| 1 | \\" BOQ \\" BoQ_Ver3.0 Item Rate Normal INR Only INR Select, Excess (+), Less (-) Less (-) Tender Inviting Authority : Chief Engineer Shillong Zone NAME OF WORK: PROVN OF CERTAIN MD ACCN FOR OFFRs, JCOs AND ORs AT DINJAN UNDER GE DINJAN. Contract No: CESZ/DIN/ OF 2026-2027 Bidder Name : GENERAL SUMMARY (SCHEDULE OF WORKS) (This BOQ template must not be modified/replaced by the bidder and the same should be uploaded after filling the relevent columns, else the bidder is liable to be rejected for this tender. Bidders are allowed to enter the Bidder Name and Values only) NUMBER # TEXT # TEXT # NUMBER # TEXT # NUMBER NUMBER TEXT TEXT # NUMBER # TEXT# TEXT # NUMBER # NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER # NUMBER # TEXT TEXT NUMBER # NUMBER # DATE NUMBER # NUMBER # TEXT # NUMBER # Sl.No. Description of Parts/ Item Item Code / Make No. orQty. Unit Pre Priced Rate (in. Rs.) as Defined by MES Addition / Deduction Addition / Deduction Values Currency Convertion against each Item Quoted Currency in INR / Other Currency RATE In Figures To be entered by the Bidder Rs. Ps. Excise Duty VAT Freight Charges ( Unloading & Stacking) Any Other Taxes/Duties/Levies Other Taxes 2 IIIrd Party i.e DGS&D / RITES etc Inspection Charges @0.34%+Service Tax Less for Cenvat Credit,if any respect of Supplies Under full Excise Duty Category TOTAL AMOUNT in Figure TOTAL AMOUNT With Taxes TOTAL AMOUNT In Words Represent (%) Percentage having Above/ Below ( + or - denomination) the Lump sum pre price inserted by MES |
| 2 | NOTE:- (Applicable for all parts/items/):- The bidders/contractors are advised to read tender document, all drawings & all corrigendum/ amendments and General conditions of contracts before entry/quoting the rates. |
| 3 | SCHEDULE 'A' PART I DESIGN & BUILD STRUCTURENOTE: THIS SCHEDULE IS NOT PRE-PRICED BY MES AND THE PRE-PRICED RATE INDICATED AS \\"RS 0.00\\" UNDER COL. 5 SIGNIFIES THIS FACT ONLY. |
| 4 | Design & Construction of GARAGE FOR ORS & JCOS complete all as specified in tender document and as shown on Line Plan and as shown on approved drawing. |
| 5 | Design & Construction of MD ACCN (G+1) FOR 20 MAJOR & ABOVE (02 NOS DUS IN EACH FLOOR) complete all as specified in tender document and as shown on Line Plan and as shown on approved drawing. |
| 6 | Design & Construction of MD ACCN (G+2) FOR 24 JCOS (04 NOS DUS IN EACH FLOOR) complete all as specified in tender document and as shown on Line Plan and as shown on approved drawing. |
| 7 | Design & Construction of MD ACCN (G+2) FOR 96 ORS (08 NOS DUS IN EACH FLOOR) complete all as specified in tender document and as shown on Line Plan and as shown on approved drawing. |
| 8 | Design & Construction of RCC Over Head Tank 30000 UK Gallon Capacity complete all as specified in tender document and as shown on Line Plan and as shown on approved drawing. |
| 9 | SCHEDULES PREPRICED ON SSR |
| 10 | Lumpsum price worked out by the tenderer for SITE CLEARANCE, SITE DEVELOPMENTS & EARTH WORKS as listed in Schedule ‘A’ Part-II |
| 11 | Lumpsum price worked out by the tenderer for TV & TELEPHONE SOCKET as listed in Schedule ‘A’ Part-III |
| 12 | Lumpsum price worked out by the tenderer for HOT WATER SUPPLY as listed in Schedule ‘A’ Part-IV |
| 13 | Lumpsum price worked out by the tenderer for ROAD, PATH & CULVERT as listed in Schedule ‘A’ Part-V |
| 14 | Lumpsum price worked out by the tenderer for EXTERNAL WATER SUPPLY as listed in Schedule ‘A’ Part-VI |
| 15 | Lumpsum price worked out by the tenderer for SEWAGE DISPOSAL as listed in Schedule ‘A’ Part-VII |
| 16 | Lumpsum price worked out by the tenderer for AREA DRAINAGE as listed in Schedule ‘A’ Part-VIII |
| 17 | Lumpsum price worked out by the tenderer for SECURITY WALL,FENCING AND GATE as listed in Schedule ‘A’ Part-IX |
| 18 | Lumpsum price worked out by the tenderer for EXTERNAL ELECTRIC SUPPLY as listed in Schedule ‘A’ Part-X |
| 19 | SCHEDULE 'A' SEC-XI (MISCELLANEOUS ITEMS) NOTE: THIS SCHEDULE IS NOT PRE-PRICED BY MES AND THE PRE-PRICED RATE INDICATED AS \\"RS 0.00\\" UNDER COL. 5 SIGNIFIES THIS FACT ONLY. |
| 20 | Supply and fixing wall mounted stainless steel electric kitchen chimney 90 cm with 1500 cum/hr suction, Intelligent auto clean curved glass, speed touch type control with RPM display & motion sensor control, BLDC motor, filterless with oil collector tray for easy cleaning, max noise level 58 dB, inbuilt LED light including aluminium flexible duct/ exahust pipe of 150 mm dia of heat resistant suitable length with suction cover/ cowl cover, aluminium adhesive tape, clamps etc with all accessories including making/ cutting hole of 150 mm dia suitable for aluminium exhaust pipe and making good complete all as specified and directed. |
| 21 | Supply and fixing modular TV Socket with suitable size modular junction/sunken box, modular frame and cover plate including all connecting accessories complete all as specified and directed. |
| 22 | Supply and fixing modular telephone socket with suitable size modular junction/sunken box, modular frame and cover plate including all connecting accessories complete all as specified and directed. |
| 23 | Supply , installation, testing and comissioning of Three Phase Cellular Smart energy prepaid Meter confirming to IS-16444: 2015 (Reaffirmed 2020) and as ammended time to time, AC, three phase, four wires, Tamper Proof static Smart Energy Meter of rating 415 Volt, 10-100 Amps,50 Hz , Class 1, enclosed in polycarbonate box complete as specified in CEA notification. The meter shall communicate with Head End System (HES) on any of the communication technologies mentioned in IS-16444 Part-I . The selection of communication technology should be as per the site conditions and as per design consideration of AMI Implementing agency to meet the performance. The smart meters should be based on existing communication technology/ system of Stn. The meter shall be provided with transparent polycarbonate ABS thermoplastic box with sealing arrangements of suitable size as per the requirement of OEM of Electric meter complete all as specified and directed.Note: (i) Meter should support 15 Min instantaneous data for voltage, current power, power factor, cumulative energy and frequency.(ii) Bidder shall procure meter from three different manufacturer having minimum quantity of any one make shall not be less than 30% of total meter. (iii) Meter shhuld be compatible with exsting/ Stn communication system. |
| 24 | Supply , installation, testing and comissioning of Single Phase Cellular Smart energy prepaid Meter confirming to IS-16444: 2015 (Reaffirmed 2020) and as ammended time to time, AC,single phase, 2 wires, Tamper Proof static Smart Energy Meter of rating 240 Volt, 10-60 Amps,50 Hz , Class 1, enclosed in polycarbonate box complete as specified in CEA notification. The meter shall communicate with Head End System (HES) on any of the communication technologies mentioned in IS-16444 Part-I . The selection of communication technology should be as per the site conditions and as per design consideration of AMI Implementing agency to meet the performance. The smart meters should be based on existing communication technology/ system of Stn. The meter shall be provided with transparent polycarbonate ABS thermoplastic box with sealing arrangements of suitable size as per the requirement of OEM of Electric meter complete all as specified and directed.Note: (i) Meter should support 15 Min instantaneous data for voltage, current power, power factor, cumulative energy and frequency.(ii) Bidder shall procure meter from three different manufacturer having minimum quantity of any one make shall not be less than 30% of total meter. (iii) Meter shhuld be compatible with exsting/ Stn communication system. |
| 25 | Recurring Monthly Sim charges (GPRS/Internet and SMS charges) to be paid to existing AMISP in the station, post commisioning and activation of smart energy meter for 6 month period or till time of sucessful integration with existing AMISP. Note : (i) The meter SIM shall be capable to communicate with existing AMISP in the Stn and shall be integrated with existing HES and MDM network in the stn.(ii) Recurring monthly payment may be claimed by tenderer on monthly basis. |
| 26 | M&L for concealed CPVC Hot water pipe 13.5 SDR designed for hot & cold water capable of withstanding temprature not less than 93 degree Celcius (200 Degree F) as per IS 15778 including all fixing accessories of 40 mm dia complete all as specified and directed. |
| 27 | M&L for concealed CPVC Hot water pipe 13.5 SDR designed for hot & cold water capable of withstanding temprature not less than 93 degree Celcius (200 Degree F) as per IS 15778 including all fixing accessories of 32 mm dia complete all as specified and directed. |
| 28 | M&L for concealed CPVC Hot water pipe 13.5 SDR designed for hot & cold water capable of withstanding temprature not less than 93 degree Celcius (200 Degree F) as per IS 15778 including all fixing accessories of 25 mm dia complete all as specified and directed. |
| 29 | M&L for concealed CPVC Hot water pipe 13.5 SDR designed for hot & cold water capable of withstanding temprature not less than 93 degree Celcius (200 Degree F) as per IS 15778 including all fixing accessories of 20 mm dia complete all as specified and directed. |
| 30 | M&L for concealed CPVC Hot water pipe 13.5 SDR designed for hot & cold water capable of withstanding temprature not less than 93 degree Celcius (200 Degree F) as per IS 15778 including all fixing accessories of 15 mm dia complete all as specified and directed. |
| 31 | M&L speed bump made from heavy duty ABS with high resistance wear & tear property. UV stabilized black & yellow combination high reflective reflector having L=70 mm, W=23 mm available on both sides in red and yellow colour with H= 50 mm, W= 380 mm, L= 500 mm all as specified and directed. |
| 32 | Supplying, laying, jointing and testing of DI pipe of size 150 mm dia (6\\") as per IS 8239/2000 class K-9 with inside cement mortar lining with spigot and socketed end including rubber gasket joint (tyton joint) laid in trenches complete all as specified and directed. |
| 33 | Supplying, laying, jointing and testing of DI pipe of size 150 mm dia (6\\") as per IS 8239/2000 class K-7 with inside cement mortar lining with spigot and socketed end including rubber gasket joint (tyton joint) laid in trenches complete all as specified and directed. |
| 34 | Supplying, laying, jointing and testing of DI pipe of size 100 mm dia (4\\") as per IS 8239/2000 class K-7 with inside cement mortar lining with spigot and socketed end including rubber gasket joint (tyton joint) laid in trenches complete all as specified and directed. |
| 35 | M&L for DI fittings such as Tees, bends (any type, radius and angle) tapers any type, collars, tail pieces, caps and plugs, confirming to IS: 1538-1993 of size upto 150 mm bore complete all as specified and directed. |
| 36 | M&L for Construction of masonary valve pit chamber of size internally 1200 x 1200 x 1200 mm with burnt brick (Sub class \\"B\\") in cement mortar (1:6) including 10 mm thick plastering in CM (1:4) internally on full depth of wall and externally up to 15 cm bellow the ground level, PCC (1:4:8) type D-2 using 40 mm graded crushed stone aggregate as in foundation bed, 3 mm thick MS sheet cover with locking arrangement hinged with 40 x 40 x 5 mm angle iron frame embeded in PCC (1:3:6) type C-1 using 20 mm graded crushed stone aggregate, painting with two coats of synthetic enamel paint over a coat of red oxide primer to all steel surfaces both internally and externally, earth work complete all as specified and directed. |
| 37 | M&L for Construction of masonary valve pit chamber of size internally 600 x 600 x 600 mm with burnt brick (Sub class \\"B\\") in cement mortar (1:6) including 10 mm thick plastering in CM (1:4) internally on full depth of wall and externally up to 15 cm bellow the ground level, PCC (1:4:8) type D-2 using 40 mm graded crushed stone aggregate as in foundation bed, 3 mm thick MS sheet cover with locking arrangement hinged with 40 x 40 x 5 mm angle iron frame embeded in PCC (1:3:6) type C-1 using 20 mm graded crushed stone aggregate, painting with two coats of synthetic enamel paint over a coat of red oxide primer to all steel surfaces both internally and externally, earth work complete all as specified and directed. |
| 38 | Supply, Installation, testing and commissioning of Package type/ unitised 11KV/433V Outdoor Sub-station, 400 KVA made from GI enclosure cpmplete as required confirming to IEC 62271-202 only and relevant IS specifications including K-10 temperature class as applicable for the rating, Internal Arc of 21 KA/1 Sec. IAC AB on 1:2:4 PCC foundation of suitable size extending 500mm all around the outdoor enclosure and 1000mm height (above the ground level ) complete with suitable sizes of GI pipes for incoming/outgoing cables/earthing strips etc. and consisting of following complete as required. Angle iron frame of size 40X40X5 mm MS all along with the corner of the foundation od CSS shall be from OEMs only. Licensed System Integrators of approved OEM are not allowed to supply .Make - Siemens/Schneider Infra/ABBPackage Substaion will have the following euipment :- HT Swichgear :-11 KV 630 Amps 21 KA / 3 Sec Non Extensible Ring Main Unit Compact Switchgear consisting of direct cable module & 1 No motorized Circuit Breakers Module in SF6 insulated stainless enclosure with series trips, self powered microprocessor based numerical over current and earth fault relay protection. HT RMU shall perferably have site replaceable bushings to have very less downtime in the event of bushing breakage and restoration can be done immediately without sending the RMU to OEM Works. Interconnection between HT Switchgear and primary of transformer shall be done through IC x 95 sq. mm Aluminium XLPE cable - 1 No. |
| 39 | Serial item No. 3.19 continued....Vacuum Interrupter & RMU shall be of same make to ensure life cycle optimization.Microprocessor based IDMT Relay for Circuit Breakers - Self Powered along wtih series trip coil (Modbus RS485 complaint.Capacitive voltage indication fixed type system with LED for all feeder and FPI in all load break switch feeder.SF6 Gas pressure indicator.Operating sequence of VCB must be O-0.3sec-CO-3 Mins CO - Protection CT shall be minimum 40/1A, 2.5VA, 5P10 - 3 nos. All modules of the RMU shall be suitable for cable termination of 3C x 95 Sq.mm AI XLPE Cable, incoming cable termination is included within the scope of work - 1 setTRANSFORMER: -11/0.433KV, 400 KVA, 50Hz, Off load Tap Changer switch, Three Phase, natural ester oil type transformer in corrugated tank i) Standard IS : IS : 2026 and IS 1180 with latest amendments (2021)ii) Losses as per 1180 level 2 and Temperature rise shall be as per IS 1180 with latest amendmentsiii) Outdoor Installationiv) Vector group : Dyn 11v) Rating 500 KVAvi) Cooling System : KNAN (K for Ester oil)vii) Winding ; Copperviii) Magnetic Core : Prime grade of M4 or better |
| 40 | Serial item No. 3.19 continued....ix) High voltage : 11 KV - 50 Hzx) Low Voltage : 433 V - 50Hzxi) System highest Voltage : 12 KV at the HV sidexii) Percentage Impendance Value : As per IS 1180xiii) Manufacturer shall have NABL accredited testing labotatoryxiv) Insulation Level : HV Power Frequency (KV rms) : 28 KV HV, Impulse withstand voltage (KV peak) : 75 kVpxv) Tapping : +5% to -15% OLTC @ 2.5%xvi) HT Termination - Cable Boxxvii) LT termination - cable box and with all accessories i.e. first filling of filtered dehydrated oil and confirming to ID & standard accessories required (xviii) OEM shall have in house core cutting facility for proper control & monotoring of quality & to avoid mixing of prime core with second grade / defective core materialsLT PANELLVS PANEL 1000 AMPS 4 pole Aluminium BUSBAR (100% FOR PHASES AND 100% FOR NEUTRAL) - CURRENT DENSITY OF Aluminium as 1 A./sq.mm; LT panel made up of 1.5/2 mm thick CRCA sheet. |
| 41 | Serial item No. 3.19 continued....INCOMER FROM TRANSFORMER630 Amps 433 V 50 Hz 50 KA draw out Type Microprocessor Release based MCCB - 01 No.Smart energy Meter (IS-16444), AC whole current, three phase, 4 wires, CT operated Smart Energy Meter of Class 0.5 S ,415 V, 50 Hz, 1b 5A complete all as specified. The meter shall communicate with Head existing End System (HES) on any of the communication technologies mentioned in IS-16444 Part-I in a secure manner. The selection of communication technology should be as per the site conditions and as per existing AMR infrastructure available in the station. The smart meter may be based on RF Mesh communication technology or Cellular communication technology as per site requirements with transparent polycarbonate ABS thermoplastic box with sealing arrangements of suitable size as per the requirement of OEM of Electric meter. The cost of meter would include the supply of current transformer, Rated burden 15 VA, Accuracy class 0.5 S, frequency 50 Hz and voltage class 660 V effectively earthed and CT ratio suitable as (600/5) complete - 01 NoOUTGOING :- Microprocessor based MCCB 500 A, 50 KA, 4 Pole - 03 Nos (01 No Spare) (For Panel No 1 for OR Block No 1 & 2 & Panel No 2 for OR Block No 3 & 4) Thermal Magnetic Release MCCB 150 A, 36 KA, 4 Pole - 03 Nos (01 No Spare) (For JCO Block No 1 & 2) Time switches 415 V, 3 phase of 20 Amp Rating with contactor fitted inside the enclosure - 01 No100 KVAR APFC panel with minimum 5 steps as per following tentive steps (50 KVAR X 1, 25 KVAR X 1, 15 KVAR X 1, 5 KVAR X 2)All Civil works such as PCC/RCC foundation, Plateform, Filling trench and pedestal etc as per CSS manufacturer's recommendation are included in scope of work.OUTDOOR ENCLOSUREOutdoor type enclosure of 1.5 mm (For non load bearing members) & 2.0 mm (For load bearing members) thickness having modular construction of Galvanised Sheet Steel in suitable designed for better heat dissipation and providing robust construction. The Enclosure shall have IP54 degree of protection for HT & LT switchgear compartment & IP 23 degree of protection for transformer compartment. The enclosure exterior shall be painted with epoxy based powder paint (colour RAL 7032). Each compartment will be provided with the door and pad locking arrangement. The design of the enclosure should be type tested for suitably handling any arcing inside the compartment illumination lamp with door operated switch shall be provided for each compartment. |
| 42 | Boring holes under road pavement by bocky manually in any type of soil upto 250 mm bore complete all as specified and directed |
| 43 | Supply and fix , test , commissioning of LT weather proof panel board powder coated outdoor type double door shutter, made out of CRCA 3.15 mm thick outer and 2.0 mm thick for inner door confirming to IS 8623 with angle iron 50 X 50 X 6 mm outoor, floor mounting type with closed bus bar, chamber and with aluminium bus bar with necessary insulators suitable for 3 phase, 4 wire 50 Hz AC supply including provn of indicator lamps R-Y-B, selector switches and internal wiring including making PCC block type 0.6 Mtr above ground level grouting etc all as specified and directed with the following work also includes provision of suitable size of cable glands, cable lugs, nut, bolts, washers etc. The bottom portion of enclosure shall be minimum 60 cm above ground level of legs of angle iron (Panel No 3 For Offrs Md Accn) INCOMING:Thermal Magnetic Release MCCB 125 A, 25 KA, 4 Pole - 06 Nos (01 No Spare)MCB TPN 20 Amps 10 KA - 02 NosTime switches 415 V, 3 phase of 20 Amp Rating with contactor fitted inside the enclosure - 01 No |
| 44 | Serial item No. 3.21 continued....Smart energy Meter (IS-16444), AC whole current, three phase, 4 wires, CT operated Smart Energy Meter of Class 0.5 S, 415 V, 50 Hz, 1b 5A complete all as specified. The meter shall communicate with Head End System (HES) on any of the communication technologies mentioned in IS-16444 Part-I in a secure manner. The selection of communication technology should be as per the site conditions and as per design consideration of AMI Implementing agency to meet the performance. The smart meter can based on RF Mesh communication technology or Cellular communication technology. The meter shall be provided with transperent polycarbonate ABS thermoplastic box with sealing arrangements of suitable size as per the requirement of OEM of Electric meter. The cost of meter would include the supply of current transformer, Rated burden 15 VA, Accuracy class 0.5 S, frequency 50 Hz and voltage class 660V effectively earthed and CT ratio suitable as (60/5 to 1000/5) complete - 01 NoIndicating Lamps (R, Y & B) - 01 Set OUTGOING:Thermal Magnetic Release MCCB 125 A, 25 KA, 4 Pole - 06 Nos (01 No Spare)MCB TPN 20 Amps 10 KA - 02 NosTime switches 415 V, 3 phase of 20 Amp Rating with contactor fitted inside the enclosure - 01 No |
| 45 | Supply and fix , test , commissioning of LT weather proof panel board powder coated outdoor type double door shutter, made out of CRCA 3.15 mm thick outer and 2.0 mm thick for inner door confirming to IS 8623 with angle iron 50 X 50 X 6 mm outoor, floor mounting type with closed bus bar, chamber and with aluminium bus bar with necessary insulators suitable for 3 phase, 4 wire 50 Hz AC supply including provn of indicator lamps R-Y-B, selector switches and internal wiring including making PCC block type 0.6 Mtr above ground level grouting etc all as specified and directed with the following work also includes provision of suitable size of cable glands, cable lugs, nut, bolts, washers etc. The bottom portion of enclosure shall be minimum 60 cm above ground level of legs of angle iron (Panel No 1 for OR Blocks No 1 & 2 and Panel No 2 for OR Blocks No 3 & 4) INCOMING:Aluminium bus bar capacity 600 Amps for Phase-R-Y-B- & neutral Microprocessor based MCCB 400 A, 36 KA, 4 Pole I/C - 01 No |
| 46 | Serial item No. 3.22 continued....Smart energy Meter (IS-16444), AC whole current, three phase, 4 wires, CT operated Smart Energy Meter of Class 0.5 S, 415 V, 50 Hz, 1b 5A complete all as specified. The meter shall communicate with Head End System (HES) on any of the communication technologies mentioned in IS-16444 Part-I in a secure manner. The selection of communication technology should be as per the site conditions and as per design consideration of AMI Implementing agency to meet the performance. The smart meter can based on RF Mesh communication technology or Cellular communication technology. The meter shall be provided with transperent polycarbonate ABS thermoplastic box with sealing arrangements of suitable size as per the requirement of OEM of Electric meter. The cost of meter would include the supply of current transformer, Rated burden 15 VA, Accuracy class 0.5 S, frequency 50 Hz and voltage class 660V effectively earthed and CT ratio suitable as (60/5 to 1000/5) complete - 01 NoIndicating Lamps (R, Y & B) - 01 Set OUTGOING:Thermal Magnetic Release MCCB 200 A, 25 KA, 4 Pole - 05 Nos (01 No Spare) |
| 47 | Provision of Loop in loop out box of FRP made with IP 65 protection of thermoplastic circuit breaker boxes with metric knockouts for cable entry and exit , combi climate cable glands of IP 66 / 67 for cable entry and grommets IP 65 for conduit for cable exit, terminals as PVC connector heavy duty 32 Amps, 4 way for cable necessary fixing arrangements and with cable glands ,etc all as specified and directed. |
| 48 | Supply, laying, jointing and testing of 150 mm internal diameter of double wall corrugated (DWC) high density polyethylene pipe (HDPE) and stiffness classes -8 (SN-8) with ISI marked (with CML No) and including all fitting of pipe & jointing material for sewage line and laid in trenches all as specified in IS -16098-2013 part-2 complete all as specified and directed. |
| 49 | M&L for construction of Brick Septic tank designed to carry sewage and sullage water including excavation in any type of soil, PCC (1:4:8) type D2 using 40 mm graded crushed stone aggregate as in foundation, RCC (1:1.5:3) type A1 using 20 mm graded crushed stone aggregate as in Baffle walls and Roof Slab and in beams etc with Vent shaft,manhole openings with cover connection etc for 150 users capacity all as per TD Drawing or drawing available with sub division complete all as specified and directed. |
| 50 | M&L for construction of Soakage well of size 2.4 m dia and 3.0 m depth including excavation in any type of soil, PCC (1:3:6) type C2 using 40 mm graded crushed stone aggregate as in foundation, walls of honey combed masonry with top ring of M25 grade design mix concrete, provision of intercepting chamber and screen chamber made of Brick masonary in CM (1:4) , RCC (1:1.5:3) type A1 using 20 mm graded crushed stone aggregate as in cover slab , interconnecting pipes of RCC/DWC, filling with brick bats complete all as specified and directed. |
| 51 | M&L for construction of Brick Septic tank designed to carry sewage and sullage water including excavation in any type of soil, PCC (1:4:8) type D2 using 40 mm graded crushed stone aggregate as in foundation, RCC (1:1.5:3) type A1 using 20 mm graded crushed stone aggregate as in Baffle walls and Roof Slab and in beams etc with Vent shaft,manhole openings with cover connection etc for 500 users capacity all as per TD drawing or drawing available with sub division complete all as specified and directed. |
| 52 | Design, Supply, Erection, Testing and commissioning Roof top grid interactive solar photo voltaic plant system inclusive of the solar panels of prescribed efficiency, mounting structure, cabling, inverter, panel metering devices, earthing, lightning protection complete as per state-of-the-art technology as per good engineering practice compliant to relevant Indian standards/local/statutory authorities/MNRE guidelines of capacity 40 KWP with high efficiency PV cells. Minimum power output guarantee offered for the SPV Module shall not be less than rated for 25 years Invertors/power conditioning unit (PUC suitable for mains as well as DG supply) as required. However, Capacity of each invertor should not be more than 30 kwp:The inverter output shall always follow the grid in terms of voltage and frequency: AC collection panel with metering to monitor generation at the terrace and AC cabling from panel to receiving switch, measuring devices i/c net metering indication devices, protection devices, switching devices, all necessary wiring, DC and AC cabling including feeding power to essential supply by providing necessary tap off boxes, mounting structure of GI on terrace of the building protection of system for external/internal causes and form all kind of surges incl earthing and lighting protection of solar system complete all as specified and directed |
| 53 | Design, Supply, Erection, Testing and commissioning Roof top grid interactive solar photo voltaic plant system inclusive of the solar panels of prescribed efficiency, mounting structure, cabling, inverter, panel metering devices, earthing, lightning protection complete as per state-of-the-art technology as per good engineering practice compliant to relevant Indian standards/local/statutory authorities/MNRE guidelines of capacity 20 KWP with high efficiency PV cells. Minimum power output guarantee offered for the SPV Module shall not be less than rated for 25 years Invertors/power conditioning unit (PUC suitable for mains as well as DG supply) as required. However, Capacity of each invertor should not be more than 30 kwp:The inverter output shall always follow the grid in terms of voltage and frequency: AC collection panel with metering to monitor generation at the terrace and AC cabling from panel to receiving switch, measuring devices i/c net metering indication devices, protection devices, switching devices, all necessary wiring, DC and AC cabling including feeding power to essential supply by providing necessary tap off boxes, mounting structure of GI on terrace of the building protection of system for external/internal causes and form all kind of surges incl earthing and lighting protection of solar system complete all as specified and directed |
| 54 | Design, Supply, Erection, Testing and commissioning Roof top grid interactive solar photo voltaic plant system inclusive of the solar panels of prescribed efficiency, mounting structure, cabling, inverter, panel metering devices, earthing, lightning protection complete as per state-of-the-art technology as per good engineering practice compliant to relevant Indian standards/local/statutory authorities/MNRE guidelines of capacity 10 KWP with high efficiency PV cells. Minimum power output guarantee offered for the SPV Module shall not be less than rated for 25 years Invertors/power conditioning unit (PUC suitable for mains as well as DG supply) as required. However, Capacity of each invertor should not be more than 30 kwp:The inverter output shall always follow the grid in terms of voltage and frequency: AC collection panel with metering to monitor generation at the terrace and AC cabling from panel to receiving switch, measuring devices i/c net metering indication devices, protection devices, switching devices, all necessary wiring, DC and AC cabling including feeding power to essential supply by providing necessary tap off boxes, mounting structure of GI on terrace of the building protection of system for external/internal causes and form all kind of surges incl earthing and lighting protection of solar system complete all as specified and directed Total in Figures 0.0 0.0 INR Zero Only Quoted Rate in Figures Select 0.0 0.0 Zero Only Quoted Rate in Words INR Zero Only Please Enable Macros to View BoQ information |