| 1 | Demolition of cement concrete in ground floors and pavings n exc 15 cm thickness (below or above ground level) complete all as specified and directed. |
| 2 | Demolition of brick work or stone/boulder masonry built in cement mortar including all quoins, arches, pillars etc complete all as specified and directed. |
| 3 | M & L for Brick work with sub class ‘B’ bricks,straight or curved on plan exc 6m meanradius, built in CM (1:4) complete all as specified and directed |
| 4 | Taking down cement plaster on brick or stone walls etc, including racking out joints, hacking for key, scrubbing down with water etc complete all as specified and directed |
| 5 | M & L for rendering 15mm thick internal surfaces on brick work in CM (1:6) in and finishing surfaces even and fair without using extra cement complete all as specified and directed |
| 6 | M & L for rendering 15mm thick in two layers on external surfaces on brick/concrete in CM 1:4 finished even and smooth without using extra cement complete all as specified and directed |
| 7 | M&L preparing Old plastered surfaces of wall and applying complete wall with 1.0 mm Wall putty and making smooth surfaces and applying two coats of Oil bound distemper over a coat of primer all as specified and directed. |
| 8 | M&L preparing newly plastered surfaces of wall and applying complete wall with 1.0 mm Wall putty and making smooth surfaces and applying two coats of Oil bound distemper over a coat of primer all as specified and directed . |
| 9 | Preparing Old plastered surfaces and applying Two coats of cement base paint on surfaces of walls over one coat of white wash complete all as specified and directed. |
| 10 | Preparing new plastered surfaces and applying Two coats of cement base paint on surfaces of walls over one coat of white wash complete all as specified and directed . |
| 11 | Dismantling stone slab of any description laid beddded & pointed in any mortar complete specified and directed complete all as specified and directed . |
| 12 | Dismantling floor, hearth or wall tilling including cement mortar bedding , removing serviceable tiles to store and rubbish off the premises complete all as specified and directed |
| 13 | M & L Machine cut Kota stone slab flooring 20-25mm thick over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and mirror polishing over and including screed bed or bedding layer of mortar 20 mm thick Cement Mortar (1:6) complete. (Note : Work will be carried out as in repair of patches in lieu of existing broken flooring) |
| 14 | M & L Machine Kota stone slab 20-25 mm thick in riser of steps, skirting, dado and pillar laid over cement screed and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing and incl 10mm thick rendering in cement mortar 1:4 , on fair faces of brick work or concrete surfaces as backing complete.(Note : Work will be carried out as in repair of patches in lieu of existing broken flooring) |
| 15 | M & L for PCC (1:2:4) type B-1, 25 mm thick, using 20mm graded stone aggregate complete all as specified and directed |
| 16 | M & L for PCC (1:2:4) type B-0, (1:2:4) (12.5mm graded aggregate), 40 mm thick complete all as specified and directed |
| 17 | M&L for granite (any type) work (table rubbed and polished) 18 to 20 mm thick in working platform and like including cutting for sink etc. in cement mortar (1:4) including rounding of edges and pointing in white cement (1:2) using marble dust with admixture of pigment to match complete all as specified and directed by engr in charge. |
| 18 | M & L for Non - skid Ceramic tiles 7 to 8 mm thick area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm, in floors etc. set and jointed in neat cement slurry andpointed in white or coloured cement to match and incl 15mm thick screed bed or bedding layer with CM (1:4) complete all as specified and directed by engr in charge.Notes : Shade of the tile including colour, design and pattern shall be approved by GE. |
| 19 | M & L for Non - skid Ceramic tiles 7 to 8 mm thick area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm, in Skirting etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match and incl 10mm thick backing coat with CM 1:4 complete all as specified and directed Notes : Shade of the tile including colour, design and pattern shall be approved by GE. |
| 20 | M&L Non - skid Ceramic tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match including 15mm thick screed bed in C:M 1:4 etc. complete all as specified and directed Notes : Shade of the tile including colour, design and pattern shall be approved by GE. |
| 21 | M & L for coloured Glazed ceramic tiles in vertical surface 450x300x 7mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match over 10 mm thick backing coat in CM 1:4 complete all as specified and directed by engr in charge.Notes : Shade of the tile including colour, design and pattern shall be approved by GE. |
| 22 | S&F in repair 20mm dia curtain rods fancy type, mild steel chromium plated with fixing brackets, stops, rollers complete all as specified and as directed by Engr-in-charge. |
| 23 | Dismantling of wall and ceiling boards, any thickness including cover fillets complete all as specified and directed.. |
| 24 | S & F of Gl frame work for seamless ceiling comprising of Gl perimeter channnel 0.55 mm thick with two unequal flanges of 20 and 30 mm and web of 27 mm fixed to surrounding wall using nylon sleeves and screws at 450 mm centre to centre/intermediate channel 0.9 mm thick having two equal flanges of 15 mm each and web of 45 mm suspended from soffit at approx 900 mm centre to centre with Gl cleat and steel expansion fasteners with and including ceiling section (not exc 1.2 m length) of 0.55 mm thickness having kurled web of 50 mm and flange of 26 mm each with lips of 10.5 mm fixed to the intermediate channel with connecting clips across the intermediate channel at 457 mm centre to centre complete all as specified and directed |
| 25 | S&F 4 mm thick HPSC (High Pressure steam cured) pre-primed textured designer board, water resistant, be placed in the grid system complete all as specified and directed |
| 26 | Dismantling of asbestos cement corrugated sheets as in roof coverings/Ridge complete all as specified and directed. |
| 27 | Dismantling timber scantlings 40 sq. cm and over in section, in any position complete all as specified and directed. |
| 28 | S & F Pre- painted galvatume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed |
| 29 | S & F Pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed |
| 30 | S & F of Roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing including distance pieces, cleats etc Fe 410 W (Gde E - 250 quality) complete all as specified and directed |
| 31 | M & L for Mild steel screw bolts (machine made) with hexagonal heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal nut, exc 5cm but n exc 10cm long dia of neck is exc 11 mm but n.exc 15 mm complete all as specified and directed |
| 32 | M & L two coats of synthetic enamel painting on steel surfaces exc 10 cm width or girth over one coat of red oxide primer including preparation of new steel surfaces complete all as specified and directed |
| 33 | M & L two coats of synthetic enamel painting on steel surfaces exc 10 cm width or girth over one coat of red oxide primer including preparation of Old steel surfaces complete all as specified and directed |
| 34 | M & L two coats of synthetic enamel painting on wooden surfaces exc 10 cm width or girth over one coat of red oxide primer including preparation of wooden surfaces complete all as specified and directed |
| 35 | Taking down chowkhats or frames not exc 1.5 Sqm ( without taking shutters from the frame). |
| 36 | Taking down chowkhats or frames exc 1.5 Sqm ( without taking shutters from the frame). |
| 37 | M&L for pressed steel door frame size 105 mm x 60 mm made of 1.25 mm thick sheet including necessary fixing lugs, hinges, lock strike plate etc. complete all as specified and directed |
| 38 | M&L for pressed steel door frame size 125 mm x 60 mm made of 1.25 mm thick sheet including necessary fixing lugs, hinges, lock strike plate etc., complete all as specified and directed |
| 39 | M&L for 35mm thick second class hardwood glazed and skelton door shutters (Three panels) open rebated and prepared to receive glass / gauge etc edges of framing plain chamfered or rounded with cut and mitred beads for securing glass/gauges etc with sash bars size of members of shutter as specified in SSR Part-I section 8, clause 8.24 (a) complete all as specified and directed |
| 40 | M&L for 30 mm thick Flush shutters, solid core construction, with block board core plywood face panels on both side, commercial type on both sides including 5 mm thick edging/beading on exposed to view on sides & top complete all as specified and directed by engr in charge |
| 41 | S&F 200mm long aluminium anodised barrel tower bolt and fixed complete all as specified and directed |
| 42 | S&F 150mm long aluminium anodised handle cast type and fixed D Type complete all as specified and directed |
| 43 | S&F alluminum alloy, anodised, cast type or extruded section, sliding door bolt with hasp & staple (bolt type) with fixing clips and bolts and 300 mm long complete all as specified and directed. |
| 44 | S&F Mild steel 300mm ordinary rat tail rod pattern springs including roller and roller plate complete all as specified and directed. |
| 45 | M & L for providing PCC type B0, 1 : 2 : 4, (using 20 mm graded aggregate) as in coping, and hold fast and the like including weathering, slightly rounded or chamfered angles and throating |
| 46 | Taking down of existing GI Tubing 15 mm dia complete all as specified and directed |
| 47 | Taking down of existing GI Tubing 20 mm dia complete all as specified and directed |
| 48 | Supplying and laying as in repair of CPVC pipes 16mm outer dia SDR 11 & Plain CPVC SDR 11 fittings on walls/floors complete all as specified and directed |
| 49 | Supplying and laying as in repair of CPVC pipes 20mm outer dia SDR 11 & Plain CPVC SDR 11 fittings on walls/floors complete all as specified and directed |
| 50 | S & F of CPVC pipes MBTA/FBTA fittings such as tee, elbow, socket and Tank union etc of 16 mm outer dia complete all as specified and directed |
| 51 | S & F as in repair of CPVC pipes MBTA/FBTA fittings such as tee, elbow and socket etc of 20mm outer dia complete all as specified and directed |
| 52 | S & F as in repair of CPVC ball valve/gate valve fittings such as tee, elbow and socket etc of 25 mm outer dia complete all as specified and directed |
| 53 | S&F in repair vitreous china wash basin, white, flat back, size 550 x 400 mm excluding taps, waste chain and plug and porcelain stopper but including brackets , waste coupling complete all as specified and directed |
| 54 | M & L Ball brass valves 25 mm, high pressure, with polythene float and flynut complete, screwed for iron pipe or brass ferrule and fixed complete all as specified and directed |
| 55 | S & F sinks with drainage board made of stainless steel lmm thick kitchen or laboratory with plugs, washers and wastes; including bedding in cement mortar to dwarf wall or including fixing cantilever brackets and connecting union to pipe overall size 915mm x 460mm bowl size 410mm x 330mm x 160mm complete all as specified and directed |
| 56 | S&F in repair rotational three layer moulded polyethylene water storage tanks (cylinderical vertical with closed top) capacity 1000 Ltr hoisted and fixed in position all as specified and directed |
| 57 | S&F for waste coupling of PTMT for 32 mm bore dia of discharge pipe (half or full threaded) Minimum weight 32mm-45gms/40mm-60 gms) complete all as specified and directed by engr in charge. |
| 58 | S&F in repair 15 mm dia pillar taps, cast copper alloy, with capstan heads, chromium plated fancy type , screwed down high pressure, with or without lettered 'Hot' and 'Cold' woth long shanks and flynuts, screwed for iron pipe complete all as specified and directed |
| 59 | S&F PVC connection 15mm size with PTMT nuts of length 600mm complete all as specified and directed . |
| 60 | S&F in repair 15mm dia stop valve / Angle valve chromium plated fancy type screwed down high pressure with crutch or butterfly handle screwed both end for iron pipe or for union complete all as specified and directed by engr in charge. |
| 61 | S&F 110mm PVC(SWR) bend any radius complete all as specified and directed by engr in charge. |
| 62 | S&F 110mm PVC(SWR) junction single(single T) equal or unequal complete all as specified and directed |
| 63 | M&L for PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors or walls of 110 mm bore of pipe including fittings such as bend,tee,l bow complete all as specified and directed. |
| 64 | M&L for PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors or walls of 75 mm bore of pipe including fittings such as bend,tee,l bow etc complete all as specified and directed |
| 65 | M&L 75mm PVC(SWR) floor trap with grating including jointing with solvent cement complete all as specified and directed |
| 66 | S&F in repair aluminium anodised Tubular towel rail, 20mm dia, D type, 60cm long between flanges complete all as specified and directed |
| 67 | S&F Sheet glass shelf assembly consisting of 5.5mm thick sheet glass shelf 12cm wide with chromium plated bracket guard and railing 60cm long . |
| 68 | S & F for 600mm x 450mm bevelled edge mirror or selected quality glass, mounted on 6mm thick AC building board or commercial plywood and fixed to wooden plugs with chroimium plated brass screws and cup washers complete all as specified and directed |
| 69 | S&F of Aluminium powder coated(1/1.2 mtr size) door cills of Any size and descripton all as specified and directed |
| 70 | M&L for welding in repairs n. exceeding 2.50cm in length thickness of metal to be welded n.exc 9mm complete all as specified and directed |
| 71 | M&L for welding in repairs exceeding 2.50cm but n.exceeding 5 CM in length thickness of metal to be welded n.exc 9mm complete all as specified and directed |
| 72 | M&L for 50 mm thick cement concrete 1:4:8 type D-2 using 40 mm graded stone aggregate as in sub base of flooring/ hard standing & finished the surface even & fair complete all as specified and directed |
| 73 | M & L for 15mm thick screed bed or bedding layer in cement mortar 1:4 for laying floor finishes finished even and rough complete all as specified and directed |
| 74 | M&L for Chequered cement concrete tiles 30cm x 30cm x 25mm thick with grey cement and pigment set and jointed in neat cement slurry and pointed in white or coloured cement complete all as specified and directed |
| 75 | M & L for providing cement concrete cas in situ 1:2:4, type B1 (using 20mm graded stone aggregate) in roof kerbs or mud stops, rounded or chamfered on edge including use of formwork complete all as specified and directed |
| 76 | S & F Powder coated aluminium frame/shutters for windows, ventilators sliding/openable etc icluding joining cleat for fixing, locking arrangement, rubber beading, screws, etc complete all as specified and directed by engr in charge. Note : (i) Glazing and wire mesh shall be measured and paid separetely only as the labour element included in the relavent item.(ii) Item shall be paid as per weight of aluminium section (iii) The rate quoted shall be inclusive of the cost of neoprene beading, glazing pin, screws and powder coated fittings such as locking arraangement etc as required, which shall not be measured for arriving the weight.(iv) The rate shall also be inclusive of complete packing with silicon gel around contacting surfaces of aluminium work, and including matching the existing. |
| 77 | S & F of Framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165 complete all as specified and as directed. |
| 78 | S&F 5mm thick tinted glass in aluminium doors & windows with rubber packing including hacking out old broken glass complete all as specified and directed by engr in charge. ( any thickness, size from aluminium beading ) |
| 79 | S&F in Stainless steel wire cloth 0.36 mm nominal dia of wire and average width of aperature 1.18mm and fixed with beeding/Staples directed . |
| 80 | M&L for Hard core of gauge n exc 63mm thick of broken bricks spread leveling watering ramming to true surface complete all as specified and directed |
| 81 | M&L for Cement concrete 1:3:6 type C-1 (using 20 mm graded stone aggregate) 75 mm thick as in plinth protections, surface finished even and smooth w/o using extra cement including 3 mm thick glass dividing strip of figured glass , pin headed type, 38 mm wide inserted in position complete all as specified and directed |
| 82 | S&F in repair 15 mm dia bore bib taps, cast copper alloy chromium plated fancy type with crutch alloy with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed complete all as specified and directed |
| 83 | Demolition of reinforced cement concrete in roofs, floors (other than ground floors), beams, staircases, landing, chajjas and similar suspended work complete all as specified and directed |
| 84 | M&L RCC type B-1, 1:2:4 (using 20 mm graded stone aggregate) in slabs, cantilever or supported on walls and small works like cubes etc complete all as specified and directed by |
| 85 | M & L for TMT bars 8 mm dia & over cut to length, bent to shape required, including crancking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia complete all as specified and directed |
| 86 | Use and waste formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including sup- ports, overhangs, etc. also splays between floors and beams, etc. |
| 87 | M & L for making in holes in masonry wall using chemical emulsion at hole, at 300mm intervals including drilling holes at 45 degree and replugging them with cement mortar 1:2 (1 cement : 2 coarse sand) to match the existing wall complete all as specified and directed |
| 88 | Extra for forming fair finished drain or channels 30 cm inner girth in Cement concrete using extra cement including forms, moulds mitred/ stopped ends etc. in manholes. ( inner girth only measured) complete all as specified and directed. |
| 89 | S&F in repair Aluminium body ISI marked Door closer hydraulically regulated, designation No. 3, universal type, suitable for door shutters of 851 to 1000 mm in width and of weight between 61 to 80 kg and fixed complete all as specified and directed |
| 90 | Taking down copper /aluminium point wiring (light, fan, bell, socket or power) complete including fixture and fittings such as switches, ceiling roses, pendent, regulators, sockets, light fitting etc. Removing materials to store for keeping in safe custody or for taking credit (credit a for above items should be made as per condition seperately) and making good distrubed surfaces of walls, floors etc complete all as specified and directed at site. |
| 91 | Taking down old/unserviceable distribution board by disconnection of electric connection carefully SPN DBs/TPN DBs/ Main Switch/Busbar including old unserviceable MCCBs/ MCBs, Isolators, etc and making good to disturbed surface complete all as specified and directed. |
| 92 | Taking down carefully copper/aluminium Sub main wiring of any size from surface/concealed /existing conduit of any height and removing materials at site and making good disturbed surfaces of walls, floors roofs etc complete all as specified and directed. |
| 93 | Taking down ceiling fan/ exhaust fan of any sweep after disconnecting all necessary electrical connections from ceiling rose to fan, fan blades and deposit to MES store yard of AGE E/M complete all as specified and as directed. |
| 94 | Taking down water heater ( geyser) any type after disconnecting all necessary connections and deposit to MES store yard of AGE E/M complete all as specified and as directed. |
| 95 | M & L for Point wiring using approved colour coding as per IS, with multistranded copper conductor 1.5 Sq. mm (nominal area), two single core, PVC insulated and unsheathed FRLS cable 1100 volts grade ISI-694 marked drawn through in and including heavy duty, PVC concealed conduit of white/ ivory colour including all accessories after chasing in wall/ceiling etc, heavy duty ISI marked, with GI sunken boxes 1.2 mm thick, 60 mm deep with earth dolly duly, covered with modular white cover plate with inner frame suitable for modular switches, including PVC insulated multistranded copper conductor 1.5 Sqmm (nominal area) single core FRLS cable as earth continuity conductor to common earth and connecting to earth dolly including cutting, chasses and making good disturbed surface to match with existing finish with plaster complete all as specified and directed for the following :- |
| 96 | (a) One light point controlled by one, one way switch 5 Amps |
| 97 | (b) One fan point/ exhaust fan point controlled by one, one way switch 5 Amps and regulator |
| 98 | (c) One 3 point 5 Amps switch socket outlet point controlled by one switch on the same board. |
| 99 | (d) One 3 pin 5 Amps switch socket outlet point controlled by one switch on independent boad. |
| 100 | Description all as per item No 95 here in before but using 2.5 sq mm single core copper conductor cable of multistranded FRLSH insulated unsheathed 1100 volts grade for 5/15 amps point including necessary running of 2.5 sq mm copper FRLSH wire as earth continuity conductor along with wiring and connecting to the common earth dolly. |
| 101 | Description all as per item No 95 here in before but using 4 sq mm single core copper conductor cable of multistranded FRLSH insulated unsheathed 1100 volts grade for 5/15 amps point controlled with modular motor starter for air conditioner including necessary running of 4 sq mm copper FRLSH wire as earth continuity conductor along with wiring and connecting to the common earth dolly. |
| 102 | S & F modular switch piano flush type, single pole, one way, and 5/6 Amp single module complete all as specified. |
| 103 | S & F modular switch piano flush type, single pole, one way, and 15/16 Amp single module complete all as specified. |
| 104 | S & F modular socket outlet multipurpose having provision for 3 pin, 5/6 Amp and 2 pin, 5/6 Amp, 2 module piano flush type complete all as specified. |
| 105 | S & F modular socket outlet multipurpose having provision for 3 pin, 15/16 Amp and 3 pin, 5/6 Amp, 2 module piano flush type complete all as specified. |
| 106 | S & F modular motor starter 32 A capacity 2 module complete all as specified. |
| 107 | S & F for Ceiling rose, surface Bakelite with 3 terminals, ISI marked for batten fitting complete all as specified and directed |
| 108 | S & F Fan step regulator, 120W - 2 module complete all as specified. |
| 109 | M & L for Sub main wiring with approved colour coding as per IS with two single core PVC insulated FRLS cable with stranded copper conductor of size 6 Sq mm nominal area and drawing into suitable size of PVC non metallic rigid heavy duty PVC conduit of white/ ivory colour and its accessaries ISI marked heavy duty of suitable size including concealed in wall etc one run of PVC insulated with 6.0 Sqmm (nominal area) stranded copper conductor FRLS cable as earth wire complete all as specified and as directed. Note:- Two runs of 6 sqmm cable,one run of 6 sqmm cable and one run of PVC conduit will be measured as one unit |
| 110 | S & F for sheet metal enclosure MCB DB vertical TPN 4 way suitable for MCCB with 200 Amps rated bus bar 415 volts double door with locking system including necessary provision for inserting the DBs in wall by cutting the brick/stone masonary etc and making good of disturbed surface to mtch with existing colour of wall complete all as specified and as directed. |
| 111 | S & F for sheet metal enclosure MCB DB SPN 8 way with 200 Amps rated bus bar 240 volts double door with locking system including necessary provision for inserting the DBs in wall by cutting the brick/stone masonary etc and making good of disturbed surface to mtch with existing colour of wall complete all as specified and as directed. |
| 112 | S & F for MCB Single pole and neutral rated capacity 32 Amps, 240 Volts breaking capacity 10 KA, 'C' curve complete all as specified and as directed. |
| 113 | S & F for MCB Single pole rated capacity 5 to 32 Amps, 240 Volts breaking capacity 10 KA, 'C' curve complete all as specified and as directed. |
| 114 | S & F for MCCB four pole rated capacity 63 Amps, 415 Volts breaking capacity 16 KA complete all as specified and as directed. |
| 115 | Hanging/Fixing only ceiling fan/exhaustfan including provision of fastner, cable from ceiling rose or connector to fan complete all as specified and as directed. |
| 116 | S & F LED lights fitting 1x 20 W, 220V,AC Polycarbonate body with driver, holder including connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete (BLDC) complete all as specified and as directed. |
| 117 | Supply and fixing LED luminaire 600 mm x 600 mm, 35/36 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete all as specified and as directed. |
| 118 | M & L for earthing complete with galvanized earth plate electrode 600mmx 600mm x 6mm thick buried directly in ground (earth pit not less than 2.25 mtr deep below ground level) with top edge of the plate not less than 1.5mtr below ground level connected to galvenised earth lead wire of 4 mm dia by means of nuts, bolts, washes of galvanized iron or steel all as shown in electrical plate No 5 and testing on completion including adequate charcoal dust comman salt necessary excavation & earth work PCC(1:3:6) type C-1 pit with precast RCC Cover slab 40 mm thick in PCC(1:2:4) type B-1 reinforced with 6 mm dia MS bars @ 100 mm c/c both ways with funnel wire mesh and 20 mm dia GI pipe medium grade as watering pipe and connected to earthing point complete all as specified and as directed. |
| 119 | S&F energy efficient saving new generation envoirnmental friendly long life versatile pressure die cast aluminium IP 65 for security light fittinf luminaire with high power LEDs as light source and electronic driver capacity 30 watt with pre wired and necessary mounting arrangements and provision of 2.5 sq mm three core copper conductor cable multi stranded from ceiling rose to light fitting including necessary dia GI pipe light grade 1.5 mtr long bend to required shape with clamps nut bolt complete all as specified and directed. |
| 120 | Taking down carefully Split type AC of any capacity with all accessories such as indoor unit, out door unit, copper pipe inlet outlet, flair nut etc. and shifting to new position including minor accessories, and making good the opening of old location with cement mortor 1:3, treating the wall to matching with existing surface finish and making opening holes on brick wall at new location and gap well finish with cement mortor 1:3, making good the wall surface to match with existing surface, installation and commissioning with replacement of insulation of suction & discharge line complete all as directed.complete all as specified and directed. |
| 121 | M&L for laying, comnecting and testing of XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavyduty) with aluminium conductor, 1100 volts Earthed, grade cross sectional area 16 sq. mm. of 4 core all as specified and directed |
| 122 | Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5m in depth for laying of pipe, cable, foundation of electric pole etc and getting out in soft/loose soil, complete all as specified and directed. |
| 123 | Supply and laying river bed fine sand in trenches/ ducts 15 cm under cable and 8 cm above the cable for cushioning / protection to cable including spreading, levelling and get thick 18cm after hand punning complete all as specified and directed at site. |
| 124 | Returning, filling in including spreading leveling watering and well ramming in layers not exc. 25 cm thick complete all as specified and directed. |
| 125 | Removing surplus soil to a distance not exc. 50 M and depositing where directed at a level not exceeding 1.5 Mtr above the starting point complete all as specified and directed. |
| 126 | Supply and laying for brick of common burnt clay, sub class 'B' old size laid flat and dry on cables as in cable protection in trenches over cables perpendicular to direction of cables abutting each other complete all as specified and directed. note :-all measurement in meter |
| 127 | Supply,laying and in replacement galvanised steel tubing light grade complete with all fitting of size 50 mm dia for cable protection along with pole across road etc. Complete all as specified and directed |
| 128 | Refixing electric water heater, storage type steel/ PVC body of capcity upto 50 litre complete with all accessories such as saftey valve, NRV, suitable connection pipe all as specified and directed |
| 129 | S & F for energy efficient exhaust fan of 450 mm sweep made of metal body heavy duty complete with louver with bolts nuts and washers size of the bolt 15 cm long 12 mm dia embedded in the wall including provision of PVC flexible copper cable of size 23/0.0076 two core from ceiling rose to exhaust fan for connection and making suitable size of hole to existing brick wall for fan base compelte all as specified and directed. Supply and laying river bed fine sand in trenches/ ducts 15 cm under cable and 8 cm above the cable for cushioning / protection to cable including spreading, levelling and get thick 18cm after hand punning complete all as specified and directed at site. Please Enable Macros to View BoQ information |