| 1 | Part - A |
| 2 | Carriage of Materials by Mechanical Transport including loading,unloading and stacking upto 2 KM- Lime, moorum, building rubbish. |
| 3 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : |
| 4 | i) 1:2:4 (1 Cement : 2 coarse sand (zone-III) : 4 graded stone aggregate 20 mm nominal size). |
| 5 | ii) 1:4:8 (1 Cement : 4 coarse sand (zone-III) : 8 graded stone aggregate 40 mm nominal size). |
| 6 | 12 mm cement plaster of mix : 1:4 (1 cement : 4 fine sand) |
| 7 | Providing 8 mm thick false ceiling Calcium silicate perforated tiles of size 595 x595 mm. |
| 8 | Providing and fixing tiled false ceiling of specified materials of size 595x595 mm in true horizontal level, suspended on interlocking metal grid of hot dipped galvanized steel sections (galvanized @ 120 grams/ sqm, both side inclusive) consisting of main \\"T\\" runner with suitably spaced joints to get required length and of size 24x38 mm made from 0.30 mm thick (minimum) sheet, spaced at 1200 mm center to center and cross \\"T\\" of size 24x25 mm made of 0.30 mm thick (minimum) sheet, 1200 mm long spaced between main \\"T\\" at 600 mm center to center to form a grid of 1200x600 mm and secondary cross \\"T\\" of length 600 mm and size 24x25 mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid including, required cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main \\"T\\" runners to be suspended from ceiling using GI slotted cleats of size 27 x 37 x 25 x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm GI adjustable rods with galvanized butterfly level clips of size 85 x 30 x 0.8 mm spaced at 1200 mm center to center along main T, bottom exposed width of 24 mm of all T-sections shall be pre-painted with polyester paint, all complete for all heights as per specifications, drawings and as directed by Engineer-in-charge. - 8 mm thick fully perforated calcium silicate board made with Calcareous & Siliceous materials reinforced with cellulose fiber manufactured through autoclaving process to give stable crystalline structure with minimum compressive strength 225 kg/ sq. cm, bending strength 100 kg/sq. cm , of size 595x595 mm, having perforation of dia. 10 mm with minimum perforated area 18 % with non woven tissue on the back side, having an NRC (Noise Reduction Coefficient) of 0.85, with 50 mm thick rockwool of 48 kg /cum backing. (Acoustic soft fibre tiles of make saint gobain, armstrong, buildwell, everest). |
| 9 | Fixing glazed/ Ceramic/ Vitrified floor tiles with cement based high polymer modified quick-set tile adhesive (Water based) conforming to IS: 15477, in average 3mm thickness. |
| 10 | Providing and laying Vitrified tiles Double charge in floor in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand) jointing with grey cement slurry @3.3 kg/sqm including grouting the joints with white cement and matching pigments etc. The tiles must be cut with the zero chipping diamond cutter only. Laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily. |
| 11 | Providing and fixing ISI marked flush door shutters conforming to IS :2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters: 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws. |
| 12 | Extra for Providing and fixing flush doors with decorative veneering instead of non decorative ISI marked flush door shutters conforming to IS: 2202 (Part I) - On one side only. |
| 13 | Extra for providing lipping with 2nd class teak wood battens 25 mm minimum depth on all edges of flush door shutters (over all area of door shutter to be measured). |
| 14 | Extra for providing vision panel not exceeding 0.1 sqm in all type of flush doors (cost of glass excluded) (overall area of door shutter to be measured): Rectangular or square. |
| 15 | Grouting the joints of flooring tiles having joints of 3 mm width, using epoxy grout mix of 0.70 kg of organic coated filler of desired shade (0.10 kg of hardener and 0.20 kg of resin per kg), including filling / grouting and finishing complete as per direction of Engineer-in-charge. - Size of Tile 600x1200 mm. |
| 16 | Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building including treads, risers all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, edge nosing, moulding, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. - Polished Granite stone slab jet Black, Cherry Red, Elite Brown, Cat Eye or equivalent. |
| 17 | Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling to be paid for separately) : |
| 18 | i) For fixed portion - Polyester powder coated aluminium (minimum thickness of polyester powder coating 50 micron) |
| 19 | ii) For shutters of doors, windows, ventilators & sliding shutters including providing and fixing hinges/ pivots / rollers and making provision for sliding of shutter including fixing of fittings, with locking arrangement wherever required including the cost of EPDM rubber / neoprene gasket / any other accessories required - Polyester powder coated aluminium (minimum thickness of polyester powder coating 50 micron) |
| 20 | Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of Engineer-in-charge. (Cost of aluminium snap beading shall be paid in basic item): With float glass panes of 5.50 mm thickness. |
| 21 | Providing and fixing anodised aluminium grill (anodised transparent or dyed to required shade according to IS: 1868 with minimum anodic coating of grade AC 15) of approved design/pattern, with approved standard section and fixed to the existing window frame with C.P. brass/ stainless steel screws @ 200 mm centre to centre, including cutting the grill to proper opening size for fixing and operation of handles and fixing approved anodised aluminium standard section around the opening, all complete as per requirement and direction of Engineer-in-charge. (Only weight of grill to be measured for payment). |
| 22 | Providing edge moulding to 18 mm thick marble stone counters, staircase steps, Vanities etc., including machine polishing to edge to give high gloss finish etc.complete as per design approved by Engineer-in-Charge. - Granite work. |
| 23 | Extra for fixing marble /granite stone, over and above corresponding basic item, in facia and drops of width upto 150 mm with epoxy resin based adhesive, including cleaning etc. complete. |
| 24 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.Contractor may take in to account if required/necessary at site the complete removal of existing painting surface shall be carried out as per direction of Engineer-in-Charge. Nothing shall be paid on ths account. |
| 25 | Wall painting with acrylic emulsion paint, having VOC (Volatile Organic Compound) content less than 50 grams/ litre, of approved brand and manufacture, including applying additional coats wherever required, to achieve even shade and colour. - Two coats. |
| 26 | Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in - charge. - Nominal concrete 1:3:6 or richer mix (i/c equivalent design. |
| 27 | Hacking of CC flooring, terrazo flooring including cleaning for surface etc. complete as per direction of the Engineer-in-Charge |
| 28 | Dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead. |
| 29 | Dismantling stone slab, terrazo flooring laid in cement mortar including stacking of serviceable material and disposal of unserviceable material within 50 metres lead. |
| 30 | Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete. |
| 31 | Providing and fixing panels of wood polymer composite panel of Approximate size i.e. 156 mm wide and 17 mm total thickness and length 2900 mm. The colour and pattern of the WPC ecology panels shall be wenge dark brown wood colour, of reputed brands or as approved by the Engineer-in-Charge. The WCP panels shall confirm to for its colour appearance, thickness, width and length, falling mass impact resistance, heat Reversion etc. These panels shall be fixed on vertical surface with metallic clips or anchor bolt filled with wooden packing to hold screws and then fixed to the main walls / member if required at site. This item is inclusive of all accessories, packing charges, Transportation, Labour installation complete in all respect as approved by the Engineer-in-Charge at all floors / height. |
| 32 | Providing services for the spacialized jobs from the reputed architect/ interior designer/ architectural agency who are in this business. The services may include the site visit, discussion, preparing of drawings/ supervision and regarding the selection of colour, shade, size of fittings/ fixtures/ interior design etc., whichever required. For the purpose of payment %age above/ below the billed value raised by the expert/architect etc. for providing such service , supported by cash receipt / vouchers shall be considered against this item. |
| 33 | Providing fancy items pertaining to SS work, Decoration work with available decorative material in market as per drawing/ instructions of Engr. in charge with titles/ stone highliter/ Aluminium / steel/ board / Pannel/ Fluted Pannel / Polygranite sheets/ Adhesive/ decorative Moulding/ Rose Gold strips/ decorative pannel lights / decorative Green grass/ Marble pieces/LED lights / Laminates / Veeners / decopaint etc. on walls / floors / ceiling etc,and any other items, items which are not covered under any other item of SOQ. For the purpose of payment %age above the Market rates of material supported by cash receipt / vouchers may be quoted. |
| 34 | Providing and fixing HDHMR Board (ISI Marked) of minimum 09 mm total thickness along-with fixing on vertical surface with necessary screws / anchor bolts to hold board to the main walls / member including cutting to size and shape wherever required at site as desired by Engineer-in-charge. The manufacturers / Brands / Makes of HDHMR Boards to be used in this work shall be Action Tesa /Crostan Panal / Century Ply as approved by Engineer-in-charge. |
| 35 | Assisting in executing various job un-susceptible to measurement and other work which are not including in any items stated above/ scope of works as per instructions of the Engineer-in-Charge. : |
| 36 | i) For this purpose, contractor has to deploy Skilled Labour along-with all requisite tools & tackles for one day (For 8:00 hour), which will be treated as one unit of each operation. |
| 37 | ii) For this purpose, contractor has to deploy Un-skilled Labour along-with all requisite tools & tackles for one day (For 8:00 hour), which will be treated as one unit of each operation. |
| 38 | Part - B (Deduction Item) |
| 39 | Deduction items against which material supplied by contractor shall be received in store for future utilization. |
| 40 | i) Deduct for not fixing ceramica/vitrified floor tiles of any size. |
| 41 | ii) Deduct for not fixing granite stone slab/Kota stone. |
| 42 | iii) Deduct for not fixing panels of wood polymer composite panel. |
| 43 | iv) Deduct for not fixing HDHMR Board. Please Enable Macros to View BoQ information |