| 1 | Taking down existing water proofing treatment of any description incl PCC padding, cement plaster any thickness from roof surfaces, cleaning of roof and prepairing it for further treatment incl make good necessary dubbing out wherever required and removing rubbish from site complete all as specified and directed. |
| 2 | M & L for screed plaster 10mm thick in CM (1:4) on fair faces of brick work or concrete surfaces mixed with WPC incl necessary doubingout etc finished even and smooth for laying WPT without using extra cement complete all as specified and directed. |
| 3 | M&L for coved fillet in PCC 1:2:4 type B-0 using 12.5mm graded crushed stone aggregate at junction of roof & parapet wall and other vertical surfaces 75mm radius and surface painted with a hot paving bitumen grade 30/40 conforming to IS-73 @0.70 Kg/Sqm over a coat of bituminous primer conforming to IS-3384 @ 0.30 Ltr Sqm complete all as specified and directed |
| 4 | M & L for APP modified polymeric water proofing membrane, 3mm thick having centre core not less than 100 micron high molecular high density polythylene film (HMHDPE) protected on both sides with high polymeric asphaltic mix and 20 micron HMHDPE film weight not less than 3.00Kg/Sqm applied with bonding material using blown type bitumen conforming to IS-702 grade 85/25 @1.20 Kg/Sqm over bitumen primer conforming to IS-3384 @0.40 Kg/Sqm with final coat of bonding bitumen grade 85/25 @1.20 Kg/Sqm over APP membrane with all overlaps complete all as specified and directed. |
| 5 | M & L for PCC 40mm thick (minimum Consolidated thickness) Type B-0 (1:2:4), using 12.5 mm graded crushed stone aggregate as in padding finished even and smooth without using extra cement with existing slope with V shaped groves 6mm wide and 10mm deep @ 0.60 metre spacing both bays or part there of on top of padding and filled with mastic bitumen of 1:1 preparation complete all as specified and directed. |
| 6 | Dismantling loose /disintegrated portion of RCC Chajjas, bend shelves, beams balconies and similar work at any position or any height and dobbing out with PCC 1:1:5:3, 15mm to 50mm thick using 6 to 12mm graded stone aggregate to make up and finished required shape including applying anti corrosive paint on exposed surfaces of reinforcement and provision of necessary supporting form work and including 10mm thick plastering in CM 1:4, finished fair and even, complete all as specified and directed. |
| 7 | Demolition of brickwork or stone/boulder masanory, laid dry below or above ground level and removing material from site complete all as specified and directed. |
| 8 | M & L for brick work with old size fly ash bricks straight or curved on plan exc. 6 M mean radius built in CM 1:6 complete all as specified and directed. |
| 9 | M&L for walling Random rubble masonary uncoursed well bonded bedded and solidly hearted and built in cement mortar 1:6 etc complete all as specified and directed. |
| 10 | M & L for walling Random rubble masonary (but except stone) uncoursed well bonded bedded and solidly hearted and built in cement mortar 1:6 etc complete all as specified and directed. |
| 11 | Taking down cement plaster from brick walls/stone masonry walls, concrete surfaces including raking out joints, hacking for keys, scrubbing down with water etc complete all as specified and directed. |
| 12 | M & L for rough cast plaster using crushed stone of size between 6 mm to 10 mm, coarse sand and cement mixed in the ratio of (1:1:1) over and including rendering coat of 15 mm thick on fair faces of brick work or concrete surfaces or stone masonry surfaces or other than fair faces of brick work or on one side of lathing (on vertical surfaces) in cement mortar 1:4 finished even and fair complete all as specified and directed. |
| 13 | M & L for 15mm thick rendering on fair faces of brick work/stone masonry, concrete surfaces (external walls) or stone walls upto tripple storey bldgs in cement mortar 1:4 mixed with liquid water proofing compound using as per manufacturer’s instructions, finished even and fair, complete all as specified and directed. Note : WPC shall be measured and paid separately. |
| 14 | Supply only liquid water proofing compound ( For external plaster surfaces) complete all as specified and directed |
| 15 | M & L for applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance,dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces complete all as specified and directed. |
| 16 | Demolition and breaking up of rain water pipe /UPVC pipe line 100mm/75mm dia incl all fittings, complete all as specified and directed. |
| 17 | M & L for 110mm dia UPVC, soil waste drain pipe/ rain water pipe, type ‘A’ , conforming to IS 13592-1992, single socketed, in any length with rubber rings joints or jointed with solvent cement joint, laid in floors or walls etc complete all as specified and directed.(Note- Rubber rings for pipes and fittings shall be conforming to IS 5382-1985) |
| 18 | Dismantling structural steel work including doors gates but excluding framed truss etc complete all as specified and directed. |
| 19 | S & F for framed work such as grills, gratings, cooler stands etc., with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe 290 Gde E-165 incl necessary fixing to walls complete all as specified and directed. |
| 20 | M & L for two coat of synthetic enamel painting to steel surface of any description, not otherwise described over 10cm width or girth including preparation of new surfaces over a coat of red oxide primer complete all as specified and directed. |
| 21 | S & F for pre-painted galvatume aluminium zinc coating GI based corrugated steel sheet 0.50 mm thick of any colour having 550 Mpa tensile strength as in roof covering/cladding and fixed with self tapping screws, complete all as specified and directed. . |
| 22 | M & L for PCC (1:3:6) type C-1 using 20mm graded stone aggregate, 75mm thick as in plinth protection/flooring etc. finished fair & even laid in alternative bays n. exc 2M in length and joints filled with bitumen mastic 1:3 complete all as specified and directed. |
| 23 | Dismantling of existing unserviceable RCC/PVC water tank and S & F 500 litre capacity rotational moulded polythene water storage tanks double layer (cylindrical vertical with closed top) hoisted & fixed in position complete all as specified and directed. |
| 24 | Dismantling of existing unserviceable RCC/PVC water tank and S & F 1000 litre capacity rotational moulded polythene water storage tanks double layer (cylindrical vertical with closed top) hoisted & fixed in position complete all as specified and directed. |
| 25 | Taking down old unserviceable 15mm GI tubing, fittings and connections and removing from site or keeping aside for refixing complete all as specified and directed. |
| 26 | Taking down old unserviceable 20mm GI tubing, fittings and connections and removing from site or keeping aside for refixing complete all as specified and directed. |
| 27 | Taking down old unserviceable 25mm GI tubing, fittings and connections and removing from site or keeping aside for refixing complete all as specified and directed. |
| 28 | S & F in repairs 15 mm bore steel water tubes, medium grade, galvanized with all fittings in short lengths, ISI marked fixed to walls or laying in floors etc complete all as specified and directed. |
| 29 | S & F in repairs 20 mm bore steel water tubes, medium grade, galvanized with all fittings in short lengths, ISI marked fixed to walls or laying in floors etc complete all as specified and directed. |
| 30 | S & F in repairs 25 mm bore steel water tubes, medium grade, galvanized with all fittings in short lengths, ISI marked fixed to walls or laying in floors etc complete all as specified and directed. |
| 31 | Refixing old 15mm GI tubing galvanised with new fittings and fixed to walls, ceiling or laid in floors trenches including necessary cleaning, cutting, screwing complete all as specified and directed. |
| 32 | Refixing old 20mm GI tubing galvanised with new fittings and fixed to walls, ceiling or laid in floors trenches including necessary cleaning, cutting, screwing complete all as specified and directed. |
| 33 | Refixing old 25mm GI tubing galvanised with new fittings and fixed to walls, ceiling or laid in floors trenches including necessary cleaning, cutting, screwing complete all as specified and directed. |
| 34 | Taking down old unserviceable 25mm GI tubing, fittings and connections and removing from site or keeping aside for refixing complete all as specified and directed. |
| 35 | S & F 15mm GI water tubing( Concealed type), medium grade, galvanised with all fittings (and fixed to walls, ceiling or laid in floors/ trenches complete all as specified and directed. |
| 36 | S & F 20mm GI water tubing, medium grade, galvanised with all fittings (and fixed to walls, ceiling or laid in floors/ trenches complete all as specified and directed. |
| 37 | S & F 25mm GI water tubing, medium grade, galvanised with all fittings (and fixed to walls, ceiling or laid in floors/ trenches complete all as specified and directed. |
| 38 | S & F in repair 20mm dia ball valves high pressure of PTMT with epoxy coated aluminium rod and high density plastic ball screwed for iron pipe (minimum weight 210 grams) complete all as specified and directed. |
| 39 | Cleaning of water tank, Disconnecting existing water tanks, setting asides (or lowering if required) for repairs, cleaning and removing all scale and dirt etc from tanks, and from mouth of circulating pipes etc and re-fixing reconnecting in same position, of capacity exc 250 ltrs and not exc 500 ltrs each etc complete all as specified and directed. |
| 40 | Cleaning of water tank, Disconnecting existing water tanks, setting asides (or lowering if required) for repairs, cleaning and removing all scale and dirt etc from tanks, and from mouth of circulating pipes etc and re-fixing reconnecting in same position, of capacity exc 500 ltrs and not exc 1000 ltrs each etc complete all as specified and directed. |
| 41 | Surface excavation in hard/dense soil not exceeding 30cm deep and averaging 15cm deep and getting out, complete all as specified and directed. |
| 42 | Excavating in trenches, not exc 1.5m wide and not exc 1.5m in depth; for foundation etc. or for shafts, wells, cesspits, manholes, pier holes etc. not exc 10 sq. m on plan and not exc 1.5m in depth and getting out in any kind of soil, Rock etc complete all as specified and directed. |
| 43 | Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm in hard/dense soil, complete all as specified and directed. |
| 44 | M & L for removing excavated any kind of soil, Rock n exc. 50m and depositing where directed at a level n exc. 1.5m above the starting point complete all as specified and directed. |
| 45 | M & L for PCC 1:4:8 Type D2 40mm graded aggregate as in foundations, filling and mass concrete complete all as specified and directed. |
| 46 | M & L for mild steel TMT bars of 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed. |
| 47 | M & L for mild steel TMT bars of 6mm to 8mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and as directed by the Engineer-in-Charge |
| 48 | M & L for RCC M-25 grade (design mix) using 20mm graded aggregates as in foundations, including rafts, footings, foundation beams, plinth beams, bases for columns, etc, basement slabs, under reamed piles and mass concrete complete all as specified and directed. |
| 49 | M & L for formwork to sides of concrete foundations, footings, bases of columns, raft and beams, sides and soffits (if any) of foundation and plinth beams , and similar work, vertical or to batter, flat surfaces of concrete , surface is required to be fair finished complete all as specified and directed. |
| 50 | M & L for M-25 grade (design mix) using 20mm graded aggregates as in columns, pillars, piers, posts and struts complete all as specified and directed. |
| 51 | M & L for formwork to sides of pillars, posts, struts, piers, columns and stanchions, rectangular or polygonal surfaces of concrete , surface is required to be fair finished. complete all as specified and directed. |
| 52 | M & L for RCC M-25 (design mix) using 20mm graded aggregates as in Roof beams, lintel beams/bands, cantilevers, bressummers, lintels over 1.5m span, chajjas etc complete all as specified and directed. |
| 53 | M & L for formwork to sides and soffits of floor or roof beams, soffits of lintel beams/ bands, chajjas, beam haunchings, girders, bressum-mers, lintels, cantilevers, shelves including supports overhangs etc, also splays between floors and beams, etc., flat surfaces of concrete , surface is required to be fair finished. complete all as specified and directed. |
| 54 | M & L for RCC M-25 (design mix) using 20mm graded aggregates as in slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified and directed. |
| 55 | M & L for formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping), flat surfaces of concrete , surface is required to be fair finished. complete all as specified and directed. |
| 56 | M & L for brickwork with fly ash bricks, in straight or curved on plan exc 6m mean radius, built in CM 1:6 complete all as specified and directed. |
| 57 | M & L for Rendering 15mm thick in cement plaster 1:4 on fair faces of brick work or concrete surfaces even & fair. complete all as specified and directed. |
| 58 | M & L for preparation of new plastered of wall and applying Two coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm, over and over two coat of exterior primer applied @ 0.90 litre/ 10 sqm over plastering surfaces, complete all as specified and directed. Make :- ASIAN/APEX/BERGER (Weather coat all guard) |
| 59 | M & L for rendering 15 mm thick in cement mortar 1 : 6 on fair faces of brick work or concrete surfaces including finished even & fair surfaces without using extra cement. complete all as specified and directed. |
| 60 | M&L for Distempering with 1st quality acrylic distemper(ready mixed) having VOC content less than 50 gms/litre, of approved manufacturer, of required shade and colour complete, as per manufacturer's specification. Two or more coats on new work over Providing and applying plaster of paris putty of 1 mm thickness over plastered surface to prepare the surface even and smooth complete all as specified and directed.. |
| 61 | M & L for vitrified ceramic tiles light shade8-10mm thick (square / rectangular ) polished, area of each tiles exc 0.18 Sqm not exceeding 0.36 Sqm, in floor etc set and jointed in neat cment slurry and pointed in white or coloured cement to match including screed bed 15mm thick in CM 1:6 complete all as specified and directed. |
| 62 | M & L for vitrified ceramic tiles light shade 8-10mm thick (square / rectangular ) polished, area of each tiles exc 0.18 Sqm not exceeding 0.36 sqm, in vertical surfaces such as skirting, dados etc set and jointed in neat cement slurry and pointed in white or coloured cement to match including screed plaster 10mm thick in CM 1:4 complete all as specified and directed. |
| 63 | M & L for 100mm thick cement concrete type D-2 1:4:8 using 40mm graded aggregate , as in sub base. complete all as specified and directed. |
| 64 | M&L for aluminium powder coated door frame and shutter including top, bottom/middle rail using glazing clip including rubber head and float glass 6mm thick tinted provided with one floor spring hydraulically regulated made up of minimum 1.25mm thick aluminium alloy sheet foundation box main body with stainless steel cover governing pivot made of brass other parts made of mild steel heavy duty fixed to aluminium door and other fittings like handle, locking system, push plate and necessary beading all around the door shutter frame as required for resistance complete all as specified and directed and as per Chief Engineer Drg. |
| 65 | M&L for aluminium powder coated sliding window, ventilator three track including aluminium powder coated decorated grill sliding shutter 5mm thick tinted float glasses, necessary aluminium beadings fittings and other panels to prevent air from out side complete all as specified and directed and as per Chief Engineer Drg . |
| 66 | M & L for hardcore of broken stone or boulders gauge n exc. 63mm, deposited, spread and levelled in layers n exc. 15cm thick, watered and remmed to a true surface, complete all as specified and directed. |
| 67 | M&L 75mm thick PCC 1:3:6 type C-1 as in plinth protection finished fair and even without using extra cement n exc 2m in length and joints filled with bitumen mastic (1:1) complete all as specified and directed |
| 68 | M & L for 100 mm thick PCC 1:4:8 type D-2, using 40 mm graded stone agg as in sub base etc complete all as specified and directed. |
| 69 | M&L machine pressed precast concrete interlocking paver block any shape and size confirmeing to IS-15658-2006 of 60 mm thick, M-35 grade with grey cement and pigment over 50 mm thick sand cushioning, etc complete all as specified and directed. |
| 70 | M&L for point wiring with 1.5 Sqmm. (nominal area) single core PVC insulated 1100 Volts, grade multi stranded FRLS copper conductor unsheathed in and including non metallic rigid PVC concealed conduit 20 mm dia or higher complete with all PVC conduit accessories such as socket, elbow, junction box, bell mouth, reducer, bend and flexible conduit etc./ fittings ISI marked and sunk type pressed steel anodised terminal box with bakelite laminated sheet top cover 3 mm thick, brass screws and cup washers including one green colour cable of same size as earth wire up to common earth and connected to earth dolly compete all as specified and directed of following :- |
| 71 | One light point/bell point controlled by one way 5 Amps single pole switch, complete all as specified and directed. |
| 72 | One 5 pin 5 Amps socket outlet on same board with other switch, complete all as specified and directed. |
| 73 | One 5 Pin 5 Amps socket outlet on independent board with other switch, complete all as specified and directed. |
| 74 | All as per item No 70.00 above but with 2.5 Sqmın single core mulli stranded PVC insulated unsheathed (FRLS) cable for 15 Amp socket outlet on independent board, complete all as specified and directed. |
| 75 | S&F f switch piano type, flush button single pole, one way 5 Amps, complete all as specified and directed. |
| 76 | S&F switch piano flush type 15 amps, single pole one way 240 volts complete all as specified and directed. |
| 77 | S&F of socket outlet 5 Amps, 5 Pin, flush type, complete all as specified and directed. |
| 78 | S&F of socket out let 2 in 1, multipurpose 3 pin 15/16 complete all as specified and directed. |
| 79 | S&F stepped type (switch type) electronic celling fan regulator suitable for BLDC Fan complete all as specified and directed. |
| 80 | S&F, ceiling rose, surface type bakelite 65x17.5 mm, three terminals, complete all as specified and directed. |
| 81 | Supply and fixing LED lights fitting 1x 16W, 220V, AC decoralive box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceilling rose complete all as specified and directed. |
| 82 | S&F MCB SP, 240 volt, 6 Amp to 32 Amp capacity, 10 KA, 'C' curve complete all as specified and directed. |
| 83 | S&F MCB SPN 10 to 40 Amp capacity, 10KA, 'C' curve complete all as specified and directed |
| 84 | S&F MCB distribution board single pole & neutral with 200 Amps rated bus bar, double door, IP-43, D6's made out of CRCA sheet steel enclosure, recessed type, factory made powder coated, 4 way, 240 volts suitable for housing MCB's and isolator's complete in all fixing material/ accessories etc complete all as specified and directed. |
| 85 | Supply and fixing ceiling fans complete with blades, down rods and accessories, 230 V. 1200 mm sweep. Min air delivery 210 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor (BLDC) complete with motor, blade set of three nos, down rod, canopy, shackle assy. complete all as specified and directed. |
| 86 | Supply and fixing LED street light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete including treet light bracket made of 32 mm Gl pipe, 1.2 mtr lenght fixed with two nos of clamp, nut and bolts complete all as specified and directed. |
| 87 | Excavation in trenches not exceeding 1.5m wide and not exceeding 1.5 m depth for laying of cable/ stay assy/LT poles and getting out in hard/dense soil complete all as specified and directed. |
| 88 | Returning filing incl spreading watering and well ramming in layers not exceeding 25cm in hard and dense soil complete all as specified and directed. |
| 89 | Removing excavated material not exceeding 50 mtrs and depositing where directed at a level n. exc 1.5mtr above the starting point complete all as specified and directed. |
| 90 | Sand cushioning to underground cable as per clause 19.75 of SSR Part-1 complete all as specified and directed. |
| 91 | Material and labour for un-reinforced pre-cast concrete cable covers, class LV type-1, flat size 250mm x 150mm x 40mm thick complete all as specified and directed. |
| 92 | S & F Gl tubes 40mm, Lightgrade (ISI marked), galvanized iron with and including all fitting (ISI marked) for Cable protection laid in trench/wall/pole etc complete all as specified and directed. |
| 93 | Supply, laying and testing cable XLPE Insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 10 sq mm 2 core complete all a specified and directed. |
| 94 | M & L for earthing complete with GI earth plate electrode 60 cm x 60 cm x 6 mm thick, buried directly in ground (earth pit not less than 2.25 mtr deep below normal ground level) with top edge of the plate not less than 1.5 mtrs below normal ground level connected to GI lead wire 4.00 mm dia by means of bolts, nuts, check nuts and washers of galvanized iron or steel all as shown in electric plate No 3 of SSR Part-I connected to continuous earth wire on main switch board all as specified or indicated and testing on completion including provision of earth wire protection by 15 mm dia medium grade GI pipe and watering pipe shall be 20 mm bore, medium grade including excavation & earth work in any type of soil & disposal of soi, providing alternate layers of charcoal and common salt, constr of PCC earth chamber in mix 1:3:6 type C-1 with 40mm thick RCC 1:2:4 type B-1 cover with handle made out oof 8mm dia bars, watering arrangement with funnel & wire mesh, complete all as specified and directed. Note. : The unit rate includes for protection pipe and GI wire 4.00 mm from top of earth plate up to 7.5 meter above ground level. Please Enable Macros to View BoQ information |
| 95 | M & L for earthing complete with GI earth plate electrode 60 cm x 60 cm x 6 mm thick, buried directly in ground (earth pit not less than 2.25 mtr deep below normal ground level) with top edge of the plate not less than 1.5 mtrs below normal ground level connected to GI lead wire 4.00 mm dia by means of bolts, nuts, check nuts and washers of galvanized iron or steel all as shown in electric plate No 3 of SSR Part-I connected to continuous earth wire on main switch board all as specified or indicated and testing on completion including provision of earth wire protection by 15 mm dia medium grade GI pipe and watering pipe shall be 20 mm bore, medium grade including excavation & earth work in any type of soil & disposal of soi, providing alternate layers of charcoal and common salt, constr of PCC earth chamber in mix 1:3:6 type C-1 with 40mm thick RCC 1:2:4 type B-1 cover with handle made out oof 8mm dia bars, watering arrangement with funnel & wire mesh, complete all as specified and directed. Note. : The unit rate includes for protection pipe and GI wire 4.00 mm from top of earth plate up to 7.5 meter above ground level. Please Enable Macros to View BoQ information |