Sales : +91-777 804 8217
| Sl. No. | Item Description |
| 1 | Taking down cement plaster of any description in any position including racking out joints making key scrubbing down with water etc. and removal of debris out side MD land. Complete all as specified and directed. |
| 2 | M&L for 10 mm thick rendering in CM 1:3 on fair faces of concrete surfaces of ceiling on plastered ceiling surfaces; surfaces finished even and smooth with out using extra cement. Complete all as specified and directed. |
| 3 | M&L for 15mm thick plastering in CM 1:6, on fair faces of brick work or concrete surfaces and provn of 3mm thick wall care putty on plastered surfaces of wall; surfaces finished even and smooth with out using extra cement Complete all as specified and directed. |
| 4 | M & L for 15mm (10+5) thick rendering in Cm 1:4 using WPC @ 2% by weight of cement on brick work or concrete surfaces; surfaces finished even and smooth with out using extra cement. Complete all as specified and directed. Note: Water proofing compound shall be measured & paid separately. |
| 5 | Demolition of brick work built in CM incl. taking out roots vegetation if any at any position and removal to out side MD land. Complete all as specified and directed. |
| 6 | M&L for brick work with sub class 'B' bricks straight or curved on plan exc. 6m mean radius built in CM(1:6) Complete all as specified and directed. |
| 7 | M&L PCC 1:3:6 type C2 75mm thick as in plinth protection finished even and smooth using extra cement Complete all as specified and directed. |
| 8 | Taking down chowkats without taking off shutters from the frame area not exc 1.50 Sqm each Complete all as specified and directed. |
| 9 | Taking down chowkats without taking off shutters from the frame exc.1.50 Sqm and not exc. 4.00 Sqm. Complete all as specified and directed. |
| 10 | Taking down shutters of any description exc 1.00 sqm n exc 2.00 sqm. Complete all as specified and directed. |
| 11 | S&F 2nd class hard wood plain solid straight chowkats and framed rebated on the solid rounded put togeather with glue pinned at joints all as specified. Complete all as specified and directed. |
| 12 | S&F 2nd class hard wood 35mm thick factory made plain framed, panelled shutters (two panels) with lock rail and panel of 9mm BWP commercial or 12mm veneered particle board with commercial veneer on both faces the size of rail and stile as per IS 1003 (Part-I) kiln seasoned and chemically pressured treated. Complete all as specified and directed. |
| 13 | S&F of Aluminium alloy wire cloth, 0.45mm nominal dia of wire and average width of aperture 1.40mm and fixed with aluminium wire staples or wooden/ Aluminium beadding Complete all as specified and directed. |
| 14 | S&F 2nd class HW 35mm thick glazed and skeleton shutters, open rebated and pepared to receive glass, gauze, etc with sash bar, edges of framing plain, chamfered or rounded, fitted with cut or mitred beads for securing glass, gauze etc sizes of members of shutters as specified in SSR part-1 section 8, clause 8.24 (a); all as specified. ISI marked. Complete all as specified and directed. |
| 15 | M&L for painting with synthetic enamel paint of two coats over a coat of primer on new wooden surfaces of any description exc. 10 Cm width or girth including prepation of surfaces. Complete all as specified and directed. |
| 16 | M&L for applying one coats of synthetic enamel paint on old wooden surfacesof any desccription exc. 10cm width or girth including preparation of surfaces. Complete all as specified and directed. |
| 17 | M&L for MS hold fasts size 25x6mm FI fixed to chowkats. Complete all as specified and directed. |
| 18 | Providing PCC 1:2:4 type B1 (using 20mm graded stone aggregate) cement concrete in bed blocks for hold fasts. Complete all as specified and directed. |
| 19 | S&F of stainless steel butt hinges heavy weight 100mm long. Complete all as specified and directed. |
| 20 | S&F of aluminium anodised barrel tower bolts of extruded section 150mm long. Complete all as specified and directed. |
| 21 | S&F of aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet cast or extruded sections and fixing bolts and sliding bolts of extruded section or cast alluminium alloy and fixed of length of bolt 300 mm. Complete all as specified and directed. |
| 22 | S&F of extruded aluminium alloy handles, fabricated type, anodised 150mm size. Complete all as specified and directed. |
| 23 | Dismantling stone slabs or pcc tiles of any description or thickness in steps, landing, flooring and similar work laid, bedded and pointed in cement mortar complete. Complete all as specified and directed. |
| 24 | M&L for 20 to 25 mm machine cut kota stone slab in single piece with round nosing with three numbers of serration as in treads of steps for staircase laid over cement screed bed and jointed with grey cement slurry mixed with pigment to match the shade of of the slab including rubbing and mirror polishing and including over 15mm thick screed bed or bedding layer in CM1:4 Complete all as specified and directed. |
| 25 | M&L for 20 to 25mm machine cut kota stone slab as in riser of steps, skirting, dado and pillar, cills and jambs laid over cement mortar backing coat jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing with beewax polishand including over 15mm thick screed bed or bedding layer in CM1:4. Complete all as specified and directed. |
| 26 | S&F for anodized aluminium section in frame or shutters of window , doors and partition with aluminium section (medium weight) of suitable size as directed by Engineer-in-Charge, cut to size, jointed together with cadmium plasted steel screws and all necessary fitting, screw, plug for fixing screws locking arrangement etc. Complete all as specified and directed.Note:- The rate of glass pane, wire mesh will be measured and paid separately. |
| 27 | S&F 4.8mm thick glass selected quality in each pane for aluminimum door shutters, aluminium partition wall and sliding windows/ventilator shutters etc including rubber beading or gasket for aluminium section Complete all as specified and directed. |
| 28 | S&F of anodised aluminium grill DG- 102 (10 mm x 5.2mm) of Deco grill or equivalent fixed with 'F' section size not less than 20.60 x 15.20 x 1mm thick of approved make. Complete all as specified and directed. |
| 29 | S&F solid PVC door frame(choukhat) of size 50mm x 47mm made out of 5mm plain dark colour PVC sheet reinforced with MS square tube etc Complete all as specified and directed. |
| 30 | S&F factory made solid panel PVC door shutter 30mm thick (style) consisting of frame made out of MS tubes for top& bottom rails. MS frame shall be covered with heat moulded plain dark colour PVC 'C 'Channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain dark colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail& bottom rail; panelling of plain colour PVC sheet to be fitted in the MS frame welded/sealed to the stiles & rail with suitable PVC sheet beading and joined together with solvent cement, etc fixed to frame. Complete all as specified and directed. |
| 31 | S&F floor door stopper of aluminium alloy body and tongue, anodised with hard drawn steel spring, fixed in floor of 140mm size. Complete all as specified and directed. |
| 32 | S&F in repair PVC flushing cistern 10 ltrs capacity high/low level with inlet, ball valve, float and handle including brackets. |
| 33 | M&L for providing stages wise waterproofing treatment to sunken portion of toilets as under. |
| 34 | Stage 1: Demolition of WC including lime concrete and cement concrete coba etc and preparing the surfaces of existing sunken portion of WCs or bath etc with wire brush to remove all loose dirt, oil grease etc including removing debries outside MD land etc complete all as specified and directed. |
| 35 | Stage 2: Providing 15 mm thick plaster in CM 1:3 mixed with integral water proofing chemical of STP Ltd in the proportion /quantity all as per manufactures instructions.Note :- Rate inclusive of waterproofing compound. |
| 36 | Stage 3: Primer - Mix Tarfelt LM with water in ratio 1:1 @ 250 gms/sqm and apply the primer on the plaster surfaces |
| 37 | Stage 4: Application of 1 st coat of Tarfelt LM of STP Ltd without dilution with water@1kg/sqm by brush all as per manufactures instructions. |
| 38 | Stage 5: Laying 50 GSM fiber glass cloth over the 1st coat while the coated surface is still tacky |
| 39 | Stage 6: After 6 to 7 hours interval apply second coat i.e final coat of Tarfelt LM without dilution with water of STP Ltd by brush as per manufactures instructions @1kg /Sqm |
| 40 | Stage 7: Providing 10mm thick protective plaster in CM 1:3 mixed with STP NO -1 @ 250ml/50kg cement all as manufactures instructions.Note:- Rate inclusive of waterproofing compound. |
| 41 | M&L for cement concrete Type E2 1:5:10 using 40 mm graded aggregate as in lean concrete. |
| 42 | S&F in repairs vitreous china wash down water closet pan (padestal pattern), white complete including seat cover and connection to trap and to flushing pipe, anti syphonic pipe etc., Complete all as specified and directed. |
| 43 | M&L for PVC valveless, syphonic action type, 10 ltrs cap flushing cistern, low level, white, with inlet, ball valve, float and handle including brackets and flush pipe 32mm dia and fixed in repairs Complete all as specified and directed. |
| 44 | M&L for WC connector 110 mm PVC SWR for WC Complete all as specified and directed. |
| 45 | Supply only PVC connector 15mm size with PTMT nuts of length 450mm |
| 46 | S&F of Stainless steel floor trap, plain with grating removeable & refixable type including jointing with solvent cement 100 mm dia of outlet Complete all as specified and directed. |
| 47 | M&L for Mirror 600mm x 450mm bevelled edge mirror of selected quality glass, mounted on 6mm thick AC building board or commercial plywood and fixed to wooden plughs with chromium plated brass screws and cup washers in repairs Complete all as specified and directed. |
| 48 | S&F in repairs stainless steel sink with drainage board made of stainless steel 1mm thick kitchen or labouratory with plugs, washers, and wastes. including bedding in cement mortar to dwarf wall or including fixing cantilever brackets and connecting union to pipe overall size 915mm X 460mm and bowl size 410mm x 330mm x 160mm including necessary fittings such 40mm coupling waste, pipe. Complete all as specified and directed. |
| 49 | S&F of Wash basin, Vitreous China white (Flat back) 630 x 450mm including brackets,, pinning in ends of brackets or erecting stand including fixing of waste pipe and pillar type etc. Complete all as specified and directed.Note: Suppy of pillar tap and waste pipe shall be measured separately. |
| 50 | Supply and Fix of pillar tap 15 mm diacast copper alloy chromium plated fancy type. Complete all as specified and directed. |
| 51 | S&F of waste fitting of 32 mm bore, brass, chromium plated for glazed ware wash basin etc. Complete all as specified and directed. |
| 52 | S&F of stop valves 15mm bore dia, cast copper alloy fancy type, chromium plated with long shank and cup concealed type, screwed down high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions in repairs. Complete all as specified and directed. |
| 53 | Supply only Low density polyethlene (LDPE) pipe of pressure rating 6 Kgf / Sqcm 40 mm dia. Complete all as specified and directed. |
| 54 | S&F of bib tap brass 15mm bore dia chromium plated long shank fancy type with curtch or butterfly handle , screwed down, screwed for iron pipes complete in repairs Complete all as specified and directed. |
| 55 | S&F in repairs brass chromium plated towel rail 20mm dia, \\"D\\" type. Complete all as specified and directed. |
| 56 | S&F stainless steel soap dishes approximate size 160mm x 160mm x90mm. Complete all as specified and directed. |
| 57 | M&L Glass Assembly sheet glass consisting of 5.5mm thick sheet glass 12cm wide with chromium plated bracked guard and railing 60cm long in repairs. Complete all as specified and directed. |
| 58 | M&L Brass chromium plated shower rose 125mm size including fixing to steel pipe or union in repairs. Complete all as specified and directed. |
| 59 | Taking up or down steel tubing 15mm bore of pipe and connections including cleaning for refixing etc as required Complete all as specified and directed. |
| 60 | All as per item No 52 above but 25mm bore of pipe Complete all as specified and directed. |
| 61 | M&L for tubes medium grade galvanised, with all fittings and fixed complete to walls or ceiling or laid in floors 15mm bore dia. Complete all as specified and directed. |
| 62 | All as per item No 54 above but 25mm bore dia Complete all as specified and directed. |
| 63 | S&F of gun metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed bore of 25 mm in repairs Complete all as specified and directed. |
| 64 | M&L for Rotational moulded polyethylene water storage tanks (Cylindrical verticval with closed top) hoisted & fixed in position in repairs all as specified of 2000 ltrs capacity Complete all as specified and directed. |
| 65 | M&L in repairs Ball valve high pressure of PTMT with epoxy coated Aluminium rod & highdensity plastic ball screwed for iron pipe and fixed complete 25mm dia Complete all as specified and directed. |
| 66 | M&L for Nipple suitable for HDPE water tank (minimum weight 25mm - 65 gms) 25mm bore dia Complete all as specified and directed. |
| 67 | S&F in repairs 40 mm Gun-metal, globe or gate valves,with iron wheel head, screwed both ends for iron pipe and fixed. Complete all as specified and directed. |
| 68 | S&F in repairs 25 mm Gun-metal, globe or gate valves,with iron wheel head, screwed both ends for iron pipe and fixed. Complete all as specified and directed. |
| 69 | Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles and rubbish off the premises etc Complete all as specified and directed. |
| 70 | Material and Labour for non skid coloured ceramic tiles 7 to 8mm thick (square / rectangular) area of each tile exceeding 0.06 sqm but not excceeding 0.11 sqm in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match and including screed bed or bedding layer of mortar 15mm thick for laying floor finishes in CM 1:6. Complete all as specified and directed. |
| 71 | M&L for glazed ceramic jointless coloured tiles in vertical surface 350 x 250 x 7mm / 450 x 350 x 7mm set and jointed in neat cement slurry over and including provision of bedding layer 10mm thick in CM 1 : 3. Complete all as specified and directed. |
| 72 | M&L for Non-skid coloured joint free Ceramic tiles of size 600mm x 600mm x 10 mm thick in floors over and including 20 mm thick screed bed in cement mortar 1:4 etc. set and jointed in neat cement slurry and grouted with epoxy grout to match. Complete all as specified and directed.Note : Cost of 20 mm thick screed bed is included in the rate. |
| 73 | All as per item No 65, but in vertical surfaces as in skirting etc complete over and including 10 mm cement plaster in cement mortar 1:4 Complete all as specified and directed. Note: The rate includes the cost of cement plaster. |
| 74 | Taking down 100 mm cast iron soil waste pipe moulding all fittings heads, shoes, bends etc. Complete all as specified and directed.Note: To be measured over all as fixed along the centre line over fittings and accessories. |
| 75 | S&F of 100mm dia CI spun cast iron pipe jointed with cement joint and fixed to walls including cutting of holes wherever required. Complete all as specified and directed. |
| 76 | S&F of 100mm dia CI bends including cutting of holes Complete all as specified and directed. |
| 77 | S&F of 100mm dia CI branch pieces, double (equal or unequal) ordinary or inverted (spigot or socket type) or with parallel branches and cutting of holes with cement joints. Complete all as specified and directed. |
| 78 | S&F of CI cowl 100mm dia Complete all as specified and directed. |
| 79 | S&F of 20mm dia aluminium alloy curtain rail fixing with pair of brackets, stops, rollers etc Complete all as specified and directed. |
| 80 | M&L for preparation of new plastered surfaces of walls and applying two coats of oil bound distemper with roller over one coat of alkali resistant primer finish etc Complete all as specified and directed. |
| 81 | M&L for complete removal of existing surfaces including washing / rubbing down with water of wall and applying two coats of oil bound distemper over a coat of primer finish etc Complete all as specified and directed. |
| 82 | M & L for preparation of new plastered surfaces on ceilings and applying two coats of oil bound distemper with roller over Complete all as specified and directed. |
| 83 | M&L for complete removal of existing surfaces on ceiling and applying two coats of oil bound distemper with roller over application of putty Complete all as specified and directed. |
| 84 | M&L for for preparation of old plastered surfaces of walls, chajjas, slab projections and applying one coats of 100% Anti fungal acrylic emulsion paint in approved shade including necessary scaffolding Complete all as specified and directed. |
| 85 | M&L for preparation of NEW plastered walls surfaces for applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/Litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces. |
| 86 | Taking down AC rain water pipe any size or pattern incl all fittings heads, shoes, bends. Swan necks, etc including cleaning for refixing or removing to store. Complete all as specified and directed. |
| 87 | M&L for 110mm dia PVC rain water pipe single socketed (ISI marked) fixed fixed to wall with mild steel clamps including complete fittings such as heads, bends, shoes, swan necks etc. Complete all as specified and directed. |
| 88 | Dismantling of boarding, any description and in any position. Complete all as specified and directed. |
| 89 | M&L for 18/19mm thick prelaminated particle board with teak wood beading, interior grade, prelaminated one side with decorative choice lamination & other side balancing white lamination, fixed with screws to timber frame work Complete all as specified and directed. |
| 90 | M&L for 2nd class hardwood moulding n. exc 6 sqcm as in cornices, picture rails and the like such as in prelaminated particle board. Complete all as specified and directed. |
| 91 | S&F 30mm width of flange continous (piano) hinges, mild steel, bright finish or electro-galvanised. Complete all as specified and directed. |
| 92 | M&L for post construction anti-termite traetment along the external wall below concreate or masonary apron using chemical emulsion @2.25 liters per linear meter including drilling and plugging holes with cement morter 1:2 to match the existng floor etc. Complete all as specified and directed. |
| 93 | M&L for post construction anti-termite treatment at points of contract of wood work using chemical emulision (in oil or kerosin based solution) @ 0.5 liters per hole by drilling 6 mm dia holes at a down ward angles of 45 degree at 150 mm centere to center and sealing the same with white cement and making good to the existing surfaces etc. Complete all as specified and directed. |
| 94 | M&L for Treatment of soil under existing floors using emulsion @ one litre per hole, 300mm apart including drilling and plugging 12mm dia holes with cement mortar 1:2 (1 cement: 2 coarse sand) to match the existing floors. Complete all as specified and directed. |
| 95 | M & L for providing and injecting chemical emulsion for Post Constructional Antitermite Treatment along external wall where the apron is not provided using chemical emulsion at the rate of 7.5 litres per sq.m of the vertical surface of the sub-structure to a depth of 300mm including excavating channel along the wall and rodding etc. Complete all as specified and directed. |
| 96 | M&L for Two coat of synthetic enamel paint over a coat of aluminium red oxide primer to old steel surface including preparation. Complete all as specified and directed. |
| 97 | RELIEVING STRUCTURAL MEMBERSRelieving Structural members such as column, beam and slabs of their superimposed loads partially or fully by provision of adjustable steel props, frames etc. including providing necessary timber runners, bracing, jacking up arrangement all Complete to the satisfaction of Engineer in charge. Note: Removing and redoing of brickwork, if required, shall be paid separately. |
| 98 | Chipping off existing loose, damaged Concrete from RCC members of all affected RCC Columns, Beams, Slabs and Chajias on External facades and internal areas. ets beyond main r/f. (if required in the opinion of the Consultant), carefully with chisel and hammer Providing and appiving 'Rusticide SS' Rust passivator or equivalent as specified in the Brand Names to existing r/f. bars Including wire brushing of reinforcement, cleaning washing of concrete etc complete as directed. Providing and applving two coats of rust preventor slurry made out of \\"Polyalk Fixoprime\\" or equivalent as specified in the Brand Names and cement in proportion 1:1.5 to existing r/f.bars as directed complete. Providing and applying bonding coat of slurry made out of \\"Polvalk EP\\" or equivalent as specified in the Brand Names and cement in proportion 1:1 to concrete and r/f substrates complete as directed. Providing and applying \\"Polyalk EP\\" or equivalent as specified in the Brand Names and providing Ready mix Polymer modified cement mortar of minimum M40 grade) to RCC members Including Hand packing, curing and making the surface rough for plastering. |
| 99 | FILLING AND REINSTATING OF SEPARATION CRACKSOpening the Separation Cracks at the Junction of RCC and Masonry where ever directed and instructed into \\"V\\" Grooves 2\\" to 3\\" from the either side of the cracks by carefully marking the areas to be opened up using a Cutting machine and skillfully /carefully Chiseling with a well sharpened chisel and hammer as directed including Wire brushing and washing of concrete Substrata and masonry walls with water jet to the surfaces thus prepared to the entire satisfaction of the Consultant as instructed and directed. |
| 100 | Moistening the Cracks, Providing and applying priming/bonding coat of slurry made out of \\"Polyalk EP\\"and cement (or equivalent as specified in the List of Brand names) in proportion 1:1 to surfaces prepared as instructed and directed. Filling the Cracks /Grooves by Providing and applying \\"Polyalk EP\\" Polymer modified cement mortar (or equivalent as specified in the List of Brand names) in Proportion of 1: 5: 15 (Polyalk EP: Cement: Graded sand/quartz sand) on the prepared surfaces and finishing it in level with the existing plaster Including Hand packing, curing and making the surface similar to the external plastering using wooden floats/punch etc. Complete all as specified and directed. |
| 101 | Drilling Holes of required size upto 16 mm Diameter and upto 50mm depth in concrete and cleaning the same as directed. |
| 102 | Providing and fixing 12 mm diameter aluminum /PVC injection nipples and securing the same as directed & Providing and injecting cementitious grout using CEBEX-112 additive of 'Fosroc' at the rate of 225 grams per bag of cement and using suitable mechanical gun/pump including mixing ete complete. |
| 103 | Providing & fixing epoxy dipped shear keys of 10mm dia and 4M to 6% length in. columns.before jacketing.Micro concreting.as.per Consultants Instructions and directions. |
| 104 | Providing, cutting bending and fixing Additional Reinforcement in position steel reinforcement of specified/required sizes and shapes in the form or main rebars, stirrups & rings, distribution rebars etc., and tying them to shear connectors using GI binding wire. The additional rebars should be coated with TWO coats of Anti Corrosive protective coating & dry sand to be sprinkled on second coat including tying with Annealed Binding wires, providing cover blocks of appropriate sizes etc. Complete as specified and instructed by the Consultants. |
| 105 | Providing and laying Super fluid Microconcrete of minimum (M- 40 grade) -Roffe crete repairs (or equivalent as specified in the List of Brand names) in beam bottoms, columns, slabs etc. including mixing with 5mm to 10mm size aggregates, waterproof ply wood/ steel plate shuttering, pouring, temping, Consolidating, curing ete complete as per Manufacturer's specification and Consultants Instructions. The item shall be paid on actual consumption of Micro concrete. Rate of this item shall include chipping of concrete. surface preparation, rust removal and prevention treatment as per specs and in accordance with consultants suggestions and directions.Note: The item shall be paid on actual consumption of Micro concrete. |
| 106 | EPOXY GROUTING: Providing, injecting and grouting High molecular weight Super Low Viscous (3 to 5 cps) 0.56 Kg/cm2 Epoxy Thermoset Resin Monopol (Krishna Conchem or equivalent) for Slab/Beams/Columns in appropriate proportion as per manufacturer's specifications into cracks / honeycomb area of concrete including drilling minimum 50 mm deep holes of required dia. in concrete, fixing nipples 8 / 10mm dia., injecting grout by suitable gun / pump at 1,0 to 2.0 Kg/em2 pressure and subsequent cutting / removal of the nipples and sealing of the hole and groove after completion of grouting with cement / epoxy mortar as directed by the Engineer in-charge. Rates to include searching the cracks, opening the same, fixing the nozzles & making all other provisions as per the manufacturer specification/ instructions to make the water tight structure only the affected area. Make: Sunanda, Pidilite, Krishna Conchem, BASF, Fosroc |
| 107 | M&L for Brick work with common burnt clay machine moulded perforated bricks of class designation 12.5 conforming to IS: 2222 in superstructure, with cement mortar 16 (1 cement: 6 course sand) |
| 108 | M&L for post construction anti- termite traetment along the external wall below concreate or masonary apron using chemical emulsion @2.25 liters per linear meter including drilling and plugging holes with cement morter 1:2 to match the existng floor etc. Complete all as specified and directed. |
| 109 | M & L for post construction anti - termite treatment at points of contract of wood work using chemical emulision (in oil or kerosin based solution) @ 0.5 liters per hole by drilling 6 mm dia holes at a down ward angles of 45 degree at 150 mm centere to center and sealing the same with white cement and making good to the existing surfaces etc Complete all as specified and directed. |
| 110 | M&L for Two coat of synthetic enamel paint over a coat of aluminium red oxide primer to old steel surface including preparation complete all as specified and directed. |
| 111 | Dismantling of Plain or corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern roof coverings. Complete all as specified and directed. |
| 112 | Dismantling wall and ceiling boards (fibre, pulp, insulation etc) or insulation boards / slabs / blankets any thickness including cover fillets. Complete all as specified and directed. |
| 113 | Supply and fixing hot dipped GI imposed grid with 24mm wide T section exposed flanges powder coated frame work comprising of main runner made runner made from 0.33mm thick GS Sheet of size 24 mm x 32mm x 300 mm @1200 mm C/C GI wire 4mm dia fixed by rawl plug, level adjusters and screws etc flush fitting of 1200mm long cross tee interlocked between main runners @ 600mm c/c to form 1200mm x 600mm modules cross tee longer than 600mm to be supported independently 600 mm x 600mm modules shall be formed by fitting 600mm long cross tee centrally between 1200mm cross tee, perimeter wall angle shall be GS of size 19mm x 19mm and 0.45 mm thick 300mm long including 600mm x 600mm x8 to 10mm thick Armstrong gypsum reinforced board with painting with two coat of plastic emulsion paint over primer including taking down of old ceiling. Complete all as specified and directed. |
| 114 | Dismantling wrought iron or mild steel work of any description not otherwise provided for all. Complete all as specified and directed. |
| 115 | S&F Roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel, post or flat sections) including distance pieces, cleats etc. Fe-410- W(Gde-E-250) quality-B including distance pieces, cleats plate etc incl required welding as per relevent IS Complete all as specified and directed. |
| 116 | S&F Pre- painted galvalume aluminum zinc coating GI based orrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws. Complete all as specified and directed. |
| 117 | Pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws. Complete all as specified and directed. |
| 118 | Demolition of cement concrete in ground floor / paving not exceeding 15Cm thick below or above GL unreinforced complete all as specified . |
| 119 | M & L for cement concrete 100 mm thick type, 1 : 2 : 4 B-2 (using 20mm graded stone aggregate) as in drain, floor etc and finishing even and smooth without using extra cement complete all as specified and directed. |
| 120 | Chequered cement concrete tile 20CM x 20CM x 25mm thick with grey cement and pigment set, jointed and pointed in neat cement slurry in floors over and including cement mortar bedding 20mm thick in CM 1 : 4, Complete all as specified and directed. |
| 121 | M&L for Preparation of new steel surfaces of any des-cription, over 10cm in width or grith, not otherwise described and applying two coats of synthetic enamel paint over a coat of red oxide primer. |
| 122 | Material and Labour for point wiring using approved colour coding as per IS ,with multistranded copper conductor 1.5 Sqmm (nominal area), two single core, PVC insulated and unsheathed FRLS cable 1100 Volts grade ISI-694 marked drawn through in and including heavy duty, PVC casing caping with all fittings, accessories, PVC junction boxes etc fixed to walls / ceilings with and including concealed PVC Modular boxes of suitable size, covered with modular white cover plate & frame for mounting modular switches, sockets, regulators and also including PVC insulated multistranded copper conductor 1.5 Sqmm (nominal area) single core FRLS cable as earth continuity conductor along with wiring and connecting to earth dolly all as specified and as directed for the following |
| 123 | One light point/ exhaust fan point controlled by one, one way switch 6 Amps Complete all as specified and directed. |
| 124 | One 5 pin socket outlet plug point, 6 Amps, controlled by one, switch on same board complete all as specified and as directed |
| 125 | One 5 pin socket outlet plug point, 6 Amps, controlled by one, switch on independent board complete all as specified and as directed |
| 126 | One two way light point controlled by two nos. two way 6A switches complete all as specified and as directed |
| 127 | One bell point controlled by one, one way switch 6 Amps complete all as specified and as directed |
| 128 | One light point controlled by one, one way switch 6 Amps but below the switch board of light points in the same vertical plane, complete all as specified and as directed |
| 129 | One ceiling fan point & regulator controlled by one, one way switch 6 Amps complete all as specified and as directed |
| 130 | Description all as per Item No 115 here-in before but using 2.5 Sqmm single core copper conductor FRLS cable of multistranded PVC insulated unsheathed 1100 Volts grade, for one 6 pin socket outlet plug point, 6 Amps independent including necessary running of 2.5 Sqmm PVC insulated multistranded copper conductor single core FRLS cable as earth continuity conductor along with wiring and connecting to earth dolly all as specified and as directed |
| 131 | Description all as per Item No 115 here-in before but using 4.0 Sqmm single core copper conductor FRLS cable of multistranded PVC insulated unsheathed 1100 Volts grade for 6/16 Amps power point including necessary running of 4.0 Sqmm PVC insulated multistranded copper conductor single core FRLS cable as earth continuity conductor along with wiring and connecting to earth dolly all as specified and as directed |
| 132 | Note for Item No 115 to 117: (i) Cutting chases for conduits and sinking's for PVC switch boxes and making good to walls in cement mortar 1:3 to match with existing surfaces shall be carried out by the contractor without any extra cost from the department.(ii) Maximum 08 Nos of - Light, fan, 6 A Sockets Points and Maximum two power Points shall be connected on 01 Circuit controlled by one SP MCB. ( Submain wiring for light Circuit from DB MCB to Switch Board of 2.5 Sqmm shall deemed to be included in the unit rate quoted. |
| 133 | Taking down carefully unserviiceable copper/aluminium point wiring (light, fan, socket or power) complete, (fittings such as switches, ceiling roses, pendants, regulators sockets etc. to be measured separately), removing materials to store for keeping in safe custody for reuse at site and making good disturbed surfaces of walls, floors, etc. |
| 134 | Supply and fixing Modular switch, one way 6 A, one module, 230 Volts complete all as specified and as directed. |
| 135 | Supply and fixing Modular switch, Two way 6 A, one module, 230 Volts complete all as specified and as directed. |
| 136 | Supply and fixing Modular Bell push 6A ,one module 230 Volts complete all as specified and as directed. |
| 137 | Supply and fixing Modular switch, one way 16 A, one module, 230 Volts complete all as specified and as directed. |
| 138 | Supply and fixing Modular socket outlet multipurpose, 6A - 2/3 pin combined 2 module, 230 Volts complete all as specified and as directed. |
| 139 | Supply and fixing Modular socket outlet multipurpose, 6A/16A - 2/3 pin combined 2 module, 230 Volts complete all as specified and as directed. |
| 140 | Supply and fixing 25A combined unit (G-Power) with concealed metal box with 4M Wavio Plate + 25A MCB + 25A Socket + 16A Magnus plug top.Make- GM Cat No AA 4 068) or equivalent in Legrand complete all as specified and as directed. |
| 141 | M & L Ceiling rose, 3 terminal /PVC/ polycarbonate, isolated body complete all as specified and as directed. |
| 142 | Supply and fixing electric, Ding Dong bell suitable for operation on AC. 230 volts, single pole complete all as specified and as directed. |
| 143 | Supply and fixing modular stepped type electronic fan regulator flush type, 120W - 2 module suitable for 230V 50Hz AC supply complete all as specified and as directed. |
| 144 | Supply and fixing energy saving, Full Glow LED Surface Light luminaire complete with Motion Sensor, Power consumption 15 Watt, Round Shape, single Phase 230 Volt. fitting and standard warranty of manufacturer from date of purchase/ installation all as specified and directed. |
| 145 | Supply and fixing, LED- 2 Feet, 10 watt- Power consumption, Input Voltage: 220-240V AC, 50 Hz, wall / surface mounted Energy-efficient Stepless Dimming Feature lighting luminaire, equipped with, Integrated Powered electronic driver and Motion Sensor – Automatic on/off with motion detection Sensor Range upto 5 Mtrs, Polycarbonate material, including with output short circuit protection, surge protection, other safety tests, system efficacynot less than 100 lumens / watt, Make Philips Model No - MSPC10W or equivalent in orient, Jaquar complete all as specified and as directed |
| 146 | Supply and fixing, LED- 4 Feet, (1200mm) Linear Design, 20 watt, Power consumption, Input Voltage: 220-240V AC, 50 Hz, wall / surface mounted Energy-efficient Stepless Dimming Feature lighting luminaire equipped with, Integrated Powered electronic driver and Motion Sensor – Automatic on/off with motion detection Sensor Range upto 6 Mtrs, High quality Plastic and aluminium housing material including with output short circuit protection, surge protection, other safety tests, system efficacy not less than 100 lumens / watt. Complete all as specified and as directed |
| 147 | Supply and fixing Energy efficient, Twinglow 25-Watt+25-Watt Led Up-Down Batten (Warm White + Cool White), polycarbonate material, 4' Tubelight fitting, 2500 Lumen complete with standard warranty of manufacturer from date of purchase/ installation all as specified and directed. |
| 148 | Supply and Fixing Fully recessed floor & step light with casaviva support frame & plate 240V~ 50-60Hz 4 MODULE (Code- AA 4 148 WW) Make- GM Glossy white Accent Light Luminaire fitting with LED warm white complete all as specified and as directed |
| 149 | Supply and Fixing Decorative, Wall mounted, Pixel Backlit Led Smart Touch Sensor , Smart One Touch On / Off, Cable exit from centre, Bath room Mirror of size of 18x24 inches complete all as specified and directed. |
| 150 | Supply and fixing High Efficient , Roadway ( street) Lighting Luminaire, LED 25 Wattage system as light source, Powered by an integral electronic driver with output short circuit protection, surge protection & other safety tests, with aluminium pressure die-cast housing, toughened glass in the front and peanut lens for batwing light distribution, and maintenance-free system fitting of including Clamps of adequate size / Length, wall fastners, Nuts bots washers and GI pipe medium grade Pipe 32mm dia 1.5 mtr long bend to required shape for fixing fitting with wall complete all as specified and as directed. |
| 151 | Supply and fixing, fresh air (exhaust) fan plastic body of 150mm sweep, AC single phase, 240V, 50 Hz, Input Voltage, 140-285, , with louvers and including three core copper conductor flexible cord of 0.5 sqmm cross sectional area of required length from ceiling rose to PVC connector block of fan and taking down old exhaust fan carrying to deposit in AGE E/M store yard Hamla complete all as specified and directed. |
| 152 | Supply and fixing, fresh air (exhaust) fan plastic body of 200mm sweep, AC single phase, 240V, 50 Hz, Input Voltage, 140-285, , with louvers and including three core copper conductor flexible cord of 0.5 sqmm cross sectional area of required length from ceiling rose to PVC connector block of fan and taking down old exhaust fan carrying to deposit in AGE E/M store yard Hamla complete all as specified and directed. |
| 153 | Note for Item Ser No 131 to 137:PVC insulated and PVC Round Sheathed, 0.50 Sq.mm 3 Core Multicore Annealed Bare Copper Conductor (flexible) cable ofVoltage Grade 1100 Volt, Conforming to IS 694 : 2010 & PVC connectior for connecting cable felling short of length Provided by OEM with tube light/ fan shall be provided by contractor without any extra cost from the department. |
| 154 | Labour for taking down of unserviceable ceiling fan of any sweep and make after disconnecting cable end terninal from ceiling rose, dismantling blades and hanging serviceable fan at same location of any sweep, make by connecting cable end terminal to ceiling rose, after fixing blades at site with fan, testing for smooth running complete all as specified and as directed. |
| 155 | Note: Transportation to & fro involved of unserviceable ceiling fan to deposit in EM Store yard Hamla and back to site hanging serviceable fan after collecting from store is deemed to be included with unit rate. |
| 156 | M & L for taking out old paint of ceiling fan (any size) with paint remover liquid, Preparing smooth surfaces for painting, cleaning all dust etc, filling cavities with filler, and Painting with spray application of complete ceiling fan, blades with white rust proof synthetic enamel paint complete all as specified and as directed. |
| 157 | Taking down carefully existing unserviceable main switch /cutout /DBs of any type, capacity and description and removing materials from site and making good disturbed surfaces of walls, floors as per the existing finishes all as specified and as directed. |
| 158 | S & F sheet metal enclosure suitable for Flush Mounting and Surface Mounting, MCB DB with 100 Amps rated bus bar, Fully shrouded Neutral bars, Earthbar and Cable ties for Cable management, 240 Volts, IP 43 - #IK 09 with metal double door & magnetic locking system including inserting the DBs in wall by cutting the brick/ stone masonary etc and making good of disturbed surface to match the existing colour of wall complete all as specified and as directed. |
| 159 | (a) SPN 8 Way. |
| 160 | Supply and fixing amp rating 240V, 10KA 'C' curve, IP 20 protected terminals, miniature circuit breaker (MCB) of following poles and current carrying capacity in the MCB DB complete with connection testing and commissioning. |
| 161 | (a) SP 5 To 32 AMP |
| 162 | (b) SPN 32 AMP |
| 163 | Taking down of old unserviceable sub main wiring of any type complete all as specified and as directed. |
| 164 | M & L for submain wiring with approved colour coding as per IS with two single core PVC insulated FRLS multistranded copper conductor cable of size 6 Sqmm nominal area and drawing into PVC non metallic rigid heavy duty conduit and its accessories (ISI marked) of suitable size including PVC insulated multistranded copper conductor 6 Sqmm (nominal area) single core FRLS cable as earth continuity conductor along with submain wiring and connecting to earth dolly complete all as specified and as directed.Note- Three run of 10 Sqmm cable and one run of PVC conduit will be measured as one unit complete all as specified and as directed. |
| 165 | Supply and fixing Medium duty SS 304 CABLE PERFORATED TRAYS, rust proof, in standard length of 2.5 Mtr, thickness - 3.0 mm, and height of tray 50mm complete with side SS couplers plates to connect cable trays with each other, SS couplers cable tray bends, and supporting accessories of GI (Galvanized Iron) Threaded Rods, Fasteners, with nuts, bolts, washers etc for fixing cable tray on walls or hanging with ceilings all as specified and as directed complete width of |
| 166 | (a) Cable Tray 150mm |
| 167 | (b) Cable Tray 200mm |
| 168 | Material and Labour for Radium Vinyl Sticker, (Thickness 0.2mm,) water proof, wear resistant back with sticker, Resistant to fading, cracking, and peeling, colour as directed by Engnr-in- Charge, for Numbering Fan - GE(NW) / E&M / CF / 001 / MES- HAMLA) / Geyser - GE(NW) / E&M / GEY / 001 / MES- HAMLA) any type, cut to customizable size font in size 1\\" Height and width not less than 10 mm with letters as complete all as specified and as directed. Note- Ser No i.e 001 will change on each ceiling fan. |
| 169 | Disconnecting water and electric connections from existing position of geyser capacity 25/50 ltr, taking down geysers fixed to walls at any height, transporting to/ depositing in MES store yard for inspestion of Engineer-in-Charge to ascertain the serviceability / unserviceability and quantam of repairs involved including transportation of serviceable geyser capacity 25/ 50 Ltr from workshop to building site as directed for fixing in existing position making water and electric connections and testing complete as directed. |
| 170 | Repairs/ servicing to geyser capacity 25/ 50 Ltr involving the following operations. (a) Dismantling (opening) of geyser complete in MES yard / workshop part by part of all the stationary parts, cleaning the covers and parts as applicable(b) Servicing, cleaning of geyser accessories and parts as applicable such as inner tank body, water inlet/ outlet assembely, heating element etc descaling with acid wash all as directed by Engineer-in-Charge.(c) Assembling of geyser complete with old serviceable parts, replacement of unserviceable parts by new as ordered, renewal of nuts bolts and washers, rubber gasket, complete as directed by Engineer-in-Charge. |
| 171 | Note:-(i) Parts required to be replaced shall be measured and paid separately as \\"supply only \\" against relavant item (s) of this schedule. However, labour element involved in replacement is included in unit rate quoted against this item.(ii) Any minor parts / repairs involved to make the geyser completely functional even if not notified by Engineer-in-Charge shall be carried out by the contractor without any extra cost to the Department. |
| 172 | Supply only the following Provisional Items to incorporate against item No 147 Here-in- before. |
| 173 | Heating Element for Geyser cap 25 Ltrs, supply Voltage 220-240 Volts AC, 2000 Watts suitable to Make and size as required at site. |
| 174 | Universal Mother PCB Board, Connector And Wires Display, Sensor, copper Material, for Geyser cap 25 Ltrs,supply Voltage 220-240 Volts AC, 2000 Watts, suitable to Brand Make and size of any as required at site. |
| 175 | Thermostat, supply Voltage 220-240 Volts, of any Type ( Push Button/ Mechanical/ Temperature) suitable to Make and size as required at site. |
| 176 | Supply and Fixing 15 mm Bore angular Stop cock with wall flange cast copper alloy, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed complete all as specified and as directed.Make Jaquar Model OPP-CHR-15053PM or Kholer- Model K-80158IN-9-CP ( Nickel) |
| 177 | M & L for PVC connection pipe (copper) chromium plated 8 mm dia both end threaded incl brass coupling bolt cone washer complete , length of pipe not less than 600 mm suitable for Hot / cold water system complete as all specified and directed. |
| 178 | Disconnecting of electrical connection securely and dismantling old conventional energy meter of any capacity from the electrical panel and depositing in MES store, complete all as specified and directed by Engr-in-Charge. |
| 179 | Design, supply, install, testing and commissioning of Factory made, indoor type padestal mounted, totally enclosed, dust and vermin proof, power distribution system, LT cubical panel Board suitable for 500V, 3 phase, 4 wire, 50 Hz, of adequate size with double stud hinged door, front and rear openable along with locking arrangement duly fabricated out of Stainless Steel Sheet rust proof (outerbody and covers) & Inner body/ door covers of sheet not less then 2.0 mm thickness, & internal wiring complete with copper bus bar to be provided through out the length of the panel for incoming, outgoing feeders and electric Meters accommodated in a modular multitier arrangement and interlocked to avoid paralleling, adequate size cable alley comprising and housed in compartments with the Accssories/Fixtures and Fittings mentioned here-in-after including mounting LT panel on PCC Platform all round as recommended by OEM complete and setting aside old unserviceable LT Panel Board all as specified and as directed. |
| 180 | The following accessories / Fittings and fixtures are required to be fitted in- housed in the LT Panel Board :- |
| 181 | (A) INCOMING |
| 182 | (a) 400 Amps rated copper bus bar TPN duly insulated with coloured PVC Sleeve as per Standard Colour Code and rigidly mounted on Bakelite /DMC insulator Bus bar support (Square / round) insulators of suitable size and good insulation resistance. |
| 183 | (i) MCCB 125-160 Amp, 4 Pole 415 V 25 KA- 01 Nos (Main Incomer) |
| 184 | (ii) Multi Function Meter Make L&T Cat No-WL440511OOOO-01 |
| 185 | (iii) Phase indicator lamps (RYB) - 01 set |
| 186 | (B) OUTGOING |
| 187 | (i) MCB SPN 40 Amps -7 Nos |
| 188 | (ii) Electronic meters LCD display, 230 V, 10- 60 Amp,-7 Nos |
| 189 | Material & labour for Earthing using galvanised iron earth plate electrode of size 60cm X 60cm X 6mm thick burried directly in ground vertically at a depth not less than 2.25 mtr below normal ground level with top edge of earth plate at a depth not less than 1.5 mtr below normal ground level, earth plate surrounded from all sides by 15 cm thick and packed layer of charcoal dust and common salt filling in alternate layers including refilling with good earth as specified and electrode connections by using galvanised wire of 4 Sqmm size by means of bolts, nuts, check nuts and washers made of GI and provision of GI pipe medium grade 15 mm dia for protection of earthing lead and 20mm dia for watering arrangement including funnel, wire mesh, CI pit cover and PCC chamber pit with PCC 1:2:4 type B-2 (including necessary excavation and earth work disposal of surplus soil to a distance not exceeding 50 mtr all as specified and shown on plate No 5 of SSR Part-I 2009. |
| 190 | Deduct Credit for Demolished/ Dismantled material Rs. (-) 55,025.00 (Minus) as listed in Schedule of Credit Note 1:- Tenderers will not quote against this item being a tentative amount to be considered to arrive at the 'Contract Sum'.Note 2:- The tenderer must keep in mind when quoting rates against items out in multiple storey bldg having height 4 mts to 7 mts. Necessary scaffolding and saftey measures required during execution of work are including in this items. Please Enable Macros to View BoQ information |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail