 240 Volts, 200 Amp with din rail and bus bar including making good to the disturbed surface matching including taking down old unserviceable one complete all as specified and as directed. |
| 172 | Supply and fixing of 240V, 10 KA 'B' curve miniature circuit breaker (MCB) of single poles and current carrying capacity 6 to 32 AMP, in the MCB DB Complete with connection testing and commissioning including taking down of old unserviceable complete all as specified and as directed. |
| 173 | S&F of in replacemen MCB, SP, 6 Amps to 32 Amps , 'C' series, 240 Volt, 10KA, 50 Hz, complete all as specified and directed |
| 174 | S&F of in replacement MCB, SPN, 6 Amps to 32 Amps , 'C' series, 240 Volt, 10KA, 50 Hz, complete all as specified and directed |
| 175 | Taking down carefully Ceiling fan from its original position and refixing / hanging after plaster work including painting of ceiling fan complete, in situ with synthetic enamel paint by spraying including filling cavities with filler one coat after cleaning all dust etc, complete all as specified and as directed. |
| 176 | Supply and laying of XLPE insulated, LT armoured electric cable with aluminium stranded conductor 1100 volts grade, cross-sectional area 10 sqmm, 2 core laid in trenches/pipes/ducts/wall/borings with necessary cable lugs and glands, nuts, bolts and washers etc and testing including taking down old unsv cable complete all as specified and directed.(NOTE: Excavation/earth work, sand cushioning, cable cover/brick shall be measured and paid separately if required) |
| 177 | M&L for brick covering with width equal to length of brick as protection to cable with well burnt sub class ‘B’ bricks of size 230mm x 125mm x .75mm laid dry flat complete all as specified and directed. |
| 178 | M&L for sand cushioning to under ground cable in trenches/existing cable trenches/ducts in layers of 8 cm deep before laying the cable and 15 cm deep including required watering and consolidation after laying and stretching the cable complete all as specified and directed. (Note: Only punned down volume of sand to be measured) Please Enable Macros to View BoQ information |
| 179 | M&L for sand cushioning to under ground cable in trenches/existing cable trenches/ducts in layers of 8 cm deep before laying the cable and 15 cm deep including required watering and consolidation after laying and stretching the cable complete all as specified and directed. (Note: Only punned down volume of sand to be measured) Please Enable Macros to View BoQ information |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail